Enhance your living environment with Mitsubishi Electric Ducted Air Conditioning Systems.

10 

Loading.... (view fulltext now)

Loading....

Loading....

Loading....

Loading....

Full text

(1)

Enhance your living environment with

Mitsubishi Electric Ducted

Air Conditioning Systems.

(2)

The Mitsubishi Electric Story.

Mitsubishi Electric have a proud history in the manufacturing and supply of leading edge electrical and electronic equipment for both domestic and commercial use. Our efforts to make indoor life

more comfortable began in 1921, with the introduction of our first electric fan which became an instant hit. Some 10 years later we began to manufacture coolers, which were just as popular.

Since then our understanding that technology is the driving factor of change in our lives has seen us

become a world leader in energy efficient air conditioning systems. However our development of breakthrough technologies and products is not just restricted to heating and cooling.

Since 1980 to the present day the pace at which Mitsubishi Electric has introduced and refined products that benefit society, industry and individuals, has been nothing less than astonishing.

These technologies include the world’s first large scale LED Screen for sports arenas, the world’s largest CRT television screen for the consumer market, the world’s first spiral escalator, the world’s fastest elevators, the antenna technology behind the world’s first in-flight internet service, solar cell technology and much more. Today Mitsubishi Electric is a global giant with operations in over 35 countries, with more than

97,000 employees.

Our commitment to quality service, research and development has helped us gain a leading position in today’s marketplace in a wide variety of areas including heating, cooling and air conditioning.

Mitsubishi Electric’s ‘today technology’ provides climate controlled comfort wherever you live, work and relax. Whether it’s consistent heating and cooling for the home or office, Mitsubishi Electric offers you

state-of-the-art technology that is quiet, simple to use, reliable and above all, energy efficient.

Our commitment to quality, service, research

and development has helped us gain a leading

position in today’s marketplace.

(3)

Indoor Fan Coil Unit

Delivers the conditioned air to the ductwork.

Outdoor Unit

Quietly delivers refrigerant to the indoor unit.

Air Diffuser

Diffusers are available in many designs to suit the decor of your home.

System Controller

Located conveniently within the home generally near the return air grille.

Ductwork

Delivers the conditioned air throughout the rooms of your home.

Return Air Grille and Filter

Filters the air as it returns it back to the indoor unit.

Round Diffuser Linear Diffuser

4 Way Diffuser

To enhance your living environment

has to be the ultimate in comfort.

With Mitsubishi Electric Ducted Inverter Systems, climate control is at the touch of a button.

Warm even heat during Winter and clean cool air during Summer. Our Ducted Systems are ideal for multiple room applications and can incorporate zone selection if required.

The Outdoor Inverter Unit that provides the power, is positioned outside your home, while the Indoor Fan Coil Unit is positioned out of sight in either the ceiling void, or under the floor. Cool or warm air is then ducted quietly into each room through visually appealing Air Diffusers positioned in the ceiling, wall or floor. Warm or cool air is then filtered and returned to the Indoor Fan Coil Unit through the Return Air Grille.

The system is easily operated via a wall mounted LCD Control Panel.

Mitsubishi Electric’s Ducted Inverter

Technology gives you the edge.

Mitsubishi Electric’s Advanced Technology Inverter Systems are more economical and efficient than conventional systems.

Conventional non-inverter systems run at a fixed speed. To maintain a set temperature the compressor switches on/off so room temperatures continually fluctuate, falling, rising and falling again.

To overcome this problem Mitsubishi Electric’s advanced inverter technology gently increases or decreases power to suit the prevailing conditions reaching the desired temperature quicker, more efficiently without severe temperature fluctuations. The resulting reduction in electricity consumption by our energy saving technology not only saves you money but also reduces your carbon footprint on the

environment.

Mitsubishi Electric’s Outdoor Inverter units have been aesthetically designed to minimise their visual impact on your environment.

Each contains a number of innovative features that makes them quieter, more energy efficient and reliable, placing them at the cutting edge in the industry.

Conventional air conditioner: Unstable temperature control

Inverter operation: Uniform temperature control

Set temperature Temperature fluctuation Compressor operation Compressor operation ON OFF ON OFF Too cold Too hot Time Time Uniform temperature control

(4)

Conditions of trial calculation ( according to Japan Refrigerant Association )

Place Operating time Operating period Set temperature

Office in Tokyo (Japan)

8AM to 8PM (12 hours/day) & 6 days/week Cooling: April 16–November 8 Heating: December 14–March 23

Before replacement: Installed 8 years ago Model name PLH-3GKHB/ PUH-3YKA After replacement: Power Inverter Model name PLA-RP71AA/ PUHZ-RP71VHA

70

%

reduction

Power Inverter Non-Inverter (R407C) COP Outdoor Unit 3.5 3.0 3HP 4HP 5HP 6HP 2.81 Average

33

% increase 17% UP 3.30 26% UP 3.21 26% UP 2.40 2.61 2.55 2.25 3.60 60% UP

Reducing Energy

Consumption.

Cost performance comparison

Inverter model vs. non-Inverter model:

Thanks to the new Inverter System, a large reduction in power consumption is now possible. This results in one of the highest COP* (Co-efficient of Performance) ratings in the industry, helping to lower overall running costs and provide greater savings.

Case Study 1– Power Consumption

Based on our calculations on the operating conditions shown below, the new Inverter

System can reduce power consumption by up to 70% compared to an old model installed 8 years ago.

Case Study 2 – COP*

Comparison of COP between non-Inverter and Power Inverter (4 way cassette type) models.

Quiet Operation

Improvements in the design of our fan blades combined with a new grille shape has seen us become No 1 in the industry.

The outdoor unit is even quieter when the outside temperatures drops, as it automatically switches to low noise mode which reduces it’s operating noise by a further 3dB.

DC Fan Motor

A highly efficient DC Motor drives the fan of the outdoor unit, offering up to 60% greater efficiency than the equivalent AC Motor.

Peace of Mind

All Mitsubishi Electric air conditioners used in residential applications are

covered by a full 5 year parts and labour warranty.

Mitsubishi Electric air conditioners have been designed and built to deliver optimum performance year in year out.

* COP is a performance and efficiency rating similar to the Star Energy Rating System. The higher the COP, the more efficient the system.

¬Noise level

Train interior

Quiet passenger car interior

(40km/h) Library interior rustling leavesSound of Human hearing limits (Extremely quiet) 10dB 40dB 60dB 80dB

The compact configuration provides larger airflow with low noise. OUTDOOR UNIT NOISE COMPARISON

*AT OUTDOOR TEMPERATURE OF 25ºC

DAY

50dB

(in cooling mode)

DAY

47dB

(in cooling mode)

Low-Noise mode

Suppressing to about 1/2 audible sound

(5)

Higher performance, lower power

consumption and longer life.

When it comes to comfort, efficiency and durability, Mitsubishi Electric has a distinct advantage over the opposition, we call it MEQ – Mitsubishi Electric Quality. Simply put it is a superior standard that we apply to our own business. While other systems may meet stringent industry standards, Mitsubishi Electric continually strives to exceed them. MEQ delivers air conditioning systems at the leading edge of technology that operate efficiently in extreme weather conditions, year in, year out.

MEQ Gives Us 3 Important Advantages:

Comfort

We have created products that are designed to provide you with exceptional comfort in your surroundings, in all weather conditions.

Efficiency

We strive for the perfect balance of performance, reliability, low power consumption

and a long operational life span for all our products. The result is an air conditioning range that is rated amongst the best in the industry in terms of design, quality and energy efficiency.

Durability

We subject the indoor and outdoor units of all our systems to rigorous durability testing, which includes harsher temperature extremes than are likely to be found anywhere in the world. This allows us to produce higher quality products that protect your investment through years of reliable service.

(6)

Compact Inverter.

The Advanced Technology in Mitsubishi Electric’s Compact Inverter makes it the perfect solution for today’s diversified Residential and Commercial requirements. For homes,

or small to medium size offices, our Compact Inverter Ducted System gives you cost effective climate control for both heating and cooling. Technological advances have increased output and efficiency, allowing you to reach and maintain your chosen temperature faster, without fluctuations, while using less energy. The Compact Inverter is

smaller and lighter, making handling and installation easier which gives you more flexibility in your choice of location.

Quiet Operation

The Compact Inverter operates at noise levels that are at the leading edge of Industry Standards.

Longer Maximum Piping Length

The new technology has also made it possible to pipe refrigerant up to 70 metres from the Inverter to the concealed Indoor Fan Coil Unit, giving you more choice and versatility in the layout of your Ducted System and positioning your Outdoor Unit.

Flexibility in Layout Planning is further enhanced by the integration of the Compact Inverter or Power Inverter outdoor units

and our range of Concealed Indoor Units.

Concealed Indoor Unit

Mitsubishi Electric’s range of Concealed Indoor Units are versatile and easy to install even where roof or under floor space is limited.

High Output Fan Capability

Even when the ductwork is very long, the volume of airflow remains consistent due to the high static pressure available from the fan coil unit’s multiple speed fan motor.

Computerised Dehumidification

This feature allows you to reduce the humidity inside your home keeping you comfortable in all seasons.

Power Inverter.

Ideal for larger homes or medium to large offices, the Mitsubishi Electric Power Inverter boasts all of the technological advances of the Compact Inverter with a number of design features that further reduce power consumption and make it ideally suited to commercial applications.

Ultra Quiet Operation

Improvements to the design of the dual fan blades and a new grille shape deliver operating noise levels that are the best in the industry. A Low Noise Priority function is also available, where the noise of the outdoor unit can be reduced via a switch or time clock.

Longer Maximum Piping Length

The Power Inverter can pipe refrigerant up to 75 metres to the concealed ceiling unit, further adding to it’s versatility and efficiency in getting airflow to where it is most effective.

Multi System Use

The Mitsubishi Electric Power Inverter can be connected to a number of concealed indoor units that can be centrally controlled by one remote controller.

100mm

from wall 500mm from unit

100mm

from wall 500mm from unit

Twin Triple Compact Inverter PUHZ-BP140VHA 2 x PEA-RP71 PUHZ-BP200VHA 2 x PEA-RP100EA-2 PUHZ-BP250VHA 2 x PEA-RP125 PUHZ-BP250VHA 3 x PEA-RP71 Power Inverter PUHZ-RP140VHA2 2 x PEA-RP71 PUHZ-RP140YHA2 2 x PEA-RP71 Model Size 71 100 125 140 200 250

Compact Inverter SUZ PUHZ-BP

Single Phase • • • •

Three Phase • •

Power Inverter PUHZ-RP

Single Phase • • • •

Three Phase • • •

Easier Installation Work Thanks to Compact and Light Weight Design

The newly developed scroll com-pressor is equipped with a “Frame Compliance Mechanism” that al-lows movement in the axial direc-tion of the frame supporting the cradle scroll. This greatly reduces both leaking and friction loss, en-suring very high efficiency through-out the speed range.

The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets and reluctance torque results in more efficient operation.

This produces the most efficient waveform in response to varying compressor motor rpm. By improving operat-ing efficiency from low to high speeds, annual electricity costs are reduced.

Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and out-door temperature, this technology is tailored to the char-acteristics of the new refrigerant to enhance operating efficiency.

A high-efficiency DC motor drives the fan of the outdoor unit. It offers up to 60% greater efficiency than an equivalent AC motor.

Our New Inverter features Energy Saving, Compact Design, Light Weight, and Basic Performances as well.

Advanced technology for High Efficiency

Numerous Leading-edge Technologies Assure High Efficiency

The inverter has been made com-pact by insert-moulding the cir-cuit pattern in synthetic resin. To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters.

S series outdoor unit can be connected not only with SLZ and SEZ but also some P series indoor units. Greater inverter line up satisfies your various requirement.

The silent operation of the outdoor unit Model BP100 has attained down to 50dB (cooling). Further 3dB can be reduced under the Silent Operation Mode.

Standard Inverter

Silent Outdoor Unit

Heating Operation Possible Even at 15°C Outside Temperature

Another possibility! Compact S series outdoor unit can now be connected to P series indoor unit as well.

A Product Line of 19 Models in 5 Types Responds to Your Versatile Needs.

To meet your interior or space designing, optimum indoor units can be selected from 5 types. A combination with different type indoor units in two or three rooms besides 1:1 combination can be constituted various applications.

The outdoor unit model BP100 counts for 943mm only for the height and 66kg for the mass. A significant weight reduction of 55kg has been attained compared to the Power Inverter. The burdening of installation/transporta-tion work can be lightened by the compact design and light weight. BP200/250 became compact as well!!

3dB reduction

50

dB

47

dB

Suppressing to about 1/2 audible sound

(compared to daytime)

Piping Length for Easier Installation

Refrigerant piping can be extended up to 50m or 70m by charging refrigerant additionally.

NEW SUZ-KA25 SUZ-KA35 SUZ-KA50 SUZ-KA60 SUZ-KA71 5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW

*50/60/71 models are for Twin/Triple use.

R22

Fixed Speed New Inverter 66kg

Power Inverter121kg New Inverter

131kg

Top flow198kg Side flow BP100

BP125/140 BP200/250 20m 20m 30m 50m 50m 70m 94kg 66kg 2007_SLIM_Aus 07.8.8 1:44 PM ページ 7

Concealed Indoor Unit

PEA - RP100EA2 PEA - RP125EA

Max Height Difference Max Piping Length Compact Inverter SUZ-KA71 15 30 PUHZ-BP100,125,140VHA 30 50 PUHZ-BP200/250VHA 30 70 Power Inverter PUHZ-RP71VHA2 30 50 PUHZ-RP100,125,140VHA2 30 75 PUHZ-RP100,125,140YHA2 30 75

( )

( )

( )

Suppressing to about 1/2 audible sound

(7)

Guaranteed

Operating

Range

SUZ-KA 10°C 24°C 15°C 15°C 24°C 10°C 21°C 20°C 25/35 50/60/71 all 46°C 43°C 46°C PUHZ-RP/BP 5°C ( 15°C )1 2 With the optional air outlet guide, the operation at 15°C outdoor temperature is possible.

Complies with AS/NZS 3823.2:2005 Clause 3.4 (Amdt1). 1

3

11°C for PUHZ-RP71. 2

Compact Inverter – Outdoor units

Capacity Rated kW Capacity (min-max) kW

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51 Airflow (Lo-Hi) L/S

Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Outdoor unit Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Indoor unit Power supply SUZ-KA71VA Single phase, 50Hz, 220-240V Indoor unit Outdoor unit Function PUHZ-BP200YHA PUHZ-BP100VHA PUHZ-BP250YHA 1067-1333 125 367-450 450-567 567-700 52-55 54-58 53-55 428 785 690 428 1,055 690 428 1,255 690 Power supply 818 Single phase, 50Hz, 220-240V 55 80 PUHZ-BP200YHA PUHZ-BP250YHA External finish

Outdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1 1000 53 1.3 20 50 47 54 70 66 7 30 68 943 950 330+30 18.24/15.64 20 53 850 840 330 52 49 55 72 Indoor unit 80 15.26/11.68 54-58 51-55 50 125 Discharge thermo, HP switch

32 25 2 3.4 Function Indoor unit PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2 External finish Power supply Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V PUHZ-RP71VHA2 PUHZ-RP100V/YHA2 Single phase, 50Hz, 220-240V 367-450 450-567 567-700 800-1000 920 1000 1170 1.6 1.9 2.4 3.9 44 47 49 51 47 50 52 54 66 70 72 74 48 54 55 56 Power supply 75 121 116 116 50 75

Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:16 8.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20 1350 950 330+30 V: 19.65/19.92 Y:6.37/6.46 30 30 1,255 1,415 428 428 428 428 52-55 690 690 690 690 785 1,055 46 59 72 76 465 1,600 614 46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 2.31 3.22 2.34 3.39 2.53 3.01 2.53 3.01 2.49 3.21

1170 54 51 56 84 74 19.46/15.38 40 3.9 PUHZ-BP125VHA PUHZ-BP140VHA 5.5 133 1.0/12.0 1 PUHZ-BP170YHA 126 9.47/9.88 4.7 Three phase, 50Hz, 380-415V 59 56 2167 330+30 Shell thermo, HP switch

70 59 77 30 1350 950 32 PEA-RP125EA PUHZ-BP125VHA PEA-RP140EA2 PUHZ-BP140VHA (0.9-10.2) (0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5) PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA 51-55 76 428 1,415 690 800-1000 Three phase, 50Hz, 380-415V 800-1000 150 47-51 74 465 1,600 614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EA PEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 Capacity Rated (min-max)Ÿ 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0)

Ÿ Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25 Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 4.07 5.39 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50 PUHZ-BP170YHA

Capacity Rated kW Capacity (min-max) kW

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51 Airflow (Lo-Hi) L/S

Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Outdoor unit Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Indoor unit Power supply SUZ-KA71VA Single phase, 50Hz, 220-240V Indoor unit Outdoor unit Function PUHZ-BP200YHA PUHZ-BP100VHA PUHZ-BP250YHA 1067-1333 125 367-450 450-567 567-700 52-55 54-58 53-55 428 785 690 428 1,055 690 428 1,255 690 Power supply 818 Single phase, 50Hz, 220-240V 55 80 PUHZ-BP200YHA PUHZ-BP250YHA External finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA Munsell 3Y 7.8/1.1

1000 53 1.3 20 50 47 54 70 66 7 30 68 943 950 330+30 18.24/15.64 20 53 850 840 330 52 49 55 72 Indoor unit 80 15.26/11.68 54-58 51-55 50 125 Discharge thermo, HP switch

32 25 2 3.4 Function Indoor unit PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2 External finish Power supply Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415V PUHZ-RP71VHA2 PUHZ-RP100V/YHA2 Single phase, 50Hz, 220-240V 367-450 450-567 567-700 800-1000 920 1000 1170 1.6 1.9 2.4 3.9 44 47 49 51 47 50 52 54 66 70 72 74 48 54 55 56 Power supply 75 121 116 116 50 75

Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:16 8.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20 1350 950 330+30 V: 19.65/19.92 Y:6.37/6.46 30 30 1,255 1,415 428 428 428 428 52-55 690 690 690 690 785 1,055 46 59 72 76 465 1,600 614 46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 2.31 3.22 2.34 3.39 2.53 3.01 2.53 3.01 2.49 3.21

1170 54 51 56 84 74 19.46/15.38 40 3.9 PUHZ-BP125VHA PUHZ-BP140VHA 5.5 133 1.0/12.0 1 PUHZ-BP170YHA 126 9.47/9.88 4.7 Three phase, 50Hz, 380-415V 59 56 2167 330+30 Shell thermo, HP switch70

59 77 30 1350 950 32 PEA-RP125EA PUHZ-BP125VHA PEA-RP140EA2 PUHZ-BP140VHA (0.9-10.2) (0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5) PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA 51-55 76 428 1,415 690 800-1000 800-1000Three phase, 50Hz, 380-415V 150 47-51 74 465 1,600 614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EA PEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 Capacity Rated (min-max)Ÿ 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0)

Ÿ Capacities stated are based on indoor unit connected to PUHZ-RP series outdoor units

25 Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 4.07 5.39 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50 PUHZ-BP170YHA

Power Inverter – Indoor units

Power Inverter – Outdoor units

Capacity Rated kW Capacity (min-max) kW

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm)

Depth (mm)

Weight kg

Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Outdoor unit Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm)

Depth (mm)

Weight kg

Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Indoor unit Power supply SUZ-KA71VA Single phase, 50Hz, 220-240V Indoor unit Outdoor unit Function PUHZ-BP200YHA PUHZ-BP100VHA PUHZ-BP250YHA 1067-1333 125 367-450 450-567 567-700 52-55 54-58 53-55 428 785 690 428 1,055 690 428 1,255 690 Power supply 818 Single phase, 50Hz, 220-240V 55 80 PUHZ-BP200YHA PUHZ-BP250YHA External finishOutdoor unit SUZ-KA71V A PUHZ-BP100VHA Munsell 3Y 7.8/1.1

1000 53 1.3 20 50 47 54 70 66 7 30 68 943 950 330+30 18.24/15.64 20 53 850 840 330 52 49 55 72 Indoor unit 80 15.26/11.68 54-58 51-55 50 125

Discharge thermo, HP switch 32 25 2 3.4 Function Indoor unit PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2 External finish

Power supply V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415VMunsell 3.0Y 7.8/1.1 PUHZ-RP71VHA2 PUHZ-RP100V/YHA2 Single phase, 50Hz, 220-240V 367-450 450-567 567-700 800-1000 9201.6 10001.9 2.4 1170 3.9 44 47 49 51 47 50 52 54 66 70 72 74 48 54 55 56 Power supply 75 121 116 116 50 75

Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:16

8.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20 1350 950 330+30 V: 19.65/19.92 Y:6.37/6.46 30 30 1,255 1,415 428 428 428 428 52-55 690 690 690 690 785 1,055 46 59 72 76 465 1,600 614 46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 2.31 3.22 2.34 3.39 2.53 3.01 2.53 3.01 2.49 3.21

1170 54 51 56 84 74 19.46/15.38 40 3.9 PUHZ-BP125VHA PUHZ-BP140VHA 5.5 133 1.0/12.0 1 PUHZ-BP170YHA 126 9.47/9.88 4.7 Three phase, 50Hz, 380-415V 59 56 2167 330+30

Shell thermo, HP switch70 59 77 30 1350 950 32 PEA-RP125EA PUHZ-BP125VHA PEA-RP140EA2 PUHZ-BP140VHA (0.9-10.2) (0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5) PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

51-55 76 428 1,415 690 800-1000 800-1000Three phase, 50Hz, 380-415V 150 47-51 74 465 1,600 614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EA PEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 Capacity Rated (min-max)Ÿ 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0)

Ÿ Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25

Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 4.07 5.39 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50 PUHZ-BP170YHA

Concealed Indoor Units

Capacity Rated kW Capacity (min-max) kW

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW

Input kW 2.48 2.51 3.25 3.2 4.42 4.07 5.03 4.51 Airflow (Lo-Hi) L/S

Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Outdoor unit Compressor output kW Airflow L/S Cooling mode Sound pressure level (dB)

Silent mode Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) Weight kg Chargeless piping length m Max piping length m Protection device

Rated running current Amps Breaker size Amps

Indoor unit Power supply SUZ-KA71VA Single phase, 50Hz, 220-240V Indoor unit Outdoor unit Function PUHZ-BP200YHA PUHZ-BP100VHA PUHZ-BP250YHA 1067-1333 125 367-450 450-567 567-700 52-55 54-58 53-55 428 785 690 428 1,055 690 428 1,255 690 Power supply 818 Single phase, 50Hz, 220-240V 55 80 PUHZ-BP200YHA PUHZ-BP250YHA External finish

Outdoor unit SUZ-KA71V A PUHZ-BP100VHA

Munsell 3Y 7.8/1.1 1000 53 1.3 20 50 47 54 70 66 7 30 68 943 950 330+30 18.24/15.64 20 53 850 840 330 52 49 55 72 Indoor unit 80 15.26/11.68 54-58 51-55 50 125 Discharge thermo, HP switch

32 25 2 3.4 Function Indoor unit PUHZ-RP125V/YHA2 PUHZ-RP140V/YHA2 External finish

Power supply V: Single phase, 50Hz, 220-240v Y: Three phase, 50Hz, 380-415VMunsell 3.0Y 7.8/1.1 PUHZ-RP71VHA2 PUHZ-RP100V/YHA2 Single phase, 50Hz, 220-240V 367-450 450-567 567-700 800-1000 9201.6 10001.9 2.4 1170 3.9 44 47 49 51 47 50 52 54 66 70 72 74 48 54 55 56 Power supply 75 121 116 116 50 75

Discharge thermo, HP switch

25 V:32 Y:16 V:32 Y:16 V:40 Y:16 8.04/9.74 V: 12.53/12.39 Y:4.08/4.03 V: 15.53/15.98 Y:5.04/5.20 1350 950 330+30 V: 19.65/19.92 Y:6.37/6.46 30 30 1,255 1,415 428 428 428 428 52-55 690 690 690 690 785 1,055 46 59 72 76 465 1,600 614 46 59 72

EER Rated COP 2.34 3.08 2.41 3.31 2.31 3.22 2.34 3.39 2.53 3.01 2.53 3.01 2.49 3.21

1170 54 51 56 84 74 19.46/15.38 40 3.9 PUHZ-BP125VHA PUHZ-BP140VHA 5.5 133 1.0/12.0 1 PUHZ-BP170YHA 126 9.47/9.88 4.7 Three phase, 50Hz, 380-415V 59 56 2167 330+30 Shell thermo, HP switch70

59 77 30 1350 950 32 PEA-RP125EA PUHZ-BP125VHA PEA-RP140EA2 PUHZ-BP140VHA (0.9-10.2) (0.9-8.1) (3.5-10) (3.5-11.2) (5.2-12.5) (4.7-14) (5.2-15.2) (4.7-17.4) (9.0-21.0) (9.5-23.5) (9-22.4) (9.5-25) (11.2-28) (12.5-31.5) PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA

PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2

PEA-RP71EA PEA-RP170WGA PEA-RP200WGA PEA-RP250WGA 51-55 76 428 1,415 690 800-1000 800-1000Three phase, 50Hz, 380-415V 150 47-51 74 465 1,600 614

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating

943

6.9 8 9.2 9.5 11.2 12.5 13 14.8 17.0 20.0 19 22.4 22

PEA-RP71EA PEA-RP71EA

PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 PEA-RP100EA2 PEA-RP125EA PEA-RP140EA2 Capacity Rated (min-max)Ÿ 7.1(3.3-8.1) 8.4(3.5-10.2) 10(4.9-11.4) 11.2(4.5-14.0) 12.5(5.5-14.0) 14(5.0-16.0) 14(5.5-15.3) 16(5.0-18.0)

Ÿ Capacities stated are based

on indoor unit connected to PUHZ-RP series outdoor units

25 Input kW

EER Rated/Partload see*3 COP

2.9 2.49 3.82 3.02 4.65 4.07 5.39 4.48 7.3 7.18 7.3 7.18 8.53 7.58

EER Partload see*3 3.04 2.94 2.86 2.91 3.19 3.19 3.07

2.73 3.21 2.97 3.33 2.69/3.43 3.31 2.67/3.26 3.50 PUHZ-BP170YHA

(8)

Concealed Bulkhead.

Ideal for apartments or offices where ceiling access is not available for ducting, the ceiling concealed model compresses installation space to just 270 mm in height with the KA series and an even smaller 200mm when using the new KD series. The KD series offers a number of improvements on the KA series including higher static pressure (50Pa) that allows it to be ducted to a limited number of outlets and the choice of hard wired control panel (VA) or infra red remote control (VAL).

Whisper Quiet Operation

When operating at full capacity the Bulkhead Unit generates just 28dB of sound, so other than feeling the benefit of the even temperature that it delivers, you would hardly know that it is operating.

SEZ-KA35/50/60/71VA

¬Noise level Train interior

Quiet passenger car interior

(40km/h) Library interior rustling leavesSound of Human hearing limits (Extremely quiet) 10dB 40dB 60dB 80dB

SPECIFICA TIONS: BULKHEAD INVERTER TYPE

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min-max) kW 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4 Input kW 1.06 1.1 1.78 1.84 1.96 2.45 2.46 2.36

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) W eight kg

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min-max) kW 0.9 - 3.2 0.9 - 4.5 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4 Input kW 0.778 0.83 1.09 1.108 1.78 1.87 1.89 2.05 2.53 2.37

Airflow (Lo-Med-Hi) L/S Ext static pressure Pa Sound pressure level dB(A) (Low-Mid-High) Height (mm) Dimensions Width (mm) Depth (mm) W eight kg Compressor output kW Airflow L/S Sound pressure level Cooling mode

Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) W eight kg Chargeless piping length m Max piping length m Breaker size Amps

SUZ-KA61VA SUZ-KA71VA Function

Outdoor unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA

35 SEZ-KD25VA SEZ-KD35VA SEZ-KD50VA SEZ-KD60VA SEZ-KD71VA

33.5 270 1,100 700 Single phase, 50Hz, 220-240V 200-333 30-35 31-39 Picture 53 7 58 48 61 37 33 550 23 27 0.65 1.3 800 285 SUZ-KA35VA SUZ-KA50VA Munsell 3Y 7.8/1.1 568/534 Single phase, 50Hz, 220-240V 46 59 SEZ-KD60VA/VAL SEZ-KD71VA/VAL SUZ-KA61VA SUZ-KA71VA Single phase, 50Hz, 220-240V 30-34-37 200 1,100 700 5-15-35-50 551 46 0.55 818 47 0.85 53 Power supply External finish

Outdoor unit SUZ-KA25VA

SEZ-KA71VA Standard: 30, Max: 50

32-43 SEZ-KA35VA SEZ-KA50VA SEZ-KA60VA

167-217 200-283 SEZ-KA71VA SUZ-KA71VA SEZ-KA35VA SEZ-KA50VA SUZ-KA35VA SUZ-KA50VA SEZ-KA60VA SUZ-KA61VA Power supply Indoor unit Outdoor unit Function

SEZ-KD25VA/VAL SEZ-KD35VA/VAL SEZ-KD50VA/VAL Power supply 92-1 16-150 116-150-183 166-208-250 200-250-300 200-266-333 23-26-30 23-28-33 30-34-38 30-35-40 200 700 700 200 900 700 18 21 20 10 55 30 20 68 850 840 330 EER Rated COP

EER Rated COP

3.33 3.65 2.76 3.21 2.76 2.77 2.89 3.38

Indoor unit*1

Indoor unit

Indoor unit*1

3.12 3.47 3.06 3.43 2.72 3.07 2.81 3.25 2.77 3.29

Specification Chart Concealed Bulkhead

Specification Chart Outdoor Bulkhead Units

SPECIFICA TIONS: BULKHEAD INVERTER TYPE

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min-max) kW 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4 Input kW 1.06 1.1 1.78 1.84 1.96 2.45 2.46 2.36

Airflow (Lo-Hi) L/S Ext static pressure Pa Sound pressure level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) W eight kg

Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min-max) kW 0.9 - 3.2 0.9 - 4.5 1.0 - 3.9 0.9 - 5.0 1.1- 5.6 1.1 - 7.2 1.1 - 6.3 0.9 - 8.0 0.9 - 8.3 0.9 - 10.4 Input kW 0.778 0.83 1.09 1.108 1.78 1.87 1.89 2.05 2.53 2.37

Airflow (Lo-Med-Hi) L/S Ext static pressure Pa Sound pressure level dB(A) (Low-Mid-High) Height (mm) Dimensions Width (mm) Depth (mm) W eight kg Compressor output kW Airflow L/S Sound pressure level Cooling mode

Heating mode Sound power level dB(A)

Height (mm) Dimensions Width (mm) Depth (mm) W eight kg Chargeless piping length m Max piping length m Breaker size Amps

SUZ-KA61VA SUZ-KA71VA Function

Outdoor unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA

35 SEZ-KD25VA SEZ-KD35VA SEZ-KD50VA SEZ-KD60VA SEZ-KD71VA

33.5 270 1,100 700 Single phase, 50Hz, 220-240V 200-333 30-35 31-39 Picture 53 7 58 48 61 37 33 550 23 27 0.65 1.3 800 285 SUZ-KA35VA SUZ-KA50VA Munsell 3Y 7.8/1.1 568/534 Single phase, 50Hz, 220-240V 46 59 SEZ-KD60VA/VAL SEZ-KD71VA/VAL SUZ-KA61VA SUZ-KA71VA Single phase, 50Hz, 220-240V 30-34-37 200 1,100 700 5-15-35-50 551 46 0.55 818 47 0.85 53 Power supply External finish

Outdoor unit SUZ-KA25VA

SEZ-KA71VA Standard: 30, Max: 50

32-43 SEZ-KA35VA SEZ-KA50VA SEZ-KA60VA

167-217 200-283 SEZ-KA71VA SUZ-KA71VA SEZ-KA35VA SEZ-KA50VA SUZ-KA35VA SUZ-KA50VA SEZ-KA60VA SUZ-KA61VA Power supply Indoor unit Outdoor unit Function

SEZ-KD25VA/VAL SEZ-KD35VA/VAL SEZ-KD50VA/VAL Power supply 92-1 16-150 116-150-183 166-208-250 200-250-300 200-266-333 23-26-30 23-28-33 30-34-38 30-35-40 200 700 700 200 900 700 18 21 20 10 55 30 20 68 850 840 330 EER Rated COP

EER Rated COP

3.33 3.65 2.76 3.21 2.76 2.77 2.89 3.38

Indoor unit*1

Indoor unit

Indoor unit*1

3.12 3.47 3.06 3.43 2.72 3.07 2.81 3.25 2.77 3.29

SEZ-KD models available with wireless remote controller. Complies with AS/NZS 3823.2:2005 Clause 3.4 (Amdt1).

1 2

(9)

Our new state of the art Controller allows you to get the most out of your Mitsubishi Electric Ducted Air Conditioning System. To aid communication in today’s multicultural society,

the control can be switched to 8 different languages.

Easy To Read Display

The large type in the dot Liquid Crystal Display allows the status of your system to be viewed at a glance, day or night. While most remote controls can be confusing our control has been specifically designed to be more user friendly. The Slimline styling has been designed to fit unobtrusively with any décor. The only visible buttons are those most frequently used: On/Off and Temperature Up/Down.

Total Control At Your Fingertips

Simply open the front panel and total control of your comfort is there at the touch of a button. From temperature control to automatic stop/start on a daily or weekly basis, it’s all there at your fingertips.

Energy Saving Control

Limiting the set temperature range

Setting upper and lower temperature limits prevents the unit from excessive heating and cooling, thereby saving energy further and reducing your power bill.

Operation Lock

The operation of all buttons on the control can be locked with the exception of the On/Off button.

This stops little children or any unauthorised person changing temperatures or settings that may in turn waste valuable energy and increase running costs.

New Weekly Timer

The Weekly Timer allows you to programme the unit with up to 8 different automatic On/Off and Temperature changes per day, 7 days in advance, which means your home or office can be at the optimum temperature whenever required.

Versatility Is The Key To Comfort Control

To allow you climate control of your home or office a number of Control System options are available. Three of the most popular are: • Locating the System Control Unit in a central position,

typically near the return air grille.

• Multiple Control Units, either fixed or Infra red, positioned in different rooms, each of which can control your system.

• Multiple Systems controlled by their individual Control Units or via one Central System Control which can be operated locally or “dialled into” through the World Wide Web, allowing you control of your system from anywhere in the world.

Easy Maintenance Function

Your System Control can also give you a complete

diagnostic on the condition of your indoor and outdoor units at the touch of a button, which means you can be sure that your system is operating efficiently at all times. In turn if any future service work is required, fault diagnostic time is drastically reduced.

French Russian Chinese Japanese

English Spanish Italian German

Control technology

Renovating air conditioning communication by

advanced MA Remote Controller newly developed

The air conditioning operation can be switched off automatically thus prevent-ing waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.

The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.

The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day. Display can be switched over

for 8 kinds of language.

Busy

time frame Setting to higher temperature

Less busy time frame 4 PAR-20MAA Conventional MA remote controller PAC-YT34STA Schedule timer PAR-21MAA-G remote controller Acknowledging the operation and control status at a

glance. The large size display upgrades visual acknowl-edgement capability. The operation and control status can be understood promptly.

Dot liquid crystal display section

Economical & Space saving 26 25 24 23 22 0 10 12 14 16 18 20 22 24 Opening time

Lunch time Dinner time

Closing time Setting to lower temperature 1 2 3 5 6 7 (Hr.) *Result of cooperative study with Japan Facility Solution Co, Ltd.

Recommend to use in The lower temperatures cannot be selected.

Recommend to use in

* The “Simple timer” (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the “Auto off timer” by switching the function of the remote controller.

* The change of setting may be limited to the administrator who knows the method to release the locking. Recommend to use in

Setting to invalidate all buttons or the op-eration other than with ON/OFF button is available. This always assures operation under an ade-quate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischie-vous operation.

*Based on our internal calculation

Easy maintenance information

(only for Power Inverter Mr. SLIM)

Reduces maintenance work drastically.

Enables you to check operation data of the indoor and outdoor units by remote controller. Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.

(only for PUHZ-RP HA2)

The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function. With this function, the refrigerant leakage which may happen during a long period of use can be easily checked with a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind. *The filter operating time is the time elapsed since the filter was reset.

NEW

NEW

0..5]QJGK]?sq.5,6,6/822NK ɚĘȸ7

ON/OFF TEMP.

Conventional inspection work

New improved method

Easy maintenance information

Accumulated operating time (x10 hours) Number of ON/OFF times (x10 times) Operating current (A) Heat exchanger temperature (˚C) Discharge temperature (˚C) Outdoor temperature (˚C) Intake air temperature (˚C) Heat exchanger temperature (˚C) Filter operating time* (Hours) Outdoor unit

Compressor Indoor unit

1 2 3 4 5 6 7 8 9 *The filter operating time is the time elapsed since the filter was reset.

Discharge temperature 64˚C Indoor unit Outdoor unit

Measure the intake air temperature

Remove the service panel

Measure the discharge temperature

Measure the outdoor air temperature

Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.

* The setting of the refrigerant add-ress is required for outdoor unit.

Air conditioner can be started/ stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA (Example of 1 : 1 system) Signal receiver PAR-21MAA PAR-21MAA (Example of 1 : 1 system) (Example of 1 : 1 system) (Example of 1 : 1 system) PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally) Adapter for remote ON/OFF Adapter for remote ON/OFF Indoor CN51 PAR-SL97A-E PAR-SL97A-E (Example of 1 : 1 system) PAR-21MAA (Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc. Power supply unit

LOSSNAY operation cable

LOSSNAY Wired remote controller M-NET adapter PAC-SF80MA-E Indoor CN51 Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub"

remote controllers. * When you use wired and wireless remote controllers PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote Controller PAR-21MAA

Wired Remote Controller Kit for PKA PAR-21MAAT-E

Wireless Remote Controller PAR-SL97A-E

Wireless Remote Controller Kit for PCA PAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series, no optional parts are required.)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter: PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remote display panel Remote display panel Indoor CN32 PAR-21 MAA-G Remote control panel Remote control panel Wired remote controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems. Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.

Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer. Adapter for remote ON/OFF Adapter for remote ON/OFF PAR-SL97A-E (Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally) Indoor CN51 Remote control panel Remote control panel Wired remote controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer.

Operation/emergency signal can be received at a distant place (no-voltage signal).

Weekly timer:

ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) Simple timer:

ON/OFF can be set once each within 72 hr. in a unit of one hour. Auto-off timer:

Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals. *Simple timer and Auto off timer cannot be used at the same time. Mounting the adapter for M-NET

connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)

Remote ON/OFF adapter PAC-SE55RA-E

Connector cable for remote display PAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)

Remote operation adapter PAC-SF40RM

*Unable to use with wireless remote controller Remote display panel (to be purchased locally) MAC-397IF-E* MAC-397IF-E* MAC-397IF-E (Interface) MAC-821SC-E

(Centralized remote controller) Centralized remote controller can be

connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.

The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller.

Up to 8 indoor units can be switched ON/OFF with one remote controller.

Indoor unit

MAC-821SC-E

MAC-397IF-E Outdoor unit

System Controls (P Series) Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25 66 8.04/9.74 <cool/heat> (A) (A) (kg) (kW) h c ti w s P H , o m r e h t e g r a h c s i D h c ti w s P H , o m r e h t e g r a h c s i D V: 32 Y: 16 69 V: 12.53/12.39 Y: 4.08/4.03 V: 32 Y: 16 70 V: 15.53/15.98 Y: 5.04/5.20 V: 40 Y: 16 71 V: 19.65/19.92 Y: 6.37/6.46 Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. *These figures are only outdoor unit. L/S

Sound power level

Breaker size (A)

(kg) (kW) Munsell 3.0Y 7.8/1.1 Single phase, 50Hz, 230V 3 . 1 5 8 . 0 49 (818) 53 55 68 0.55 34 (568) / 32 (534) 46 46 59 0.65 33 (551) 47 48 61 850 840 330 550 800 285 8 5 3 5 37 33 7 0 3 0 2 20 10 Cooling Heating Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size <cool/heat> (A) (A) (kg) (kW) Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. 116 121 Munsell 3Y 7.8/1.1 V 5 1 4 -0 8 3 , z H 0 5 , e s a h p 3 V 0 4 2 -0 2 2 , z H 0 5 , e s a h p e l g n i S 0 5 3 1 3 4 9 0 5 9 0 5 9 0 3 + 0 3 3 0 3 + 0 3 3 4.7 59 56 59 77 5.5 130 (2167) 54 51 56 52 49 55 50 3 3 1 6 2 1 32 30 70 Shell thermo, HP switch

9.47/9.88 11.0/12.0 84 80 66 19.46/15.38 18.24/15.64 15.26/11.68 9 . 3 4 . 3 0 . 2 40 32 25 20 50

Discharge thermo, HP switch 47 54 74 72 70 70 (1170) 60 (1000) 2007_SLIM_Aus 07.8.8 1:46 PM ページ 21 Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.

* The setting of the refrigerant add-ress is required for outdoor unit.

Air conditioner can be started/ stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA (Example of 1 : 1 system) Signal receiver PAR-21MAA PAR-21MAA (Example of 1 : 1 system) (Example of 1 : 1 system) (Example of 1 : 1 system) PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally) Adapter for remote ON/OFF Adapter for remote ON/OFF Indoor CN51 PAR-SL97A-E PAR-SL97A-E (Example of 1 : 1 system) PAR-21MAA (Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc. Power supply unit

LOSSNAY operation cable

LOSSNAY Wired remote controller M-NET adapter PAC-SF80MA-E Indoor CN51 Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub"

remote controllers. * When you use wired and wireless remote controllers

PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote Controller PAR-21MAA

Wired Remote Controller Kit for PKA PAR-21MAAT-E

Wireless Remote Controller PAR-SL97A-E

Wireless Remote Controller Kit for PCA PAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series, no optional parts are required.)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter: PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remote display panel Remote display panel Indoor CN32 PAR-21 MAA-G Remote control panel Remote control panel Wired remote controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems. Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.

Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer. Adapter for remote ON/OFF Adapter for remote ON/OFF PAR-SL97A-E (Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally) Indoor CN51 Remote control panel Remote control panel Wired remote controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer.

Operation/emergency signal can be received at a distant place (no-voltage signal).

Weekly timer:

ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) Simple timer:

ON/OFF can be set once each within 72 hr. in a unit of one hour. Auto-off timer:

Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals.

*Simple timer and Auto off timer cannot be used at the same time.

Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)

Remote ON/OFF adapter PAC-SE55RA-E

Connector cable for remote display PAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)

Remote operation adapter PAC-SF40RM

*Unable to use with wireless remote controller

Remote display panel (to be purchased locally) MAC-397IF-E* MAC-397IF-E* MAC-397IF-E (Interface) MAC-821SC-E

(Centralized remote controller) Centralized remote controller can be

connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.

The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller.

Up to 8 indoor units can be switched ON/OFF with one remote controller.

Indoor unit MAC-821SC-E

MAC-397IF-E Outdoor unit

System Controls (P Series) Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25 66 8.04/9.74 <cool/heat> (A) (A) (kg) (kW) h c ti w s P H , o m r e h t e g r a h c s i D h c ti w s P H , o m r e h t e g r a h c s i D V: 32 Y: 16 69 V: 12.53/12.39 Y: 4.08/4.03 V: 32 Y: 16 70 V: 15.53/15.98 Y: 5.04/5.20 V: 40 Y: 16 71 V: 19.65/19.92 Y: 6.37/6.46 Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. *These figures are only outdoor unit. L/S

Sound power level

Breaker size (A)

(kg) (kW) Munsell 3.0Y 7.8/1.1 Single phase, 50Hz, 230V 3 . 1 5 8 . 0 49 (818) 53 55 68 0.55 34 (568) / 32 (534) 46 46 59 0.65 33 (551) 47 48 61 850 840 330 550 800 285 8 5 3 5 37 33 7 0 3 0 2 20 10 Cooling Heating Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size <cool/heat> (A) (A) (kg) (kW) Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. 116 121 Munsell 3Y 7.8/1.1 V 5 1 4 -0 8 3 , z H 0 5 , e s a h p 3 V 0 4 2 -0 2 2 , z H 0 5 , e s a h p e l g n i S 0 5 3 1 3 4 9 0 5 9 0 5 9 0 3 + 0 3 3 0 3 + 0 3 3 4.7 59 56 59 77 5.5 130 (2167) 54 51 56 52 49 55 50 3 3 1 6 2 1 32 30 70 Shell thermo, HP switch

9.47/9.88 11.0/12.0 84 80 66 19.46/15.38 18.24/15.64 15.26/11.68 9 . 3 4 . 3 0 . 2 40 32 25 20 50

Discharge thermo, HP switch 47 54 74 72 70 70 (1170) 60 (1000) 2007_SLIM_Aus 07.8.8 1:46 PM ページ 21 Standard System

With 2 remote controllers, control can be performed locally and remotely from 2 spots.

One remote controller can control plural air conditioners simultaneously under a same setting.

* The setting of the refrigerant add-ress is required for outdoor unit.

Air conditioner can be started/ stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

Operating status can be displayed at a distant place.

Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

LOSSNAY can be controlled with remote controller

PAR-21MAA (Example of 1 : 1 system) Signal receiver PAR-21MAA PAR-21MAA (Example of 1 : 1 system) (Example of 1 : 1 system) (Example of 1 : 1 system) PAR-21MAA

Relay box (to be purchased locally)

Relay box (to be purchased locally) Adapter for remote ON/OFF Adapter for remote ON/OFF Indoor CN51 PAR-SL97A-E PAR-SL97A-E (Example of 1 : 1 system) PAR-21MAA (Example of 1 : 1 system x 2)

(Connection with M-NET system)

Centralized remote controller G-50, etc. Power supply unit

LOSSNAY operation cable

LOSSNAY Wired remote controller M-NET adapter PAC-SF80MA-E Indoor CN51 Remote operation adapter

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub"

remote controllers. * When you use wired and wireless remote controllers PAR-SL97A-E

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

PAR-SL97A-E

(Example of 1 : 1 + Simultaneous Twin)

Wired Remote Controller PAR-21MAA

Wired Remote Controller Kit for PKA PAR-21MAAT-E

Wireless Remote Controller PAR-SL97A-E

Wireless Remote Controller Kit for PCA PAR-SL99B-E

MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series, no optional parts are required.)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally)

Standard functions of PAR-21MAA

M-NET adapter: PAC-SF80MA-E

SLIM-LOSSNAY connection cable

A

B

C

D

E

F

G

H

I

Remote display panel Remote display panel Indoor CN32 PAR-21 MAA-G Remote control panel Remote control panel Wired remote controller

Either wired type or wireless type remote controller can be used.

Up to 2 remote controllers can be connected to 1 group.

Both wired and wireless remote controllers can be used in combination.

One remote controller can control up to 16 refrigerant systems. Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.

Up to 2 remote controllers can be connected.

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer. Adapter for remote ON/OFF Adapter for remote ON/OFF PAR-SL97A-E (Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

Adapter for remote ON/OFF PAC-SE55RA-E

Relay box (to be purchased locally) Remote control panel (to be purchased locally) Indoor CN51 Remote control panel Remote control panel Wired remote controller

Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

Timer control is possible with an external timer.

Operation/emergency signal can be received at a distant place (no-voltage signal).

Weekly timer:

ON/OFF and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) Simple timer:

ON/OFF can be set once each within 72 hr. in a unit of one hour. Auto-off timer:

Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min. intervals.

*Simple timer and Auto off timer cannot be used at the same time.

Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

Allows centralized control by MELANS.

LOSSNAY can be connected to the indoor unit.

None

Remote display panel (to be purchased locally)

Remote ON/OFF adapter PAC-SE55RA-E

Connector cable for remote display PAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)

Remote operation adapter PAC-SF40RM

*Unable to use with wireless remote controller

Remote display panel (to be purchased locally) MAC-397IF-E* MAC-397IF-E* MAC-397IF-E (Interface) MAC-821SC-E

(Centralized remote controller) Centralized remote controller can be

connected to each indoor unit via interface.

Individual ON/OFF and switching OFF at a time is possible with centralized controller.

The ON/OFF status of each unit can be confirmed by the LED on the centralized remote controller. Up to 8 indoor units can be

switched ON/OFF with one remote controller.

Indoor unit

MAC-821SC-E

MAC-397IF-E Outdoor unit

System Controls (P Series)

Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

L/S

Sound power level

Breaker size 25 66 8.04/9.74 <cool/heat> (A) (A) (kg) (kW) h c ti w s P H , o m r e h t e g r a h c s i D h c ti w s P H , o m r e h t e g r a h c s i D V: 32 Y: 16 69 V: 12.53/12.39 Y: 4.08/4.03 V: 32 Y: 16 70 V: 15.53/15.98 Y: 5.04/5.20 V: 40 Y: 16 71 V: 19.65/19.92 Y: 6.37/6.46 Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. *These figures are only outdoor unit. L/S

Sound power level

Breaker size (A)

(kg) (kW) Munsell 3.0Y 7.8/1.1 Single phase, 50Hz, 230V 3 . 1 5 8 . 0 49 (818) 53 55 68 0.55 34 (568) / 32 (534) 46 46 59 0.65 33 (551) 47 48 61 850 840 330 550 800 285 8 5 3 5 37 33 7 0 3 0 2 20 10 Cooling Heating Airflow <cool/heat>

Specifications: Outdoor unit

Munsell 3.0Y 7.8/1.1

V: Single phase, 50Hz, 220-240V Y: 3 phase, 50Hz, 380-415V

L/S

Sound power level

Breaker size <cool/heat> (A) (A) (kg) (kW) Cooling mode Silent mode Heating mode

*These figures are only outdoor unit. 116 121 Munsell 3Y 7.8/1.1 V 5 1 4 -0 8 3 , z H 0 5 , e s a h p 3 V 0 4 2 -0 2 2 , z H 0 5 , e s a h p e l g n i S 0 5 3 1 3 4 9 0 5 9 0 5 9 0 3 + 0 3 3 0 3 + 0 3 3 4.7 59 56 59 77 5.5 130 (2167) 54 51 56 52 49 55 50 3 3 1 6 2 1 32 30 70

Shell thermo, HP switch

9.47/9.88 11.0/12.0 84 80 66 19.46/15.38 18.24/15.64 15.26/11.68 9 . 3 4 . 3 0 . 2 40 32 25 20 50

Discharge thermo, HP switch 47 54 74 72 70 70 (1170) 60 (1000)

2007_SLIM_Aus 07.8.8 1:46 PM ページ 21

Controlling your comfort is easy in

anyone’s language.

Control technology

Renovating air conditioning communication by

advanced MA Remote Controller newly developed

The air conditioning operation can be switched off automatically thus prevent-ing waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.

The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.

The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day. Display can be switched over

for 8 kinds of language.

Busy

time frame Setting to higher temperature Less busy time frame 4 PAR-20MAA Conventional MA remote controller PAC-YT34STA Schedule timer PAR-21MAA-G remote controller Acknowledging the operation and control status at a

glance. The large size display upgrades visual acknowl-edgement capability. The operation and control status can be understood promptly.

Dot liquid crystal display section

Economical & Space saving 26 25 24 23 22 0 10 12 14 16 18 20 22 24 Opening time

Lunch time Dinner time

Closing time Setting to lower temperature 1 2 3 5 6 7 (Hr.)

*Result of cooperative study with Japan Facility Solution Co, Ltd.

Recommend to use in

The lower temperatures cannot be selected.

Recommend to use in

* The “Simple timer” (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the “Auto off timer” by switching the function of the remote controller.

* The change of setting may be limited to the administrator who knows the method to release the locking.

Recommend to use in

Setting to invalidate all buttons or the op-eration other than with ON/OFF button is available. This always assures operation under an ade-quate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischie-vous operation.

*Based on our internal calculation

Easy maintenance information

(only for Power Inverter Mr. SLIM)

Reduces maintenance work drastically.

Enables you to check operation data of the indoor and outdoor units by remote controller.

Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.

(only for PUHZ-RP HA2)

The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function. With this function, the refrigerant leakage which may happen during a long period of use can be easily checked with a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind. *The filter operating time is the time elapsed since the filter was reset.

NEW

NEW

(10)

Publication effective August 2008. Specifications subject to change without notice. Printed in Australia.

Warm, even heat in winter and cool fresh

air in summer is only a phone call or

click away.

Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about how to enhance your living environment. Our Specialists are fully qualified to give you all the right advice on which Mitsubishi Electric Ducted Air Conditioning System is right for you.

To locate your nearest Mitsubishi Electric Specialist go to our website

www.mitsubishielectric.com.au

They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for one of their Consultants to come to your home.

All Mitsubishi Electric Compact and Power Inverter Systems are MEPS (Minimum Efficiency Performance Standard) Compliant, so you can be sure that they will give you the performance and efficiency that they were designed to deliver.

Head Office Tokyo BUilding 2-7-3 MaRUnoUcHi, cHiyoda-kU 100-8310, JaPan

Mitsubishi Electric Shizuoka Works acquired ISO9001 certification under Series 9000 of the International Standard Organisation (ISO) based on a review of Quality warranties for the production of air conditioning equipment. The plant also acquired environmental management system standard ISO 14001 certification.

New South Wales 348 Victoria Road Rydalmere NSW 2116 Phone 02 9684 7555 Fax 02 9898 1043 Victoria/Tasmania Suite 28

Omnico Business Park 270 Ferntree Gully Road Notting Hill VIC 3168 Phone 03 9535 7800 Fax 03 9535 7801

Queensland/Northern Territory Unit 12, 469 Nudgee Road Hendra QLD 4011

Phone 07 3623 2000 Fax 07 3630 1888 North QLD - Townsville Mitsubishi Electric Office Phone 07 4728 5223 Fax 07 4728 5102 Capricorn Air 13 Mackley Street Garbutt QLD 4814 Phone 07 4775 5222 Fax 07 4775 5305 South Australia 77 Port Road Hindmarsh SA 5007 Phone 08 8340 2000 Fax 08 8340 0555 Western australia Unit 5, 329 Collier Road Bassendean WA 6054 Phone 08 9377 3400 Fax 08 9377 3499

MITSUBISHI ELECTRIC AUSTRALIA PTY LTD.

www.mitsubishielectric.com.au (Incorporated in New South Wales)

ABN 58 001 215 792 M IN IM U M E FF

ICIENCY PERFORMANCE

ST AN DA R D C O M P LIANT

M

EPS

Figure

Updating...

References

Updating...

Related subjects :