Experts in Spray Technology
Spray
Nozzles ControlSpray AnalysisSpray FabricationSpray
TankJet
®Tank Cleaning
Products
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Optimizing Tank Cleaning Operations
Optimizing Tank
Cleaning Operations
Choosing the best way to thoroughly clean your tanks
while minimizing use of costly chemicals, water and
manual labor can be challenging. There are several
things you can do to maximize the performance of
your tank cleaning equipment. We’ve included
optimization tips and guidelines in this bulletin
to help you achieve optimal cleaning efficiency.
GeTTinG STarTed
If you are cleaning your tanks manually
Changing to an automated method will yield many benefits:
• More consistent, thorough cleaning
• Improved worker safety by removing contact with
hazardous chemicals
• Faster cleaning – downtime is minimized and tanks
are returned to service more quickly
• Reduced use of water, chemicals and lower
wastewater disposal costs
• Workers can be deployed to other tasks
If you are currently using tank cleaning
nozzles or a tank cleaning machine
You may be able to improve cleaning efficiency by making
some simple changes or using different equipment.
Technology advancements have made it easier to remove
stubborn residues, shorten cleaning cycle times and
achieve higher levels of automation.
The first step to optimizing tank cleaning
is to audit your operations.
• How many tanks require cleaning and what is the
diameter, length and height of each?
• Are there obstructions in your tanks such as agitators
or mixers?
• Are there certain areas that need more cleaning than
others such as skim lines?
• What residue needs to be removed? Is it sticky?
Or is it easily rinsed away?
• Are cleaning agents required or is water sufficient?
Is it necessary to heat the cleaning liquid?
• What problems are you experiencing with your current
cleaning method?
Equipped with the answers to these questions,
you should be ready to start evaluating your options.
Optimizing Tank Cleaning Operations
SeleCTinG The riGhT equipmenT
The chart below shows all of our tank cleaning products and the maximum tank diameter each unit can clean.
The maximum tank diameter is defined as the total distance the spray can travel to tank walls assuming the
unit is positioned in the center of the tank. The closer the nozzle is to the tank wall, the greater the impact.
The chart also shows recommended minimum tank diameters. It is possible to use some tank cleaners in
smaller tanks than recommended, but consider the size of the unit and the liquid volumes.
Maximum Tank Diameter
Feet 0.5 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 30 40 50 60 70 80 90 100 Meters 0.2 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3 3.7 4.3 4.9 5.5 6.1 9.1 12 15 18 21 24 27 30 TankJet® 360/363 TankJet 180 TankJet AA290 TankJet AA190-HP5 TankJet 80 TankJet 65
TankJet AA190 and AA190H TankJet 75 TankJet 27500 and 27500R TankJet 12900 TankJet D26984 TankJet D40159 TankJet 28500 and 28500R TankJet 63225 TankJet D41800E TankJet 6353 and 6353-MFP TankJet AA090 TankJet 18250A TankJet 30473 TankJet D41892 TankJet D41990 TankJet 21400A TankJet VSM TankJet 23240 TankJet 3150 TankJet 36640 TankJet 15498
High Impact Cleaning Medium Impact Cleaning Low Impact Cleaning Rinsing up to 100’ up to 80’ up to 80’ up to 80’ up to 50’ up to 40’ up to 34’ up to 30’ up to 25’ up to 22’ up to 20’ up to 20’ up to 18’ up to 13’ up to 12’ up to 10’ up to 8’ up to 8’ up to 8’ up to 6.5’ up to 6.5’ up to 5’ up to 5’ up to 3’ up to 3’ up to 3’ up to 2’
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Optimizing Tank Cleaning Operations
SeleCTinG The riGhT equipmenT
The chart below shows all of our tank cleaning products and the maximum tank diameter each unit can clean.
The maximum tank diameter is defined as the total distance the spray can travel to tank walls assuming the
unit is positioned in the center of the tank. The closer the nozzle is to the tank wall, the greater the impact.
The chart also shows recommended minimum tank diameters. It is possible to use some tank cleaners in
smaller tanks than recommended, but consider the size of the unit and the liquid volumes.
Maximum Tank Diameter
Feet 0.5 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 30 40 50 60 70 80 90 100 Meters 0.2 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3 3.7 4.3 4.9 5.5 6.1 9.1 12 15 18 21 24 27 30 TankJet® 360/363 TankJet 180 TankJet AA290 TankJet AA190-HP5 TankJet 80 TankJet 65
TankJet AA190 and AA190H TankJet 75 TankJet 27500 and 27500R TankJet 12900 TankJet D26984 TankJet D40159 TankJet 28500 and 28500R TankJet 63225 TankJet D41800E TankJet 6353 and 6353-MFP TankJet AA090 TankJet 18250A TankJet 30473 TankJet D41892 TankJet D41990 TankJet 21400A TankJet VSM TankJet 23240 TankJet 3150 TankJet 36640 TankJet 15498
High Impact Cleaning Medium Impact Cleaning Low Impact Cleaning Rinsing
Comparing the Options
Your final decision will be determined by tank size
and level of cleaning required. However, here are a
few more things to keep in mind as you work through
the selection process:
High impact cleaning is required to
remove stubborn residues such as
layers of a dried substance. Tank
cleaners in this category generally
use high pressure and/or high flow
and spin at slow rotational speeds
to maintain high impact. Solid stream
nozzles are used to maximize impact.
Medium impact cleaning is required
when good impingement is needed to
remove residues. Tank cleaners that
provide medium impact generally use
solid stream nozzles at medium flows
and pressures. Rotational speed is
slightly faster than high impact tank
cleaners but much slower than
free-spinning nozzles to ensure
adequate impact on target areas.
Low impact cleaning is used for light
cleaning when some impact is required.
Low flow/medium pressure and high
flow/low pressure nozzles are used to
achieve low impact cleaning. These
nozzles include rotating flat spray
nozzles or stationary full cone types.
Rinsing is used when distributing
cleaning solution throughout the tank
without impact provides sufficient
cleaning. Rinsing nozzles are typically
free-spinning or stationary spray balls.
up to 100’ up to 80’ up to 80’ up to 80’ up to 50’ up to 40’ up to 34’ up to 30’ up to 25’ up to 22’ up to 20’ up to 20’Optimizing Tank Cleaning Operations
Six Key SpeCifiCaTiOn GuidelineS
Once you’ve determined which type of tank cleaner or
nozzles may be suitable, there are a few other factors to
evaluate to ensure you’re going to get the cleaning
performance you need. Here are a few guidelines to
keep in mind as you start to select a specific unit.
Spray distance
Spray distance, sometimes referred to as “throw”, is the
distance between the spray exiting the nozzle orifice to the
spray hitting the target surface. The spray coming from the
nozzle should reach the walls of the tank vessel. Spray that
reaches the tank surface may not clean heavily soiled areas.
The spray loses impact the farther away it gets from the
nozzle. Adequate pressure should be supplied to the
nozzle to ensure the cleaning liquid is applied with
enough impact to remove the residue.
Spray distance is usually expressed in
terms of tank diameter. If your tank is
20 ft. (6 m) in diameter and 40 ft. (12 m)
tall, understand that you will need two
tank cleaners that can clean 20 ft.
(6 m) or one that can clean up
to 40 ft. (12 m).
Impact
The characteristics of the residue will determine how
much impact is required to remove it. If you’re not sure,
ask for assistance. We have impact data available for
many products and decades of experience.
Keep in mind that you can increase impact by increasing
flow rate or by increasing pressure. Increasing flow
rate is far more effective. Doubling flow rate increases
impact by as much as 100% while doubling pressure
provides a 40% increase.
However, the best approach
is to select the tank cleaning product that has adequate
impact to ensure optimal cleaning efficiency.
Relative Impact
Flow Rate Pressure Relative Impact
13 gpm
(50 l/min)
(3 bar)
45 psi
1.0
13 gpm
(50 l/min)
(6 bar)
90 psi
1.4
26 gpm
(100 l/min)
(3 bar)
45 psi
2.0
Another consideration is the effect of rotational speed on
impact. Faster rotational speeds can compromise impact
and efficiency. The spray rotates so fast that energy
dissipates and the spray pattern deteriorates before it
hits the tank surface. In some operations, you may be
able to eliminate using hot water by increasing impact.
This is dependent on the residue to be removed.
Increasing impact instead of heating your
cleaning solution can save thousands of dollars
annually by decreasing energy costs.
20 ft.
(6 m)
20 ft.
(6 m)
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Optimizing Tank Cleaning Operations
Full Cone for Low-Impact Flat Fan for Medium-Impact Solid Stream for High-Impact
Flow rate
Operating at the lowest possible flow rate will help
keep operating costs down. Less liquid, effluent for
disposal and energy will be consumed. A general
guideline is to use between 0.2 gal/min/ft
2(7 l/min/m
2)
and 0.4 gal/min/ft
2(15 l/min/m
2). This guideline generally
applies to stationary nozzles where all the surfaces
of the tank are sprayed at the same time. Nozzles
that rotate usually contact part of the tank at one
time and can operate at lower flows.
Spray pattern
Solid stream sprays provide the greatest impact,
followed by flat fan and full cone sprays.
Materials
Most tank cleaning nozzles are constructed of stainless
steel because of its durability and resistance to high
temperatures. For operations where corrosion is a
concern, choose nozzles made of PTFE or PVDF. Make
sure units with seals and o-rings are made of materials
compatible with the cleaning solution.
Coverage
Spray coverage from tank cleaning nozzles range from
65° to 360°. You may need to use more than one nozzle
to reach all areas of the tank especially if there is
equipment in the tank such as a mixer or agitator.
Spray coverage
65°
240°
120°
260°
180°
270°
Optimizing Tank Cleaning Operations
OpTimizinG perfOrmanCe
Keep tank cleaning nozzles and fluid-driven
machines free of debris by using strainers
Particulates in the liquid can clog nozzles, stop rotation
and cause inadequate cleaning. Filtering the liquid with line
strainers can prevent clogging and extend the wear life of
downstream equipment.
• For fine straining, woven wire mesh screens provide very
small openings to strain particulates down to 200 mesh
(74 microns)
• The mesh screen should be made of stainless steel for
strength and corrosion resistance
• Be sure to keep an extra screen on hand for every strainer
to ensure trouble-free operation
See our bulletin on strainers for recommendations
on selecting strainers and mesh.
Ensure proper liquid flow by using lances
If fluid isn’t delivered efficiently and effectively to
the tank cleaning device or the nozzle isn’t precisely
positioned in the tank, cleaning performance will
be compromised.
• Evaluate your lance requirements when specifying
your tank cleaner or nozzle. Determine if a standard
lance or custom lance is required. Consider a custom
lance if you need to position nozzles so the spray impacts
directly on heavily soiled areas or skim lines or require
special connections, lengths or materials
• Working with a single supplier will ensure compatibility
and eliminate connection problems
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Optimizing Tank Cleaning Operations
Improve cleaning by changing
spray head position
Use an adjustable ball fitting to clean vessels in sections.
Clean the top half of the vessel; then lower the device and
clean the bottom half of the vessel and/or change the angle
to clean difficult locations.
Reduce the number of cleaning cycles
Simple adjustments to pressure and flow may enable
a reduction in the number of cycles needed for
thorough cleaning.
Recirculate and save
Consider recycling your cleaning solution if you aren’t using
hazardous materials and your water is free of debris.
Activate cleaning with the flip of a switch
Hard piping your tank cleaner in place can save time and
reduce labor costs. Consider permanently installing the
device as long as the material or temperature of the
material won’t damage the cleaning equipment.
Minimize striping
Motor- and fluid-driven tank cleaners provide 360° coverage.
However, the solid stream sprays do not overlap as they
rotate so there is a small distance between the sprays.
The greater the distance the nozzles are from the tank
walls, the greater the distance between the sprays. This
distance between the sprays causes a “striping” effect.
The best way to minimize striping is to use a three- or
four-nozzle hub rather than the standard two-nozzle hub.
Striping will be minimized.
Striping effect with
two-nozzle hub Striping effect with four-nozzle hub
Free tank cleaning evaluation
Once you’ve reviewed this bulletin, you should consider taking
advantage of our complimentary, on-site tank cleaning evaluation.
One of our tank cleaning specialists will visit your plant
and observe your operations.
• If tank cleaning nozzles are in use, we will inspect the nozzles
and evaluate the type, placement and position
• We will document flow rates, operating pressures, cleaning
fluids and residues being removed
• After the evaluation we will provide a written report summarizing
your current operations and recommendations to improve
cleaning efficiency
Contact your local sales engineer for more information.
Call 1.800.95.SPRAY or 1.630.665.5000
Optimizing Tank Cleaning Operations
abOuT SprayinG SySTemS CO.
Spraying Systems Co. is the world leader in spray technology.
It offers the broadest product line in the industry including
tank cleaning equipment, spray nozzles, spray controllers,
spray injectors and lances and research and testing
services. Founded in 1937 in Chicago, Illinois, the company
now has 10 manufacturing locations and 90 sales offices
around the world.
Spraying Systems Co. recently formed a strategic
alliance with Cloud-Sellers, a leader in tank cleaning
equipment. The alliance enables Spraying Systems Co.
to offer a wider range of products and Cloud-Sellers to
benefit from increased distribution.
The Cloud-Sellers products are now branded as part
of Spraying Systems Co.’s TankJet
®line.
Catalog 15 - Introduction 0211
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
quick reference Guide
Nozzle Max Tank Diameter ft (m) Operating Principle Operating Pressure psi (bar) Flow Rate Range gpm (l/min) Spray Coverage Min Tank Opening Size in (mm) Max Temperature °F (°C) TankJet
D41800E (3.7)12 Constant SpeedFluid Driven 30 - 230 (2 - 16) (12 - 128)2.7 - 33 360° 1.25 (32) (150)300
TankJet 6353 & 6353-MFP 10 (3.0) StationaryFixed (1.5 - 3.5)20 - 50 (35 - 301)8.9 - 80 360° (152)6 (100)212 TankJet AA090 8 (2.4) Motor Driven 100 - 500 (7 - 35) (5.7 - 28)1.5 - 7.3 360° (59)2.3 200 (93) TankJet 18250A Fluid Driven Reactionary Force 10 - 60 (1 - 4) (48 - 205)10.5 - 55 360° 2.22 (60) (177)350 TankJet 30473 Fluid Driven Reactionary Force 10 - 50 (0.7 - 4) (7.8 - 18)2.1 - 4.5 180° up/down, ~360° (25)1 200 (93) TankJet D41892 6.5 (2.0) Fluid Driven Reactionary Force 20 - 70 (1.4 - 5) (15.9 - 29)4.0 - 7.5 360° (37)1.5 (70)160 TankJet D41990 Fluid Driven Reactionary Force 15 - 60 (1 - 4) (9.5 - 28)2.5 - 7.3 180° up/down, 360° Thread: 1 (25); CIP version: 2 (50) 300 (149) TankJet 21400A 5 (1.5) Fluid Driven Reactionary Force 10 - 60 (1 - 4) (23 - 82)5.0 - 22 360° 2.25 (60) (177)350 TankJet
VSM StationaryFixed (0.7 - 10)10 - 150 (10.4 - 269)2.7 - 72 240° down (51)2 (93)200
TankJet 23240 3 (0.9) Fluid Driven Reactionary Force 20 - 200 (1.5 - 12) (14 - 79)3.5 - 22 Side Spray360°, 1.03 (26) (177)350 TankJet 3150 StationaryFixed 10 - 150 (1 - 10) (23 - 91)5.2 - 26 210°, 360° (51)2 (100)212 TankJet 36640 Fluid Driven Reactionary Force 10 - 60 (1 - 4) (3.4 - 7.9)0.8 - 2.2 Side Spray 1.03 (26) (93)200 TankJet 15498 (0.6)2 StationaryFixed 60 - 150 (5 - 10) 5.5 - 11.7 (23 - 43) 210°, 360° (51)2 (100)212
Catalog 15 - Quick Reference Guide 0211
quick reference Guide
Nozzle Max Tank Diameter ft (m) Operating Principle Operating Pressure psi (bar) Flow Rate Range gpm (l/min) Spray Coverage Min Tank Opening Size in (mm) Max Temperature °F (°C) TankJet®
360 100 (30) Fluid Driven Turbine (2.8 - 24)40 - 350 (113.5 - 1135.6)30 - 300 360° (158.7)6.25 (121)250
TankJet 180 80 (24.4) Fluid Driven Turbine (2.8 - 24) 40 - 350 (113.5 - 1135.6)30 - 300 180° 12.25 (311) (121)250 TankJet
AA290 Motor Driven (3.5 - 17)50 - 250 (85 - 757)22 - 200 360°
7.25 (184) for 2 nozzle; 8.25 (210) for 4 nozzle 200 (93) TankJet
AA190-HP5 Motor Driven 500 - 5000 (35 - 350) (18.4 - 246) 4.9 - 65 360°
3.75 (95) for 2- or 4-nozzle hub 350 (177) TankJet 80 50
(15.2) Fluid Driven Turbine (4.1 - 10.3)60 - 150 (189 - 473)50 - 125 360°
6.5 (165) for 2 nozzle; 12.5 (318) for 3 nozzle 250 (121) TankJet
65 (12.2)40 Fluid Driven Turbine (3.4 - 10.3)50 - 150 (114 - 568)30 - 150 360° (190) 7.5
250 (121); 500 (260) high-temperature version TankJet
AA190 (10.4)34 Motor Driven 100 - 1000 (7 - 70) (11.8 - 170)3.1 - 44
180°, 360° 3.75 (95) for 360°; 4.5 (114.3) for 180° 200 (93) TankJet 75 30 (9.1) Fluid Driven (3.5 - 20.7)50 - 300 (30 - 125)8 - 33 360° 3 (76.2) for 2 nozzle; 3.75 (95.2) for 4 nozzle 350 (121) TankJet 27500 & 27500R 25 (7.6) Fluid Driven Reactionary Force 10 - 50 (0.7 - 3.5) (15.3 - 1490)4 - 391 180° up/down, 270° up/down, 360° 2 - 7 (51 - 178) (93)200 TankJet 12900 (6.7)22 StationaryFixed (1.5 - 3.5)20 - 50 (280 - 1470)72 - 385 360° and custom spray angles 10 (254) (100)212 TankJet D26984 & D40159 20
(6.0) Constant SpeedFluid Driven 30 - 230 (2 - 16) (12 - 128)3.2 - 31
65° down, 120° down, 180° up/down, 260° up/down, 360° 2.25 (56) (70)160 TankJet 28500 & 28500R (5.5)18 Fluid Driven Reactionary Force 10 - 50 (0.7 - 3.5) (34 - 295)9 - 78 180° up/down, 270° up/down, 360° 2.5 - 4 (64 - 102) (93)200 TankJet 63225 13 (4) StationaryFixed (1 - 2.8)15 - 40 (83 - 192)22 - 51 360° (38 - 102)1.5 - 4 (204)400
SolutionS for tankS
Up to 100' (30 m) in Dia.
100'
(30 m) tank Dia. SprayTankJet
®
360
Fluid driven tank cleaner
TankJet 360
tank cleaner
for tanks up to
100’ (30 m) in dia.
TAnkJET
®360 FLuID DRIVEn TAnk CLEAnER
Ideal for Cleaning:
• Blenders
• Brewery tanks
• Food processing vats and tanks
• Petrochemical/chemical processing reactors
• Pulp storage chests
• Processing tanks
• Tanker trucks
• Wine vats
Spray Coverage
360°100'
(30 m) tank dia.High-impact, High-efficiency cleaning
for Hard-to-remove residues
Features and Benefits
• Outperforms other fluid driven tank cleaners with more
consistent impact over the entire pressure range
• High-impact cleaning results in shorter cycle times so
tanks are returned to service more quickly
• nozzles rotate 360° in horizontal and vertical planes
creating a crisscrossing pattern to thoroughly clean
tanks and remove the stickiest of residues
• Food-grade, oil-lubricated or flow-through gearbox designs
• Choice of dual- or triple-nozzle hubs
• no motors – TankJet 360 tank cleaners are fluid-driven
• Sleek and compact – fits in small tank openings
• Choice of standard clutch version or optional pin version.
With clutch version, nozzle hub easily rotates by hand for
insertion and removal from tank. Use pin version for
permanent or CIP installations. Optional external, self-rinse
nozzles available for both pin and clutch versions
• Lightweight for easy portability
• Customizable to your operation. TankJet 360 can be used
for high-concentration chemical recirculation cleaning
or low pressure, high-volume cleaning. All units are
built-to-order
• Built-in strainer minimizes clogging and extends wear life
• user-serviceable for easy maintenance
• For flow rates below 30 gpm (113.5 l/min) use
TankJet 363 tank cleaners with low flow patented
technology to reduce wastewater costs.
Contact your local sales engineer for more information
• Great value – TankJet 360 is competitively priced, provides
better performance and comes with the applications
expertise and support of the world’s leader
in spray technology
Try Before You Buy:
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Specifications
Max. tank dia.:
100’ (30 m)
Flow rate range:
30 to 300 gpm (113.5 to 1135.6 I/min)
Pressure range:
40 to 350 psi (2.8 to 24 bar)
Wash cycle time:
10 to 30 min
Max.
operating temp.:
250°F (121°C)
Min. tank
opening size:
Dual nozzle: 6.25” (15.9 cm)
Triple nozzle: 10.25” (26 cm)
Inlet conn.:
2” nPT (F) with 2-1/2”
quick-disconnect (M)
2” nPT (F) with 2-1/2” nST (nH)
hose thread (M)
2” BSPT (F) with 2-1/2”
quick-disconnect (M)
Materials of
construction:
Castings – 316 stainless steel
Gears – 17-4ph stainless steel
O-rings – self-lubricating
EPDM or Viton
®Seals – high-performance
spring-energized PTFE
Gear shaft bearing system –
PTFE or oilite bearing
All other metallurgy –
316 stainless steel
Weight:
25 lbs (11.3 kg)
Viton® is a registered trademark of DuPont Performance Elastomers.
TAnkJET
®360 FLuID DRIVEn TAnk CLEAnER
100'
(30 m)tank dia.
Catalog 15 - TankJet 360
Dual Nozzle Configuration
Triple Nozzle Configuration
13.3" (338.1 mm) 13.3" (338.1 mm) 6.25" (158.7 mm) MIN. OPENING 10.25" (260.3 mm) MIN. TANK OPENING
SolutionS for tankS
Up to 80' (24.4 m) in Dia.
80'
(24.4 m) tank Dia.TankJet
®
180
Fluid driven tank cleaner
TAnkJET
®180 FLuID DRIVEn TAnk CLEAnER
Ideal for Cleaning:
• Adhesive tanks
• Food processing vats and tanks
• Paint tanks
• Petrochemical/chemical processing reactors
• Processing tanks
• Sludge/wastewater tanks
Spray Coverage
180° Down
directional unit Provides
concentrated, High-impact cleaning
of Hard-to-remove residues
Features and Benefits
• Outperforms other fluid driven tank cleaners – more
consistent impact over the entire pressure range
• High-impact cleaning results in shorter cycle times so tanks
are returned to service more quickly
• Provides a concentrated cleaning stream that removes
difficult residues and heavy sludges from the bottom and
shadow areas of the tanks
• Ideal for open top tanks
• nozzles rotate on multiple axes to create a crisscrossing
pattern to thoroughly clean tanks and remove the stickiest
of residues
• Food-grade, oil-lubricated or flow-through gearbox designs
• no motors – TankJet 180 tank cleaners are fluid-driven
• Lightweight for easy portability
• Customizable to your operation. TankJet 180 can be used
for high-concentration chemical recirculation cleaning
or low pressure, high-volume cleaning. All units are
built-to-order
• TankJet 180 is designed with built-in strainer to minimize
clogging and for long wear life
• Great value – TankJet 180 is competitively priced,
provides better performance and comes with the
applications expertise and support of the world’s
leader in spray technology
80'
(24.4 m) tank dia.TankJet 180
tank cleaner
for tanks up to
80’ (24.4 m) in dia.
Try Before You Buy:
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Specifications
Max. tank dia.:
80’ (24.4 m)
Flow rate range:
30 to 300 gpm (113.5 to 1135.6 I/min)
Pressure range:
40 to 350 psi (2.8 to 24 bar)
Wash cycle time:
10 to 30 min
Max.
operating temp.:
250°F (121°C)
Min. tank
opening size:
12.25” (31.1 cm)
Inlet connection:
2” nPT (F) with 2-1/2”
quick-disconnect (M)
2” nPT (F) with 2-1/2” nST
hose thread (M)
2” BSPT (F) with 2-1/2”
quick-disconnect (M)
Materials of
construction:
Castings – 316 stainless steel
Gears – 17-4ph stainless steel
O-rings – self-lubricating
EPDM or Viton
®Seals – high-performance
spring-energized PTFE
Gear shaft bearing system –
PTFE or oilite bearing
All other metallurgy –
316 stainless steel
Height:
12.2” (31 cm)
Width including
nozzle housing:
12.125” (30.8 cm)
Weight:
29 lbs (13.17 kg)
Viton® is a registered trademark of DuPont Performance Elastomers.
TAnkJET
®180 FLuID DRIVEn TAnk CLEAnER
Catalog 15 - TankJet 180
80'
(24.4 m) tank dia.TankJet 180
tank cleaner
0211TankJet
®
aa290
Motor driven tank cleaner
consistent High-impact cleaning
day-in and day-out
Features and Benefits
• Dependable, durable motor-driven units provide powerful
cleaning and remove the most stubborn residues
• Customize to your cleaning operation. Choose:
– CE-rated air (AG) or explosion-proof (EP) electric motor
– Two- or four-nozzle hub
– 3’, 4’ or 6’ (.9, 1.2 or 1.8 m) shaft length
Plus, change flow rates through nozzle selection
or adjustments to inlet pressure
• Motor positioned outside of tank for longer life and fewer
failures due to exposure to harmful cleaning solutions
• Long-life construction features corrosion-resistant
316 stainless steel and PTFE fluoropolymer resin seals
• Optimum impact provided by 55430 series solid stream
nozzles: with stabilizer vanes that can be removed for
maintenance purposes
Lubricator assembly is included with the air
(AG) model only. Regular lubrication of the
air supply line will significantly increase the life of the air motor.
TAnkJET
®AA290 MOTOR DRIVEn TAnk CLEAnER
Ideal for Cleaning:
• Fermentation and yeast tanks and vats
• Flour silos
• Mixing tanks
• Paint tanks
Spray Coverage
360° Explosion-proof electric motor Air motorTankJet
AA290EP and
AA290AG tank
cleaners for
tanks up to 80’
(24.4 m) in dia.
80'
(24.4 m) tank dia.Specifications
Max. tank dia.:
80’ (24.4 m)
Flow rate range:
22 to 200 gpm (85 to 757 l/min)
Pressure range:
50 to 250 psi (3.5 to 17 bar)
Max. operating
temperature:
200°F (93°C)
Min. tank
opening size:
7.25” (184 mm) for two-nozzle hub
8.25” (210 mm) for four-nozzle hub
Spray coverage:
360°
Inlet conn.:
2” nPT or BSPT (F)
Flanges:
8” (203 mm) flange for two-nozzle hub
10” (254 mm) for four-nozzle hub
Motor:
Air, explosion-proof electric
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
Cycle Time Data –
Explosion-Proof Motor (EP)
Cycle Time Data – Air Motor (AG)
Dimensions and Weights – Air Motor (AG)
Dimensions and Weights –
Explosion-Proof Motor (EP)
Performance Data
Total Flow of Two Nozzles (Equal Capacity) gpm or l/min Liquid Inlet Pressure* Double flow rates when using four nozzles up to 200 gpm (752 l/min)
Nozzle No. (3.5 bar)50 psi 100 psi (7 bar) (10 bar)150 psi (15 bar)200 psi (17 bar)250 psi
55430-H3/4u-00100 22 (85) 32 (121) 39 (144) 45 (177) 50 (188)
55430-H3/4u-00200 45 (171) 63 (241) 77 (288) 89 (353) 100 (376)
55430-H3/4u-00250 56 (213) 79 (301) 97 (360) 112 (441) 125 (470)
55430-H3/4u-00350 78 (298) 111 (422) 136 (505) 157 (618) 175 (658)
55430-H3/4u-00400 89 (341) 126 (482) 155 (577) 179 (706) 200 (752) *Note: Liquid inlet pressure measured near inlet connection of tank cleaner.
Approx.
Speed (rpm) Supply Complete Cycle (min.)Approx. Time for One
4 120 VAC60 Hz 16
Model no. Extension Length Overall Length Weight with 8"
Flange Weight with 10" Flange AA290AG_F3 (0.9 m) 3' 60-7/8" (1.5 m) (25.5 kg)56 lbs (28.7 kg)63 lbs AA290AG_F4 (1.2 m) 4' 72-7/8" (1.8 m) (27.3 kg)60 lbs (30.5 kg)67 lbs AA290AG_F6 (1.8 m) 6' 96-7/8" (2.5 m) (31.4 kg)69 lbs (34.6 kg)76 lbs
Model no. Extension Length Overall Length Weight with 8"
Flange Weight with 10" Flange AA290E_F-EP3 (0.9 m) 3' 61-3/4" (1.6 m) (30.1 kg)66 lbs (33.2 kg)73 lbs AA290E_F-EP4 (1.2 m) 4' 73-3/4" (1.8 m) (31.9 kg)70 lbs (35.0 kg)77 lbs AA290E_F-EP6 (1.8 m) 6' 97-3/4" (2.5 m) (36.0 kg)79 lbs (39.1 kg)86 lbs Air Pressure psi (bar) Air Consumption scfm (l/sec) Approx. Speed (rpm) Approx. Time
for One Complete Cycle (min.) 50 psi
(3.4 bar) (17.2 bar)250 psi (3.4 bar)50 psi (17.2 bar)250 psi
12 (0.83) 4.7 (2.2) 6 2 11 32
14 (0.97) 5.4 (2.5) 8 4 7 17
16 (1.10) 6.3 (3.0) 10 8 6 8
18 (1.24) 7.1 (3.4) – 9 – 7
Spray Head Tank Diameter Opening with Two Nozzles
7.25" (184 mm)Opening
1.6" (40 mm)
Spray Head Tank Diameter Opening with Four Nozzles
1.96" (50 mm)
8.25" (210 mm) Opening
TAnkJET
®AA290 MOTOR DRIVEn TAnk CLEAnER
80'
(24.4 m)TAnkJET
®AA290 MOTOR DRIVEn TAnk CLEAnER
80'
(24.4 m)tank dia.
Ordering Information
tankJet aa290ag tank cleaner
tank cleaner
nozzle no.
aa290ag
8F
–
3
–
2
+
55430-H
3/4
u
–
316SS
–
00100
I I I I I I I I I Tank Cleaner Type 8"Flange ExtensionLength Hub Type (No. of Nozzles) Nozzle Type Prefix Nozzle Inlet Conn. Nozzle
Type MaterialCode CapacitySize
Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections.
tankJet aa290e-eP tank cleaner
tank cleaner
nozzle no.
aa290e 10F –
eP
–
3
–
4
+ 55430-H 3/4
u
– 316SS – 00100
I I I I I I I I I I Tank Cleaner Type 10"Flange Explosion-proofMotor ExtensionLength Type Hub (No. of Nozzles) Nozzle Type Prefix Nozzle Inlet Conn. Nozzle
Type MaterialCode CapacitySize
Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections.
8” flange
Bolt Circle Dia. O.D. Bolt Hole Dia.Flange Size Flange O.D. Bolt Circle Diameter no. of Flange Holes Bolt Hole Diameter Thickness
8” flange 13.5” 11.75” 8 0.875” 3/8” 10” flange 16” 14.25” 12 1.00” 3/8” Bolt Circle Dia. Bolt Hole Dia.
10” flange
O.D.Flange Specifications
Catalog 15 - AA290 02111.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TankJet
®
80
Fluid driven Tank Cleaner
TankJeT
®80 Fluid driven Tank Cleaner
Ideal for Cleaning:
• Brewery tanks
• Chemical vessels
• Fermenters
• Food and dairy tanks
• Tanker trucks
Spray Coverage
360°
Powerful, reliable Cleaning of
Tanks up to 50’ (15.2 m) in dia.
Features and Benefits
• Ideal for cleaning large tanks, tanker trucks and
fermenters with minimal maintenance cost
• Solid stream nozzles rotate in multiple axes to
provide complete 360° coverage of entire
tank every 45 revolutions
• Fluid driven, turbine driven with external gears
indexes the nozzles with each rotation. Slow,
rotating speed provides excellent dwell time
on tank surface and improves cleaning
• Simple design is easy to maintain
• Mount permanently or move from tank to tank
• Available with two or three nozzle hub
• Lightweight – weighs only 15 lbs. (6.8 kg)
• Self -cleaning, flow-through design
• Optional external CIP nozzle helps clean unit
and drop pipe
50'
(15.2 m)Tank dia.
Specifications
Flow rate range:
Two-nozzle version: 50 to 95 gpm
(189 to 360 l/min)
Three-nozzle version: 60 to 125 gpm
(227 to 473 l/min)
Pressure range:
60 to 150 psi (4.1 to 10.3 bar)
Max. operating
temperature:
250°F (121°C)
Rotation speed:
3 to 20 RPM
Min. tank
opening size:
Two-nozzle version: 6.5” (165.1 mm)
Three-nozzle version: 12.5” (317.5 mm)
Spray coverage:
360°
Inlet conn.:
1-1/2” NPT or BSPT (F)
Weight:
15 lbs. (6.8 kg)
Materials:
316SS, PTFE, UHMW-PE
Nozzles:
Two: .375” (9.5 mm) or .438”
(11.1mm) orifice
Three: .313” (7.8 mm) or .375”
(9.5 mm) orifice
TankJet 80 tank cleaners for
tanks up to 50’ (15.2 m) in dia.
Units are available withtwo or three nozzles. Both versions can be equipped with optional clean-in place nozzle as shown on the right.
TankJeT
®80 Fluid driven Tank Cleaner
Catalog 15 - TankJet 8050'
(15.2 m) Tank dia. 0211 Nozzle No. Capacity gpm (l/min) 60 psi(4.1 bar) (4.8 bar)70 psi (5.5 bar)80 psi (6.2 bar)90 psi (6.9 bar)100 psi (7.6 bar)110 psi 120 psi (8.3 bar) (9.0 bar)130 psi (9.7 bar)140 psi (10.3 bar)150 psi TJ80-2-375 50 (189) 57 (216) 62 (235) 65 (246) 68 (257) 73 (276) 76 (288) 79 (299) 83 (314) 86 (326) TJ80-2-375CIP TJ80-2-438 63 (238) 67 (254) 72 (273) 75 (284) 79 (299) 83 (314) 85 (322) 88 (333) 92 (348) 95 (360) TJ80-2-438CIP TJ80-2-438SR TJ80-3-313 60 (227) 63 (238) 65 (246) 68 (257) 73 (276) 76 (288) 78 (295) 82 (310) 85 (322) 88 (333) TJ80-3-313CIP TJ80-3-375 94 (356) 97 (367) 100 (379) 103 (390) 107 (405) 111 (420) 114 (431) 118 (447) 121 (458) 125 (473) TJ80-3-375SR TJ80-3-375SRCIP
Performance Data
TankJet 80-2
TankJet 80-3
Dimensions
Ordering Information
TankJet 80 Tank Cleaning nozzle
TJ80
__* –
2
– 375
Sr
CiP
i i i i i i
Model
No. Inlet Type Model Type Nozzle Orifice Size
Slow
Rotation Clean In Place * Add B for BSPT connections. If NPT connection, leave blank.
3.7” (94 mm) 12.75” (323.9 mm) 6.5” (165.1 mm) 12.75” (323.9 mm) 11.75” (298.5 mm) 12.5” (317.5 mm)
Typically used in the brewery industry, clean-in place (CIP) nozzles clean unit and down pipe.
SolutionS for tankS
Up to 40' (12 m) in Dia.
40'
(12 m) tank Dia. SprayTankJet
®
65
FLUID DRIVEN TANK CLEANER
TankJeT
®65 FLUID DRIVen Tank CLeaneR
Thorough, Efficient, Dependable Cleaning
Features and Benefits
• Solid stream nozzles rotate in multiple axes to
provide complete 360° coverage of entire
tank every 45 revolutions
• Four-nozzle hub provides tight cleaning pattern
and fast cycle times
• High-temperature version made of all stainless steel can
withstand temperatures up to 500°F (260°F)
• Fluid driven, turbine driven with external gears indexes the
nozzles with each rotation. Slow, rotating speed provides
excellent dwell time on tank surface
• Simple self-cleaning, flow-through design
• Easy to maintain – no internal reduction gears
• Can be permanently mounted or moved from tank to tank
• Lightweight – weighs only 11.75 lbs. (5.3 kg)
Ideal for cleaning:
• Brew kettles
• Chemical processing tanks
• Dairy vessels
• Food processing vats
• Spray dryers
• Tanker trucks
Spray Coverage
360°40'
(12.2 m) Tank Dia.Specifications
Max. tank dia.:
40’ (12.2 m)
Flow rate range:
Standard version: 30 to 100 gpm
(114 to 379 l/min)
High-temperature version:
65 to 150 gpm (246 to 568 l/min)
Pressure range:
50 to 150 psi (3.4 to 10.3 bar)
RPM range:
5 to 40 RPM
Max. operating
temperature:
Standard version: 250°F (121°C)
High-temperature version:
500°F (260°C)
Min. tank
opening size:
7.5” (191 mm)
Spray coverage:
360°
Inlet conn.:
1-1/2” NPT or BSPT (F)
Materials:
Standard version: Stainless steel,
PTFE, UHMW-PE, nylon
High-temperature version:
all stainless steel
Nozzles:
Four: .250 (6.4 mm) or .313 (7.9 mm)
or .375 (9.5 mm)
TankJet 65 tank
cleaners for tanks
up to 40’ (12.2m) in dia.
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TankJeT
®65 FLUID DRIVen Tank CLeaneR
Model No.
Capacity gpm (l/min) 50 psi
(3.4 bar) (4.8 bar)70 psi (6.2 bar)90 psi (6.9 bar)100 psi (7.6 bar)110 psi (9.0 bar)130 psi (10.3 bar)150 psi
TJ65-250 30 (114) 39 (148) 45 (170) 49 (185) 53 (201) 58 (220) 63 (238) TJ65-313 51 (193) 60 (227) 70 (265) 74 (280) 79 (299) 85 (322) 92 (348) TJ65-375 58 (220) 69 (261) 78 (295) 83 (314) 88 (333) 94 (356) 100 (379) TJ65-250-HT 65 (246) 78 (295) 90 (341) 96 (363) 100 (379) 109 (413) 116 (439) TJ65-313-HT 67 (254) 83 (314) 97 (367) 103 (390) 107 (405) 117 (443) 126 (477) TJ65-375-HT 86 (326) 105 (397) 119 (450) 125 (473) 130 (492) 143 (541) 150 (568)
Performance Data
Ordering Information
TankJet 65 Tank Cleaner
TJ65
__*
–
375
–
HT
I I I I
Model
No. Inlet Type Nozzle Orifice Size Temperature High
* Add B for BSPT connections. If NPT connection, leave blank.
Dimensions
40'
(12.2 m) Tank Dia. Catalog 15 - TankJet 65 7.5” (190.5 mm) 0211 10.25” (260.4 mm) 6.63” (168.4 mm)TankJet
®
aa190
Motor driven tank cleaner
TAnkJET
®AA190 MOTOR DRIVEn TAnk CLEAnER
Specifications
Max. tank dia.:
25’ (7.6 m) for standard versions;
34' (10.4 m) for high-presure versions
Flow rate range:
3.1 to 44 gpm (11.8 to 170 l/min)
for standard versions;
7 to 20 gpm (26 to 78 l/min) for
high-pressure versions
Pressure range:
100 to 500 psi (7 to 35 bar) for standard
versions; high-pressure versions up
to 1000 psi (70 bar)
Max. operating
temperature:
200°F (93°C)
Min. tank
opening size:
3.75” (95 mm) for units providing 360°
coverage; 4.5” (114.3 mm) for units
providing 180° coverage
Spray coverage:
360° or 180°
Inlet conn.:
1” nPT or BSPT (F)
Motor:
Air, electric, explosion-proof electric
Shaft lengths:
3’, 4’ or 6’ (.9, 1.2 or 1.8 m)
Motorized units Provide thorough, Quick
cleaning and trouble-Free operation
Features and Benefits
• Versatile high-impact tank cleaner provides efficient,
consistent, reliable cleaning with virtually no maintenance
• Many options allow easy customization for
your cleaning operation. Choose:
– Variable speed CE-approved air (AG), electric (E)
or explosion-proof (EP) electric motor
– Standard versions that operate at pressures up
to 500 psi (35 bar)
– High-pressure versions that operate at pressures
up to 1000 psi (70 bar) for higher impact
– 360° or 180° coverage
– 3’, 4’ or 6’ (.9, 1.2 or 1.8 m) shaft length
• Flange type – standard, 150# raised face or sanitary
tri-clamp flange
• Motor is positioned outside the tank away from
harmful caustics
• Lightweight – can be installed permanently or easily
moved from tank to tank
• Long wear life materials of construction – corrosion-resistant
316 stainless steel and PTFE fluoropolymer resin seals
Ideal for Cleaning:
• Chemical reactors
• Food processing tanks and vats
• Paint tanks
• Pharmaceutical processing vessels
• Process tanks
• Tanker trucks
Spray Coverage
360°180°
34'
(10.4 m) tank dia. TankJet AA190EP tank cleaners feature an electric, explosion-proof motor and provide 360° coverage TankJet AA190DAG tank cleaners provide 180° coverage and are available in standard and high-pressure versions TankJet AA190AG tank cleaners provide 360° coverage and are available in standard and high-pressure versionsTankJet AA190 tank cleaners
for tanks up to 34’ (10.4 m) in dia.
Lubricator assembly is included with the air
(AG) model only. Regular lubrication of the
air supply line will significantly increase the life of the air motor.
1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TAnkJET
®AA190 MOTOR DRIVEn TAnk CLEAnER
Total Flow of Two Nozzles (Equal Capacity) gpm or l/min Liquid Inlet Pressure*
Nozzle No. 100 psi (7 bar) (15 bar)200 psi (20 bar)300 psi (30 bar)400 psi (35 bar)500 psi (50 bar)**700 psi (70 bar)**1000 psi
1/4MEG-0010 3.1 (11.8) 4.4 (17.3) 5.4 (20) 6.3 (24) 7.0 (26) 8.2 (32) 9.8 (38) 1/4MEG-0015 4.7 (17.9) 6.6 (26) 8.1 (30) 9.4 (37) 10.5 (40) 12.4 (48) 14.9 (57) 1/4MEG-0020 6.2 (24) 8.8 (35) 10.8 (40) 12.4 (49) 13.9 (53) 16.4 (63) 19.6 (75) 1/4MEG-0025 7.7 (29) 10.9 (43) 13.3 (50) 15.4 (61) 17.2 (66) 20 (78) – 1/4MEG-0030 9.1 (35) 12.9 (51) 15.8 (59) 18.2 (72) 20 (78) – – 1/4MEG-0035 10.5 (40) 14.8 (59) 18.1 (68) 21 (83) 23 (90) – – 1/4MEG-0040 11.8 (45) 16.7 (66) 20 (76) 24 (93) 26 (101) – – 1/4MEG-0050 14.2 (54) 20 (79) 25 (92) 28 (112) 32 (121) – – 1/4MEG-0060 16.4 (63) 23 (92) 28 (102) 33 (129) 37 (140) – – 1/4MEG-0070 18.3 (70) 26 (102) 32 (118) 37 (144) 41 (156) – – 1/4MEG-0080 19.9 (76) 28 (111) 34 (128) 40 (157) 44 (170) – –
*Note: Flow rates tabulated above include pressure drop through unit.
** High-pressure versions only. For additional performance data on high-pressure units, contact your local representative.
Performance Data – AA190 Tank Cleaners
Motor
Type FrequencyAC Speed(rpm) Current(amps) (watts)Power
Approx. Time for
One Complete Cycle (min.) Electric 50 Hz. 3.1 .39 41 11 60 Hz. 3.8 .33 34 9 Explosion-Proof 50 Hz. 0.8 0.3 33 44 60 Hz. 1.0 0.3 28 35
Cycle Time Data – Electric Motor (E and EP)
Air
Pressure ConsumptionAir Approx. Speed (rpm) Complete Cycle (min.)Approx. Time for One
psi
(bar) (l/min)scfm (3.45 bar)50 psi (34.48 bar)500 psi (3.45 bar)50 psi (34.48 bar) 500 psi
6 (0.41) 3.74 (105.8) 4 1 8.8 35
8 (0.55) 4.72 (133.6) 7 4 5.0 8.8
10 (0.69) 5.84 (65.3) 10 8 3.5 4.4
*For standard and high-pressure versions.
Cycle Time Data – Air Motor* (AG, DAG)
AA190 Spray Head Tank Diameter Opening
with Two Nozzles
1.3" (33 mm) 3.75" (95 mm) Opening 3.6" (85 mm) 3.0" (76 mm)
AA190D Spray Head Tank Diameter Opening
with Two Nozzles
3.4" (86.3 mm) 4.4" (112.5 mm) 4.75" (114.3 mm) Opening 4.5" DIA (114.3 mm) 2.0" DIA (5.8 mm) 2.6" (66 mm) AA090
34'
(10.4 m) tank dia.TAnkJET
®AA190 MOTOR DRIVEn TAnk CLEAnER
Model no. Extension Length Overall Length Weight
AA190AG, AA190AGH* 3' (0.9 m) 54-1/4" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-1/2 lbs. (8.4 kg) AA190DAG, AA190DAGH* 3' (0.9 m) 55" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 67” (1.7m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 91” (2.3 m) 18-1/2 lbs. (8.4 kg) AA190E 3' (0.9 m) 48-7/8" (1.2 m) 14 lbs. (6.4 kg) 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-1/2 lbs. (8.4 kg) AA190E-EP 3' (0.9 m) 51-7/8" (1.3 m) 14 lbs. (6.4 kg) 4' (1.2 m) 63-7/8" (1.6 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 87-7/8" (2.2 m) 18-1/2 lbs. (8.4 kg) *H indicates high-pressure version.
Model no. Extension Length Overall Length Weight
AA190AG3F 3' (0.9 m) 54-1/4" (1.4 m) 24-1/2 lbs. (11.1 kg) 4' (1.2 m) 66-1/4" (1.7 m) 26 lbs. (11.8 kg) 6' (1.8 m) 90-1/4" (2.3 m) 29 lbs. (13.2 kg) AA190E3F 3' (0.9 m) 48-7/8" (1.2 m) 24-1/2 lbs. (11.1 kg) 4' (1.2 m) 60-7/8" (1.5 m) 26 lbs. (11.8 kg) 6' (1.8 m) 84-7/8" (2.1 m) 29 lbs. (13.2 kg) AA190AG4F 3' (0.9 m) 51-7/8" (1.3 m) 29-1/2 lbs. (13.4 kg) 4' (1.2 m) 63-7/8" (1.6 m) 31 lbs. (14.1 kg) 6' (1.8 m) 87-7/8" (2.2 m) 34 lbs. (15.4 kg) AA190AE4F 3' (0.9 m) 54-1/4" (1.4 m) 29-1/2 lbs. (13.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 31 lbs. (14.1 kg) 6' (1.8 m) 90-1/4" (2.3 m) 34 lbs. (15.4 kg)
Dimensions and Weights
Dimensions and Weights
See Accessories Section for Information on Adjustable Flanges, Mounting Kits and Tank Cleaner Adapters.
Standard Three-Prong
Mounting Flange
aa190 With Standard three-Prong Flange
tank cleaner
nozzle no.
aa190dagH –
3
+ 1/4 Meg – 0010
I I I I I
Tank Cleaner
Type ExtensionLength Conn.Inlet Nozzle Type Capacity Size
150# Raised Face Flange
Available in 3" and 4".
aa190 With 150# raised Face Flange
tank cleaner
nozzle no.
aa190ag
3F –
3
+ 1/4 Meg – 0010
I I I I I I Tank Cleaner Type 150# Raised Face Flange ExtensionLength Conn.Inlet NozzleType CapacitySize
Ordering Information
Ordering Information
34'
(10.4 m)1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TAnkJET
®AA190 MOTOR DRIVEn TAnk CLEAnER
34'
(10.4 m)tank dia.
Sanitary
Tri-Clamp Flange
Available in 3", 4" and 6".
aa190 With Sanitary tri-clamp Flange
tank cleaner
nozzle no.
aa190ag
3SF –
3
+ 1/4 Meg – 0010
I I I I I I Tank Cleaner Type Sanitary Tri-Clamp Flange ExtensionLength Conn.Inlet NozzleType CapacitySize
Note: The 3" sanitary flange has a modified hub assembly that can fit through a 2.75" opening with nozzles orientated in vertical position.
Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections.
Ordering Information
Model no. Extension Length Overall Length Weight
AA190AG3SF 3' (0.9 m) 54-1/4" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-1/2 lbs. (8.4 kg) AA190E3SF 3' (0.9 m) 48-7/8" (1.2 m) 14 lbs. (6.4 kg) 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-1/2 lbs. (8.4 kg) AA190AG4SF 3' (0.9 m) 54-1/4" (1.4 m) 14-1/4 lbs. (6.5 kg) 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-3/4 lbs. (8.5 kg) AA190E4SF 3' (0.9 m) 48-7/8" (1.2 m) 14-1/4 lbs. (6.5 kg) 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-3/4 lbs. (8.5 kg) AA190AG6SF 3' (0.9 m) 54-1/4" (1.4 m) 17 lbs. (7.7 kg) 4' (1.2 m) 66-1/4" (1.7 m) 18-1/2 lbs. (8.4 kg) 6' (1.8 m) 90-1/4" (2.3 m) 21-1/2 lbs. (9.8 kg) AA190E6SF 3' (0.9 m) 48-7/8" (1.2 m) 17 lbs. (7.7 kg) 4' (1.2 m) 60-7/8" (1.5 m) 18-1/2 lbs. (8.4 kg) 6' (1.8 m) 84-7/8" (2.1 m) 21-1/2 lbs. (9.8 kg)
Dimensions and Weights
See Accessories Section for Information on Adjustable Flanges, Mounting Kits and Tank Cleaner Adapters.
Catalog 15 - AA190 0211
TankJet
®
75
Fluid driven tank cleaner
TAnkJET
®75 FLuID DRIVEn TAnk CLEAnER
Specifications
Model No. 75-1858 75-1861
Flow rate
range: (42 to 102 lpm)11 to 27 gpm (30 to 125 lpm)8 to 33 gpm
Pressure
range: (5.2 to 20.7 bar)75 to 300 psi (3.5 to 20.7 bar)50 to 300 psi
RPM ranges: 10 to 18 RPM 7 to 17 RPM Max. operating temperature: 250°F (121°C) (121°C)250°F Min. tank opening size: (76.2 mm)3” (95.2 mm)3.75” Spray coverage: 360° 360° Inlet conn.: 3/4" nPT, BSPT (F) 3/4" nPT, BSPT (F)
Nozzles: Two: 0.234" (5.9 mm) or 0.172" (4.4 mm) orifice Four: 0.172" (4.4 mm) or 0.125" (3.2 mm) orifice
Weight: (0.9 kg)2 lbs (1.4 kg)3 lbs
thorough, cost-effective cleaning of tanks,
totes and iBcs up to 30’ (9.1 m) in dia.
Features and Benefits
• Ideal for medium impact cleaning and provides adequate
impingement cleaning of small tanks without the expense
of high impact tank cleaners
• Fluid driven with external gears to reduce speed of nozzles
for better impact and cleaning efficiency
• 360° indexing pattern is completed every 45 revolutions
• Solid stream nozzles rotate in multiple axes to provide
complete coverage of the entire tank
• Simple design is easy to maintain – can be rebuilt quickly
and easily in about 5 minutes
• Mount permanently or move from tank to tank
• Self-cleaning, flow-through design
• Long-wearing materials – 316 stainless steel, PTFE
and uHMWE-PE
Choose from two versions:
• TankJet 75-1858:
– Two nozzle hub design
– Two nozzle size options
– Fits in a 3” (76. 2 mm) opening
• TankJet 75-1861:
– Four nozzle design provides better coverage
and faster cleaning
– Two nozzle size options
– Fits in a 3.75” (95.2 mm) opening
Ideal for Cleaning:
• Chemical containers
• Dairy tanks and totes
• Food and beverage tanks
• Pharmaceutical tanks
• Process tanks
TankJet 75 tank
cleaners for tanks up
to 30’ (9.1 m) in dia.
Spray Coverage
360°
30'
(9.1 m)1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TAnkJET
®75 FLuID DRIVEn TAnk CLEAnER
Model no.
Capacity gpm (l/min)
50 psi
(3.4 bar) (5.2 bar)75 psi (6.9 bar)100 psi (10.3 bar)150 psi (13.8 bar)200 psi (17.2 bar)250 psi (21 bar)300 psi
TJ75-1858-234 – – – 20 (76) 23 (87) 25 (95) 27 (102) TJ75-1858-234LP – 13 (49) 15 (57) 18 (68) – – – TJ75-1858-172 – – – 15 (57) 18 (68) 20 (76) 22 (83) TJ75-1858-172LP – 11 (42) 13 (49) 15 (57) – – – TJ75-1861-172 – – – 23 (87) 29 (110) 31 (117) 33 (125) TJ75-1861-172LP 11 (42) 15 (57) 18 (68) 22 (83) – – – TJ75-1861-125 – – – 15 (57) 19 (72) 20 (76) 21 (80) TJ75-1861-125LP 8 (30) 11 (42) 12 (45) 15 (57) – – –
Performance Data
Ordering Information
tankJet 75 tank cleaning Machine
tJ75
__*
– 1858 –
234
lP
I I I I I
Model
No. TypeInlet Model Type Orifice SizeNozzle PressureLow * Add B for BSPT connections. If NPT connection, leave blank.
TankJet 75-1858
TankJet 75-1861
Dimensions
30'
(9.1 m) tank dia. Catalog 15 - TankJet 75 3.0” (76 mm) 3.75” (95 mm) 1.97” (50 mm) 1.97” (50 mm) 6.13” (156 mm) 6.13” (156 mm) 0211A
C
E
D
B
TankJet
®
27500 & 27500r
Fluid driven nozzleS
TAnkJET
®27500 & 27500R FLuID DRIVEn nOzzLES
Specifications
Max. tank dia.:
25’ (7.6 m)
Flow rate range:
4 to 391 gpm (15.3 to 1490 l/min)
Pressure range:
10 to 50 psi (.7 to 3.5 bar)
Max. operating
temperature:
200°F (93°C)
Min. tank
opening size:
2” to 7” (51 to 178 mm) depending on
capacity size
Spray coverage:
180° spraying up or down, 270°
spraying up or down and 360°
Inlet conn.
TankJet 27500:
1/2” to 3” nPT or BSPT (F)
Inlet conn.
TankJet 27500R:
1/2” to 1” nPT or BSPT (F)
PtFe rotating nozzles resist Harsh
chemicals and Provide excellent
cleaning and rinsing
Features and Benefits
• Especially suited for CIP systems – no motor source
is needed due to the reactionary force of the cleaning
liquid to rotate the spray head
• Provides more impact than static spray balls
• Long-life material of construction – corrosion- and
chemical-resistant PTFE fluoropolymer resin
• 27500R nozzles in 1/2” and 3/4” inlet connections are
available in carbon-filled PTFE for improved thermal
characteristics and higher mechanical strength over
standard PTFE
• Spray angles range from 180° to 360°; can clean certain
areas or entire tank interior
• 27500R has a rotating spray head that can be easily
removed from the body for inspection and maintenance
• To optimize performance of the rotating spray head,
use liquid free of debris
Ideal for Cleaning:
• Broke chests
• Chemical tanks
• PCB washers
• Pharmaceutical tanks
• Process tanks
Spray Coverage
180° Up 270° Up 360° 180° Down 270° DownTankJet 27500
tank cleaning nozzle
Some TankJet 27500R nozzles available in carbon-filled PTFE
TankJet 27500R
tank cleaning nozzles
for tanks up to 25’
(7.6 m) in dia.
25'
(7.6 m)1.800.95.SPRAY | Intl. 1.630.665.5000 | www.tankjet.com
TAnkJET
®27500 & 27500R FLuID DRIVEn nOzzLES
Nozzle No. Orifice Dia. (mm) Capacity gpm (l/min) Max. Tank Dia. (m) 10 psi
(0.7 bar) (1.5 bar)20 psi (2 bar)30 psi (3 bar)40 psi (3.5 bar)50 psi
l 27500 (A thru E)-R-1/2-8-TEF 3/32" (2.4) 4.0 (15.3) 5.7 (22) 6.9 (26) 8.0 (32) 8.9 (34) 10' (3.0) l 27500 (A thru E)-R-3/4-18-TEF 3/32" (2.4) 9.0 (34) 12.7 (50) 15.6 (58) 18 (71) 20 (77) 15' (4.3) 27500 (A thru E)-R-3/4-32-TEF 5/32" (4.0) 16 (61) 23 (89) 28 (103) 32 (126) 36 (136) 15' (4.3) 27500 (A thru E)-R-3/4-46-TEF 15/64" (6.0) 23 (88) 33 (130) 40 (148) 46 (182) 51 (196) 15' (4.3) 27500 (A thru E)-R-1-50-TEF 5/32" (4.0) 25 (95) 35 (140) 43 (161) 50 (197) 56 (215) 18' (5.5) 27500 (A thru E)-R-1-70-TEF 7/32" (5.6) 35 (133) 49 (195) 61 (225) 70 (275) 78 (300) 18' (5.5) 27500 (A thru E)-R-1-90-TEF 19/64" (7.5) 45 (172) 64 (250) 78 (290) 90 (355) 101 (385) 18' (5.5) 27500 (A thru E)-2-100-TEF 15/64" (6.0) 50 (191) 71 (280) 87 (320) 100 (395) 112 (425) 20' (6.0) 27500 (A thru E)-2-125-TEF 17/64" (6.7) 63 (240) 88 (350) 108 (400) 125 (495) 140 (530) 20' (6.0) 27500 (A thru E)-2-150-TEF 5/16" (7.9) 75 (285) 106 (420) 130 (480) 150 (590) 168 (640) 20' (6.0) 27500 (A thru E)-2-175-TEF 3/8" (9.5) 88 (335) 124 (490) 152 (560) 175 (690) 196 (745) 20' (6.0) 27500 (A thru E)-2-200-TEF 27/64" (10.7) 100 (380) 141 (560) 173 (645) 200 (790) 224 (850) 20' (6.0) 27500 (A thru E)-3-250-TEF 25/64" (9.9) 125 (475) 177 (700) 217 (805) 250 (985) 280 (1065) 25' (7.6) 27500 (A thru E)-3-300-TEF 27/64" (10.7) 150 (570) 212 (840) 260 (965) 300 (1180) 335 (1280) 25' (7.6) 27500 (A thru E)-3-350-TEF 31/64" (12.3) 175 (665) 247 (975) 303 (1130) 350 (1380) 391 (1490) 25' (7.6)
l Models available in carbon-filled PTFE.
Suggested optimum operating range: 20 to 40 psi (1.5 to 3 bar).
Performance Data
Nozzle Type Inlet Dia. X Dia. Y z Flats
27500, 27500R 1/2" 1-15/16" (49.2 mm) 2-3/8" (60.3 mm) 1-1/8" (28.6 mm)
27500, 27500R 3/4" 2-1/4" (57.2 mm) 2-5/8" (66.6 mm) 1-5/16" (33.3 mm)
27500, 27500R 1" 2-3/4" (69.8 mm) 3" (76.2 mm) 1-5/8" (45.3 mm)
27500 2" 4-7/8" (123.8 mm) 4-3/8" (111 mm) 2-3/4" (69.8 mm) 27500 3" 6-7/8" (174.6 mm) 5-7/8" (149.2 mm) 3-7/8" (98.4 mm)
tankJet 27500 tank cleaning nozzle
27500
e
–
r
– 3/4 – 18 – teF*
I I I I I I
Nozzle
Type CoverageType RemovableSpray
Head
Inlet
Conn. CapacitySize MaterialCode
*Indicate CTEF for carbon-filled PTFE.
Ordering Information
Dimensions
X Dia. Y Z25'
(7.6 m) tank dia. Catalog 15 - 27500 0211TankJet
®
14 and 16
Fluid driven Tank Cleaners
TankJeT
®14 and 16 Fluid driven Tank Cleaners
rotating units Provide Better Cleaning
than static spray Balls
Features and Benefits
• Similar design and appearance to static spray balls except
the units rotate to ensure effective impingement of cleaning
solution on tank walls
• Fluid driven, turbine driven units rotate at slow speeds –
3 to 15 rpm – for increased dwell time on tank surface
compared to free spinning units
• Solid stream pattern provides full coverage
• Suitable for CIP or portable installation
• Spray head is easily removed for inspection
and maintenance
• Made of 316 stainless steel and PTFE materials
Choose from two versions:
TankJet 14:
• Fits easily into a 2” Schedule 40 pipe
• For tanks up to 12’ (3.6 m) diameter
TankJet 16:
• Fits easily into a 3” Schedule 40 pipe
• For tanks up to 24’ (7.2 m) diameter
Ideal for Cleaning:
• Brewery tanks
• Pharmaceutical tanks
• Chemical mixers/blenders
• Totes/IBCs
• Food processing tanks
• Wine tanks
24'
(7.2 m)Tank dia.
Specifications
Model No. TJ14 TJ16