SHOWER WATER HEATER
MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E
INSTALLATION INSTRUCTIONS
Please read carefully Read these instruction carefully before using the appliance and retain them for future reference. If the appliance is passed on the third party please hand these instructions to the new user.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
This water heater must be installed (water and electrical installation), commissioned
and serviced by approved service technicians in accordance with these instructions.
Fig 1
Fig 2
Shower head level must not be higher than the unit
A B
C D
105 mm
360 mm.
212 mm 100 mm 360 mm 280 mm
9 8
7
Functions
Mounting dimensions
Fig 3
Fig 4
min. 4,5 mm
max. 10 mm
10
11
The cable bushing must be used to provide protection against the penertration of water.
The unit must be earthed !
Fixing method
Electrical connection
1. Installation instructions for the qualitified installer
Fig 5 Fig 6 13
14
15 12
a - Heating Element b - Electronic control set (Phase Cut) c - ELSD Circuit d - Triac Set e - Auto Thermostat f - ELSD-Button Board g - ELSD Sensor Coil