Single Wood Stud Walls

• QuietRock on one side

• 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

• 5/8” Type X on the other

• QuietRock on both sides

• 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

• 5/8” Type X on the other

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

• 2 layers 5/8” Type X on the other

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 49 - - TL07-021 1/2” 4-5/8”

516** 46 - - TL07-113 1/2” 4-1/2”

525 51 UL, 1 hour U386, W317 TL07-019 5/8” 4-3/4”

528 50 UL, 1 hour U386, W317 TL07-017 5/8” 4-3/4”

530 52 UL, 1 hour U309

1, U3761,

U386, W3131,

W317

B3414.5 5/8” 4-3/4”

545 THX 56 - - est. 1-3/8” 5-1/2”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 52 - - TL07-022 1/2” 4-1/2”

516** 49 - - TL07-112 1/2” 4-1/2”

525 55 - - TL07-020 5/8” 4-3/4”

528 54 UL, 1½ hour U385, W318 TL07-018 5/8” 4-3/4”

530 54 UL, 1 hour U3761, W3131 B3414.4 5/8” 4-3/4”

545 THX 60 - - B3433-4W 1-3/8” 6-1/4”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510* 47 UL, 1 hour U3091 TL06-133 1/2” 5”

516** 45 1 hour - est. 1/2” 5”

525 49 UL, 1 hour U386, W317 B3440.1 5/8” 5-3/8”

528 50 UL, 1 hour U386, W317 est. 5/8” 5-3/8”

530 53 UL, 1 hour U309

1, U3761, U386, W3131, W317 B3414.6 5/8” 5-3/8” 545 THX 58 1 hour - est. 1-3/8” 6-1/8” STC Fire UL/ULC Design # STC Report # Panel thickness Assembly Thickness

510* 49 UL, 1 hour U3091 est. 1/2” 5-1/2”

516** 47 1 hour - est. 1/2” 5-1/2”

525 52 UL, 1 hour U386, W317 est. 5/8” 6”

528 52 UL, 1 hour U386, W317 est. 5/8” 6”

530 55 UL, 1 hour

U3091, U3761,

U386, W3131,

W317 est. 5/8” 6”

(3)

Single Wood Stud Walls

• QuietRock over 5/8” Type X on both sides • 2x4 wood studs spaced 24” OC with 3-1/2“ batt insulation

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510* 53 UL, 1 hour U3091 est. 1/2” 5-1/2”

516** 50 1 hour - est. 1/2” 5-1/2”

525 57 1 hour - est. 5/8” 6”

528 57 UL, 1 hour U385, W318 est. 5/8” 6”

530 58 UL, 1 hour U309

1, U3761,

U386, W3131,

W317

est. 5/8” 6”

(4)

Staggered Wood Stud Walls

Two Hour Separation Wall

• QuietRock on one side

• 2x4 wood studs spaced 12” OC on 6” plates with 3-1/2“ minimum batt insulation • 5/8” Type X on the other

• QuietRock on both sides

• 2x4 wood studs spaced 12” OC on 6” plates with 3-1/2“ minimum batt insulation

• QuietRock over 5/8” Type X on one side • 2x4 wood studs spaced 12” OC on 6” plates with 3-1/2“ minimum batt insulation • 5/8” Type X on the other

• One layer of QuietRock on both outer walls • 1” fire-shield shaft liner material both sides

• Double 2x4 wood studs spaced 16” OC with 3-1/2” batt insulation on both sides

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 55 - - est. 1/2” 6-5/8”

525 57 UL, 1 hour U386, W317 est. 5/8” 6-3/4”

528 57 UL, 1 hour U386, W317 est. 5/8” 6-3/4”

530 58 UL, 1 hour U340

1, U3761,

U386, W3131,

W317

est. 5/8” 6-3/4”

545 THX 64 - - est. 1-3/8” 7-1/2”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 58 - - est. 1/2” 6-1/2”

525 61 - - B3440.4 5/8” 6-3/4”

528 61 UL, 1½ hour U385, W318 est. 5/8” 6-3/4”

530 62 UL, 1 hour U3401, U3761,

W3131 est. 5/8” 6-3/4”

545 THX 68 - - est. 1-3/8” 8-1/4”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 58 UL, 1 hour U3401 est. 1/2” 7-1/4”

525 60 UL, 1 hour U386, W317 est. 5/8” 7-3/8”

528 60 UL, 1 hour U386, W317 est. 5/8” 7-3/8”

530 61 UL, 1 hour U340

1, U3761,

U386, W3131,

W317

est. 5/8” 7-3/8”

545 THX 66 1 hour - est. 1-3/8” 8-1/8”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 69 UL, 2 hours U3471 TL07-119 1/2” 11-1/2”

(5)

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 62 - - est. 1/2” 9”

516** 62 - - est. 1/2” 9”

525 63 UL, 1 hour U386, W317 est. 5/8” 9-1/4”

528 63 UL, 1 hour U386, W317 est. 5/8” 9-1/4”

530 64 UL, 1 hour

U3411, U3761,

U386, W3131,

W317 est. 5/8” 9-1/4”

545 THX 71 - - est. 1-3/8” 10”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 63 - - est. 1/2” 9”

516** 64 - - est. 1/2” 9”

525 65 - - B3440.3 5/8” 9-1/4”

528 65 UL, 1½ hour U385, W318 est. 5/8” 9-1/4”

530 66 UL, 1 hour U341W3131, U3761 1, B3414-1 5/8” 9-1/4”

545 THX 75 - - B3433.1W 1-3/8” 10-3/4”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510* 69 UL, 1 hour U3411 est. 1/2” 10-3/8”

516** 70 1 hour - est. 1/2” 10-3/8”

525 71 UL, 1 hour U386, W317 est. 5/8” 10-1/2”

528 71 UL, 1 hour U386, W317 est. 5/8” 10-1/2”

530 72 UL, 1 hour U341

1, U3761, U386, W3131, W317 est. 5/8” 10-1/2” 545 THX 77 1 hour - est. 1-3/8” 11-1/4” STC Fire UL/ULC Design # STC Report # Panel thickness Assembly Thickness 510 71 - - est. 1/2” 10” 516** 72 - - est. 1/2” 10” 525 73 - - est. 5/8” 10-1/2”

528 73 UL, 1½ hour U385, W318 est. 5/8” 10-1/2”

530 74 UL, 1 hour U341W3131, U3761 1, B3414.2 5/8” 10-1/2”

545 THX 80 - - B3433-4W 1-3/8” 13-1/2”

Double Wood Stud Walls

• QuietRock on one side

• 2x4 wood studs spaced 24” OC, 1” min. air gap with 3-1/2“ batt insulation on both sides

• 5/8” Type X on the other

• QuietRock on both sides

• 2x4 wood studs spaced 24” OC, 1” min. air gap with 3-1/2“ batt insulation on both sides

• QuietRock on one side

• 2x4 wood studs spaced 24” OC, 1” min. air gap with 3-1/2“ batt insulation on both sides

• 2 layers 5/8” Type X on the other

• Double layer QuietRock on both sides

• 2x4 wood studs spaced 24” OC, 1” min. air gap with 3-1/2“ batt insulation on both sides

(6)

Single Steel Stud Walls

• QuietRock on one side

• 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

• 5/8” Type X on the other

• QuietRock on both sides

• 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

• 5/8” Type X over QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

• 5/8” Type X on the other

• 5/8” Type X over QuietRock on one side • 3-5/8” 25-ga. steel studs spaced 24” OC with 3-1/2“ batt insulation

• 2 layers 5/8” Type X on the other

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 53 - - est. 1/2” 4-5/8”

525 55 - - TL07-028 5/8” 4-7/8”

527 55 UL, 1 hour W460, V463, W459, V464 TL07-069 5/8” 4-7/8”

528 56 UL, 1 hour V463, W459 TL07-027 5/8” 4-7/8”

545 THX 62 - - est. 1-3/8” 5-5/8”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 55 - - est. 1/2” 4-5/8”

525 57 - - TL07-029 5/8” 4-7/8”

527 56 UL, 1 hour W460, V463, W459, V464 TL07-076 5/8” 4-7/8”

528 58 UL, 1 hour V463, W459 TL07-026 5/8” 4-7/8”

545 THX 66 - - est. 1-3/8” 6-3/8”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 54 UL, 1 hour U465, U473 TL07-030 1/2” 5-3/8”

525 59 1 hour - est. 5/8” 5-1/8”

527 59 UL, 1 hour W460, V463, W459, V464 est. 5/8” 5-1/8”

528 60 UL, 1 hour V463, W459 est. 5/8” 5-1/8”

545 THX 65 1 hour - est. 1-3/8” 6-1/4” STC Fire UL/ULC Design # STC Report # Panel thickness Assembly Thickness

510 56 UL, 1 hour U465, U473 TL07-031 1/2” 6”

525 62 1 hour - est. 5/8” 6-1/8”

527 62 UL, 1 hour W460, V463, W459, V464 est. 5/8” 6-1/8”

528 63 UL, 1 hour V463, W459 est. 5/8” 6-1/8”

(7)

• QuietRock on one side

• 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation

• 5/8” Type X on the other

• QuietRock on both sides

• 3-5/8” 25-ga. steel studs spaced 24” OC, 1” min air gap with 3-1/2“ batt insulation

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 62 - - est. 1/2” 9”

525 64 - - est. 5/8” 9-1/4”

527 64 UL, 1 hour W460, V463, W459, V464 TL07-392 5/8” 9-1/4”

528 65 UL, 1 hour V463, W459 est. 5/8” 9-1/4”

545 THX 70 - - est. 1-3/8” 10”

STC Fire Design #UL/ULC Report #STC thicknessPanel Assembly Thickness

510 63 - - est. 1/2” 9”

525 65 - - est. 5/8” 9-1/4”

527 65 UL, 1 hour W460, V463, W459, V464 TL07-391 5/8” 9-1/4”

528 66 UL, 1 hour V463, W459 est. 5/8” 9-1/4”

545 THX 75 - - est. 1-3/8” 10-3/4”

(8)

QuietWood soundproof wood panel offers easy and reliable noise reduction. QuietWood significantly reduces “high-heel footfall” noise and other

Floor/Ceiling Assemblies for Concrete Slab Construction

QuietHome Floor/Ceiling Assemblies for Wood Frame Construction (I-Joist)

Low-Noise Floor Assembly (Retrofit)

4

1 1/16” thick underlayment for concrete slab construction

QuietWood® interior panels are based on proven and patent-pending technology, which has a solid history of performance. Based on that demonstrated track record, Serious Materials backs the performance of QuietWood floor/ceiling panels with a one-year warranty against manufacturing defects.

2Structurally-rated subfloor

3Fire testing completed with 1.5” thick 2.0 pcf mineral wool insulation

4Field testing available upon request

*Ceiling panels attached to RC at 24” OC * Suspended gypsum ceiling ** IIC of 28 for 6” slab only

IIC ∆ IIC Report #

Tile floor over QuietPad 48 20 ** 08-018

Tile floor over QuietPad

plus ceiling* 63 - 08-012 Wood floor over QuietPad 54 26 ** 08-001

Wood floor over QuietPad

plus ceiling* 63 - 08-005

STC IIC Fire UL Design # Report # Wood* 63 59 UL, 1 hour L591 OL07-0603

Tile* 65 58 UL, 1 hour L591 OL07-0701

Carpet* 60 70 UL, 1 hour L591 OL07-0602

Carpet

References

Related documents

POSPac includes patent-pending technology called Applanix IN-Fusion™ and Applanix SmartBase™, which integrates Post-processed GNSS Virtual Reference Station (PPVRS) with

Astaro’s patent pending load balancing technology automatically makes use of all hardware resources in a cluster, whereas the master node takes the responsibility

Datakey Axis uses automated Single Sign-On (SSO) enabling technology (patent pending) and inte- grated smart card and USB token technology to provide the broadest application

JWLC (Juganu wireless lighting control module) Wireless Communication Lighting (wireless ready) by Juganu utilizes a proprietary, patent-pending, wireless communication

Our new hybrid technology combines a patented magnetic bearing, drag cup motor, force rebalance transducer (FRT), new patent- pending optical encoder dual-reader, and

Together, Wipro and Orchestral Networks provide patent pending technology using advanced software and virtualization that provides end- to-end management and coordination.. This

6 © Druvaa Software 2008 Druvaa SendUnique –Data De-duplication at Source Druvaa inSync uses patent pending data de-duplication technology called SendUnqiue to remove

Scientific grade camera with electronically variable shutter speed 1 inch sensor.. Pixel size: 7.4 x 7.4 microns Patent pending UVI-VIEW camera