AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

AF SERIES

> Vasta gamma di lenti collimatrici

> Wide range of collimator lenses

> Grado di protezione IP67

> IP67 protection degree

> Collegabile alle unità SSF – FS1 – FX3 – FX4

> SSF – FS1 – FX3 – FX4 series connectable

> Approvazioni: CE

> Approvals: CE

Caratteristiche principali

Main features

Fibre ottiche componibili serie AF

Modular fibres for any application

AF series

Modello Tipo Tipo di accessorio SSF FS1 FX3 FX4 ø nucleo fibra ottica Modello fibra Terminazione Lente

Model Type Accessory type (EX.G.=1) (EX.G.=1) (EX.G.=1) (EX.G.=1) optical fibre core Fibre model Head shape Lenses

AF/C - Cutter - - - - 1 - -

-Fibra a metratura

AF/1S - Fibre to sell - - - - 1 - -

-by metres AF/ER4 P/R Lente collimatrice

Collimator lenses 600 mm 600 mm 2000 mm 3000 mm 1 AF/1S - Si/ Yes

AF/ER5 P/R Lente collimatrice

Collimator lenses 1000 mm 1000 mm 3000 mm 5000 mm 1 AF/1S - Si/ Yes

AF/ER6 P/R Lente collimatrice

Collimator lenses 3500 mm 3500 mm 6000 mm 8000 mm 1 AF/1S - Si / Yes

AF/ER7 P/R Lente collimatrice

Collimator lenses 1000 mm 1000 mm 6000 mm 8000 mm 1 AF/1S - Si/ Yes

(2)

Caratteristiche principali

Main features

Taglierino modello AF/C

Cutter model AF/C

Ø fibra ottica/ Optical fibre core 1 mm (plastico/ plastic)

Dimensioni

- Dimensions

17,5 46 25 8 2,2 2,2 2,2 3 3 7,5

NOTE: Tagliare l’estremità della fibra ottica col taglierino in dotazione prima di inserirla nella termi-nazione; la precisione del taglio è fondamentale per ottenere prestazioni ottimali.

NOTE: Before inserting the optical fibre into the fibre-head, cut it using the supplied cutter. In order to obtain the best perforances the accuracy of fibre-cutting is fundamental.

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

(3)

c

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

AF/1S SERIES

Caratteristiche principali

Main features

Fibra ottica modello AF/1S

Optical fibre AF/1S model

ø Fibra ottica/Optical fibre core 1 mm (plastico/ plastic)

Fibra ottica/Optical fibre Singola – fornita in metratura/ Single – sold by the metre

Dimensioni

- Dimensions

(4)

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

SERIE AF/ER4

Caratteristiche principali

Main features

Lenti collimatrici modello

AF/ER4

Collimator lenses AF/ER4

model

Codice fibra ottica/ Optical fibre code AF/1S

ø Fibra ottica/ Optical fibre core 1 mm (plastico/ plastic)

Distranza (con SSF)/ Distance (with SSF) 600 mm

Distranza (con FS1) /Distance (with FS1) 600 mm

Distranza (con FX3)/Distance (with FX3) 2000 mm

Distranza (con FX4)/ Distance (with FX4) 3000 mm

Materiale/ Materials Vetro, ETM, ottone nichelato/ Glass, ETM, nickel plated brass

Limiti di temperatura/Temperature range -40°C….+70°C

Grado di protezione / Protection degree IP67 (EN60529)

Dimensioni

- Dimensions

Ø5 AF / ER4 Ø3 9 7,5 6,5 18,5 Lente

Fibra ottica plastica core 1 mm M4x0.7

(5)

Caratteristiche principali

Main features

Lenti collimatrici modello

AF/ER5

Collimator lenses AF/ER5

model

Codice fibra ottica / Optical fibre code AF/1S

ø Fibra ottica / Optical fibre core 1 mm (plastico/ plastic)

Distranza (con SSF)/ Distance (with SSF) 1000 mm

Distranza (con FS1)/ Distance (with FS1) 1000 mm

Distranza (con FX3)/ Distance (with FX3) 3000 mm

Distranza (con FX4) / Distance (with FX4) 5000 mm

Materiale / Materials Vetro, ETM, ottone nichelato / Glass, ETM, nickel plated brass

Limiti di temperatura/ Temperature range -40°C….+70°C

Grado di protezione / Protection degree IP67 (EN60529)

Dimensioni

- Dimensions

Ø6

10 7,5 5,5

24 Lente

Fibra ottica plastica core 1 mm M4x0.7 distanza 3,5 Ø4 5 M6

c

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

(6)

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

SERIE AF/ER6

Caratteristiche principali

Main features

Lenti collimatrici modello

AF/ER6

Collimator lenses AF/ER6

model

Codice fibra ottica/ Optical fibre code AF/1S

ø Fibra ottica/ Optical fibre core 1 mm (plastico/ plastic)

Distranza (con SSF) /Distance (with SSF) 3500 mm

Distranza (con FS1)/ Distance (with FS1) 3500 mm

Distranza (con FX3)/ Distance (with FX3) 6000 mm

Distranza (con FX4)/Distance (with FX4) 8000 mm

Materiale/ Materials Vetro, ETM, ottone nichelato/ Glass, ETM, nickel plated brass

Limiti di temperatura/ Temperature range -40°C….+70°C

Grado di protezione/ Protection degree IP67 (EN60529)

Dimensioni

- Dimensions

Ø8 35 M4x0.7 Fibra ottica plastica core 1 mm 6 Ø4 25 3 3,5 5,5 Ø9 Lente M12x1

(7)

Caratteristiche principali

Main features

Lenti collimatrici modello

AF/ER7

Collimator lenses AF/ER7

model

Dimensioni

- Dimensions

30 Lente

Fibra ottica plastica core 1 mm

M6 9 16 8 5 Ø8 5,5 Ø4

Codice fibra ottica/ Optical fibre code AF/1S

ø Fibra ottica/ Optical fibre core 1 mm (plastico/ plastic)

Distranza (con SSF)/ Distance (with SSF) 1000 mm

Distranza (con FS1)/ Distance (with FS1) 1000 mm

Distranza (con FX3)/ Distance (with FX3) 6000 mm

Distranza (con FX4)/ Distance (with FX4) 8000 mm

Materiale/ Materials Vetro, ETM, ottone nichelato/ Glass, ETM, nickel plated brass

Limiti di temperatura/ Temperature range -40°C….+70°C

Grado di protezione/ Protection degree IP67 (EN60529)

c

AF series - photoelectric sensors FOR OPTICAL FIBRES

SENSORI FOTOELETTRICI A FIBRA OTTICA - SERIE AF

References

Related documents

The aim is to replace local natural gas heating units, in total, 25 natural gas boilers providing the space heating of 5 establishments (4 institutions of higher

In vitro antigen specific immune function was evaluated with and without exogenous interleukin-2 (IL-2.) The longitudinal evaluation of antigen specific proliferation in

 jobs (i) according to maximum profit order and (ii) All jobs that can be finished before dead line

Circle/underline the point, major transitions, and words that reveal tone; pay close attention to the introduction and conclusion for the topic and the author's opinion (see

the advantages of having counsel to conduct his case who is "at home" in the court room, and perhaps even.. acquainted with the very panel of jurors before whom his case is to be

We used ELMv1-ECA to evaluate how ignoring these nutrient uptake processes could affect simulated nitrogen and phosphorus losses and, by extension, carbon dynamics.. NO 3 −

(A porphyry is an igneous rock containing conspicuous crystals, called phenocrysts, surrounded by a matrix of finer-grained minerals or glass or both.) In most rocks,

Mochras has the potential to provide a global template for Early Jurassic earth systems interaction, an interval of major tectonic change (e.g. supercontinent breakup and formation