Pressing the Edit Opts button displays the Edit Options menu screen (Figure 4-27). The three buttons on the menu screen provide links to secondary screens where the main ARCvault settings can be set or changed.
NOTE: These three options can be password protected with Administrator-level security. The default Administrator security setting is disabled. Refer to “Passwords Button” on page 4-21 to change it.
Figure 4-27: Edit Options Screen
CAUTION: Pressing a button on the Edit Options screen causes the loader to go offline. A confirmation message is displayed before taking the unit offline. Once you exit the menu, the loader automatically goes back online.
Library Button (Editable)
The Library button on the Edit Options screen lets you edit the loader user options. Use the and arrows to shift between options. The option name is shown in the label field (larger rectangle) on the left and the current setting is shown in the data field (smaller rectangle) on the right. To make changes, press the data field to display a data entry screen (Figure 4-28).
Figure 4-28: Press Data Field to Display Data Entry Screen Changing Edit Library Options
1. Use the and arrows to select the option to be changed.
2. Press the data field to the right of the option label.
3. Enter the change in the New data field (see Table 4-9).
4. Press Save to execute (or Cancel to return to the menu).
5. At the confirmation message, press OK.
The change goes into effect immediately unless you are changing the number of Reserved slots which requires an immediate reboot.
Data Field
(Displays)
Table 4-9 shows the different Edit Library Options available:
Network Button (Editable)
The Network button on the Edit Options screen lets you edit the network user options. The current option setting is shown in the data field (rectangle) to the right of the option label. To make changes, press the data field to display a data entry screen (Figure 4-29).
IMPORTANT: To activate the Static IP address options, you must first change the IP Addr Assignment setting from DHCP to Static. You can then edit the four static IP address settings (Library IP, IP Mask, IP Gateway, and DNS Server). The Static address changes do not take effect until the unit is rebooted.
Figure 4-29: Press Data Field to Display Network Data Entry Screen Table 4-9: Editable Library Options
Option Description
Reserved Slots Lets you reserve up to 12 slots. The slots are reserved from the last enabled slot forward, and are labeled “R n” on the Cartridge Map and Status screens. The reserved slots can be used to store cleaning cartridges or to reduce the number of active slots to meet host software requirements.
Edit: Press the New data field. At the pop-up keyboard, enter a number between 0 and 12, and press OK. Press Save.
Default: 0.
LCD Contrast Lets you increase or decrease the contrast of the LCD display. The incremental steps range from 0 to 63.
Pressing the arrow increases the number in the New field and lightens the screen. Pressing the arrow decreases the number and darkens the screen.
Edit: Press the New data field, use the and arrows to change the number in the New data field, and then press Save.
Default: 32.
Data Field
(Displays)
4. Press OK to accept the change (or Cancel to return to the menu).
5. When finished making changes to Network options, press Save (or Cancel).
6. At the reboot message, press OK to return to the Edit Options screen.
7. Press Back twice to return to Default screen.
8. Press Power > Reboot.
Table 4-10 shows the different Edit Network Options available.
Table 4-10: Editable Network Options
Option Description
IP Address Assignment
Lets you choose the method for setting the IP address of the loader’s RMU protected website. Choose either to use a DHCP server or manually enter Static IP addresses.
Edit: Press either DHCP or Static, and press OK.
Default: Static.
Library IP Addr* (Static) Lets you enter a specific static IP address to be used to access RMU.
NOTE: Only available if the IP address assignment is set to Static.
Edit: Press the New data field. At the pop-up keyboard, enter an IP number, and press OK.
Default: 10.0.0.1.
IP Mask* (Static) Lets you enter a specific static subnet mask IP address to be used to access RMU.
NOTE: Only available if the IP address assignment is set to Static.
Edit: Press the New data field. At the pop-up keyboard, enter an IP number, and press OK.
Default: 255.255.255.Ø.
IP Gateway* (Static) Lets you enter a specific static gateway IP address to be used to access RMU.
NOTE: Only available if the IP address assignment is set to Static.
Edit: Press the New data field. At the pop-up keyboard, enter an IP number, and press OK.
Default: 255.255.255.255.
DNS Server* (Static) Lets you enter a specific DNS server IP address to be used.
NOTE: Only available if the IP address assignment is set to Static.
Edit: Press the New data field. At the pop-up keyboard, enter an IP number, and press OK.
Default: 255.255.255.255.
SCSI/FC Button (Editable)
The SCSI/FC button on the Edit Options screen lets you edit the SCSI drive bus ID. The current option setting is shown in the data field (rectangle) to the right of the option label. To make changes, press the data field to display a data entry screen (Figure 4-30).
Web Lvl 1
& FTP Login
Lets you choose a login code to access User-level security options in RMU and perform FTP activities. Enter up to 12 alphanumeric characters using hex characters Ø–9 and A–F.
NOTE: Only capital letters are available from the OCP.
Edit: Press the New Login data field. At the pop-up hexadecimal keyboard, enter a login password, and press OK.
Default: 1.
Web Lvl 2 Login
Lets you choose a login code to access Administrator-level security options in RMU. Enter up to 12 alphanumeric characters using hex characters Ø–9 and A–F.
NOTE: Only capital letters are available from the OCP.
Edit: Press the New Login data field. At the pop-up hexadecimal keyboard, enter a login password, and press OK.
Default: 2.
Disable Web Lvl 2 Access
Lets you prevent others from accessing the loader remotely with Administrator level security. The options are Yes or No.
Selecting Yes prevents Level 2 (Administrator) security RMU access from working. Only Level 1 (User) security is allowed thus limiting remote access to only the Status and History screens.
Edit: Press either Yes or No, and press OK.
Default: No.
*.These options are only valid if the IP Addr Assignment option is set to Static. Otherwise, they read "DHCP" and are inactive.
Table 4-10: Editable Network Options (Continued)
Option Description
Data Field
(Displays)
2. Enter the change in the New data field (see Table 4-11).
3. Press Save to execute (or Cancel to return to the menu).
4. At the confirmation message, press OK.
The change goes into effect immediately.
Table 4-11 shows the different Edit SCSI/FC Options available.