MINI-LINK SAU DATA

In document Ericsson SOM Operator Guide (Page 99-102)

Fieldname Format Description Example

MINI-LINK SAU DATA

2BElement Management User Interface

Fieldname Format Description Example

Far Hop Side ID Text string Far_Hop_Side_ID from NE terminal

properties

Subnet ID Text string Sub-network id of the terminal Description Text string Description from NE terminal properties Traffic Rate

Description Text string Traffic_Rate_Description from NE

terminal properties

Can be:

0 Validity Text string Value 1 if collection valid, 0 otherwise

1

MINI-LINK SAU DATA

Table 10 MINI-LINK SAU Data

Fieldname Format Description Example

Terminal ID Text string ID of the MINI-LINK Terminal 001A

Equipment Type Text string The type of equipment MLE_SAU

IDS In Own AMM Text string List of terminal IDs in the own AMM 001A-001B-501A

NCC AM No Text string Expanded NCC AM number Can be also

INACTIVE IDs In Connected EAC Text string List of terminal IDs connected to the

EAC (External Alarm Channel) bus at the same site

A001-C001

IDS In Connected

AMM Text string List of terminal IDs available on

expanded NCC

001A-001B-501A IDS In Connected RTU Text string List of connected E_Micro terminal

IDs E05B-E04B

Can be:

NA ON RAC1 Active Text string Indicates if the RAC1 (Remote Alarm

Channel) is enabled

OFF RAC1 Remote ID Text string Terminal ID of the SAU at the

far-end of the RAC

Can be:

RAC1 Interface Text string Type of interface

RS232 or G.703 Can be:

NA ON RAC2 Active Text string Indicates if the RAC2 (Remote Alarm

Channel) is enabled

OFF RAC2 Remote ID Text string Terminal ID of the SAU at the

far-end of the RAC

Can be:

RAC2 Interface Text string Type of interface

RS232 or G.703 User1 I\O Config Text string User Input port configuration

<Type of port (always IN)> -

User IN - Status : NO - Sev. : critical

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

Status : <(NO/NC)> - Sev. :

<Severity for the User Input>

NO = Normally Open NC = Normally Closed

User2 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User3 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User4 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User5 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User6 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User7 I\O Config Text string User Input port configuration Format as described in User1_IO_Config

User8 I\O Config Text string User Input port configuration Format as described in User1_IO_Config User9 I\O Config Text string User Input/output port configuration

IN:

<Type of port (IN)> - Status :

<(NO/NC)> - Sev. : <severity for the User Input>

OUT:

<Type of port (OUT)> - Status :

<(NO/NC)> - Source <(A-alarm, B-Alarm, A or B Alarm - P-mark - remote)>

NO = Normally Open NC = Normally Closed

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

User9_IO_Config

User11 I\O Config Text string User Input/output port configuration Format as described in

User9_IO_Config User12 I\O Config Text string User Input/output port configuration

IN:

<Type of port (IN)> - Status :

<(NO/NC)> - Sev : <severity for the User Input>

OUT:

<Type of port (OUT)> - Status :

<(NO/NC)> - Source Remote NO = Normally Open

NC = Normally Closed

Digital Service Channel1_1

Text string Digital Service Channel configuration:

ID <Terminal id on digital service channel 1> - Alm : <service channel alarm (ON/OFF)> - Conn

<connection point for the service channel>

ID E00a - Alm : ON - Conn. xxx

Digital Service Channell_2

Text string Digital Service Channel configuration:

Format as described in Dig_Service_Chan1_1

Digital Service

Channel1_ 3 Text string Digital Service Channel configuration:

Format as described in Dig_Service_Chan1_1

Digital Service

Channel1_ 4 Text string Digital Service Channel configuration:

Format as described in Dig_Service_Chan1_1

Digital Ana Service

Channel2_ 1 Text string Service channel configuration Digital:

ID <Terminal id on digital service Analog:

ServiceOn Microwave Element Manager - Operator Guide 2BElement Management User Interface

Fieldname Format Description Example

channel 2> - Alm : <service channel alarm> - Conn <connection point for the service channel>

Analog (SAU exp 2 only):

ID <Terminal id on analog service channel 2> -Conn. <Connect terminal on analog service channel on/off> - Tel. <Telephone. Number>

- Conn BR1 : <ON/OFF> - BR1 Out

< output level on the branching port>- Conn BR2 : <ON/OFF> - BR2 Out < output level on the branching port>

Digital Ana Service Channel2_ 2

Text string Service channel configuration Format as described in

Dig_Ana_Service_Chan2_1

Digital Ana Service Channel2_ 3

Text string Service channel configuration Format as described in

Dig_Ana_Service_Chan2_1

Digital Ana Service

Channel2_ 4 Text string Service channel configuration Format as described in

Dig_Ana_Service_Chan2_1

Site ID Text string Site_ID from NE terminal properties Hop Side ID Text string Hop_Side_ID from NE terminal

properties

Hop ID Text string Hop_ID ID from NE terminal

properties

Far Hop Side ID Text string Far_Hop_Side_ID from NE terminal

properties

Subnet ID Text string Sub-network id of the terminal Description Text string Description from NE terminal

properties

Traffic Rate

Description Text string Traffic_Rate_Description from NE

terminal properties

Can be:

0 Validity Text string Value 1 if collection valid, 0

otherwise

1

MIN-LINK E MICRO DATA

Table 11 MINI-LINK E Micro Data

Fieldname Format Description Example

Terminal ID Text string ID of the MINI-LINK Terminal E00A

In document Ericsson SOM Operator Guide (Page 99-102)