Cannot add fixed constraint as it is in conflict with another fixed constraint.
• Meaning: While using the Point Along command, you tried to add a constraint that conflicted with another constraint.
• Recovery: Specify different inputs for the Point Along command.
Cannot copy report to the catalog. Filter is not a catalog filter.
• Meaning: You are trying to save a report to the catalog that has been defined with a filter that is not a catalog filter.
• Recovery: Create a catalog filter that uses the same definition you require for your report and use it in your report definition.
Cannot create another Analysis Model; the current number of Analysis Models allowed is limited to one.
• Meaning: You cannot create a second Analysis Model in this version of the software.
• Recovery: Delete the existing Analysis Model.
Cannot edit the PDS portion of this filter nor display the PDS model reference, since PDS software components have not been installed on this machine to make that possible. You may work with the other portions of this filter or you can install PDS components so that you can then work with the PDS portion of this filter.
• Meaning: You are attempting to define a workspace for a model that includes a PDS reference on a computer without the necessary PDS components.
• Recovery: Install the PDS components. For more information, see the Install Additional Product Software section in the SmartPlant 3D Installation Guide. Or, you can click OK, and continue defining your workspace.
Cannot import new section sizes while analytical model status is Approved or Rejected.
• Meaning: The status of the analytical model is set to Approved or Rejected. The software will not update an analytical model with either of these statuses.
• Recovery: Edit the properties of the analytical model, and set the status to either Working or In Review.
• Meaning: The software uses the MSDTC to coordinate transactions for saving objects, modifying objects, and so forth. This service is required for the operation of the software.
• Recovery: Set up the MSDTC. For more information about configuring the MSDTC, see the Installation Guide.
Cannot remove active task from the list.
• Meaning: You attempted to remove a task from the Configure Task List dialog box while that task was active.
• Recovery: Edit the properties of the analytical model, and set the status to either Working or In Review.
Cannot rotate such that the reference line on the selected object goes through the point you entered. The entered point is closer to the rotation point than the reference line is. Enter a point further away from the rotation point.
• Meaning: When using the Rotate Object command, you clicked a graphic input point that is closer to the rotation point than the reference line.
• Recovery: Choose a different graphic input point (one that is further away from the rotation point). Alternatively, you can choose a different
reference line or rotation point.
Cannot rotate the object(s) because a constraint exists. First edit the constraints before proceeding with this rotation..
• Meaning: When using the Rotate Object command, you attempted to rotate an object that is constrained, such as a piece of equipment mated with a slab.
• Recovery: Modify or remove the constraint, and then run the command again.
Cannot switch to [Task Name] task because the required active database connection is not available.
• Meaning: You are trying to open a session file that was saved in a task that is not installed on the current workstation.
• Recovery: Open the session file on a computer with the specific task installed. Or, install the task on the computer you are working on.
Cannot unlock Theta while only the Radius is locked. To unlock this angle first unlock Radius.
• Meaning: On the PinPoint ribbon (cylindrical coordinates), you are
Cannot unlock this angle while Absolute Distance is locked and no other angle is locked. To unlock this angle first unlock Absolute Distance or lock the other angle.
• Meaning: On the PinPoint ribbon (spherical coordinates), you are trying to unlock the only locked angle while the Absolute distance setting is locked. At least one angle must be locked for Absolute distance to remain locked.
• Recovery: Lock the other angle, or unlock the Absolute distance setting.
Cannot unlock this angle while only the Vertical angle is locked. To unlock this angle first lock Absolute distance or unlock Vertical angle.
• Meaning: On the PinPoint ribbon (spherical coordinates), you are trying to unlock an angle while only the Vertical angle is locked.
• Recovery: Lock the Absolute distance setting, and then unlock the angle.
Or, unlock the Vertical angle, and unlock the angle.
Cannot unlock Z while only the Radius is locked. To unlock this first unlock Radius.
• Meaning: On the PinPoint ribbon (cylindrical coordinates), you are trying to unlock the Z value while the Radius setting is locked.
• Recovery: Unlock the Radius setting, and then unlock Z.
Cannot write to log file - log file is read only.
• Meaning: The log file that you have specified already exists and is read-only.
• Recovery: Either specify a different log file name, or reset the
permissions of the existing log file to remove the Read-only attribute.
Change the status of members to In Review or Working.
• Meaning: The software tried to update the section sizes on members whose status is set to Approved or Rejected.
• Recovery: Edit the properties on the members, and set the status to either In Review or Working.
Compartment tables are not available in the [Catalog or Model].
• Meaning: Some compartmentation data is missing in either the Catalog or Model database.
• Recovery: Add the data to the database with the problem.
Could not get a port from the piece of equipment.
Could not start the service as it is not configured with proper site and schema database(s).
• Meaning: The Interference Checking Service (IfcNtSvc) was not started due to configuration problems.
• Recovery: Reconfigure the Interference Checking Service to use the correct site and schema database(s).
Cross-section size is equal to the current end.
• Meaning: You have not changed the dimensions of the cableway to create the transition.
• Recovery: Change the width, depth, or corner radius to insert a transition.
You can access these dimensions on the ribbon.