PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for

Design Conditions WB (F) RH (%)

ROOM HEAT Ambient 75.00 20.00

ROOM SENSIBLE HEAT Room 63.00 50.00

Solar Gain - Glass Difference -

-Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF) = 0.30 Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF) = 0.70

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person 30.00 No = 6.00 = 180.00 Glass - W 164.00 SqFt x 40.00 F x 0.65 4,264.00 CFM Per SqFt 0.33 Sqft x 160.97 = 53.12 Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM) = 1.00

Skylight SqFt x F x 0.00 CFM Cu.ft 1,609.65 x 1.00 x1/60 = 26.83 Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window x cfm/window = 0.00 Wall - NE SqFt x F x 0.00 Revolving Doors (People) x cfm/door = 0.00 Wall - E SqFt x F x 0.00 Open Doors x cfm/door = 0.00 Wall - SE SqFt x F x 0.00 Crack (feet) x cfm/ft = 0.00

Wall - S SqFt x F x 0.00 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat = Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) = All Glass 40.00 SqFt x 35.00 F x 0.65 910.00 Selected ADP (F) = 53.50 Partition 300.80 SqFt x 30.00 F x 0.32 2,887.68

Ceiling 160.96 SqFt x 30.00 F x 0.16 772.61 (Room DB - ADP) x CF = 15.05 Floor 160.96 SqFt x 30.00 F x 0.16 772.61 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 76.00 CFM x 35.00 T.Diff x 1.08 2,872.80 Dehumidified Rise x 1.08 = 1,202.19 CFM Outside Air 180.00 CFM x 35.00 T.Diff x 0.3x 1.08 2,041.20

Internal Heat = 565.03 L/s

People 6.00 Nos. x 245.00 Btu/Hour Per Person 1,470.00 TOTAL HEAT CAPACITY Lighting 160.97 SqFt x 0.75 W/SqFt x 3.41 409.14 3.01

Equipments 160.97 SqFt x 2.48 W/SqFt x 3.41 1,363.94 Power 0.00 kW/Hpx 0.00 0.00

17,763.98 5-10% 1,776.40

19,540.38 1.00 SENSIBLE HEAT CAPACITY

ROOM LATENT HEAT Grand Sensible Heat = 2.33 TR

Infiltration 76.00 CFM x 9.00 Gr/Lb x 0.68 465.12 12,000.00 933.91 cfm Outside Air 180.00 CFM x 9.00 Gr/Lb x BFx0.68 330.48

People 6.00 Nos. x 205.00 Btu/Hour Per Person 1,230.00 2,025.60 2.5 - 5% 101.28

2,126.88 2.00

EFFECTIVE ROOM TOTAL HEAT 21,667.26 OUTSIDE AIR HEAT

Sensible 180.00 CFM x 35.00 F(TD) x CF x 1.08 4,762.80 3.00

Latent 180.00 CFM x 9.00 Gr/Lb x CF x 0.68 771.12 4.00

OUTSIDE AIR TOTAL HEAT 5,533.92 Notes:

GRAND SUB-TOTAL HEAT 27,201.18

1 - 3% 816.04 28,017.21 TONS=GRAND TOTAL HEAT/12000 2.33

G+5 BUILDING HEAT LOAD 1st floor Right side

Laxmi nagar , New delhi. HALL

XYZ 160.97

Item Area or Quantity

Sun Gain or Temp. Diff. Factor Btu/Hour

ABC 10.00 1,609.65 CFM Ventilation W Summer DB (F) SH Gr/Lb 110.00 75.00 75.00 66.00 35.00 9.00

GRAND TOTAL HEAT

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

Sub Total Factor

Effective Room Sensible Heat

Sub Total Factor Effective Room Latent Heat

Factor

TR = 3.01 CFM =1202.19

(2)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N 0.00 SqFt x 0.00 F x 0.00 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W SqFt x F x 0.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E SqFt x F x 0.00 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S SqFt x F x 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 0.00 SqFt x 35.00 F x 0.65 0.00 Selected ADP (F) Partition 147.40 SqFt x 30.00 F x 0.32 1,415.04

Ceiling 54.31 SqFt x 30.00 F x 0.16 260.69 (Room DB - ADP) x CF

Floor 54.31 SqFt x 30.00 F x 0.16 260.69 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 20.00 CFM x 35.00 T.Diff x 1.08 756.00 Dehumidified Rise x 1.08 Outside Air 180.00 CFM x 35.00 T.Diff x 0.3x 1.08 2,041.20

Internal Heat

People 6.00 Nos. x 245.00 Btu/Hour Per Person 1,470.00 TOTAL HEAT CAPACITY Lighting 54.32 SqFt x 2.20 W/SqFt x 3.41 407.47 1.37

Equipments 54.32 SqFt x 11.04 W/SqFt x 3.41 2,044.78

Power 0.00 kW/Hpx 0.00 0.00

8,655.86 5-10% 865.59

9,521.45

1.00

SENSIBLE HEAT CAPACITY XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

Item Area or Quantity

Sun Gain or Temp. Diff. Factor Btu/Hour

ABC

W

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

Sub Total Factor

(3)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 20.00 CFM x 9.00 Gr/Lb x 0.68 122.40 12,000.00

Outside Air 180.00 CFM x 9.00 Gr/Lb x BFx0.68 330.48 People 6.00 Nos. x 205.00 Btu/Hour Per Person 1,230.00

1,682.88 2.5 - 5% 84.14

1,767.02

2.00

EFFECTIVE ROOM TOTAL HEAT 11,288.48

OUTSIDE AIR HEAT

Sensible 180.00 CFM x 35.00 F(TD) x CF x 1.08 4,762.80

3.00

Latent 180.00 CFM x 9.00 Gr/Lb x CF x 0.68 771.12

4.00

OUTSIDE AIR TOTAL HEAT 5,533.92 Notes:

GRAND SUB-TOTAL HEAT 16,822.40

1 - 3% 504.67 17,327.07

TONS=GRAND TOTAL HEAT/12000 1.44

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(4)

7.41 7.33 Area 54.3153 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 6.00 = 180.00 0.33 Sqft x 54.32 = 17.92 Air Change Per Hour (CFM) = 1.00

543.15 x 1.00 x1/60 = 9.05 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 52.00

(Room DB - ADP) x CF = 16.10

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 547.59 CFM = 257.37 L/s TOTAL HEAT CAPACITY

SENSIBLE HEAT CAPACITY

54.32

1st floor Right side DIMENSION

DINING 10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 543.15 Summer DB (F) SH Gr/Lb 110.00 75.00 TR = 1.37 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

(5)

= 1.44 TR ACCEPT THIS TR 577.57 cfm ACCEPT THIS CFM

(6)
(7)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W 164.00 SqFt x 40.00 F x 0.65 4,264.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E SqFt x F x 0.00 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S 59.10 SqFt x 43.00 F x 0.48 1,219.82

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 40.00 SqFt x 35.00 F x 0.65 910.00 Selected ADP (F) Partition 101.60 SqFt x 30.00 F x 0.32 975.36

Ceiling 148.68 SqFt x 30.00 F x 0.16 713.66 (Room DB - ADP) x CF

Floor 148.68 SqFt x 30.00 F x 0.16 713.66 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 76.00 CFM x 35.00 T.Diff x 1.08 2,872.80 Dehumidified Rise x 1.08 Outside Air 60.00 CFM x 35.00 T.Diff x 0.3x 1.08 680.40

Internal Heat

People 2.00 Nos. x 245.00 Btu/Hour Per Person 490.00 TOTAL HEAT CAPACITY Lighting 148.68 SqFt x 0.40 W/SqFt x 3.41 204.57 2.48

Equipments 148.68 SqFt x 2.35 W/SqFt x 3.41 1,193.48

Power 0.00 kW/Hpx 0.00 0.00

14,237.76 5-10% 1,423.78

15,661.54

1.00

SENSIBLE HEAT CAPACITY XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

Item Area or Quantity

Sun Gain or Temp. Diff. Factor Btu/Hour

ABC

W

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

Sub Total Factor

(8)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 76.00 CFM x 9.00 Gr/Lb x 0.68 465.12 12,000.00

Outside Air 60.00 CFM x 9.00 Gr/Lb x BFx0.68 110.16 People 2.00 Nos. x 205.00 Btu/Hour Per Person 410.00 985.28 2.5 - 5% 49.26

1,034.54

2.00

EFFECTIVE ROOM TOTAL HEAT 16,696.08

OUTSIDE AIR HEAT

Sensible 60.00 CFM x 35.00 F(TD) x CF x 1.08 1,587.60

3.00

Latent 60.00 CFM x 9.00 Gr/Lb x CF x 0.68 257.04

4.00

OUTSIDE AIR TOTAL HEAT 1,844.64 Notes:

GRAND SUB-TOTAL HEAT 18,540.72

1 - 3% 556.22 19,096.94

TONS=GRAND TOTAL HEAT/12000 1.59

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(9)

10.5 14.16 Area 148.68 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 2.00 = 60.00 0.33 Sqft x 148.68 = 49.06 Air Change Per Hour (CFM) = 1.00

1,486.80 x 1.00 x1/60 = 24.78 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 54.15

(Room DB - ADP) x CF = 14.60

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 993.59 CFM = 466.99 L/s TOTAL HEAT CAPACITY

ACCEPT THIS TR

SENSIBLE HEAT CAPACITY

148.68

1st floor Right side DIMENSION

BEDROOM 10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 1,486.80 Summer DB (F) SH Gr/Lb 110.00 75.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

75.00 66.00

35.00 9.00

CFM =993.59 TR = 2.48

(10)

= 1.59 TR

(11)
(12)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E 40.00 SqFt x 12.00 F x 0.65 312.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W SqFt x F x 0.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E 101.60 SqFt x 29.00 F x 0.48 1,414.27 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S SqFt x F x 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 40.00 SqFt x 35.00 F x 0.65 910.00 Selected ADP (F) Partition 161.60 SqFt x 30.00 F x 0.32 1,551.36

Ceiling 172.19 SqFt x 30.00 F x 0.16 826.49 (Room DB - ADP) x CF

Floor 172.19 SqFt x 30.00 F x 0.16 826.49 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 56.00 CFM x 35.00 T.Diff x 1.08 2,116.80 Dehumidified Rise x 1.08 Outside Air 120.00 CFM x 35.00 T.Diff x 0.3x 1.08 1,360.80

Internal Heat

People 4.00 Nos. x 245.00 Btu/Hour Per Person 980.00 TOTAL HEAT CAPACITY Lighting 172.19 SqFt x 0.58 W/SqFt x 3.41 340.99 2.06

Equipments 172.19 SqFt x 2.61 W/SqFt x 3.41 1,534.41

Power 0.00 kW/Hpx 0.00 0.00

12,173.61 5-10% 1,217.36

13,390.97

1.00

SENSIBLE HEAT CAPACITY Sub Total

Factor

Effective Room Sensible Heat

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise W ABC Item Area or Quantity Sun Gain or Temp. Diff. Factor Btu/Hour

XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

(13)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 56.00 CFM x 9.00 Gr/Lb x 0.68 342.72 12,000.00

Outside Air 120.00 CFM x 9.00 Gr/Lb x BFx0.68 220.32 People 4.00 Nos. x 205.00 Btu/Hour Per Person 820.00 1,383.04 2.5 - 5% 69.15

1,452.19

2.00

EFFECTIVE ROOM TOTAL HEAT 14,843.16

OUTSIDE AIR HEAT

Sensible 120.00 CFM x 35.00 F(TD) x CF x 1.08 3,175.20

3.00

Latent 120.00 CFM x 9.00 Gr/Lb x CF x 0.68 514.08

4.00

OUTSIDE AIR TOTAL HEAT 3,689.28 Notes:

GRAND SUB-TOTAL HEAT 18,532.44

1 - 3% 555.97 19,088.42

TONS=GRAND TOTAL HEAT/12000 1.59

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(14)

12.16 14.16 Area 172.1856 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 4.00 = 120.00 0.33 Sqft x 172.19 = 56.82 Air Change Per Hour (CFM) = 1.00

1,721.86 x 1.00 x1/60 = 28.70 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 53.50

(Room DB - ADP) x CF = 15.05

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 823.86 CFM = 387.21 L/s TOTAL HEAT CAPACITY

ACCEPT THIS TR

SENSIBLE HEAT CAPACITY

CFM =823.86 TR = 2.06 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise Summer

DB (F) SH Gr/Lb

110.00 75.00

10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 1,721.86

172.19

1st floor Right side DIMENSION

(15)

= 1.59 TR

(16)
(17)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for

Design Conditions WB (F) RH (%)

ROOM HEAT Ambient 75.00 20.00

ROOM SENSIBLE HEAT Room 63.00 50.00

Solar Gain - Glass Difference -

-Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF) = 0.30 Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF) = 0.70

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person 30.00 No = 6.00 = 180.00 Glass - W 164.00 SqFt x 40.00 F x 0.65 4,264.00 CFM Per SqFt 0.33 Sqft x 160.97 = 53.12 Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM) = 1.00

Skylight SqFt x F x 0.00 CFM Cu.ft 1,609.65 x 1.00 x1/60 = 26.83 Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window x cfm/window = 0.00 Wall - NE SqFt x F x 0.00 Revolving Doors (People) x cfm/door = 0.00 Wall - E SqFt x F x 0.00 Open Doors x cfm/door = 0.00 Wall - SE SqFt x F x 0.00 Crack (feet) x cfm/ft = 0.00

Wall - S SqFt x F x 0.00 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat = Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) = All Glass 40.00 SqFt x 35.00 F x 0.65 910.00 Selected ADP (F) = 53.25 Partition 218.30 SqFt x 30.00 F x 0.32 2,095.68

Ceiling 160.97 SqFt x 30.00 F x 0.16 772.63 (Room DB - ADP) x CF = 15.23 Floor 160.97 SqFt x 30.00 F x 0.16 772.63 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 76.00 CFM x 35.00 T.Diff x 1.08 2,872.80 Dehumidified Rise x 1.08 = 1,135.39 CFM Outside Air 180.00 CFM x 35.00 T.Diff x 0.3x 1.08 2,041.20

Internal Heat = 533.63 L/s

People 6.00 Nos. x 245.00 Btu/Hour Per Person 1,470.00 TOTAL HEAT CAPACITY Lighting 160.97 SqFt x 0.75 W/SqFt x 3.41 409.14 2.84

Equipments 160.97 SqFt x 2.48 W/SqFt x 3.41 1,363.94 Power 0.00 kW/Hpx 0.00 0.00

16,972.03 5-10% 1,697.20

18,669.23 1.00 SENSIBLE HEAT CAPACITY

ROOM LATENT HEAT Grand Sensible Heat = 2.26 TR

Infiltration 76.00 CFM x 9.00 Gr/Lb x 0.68 465.12 12,000.00 904.00 cfm Outside Air 180.00 CFM x 9.00 Gr/Lb x BFx0.68 330.48

People 6.00 Nos. x 205.00 Btu/Hour Per Person 1,230.00 2,025.60 2.5 - 5% 101.28

2,126.88 2.00

EFFECTIVE ROOM TOTAL HEAT 20,796.11 OUTSIDE AIR HEAT

Sensible 180.00 CFM x 35.00 F(TD) x CF x 1.08 4,762.80 3.00

Latent 180.00 CFM x 9.00 Gr/Lb x CF x 0.68 771.12 4.00

OUTSIDE AIR TOTAL HEAT 5,533.92 Notes:

GRAND SUB-TOTAL HEAT 26,330.03

1 - 3% 789.90 27,119.93 TONS=GRAND TOTAL HEAT/12000 2.26

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

CFM =1135.39 Sub Total

Factor

Effective Room Sensible Heat

Sub Total Factor TR = 2.84 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise W Summer DB (F) SH Gr/Lb 110.00 75.00 ABC 10.00 1,609.65 Item Area or Quantity Sun Gain or Temp. Diff. Factor Btu/Hour

XYZ 160.97

G+5 BUILDING HEAT LOAD 1st floor Right side

(18)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N 0.00 SqFt x 0.00 F x 0.00 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W SqFt x F x 0.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E SqFt x F x 0.00 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S SqFt x F x 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 0.00 SqFt x 35.00 F x 0.65 0.00 Selected ADP (F) Partition 156.60 SqFt x 30.00 F x 0.32 1,503.36

Ceiling 61.20 SqFt x 30.00 F x 0.16 293.76 (Room DB - ADP) x CF

Floor 61.20 SqFt x 30.00 F x 0.16 293.76 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 20.00 CFM x 35.00 T.Diff x 1.08 756.00 Dehumidified Rise x 1.08 Outside Air 180.00 CFM x 35.00 T.Diff x 0.3x 1.08 2,041.20

Internal Heat

People 6.00 Nos. x 245.00 Btu/Hour Per Person 1,470.00 TOTAL HEAT CAPACITY Lighting 61.20 SqFt x 1.96 W/SqFt x 3.41 409.04 1.39

Equipments 61.20 SqFt x 9.80 W/SqFt x 3.41 2,046.00

Power 0.00 kW/Hpx 0.00 0.00

8,813.12 5-10% 881.31

9,694.43

1.00

SENSIBLE HEAT CAPACITY Sub Total

Factor

Effective Room Sensible Heat

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise W ABC Item Area or Quantity Sun Gain or Temp. Diff. Factor Btu/Hour

XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

(19)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 20.00 CFM x 9.00 Gr/Lb x 0.68 122.40 12,000.00

Outside Air 180.00 CFM x 9.00 Gr/Lb x BFx0.68 330.48 People 6.00 Nos. x 205.00 Btu/Hour Per Person 1,230.00

1,682.88 2.5 - 5% 84.14

1,767.02

2.00

EFFECTIVE ROOM TOTAL HEAT 11,461.45

OUTSIDE AIR HEAT

Sensible 180.00 CFM x 35.00 F(TD) x CF x 1.08 4,762.80

3.00

Latent 180.00 CFM x 9.00 Gr/Lb x CF x 0.68 771.12

4.00

OUTSIDE AIR TOTAL HEAT 5,533.92 Notes:

GRAND SUB-TOTAL HEAT 16,995.37

1 - 3% 509.86 17,505.23

TONS=GRAND TOTAL HEAT/12000 1.46

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(20)

7.5 8.16 Area 61.2 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 6.00 = 180.00 0.33 Sqft x 61.20 = 20.20 Air Change Per Hour (CFM) = 1.00

612.00 x 1.00 x1/60 = 10.20 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 52.00

(Room DB - ADP) x CF = 16.10

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 557.54 CFM = 262.04 L/s TOTAL HEAT CAPACITY

SENSIBLE HEAT CAPACITY

CFM =557.54 TR = 1.39 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise Summer

DB (F) SH Gr/Lb

110.00 75.00

10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 612.00

61.20

1st floor Right side DIMENSION

(21)

= 1.46 TR ACCEPT THIS TR 583.51 cfm ACCEPT THIS CFM

(22)
(23)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E SqFt x F x 0.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W 164.00 SqFt x 20.00 F x 0.65 2,132.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 105.00 SqFt x 27.00 F x 0.48 1,360.80 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E SqFt x F x 0.00 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S 0.00 SqFt x 0.00 F x 0.00 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 20.00 SqFt x 35.00 F x 0.65 455.00 Selected ADP (F) Partition 181.60 SqFt x 30.00 F x 0.32 1,743.36

Ceiling 148.68 SqFt x 30.00 F x 0.16 713.66 (Room DB - ADP) x CF

Floor 148.68 SqFt x 30.00 F x 0.16 713.66 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 38.00 CFM x 35.00 T.Diff x 1.08 1,436.40 Dehumidified Rise x 1.08 Outside Air 60.00 CFM x 35.00 T.Diff x 0.3x 1.08 680.40

Internal Heat

People 2.00 Nos. x 245.00 Btu/Hour Per Person 490.00 TOTAL HEAT CAPACITY Lighting 148.68 SqFt x 0.40 W/SqFt x 3.41 204.57 1.95

Equipments 148.68 SqFt x 2.35 W/SqFt x 3.41 1,193.48

Power 0.00 kW/Hpx 0.00 0.00

11,123.34 5-10% 1,112.33

12,235.67

1.00

SENSIBLE HEAT CAPACITY Sub Total

Factor

Effective Room Sensible Heat

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise W ABC Item Area or Quantity Sun Gain or Temp. Diff. Factor Btu/Hour

XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

(24)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 38.00 CFM x 9.00 Gr/Lb x 0.68 232.56 12,000.00

Outside Air 60.00 CFM x 9.00 Gr/Lb x BFx0.68 110.16 People 2.00 Nos. x 205.00 Btu/Hour Per Person 410.00 752.72 2.5 - 5% 37.64

790.36

2.00

EFFECTIVE ROOM TOTAL HEAT 13,026.03

OUTSIDE AIR HEAT

Sensible 60.00 CFM x 35.00 F(TD) x CF x 1.08 1,587.60

3.00

Latent 60.00 CFM x 9.00 Gr/Lb x CF x 0.68 257.04

4.00

OUTSIDE AIR TOTAL HEAT 1,844.64 Notes:

GRAND SUB-TOTAL HEAT 14,870.67

1 - 3% 446.12 15,316.79

TONS=GRAND TOTAL HEAT/12000 1.28

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(25)

10.5 14.16 Area 148.68 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 2.00 = 60.00 0.33 Sqft x 148.68 = 49.06 Air Change Per Hour (CFM) = 1.00

1,486.80 x 1.00 x1/60 = 24.78 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 54.30

(Room DB - ADP) x CF = 14.49

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 781.87 CFM = 367.48 L/s TOTAL HEAT CAPACITY

ACCEPT THIS TR

SENSIBLE HEAT CAPACITY

CFM =781.87 TR = 1.95 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise Summer

DB (F) SH Gr/Lb

110.00 75.00

10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 1,486.80

148.68

1st floor Right side DIMENSION

(26)

= 1.28 TR

(27)
(28)

PROJECT FLOOR

LOCATION SPACE REFERENCE

CLIENT AREA ( SqFt)

CONSULTANT Height (Ft)

Volume (CuFt) Estimate for Design Conditions

ROOM HEAT Ambient

ROOM SENSIBLE HEAT Room

Solar Gain - Glass Difference

Glass - N SqFt x F x 0.00

Glass - NE SqFt x F x 0.00

Glass - E 20.00 SqFt x 12.00 F x 0.65 156.00 By Pass Factor (BF)

Glass - SE SqFt x F x 0.00 Contact Factor (CF = 1 - BF)

Glass - S SqFt x F x 0.00

Glass - SW SqFt x F x 0.00 CFM Per Person

Glass - W SqFt x F x 0.00 CFM Per SqFt

Glass - NW SqFt x F x 0.00 Air Change Per Hour (CFM)

Skylight SqFt x F x 0.00 CFM Cu.ft

Solar & Transmission Gain - Walls & Roof

Wall - N 0.00 SqFt x 0.00 F x 0.00 0.00 window

Wall - NE SqFt x F x 0.00 Revolving Doors (People)

Wall - E 86.60 SqFt x 29.00 F x 0.48 1,205.47 Open Doors

Wall - SE SqFt x F x 0.00 Crack (feet)

Wall - S SqFt x F x 0.00

Wall - SW SqFt x F x 0.00

Wall - W 0.00 SqFt x 0.00 F x 0.00 0.00 Effective Room Sensible Heat Factor =

Wall - NW SqFt x F x 0.00 Effective Room Sensible Heat/Eff Room Total Heat

Roof 0.00 SqFt x 0.00 F x 0.00 0.00

Transmission Gain - Except Walls & Roof Indicated ADP (F) All Glass 20.00 SqFt x 35.00 F x 0.65 455.00 Selected ADP (F) Partition 201.60 SqFt x 30.00 F x 0.32 1,935.36

Ceiling 129.63 SqFt x 30.00 F x 0.16 622.20 (Room DB - ADP) x CF

Floor 129.63 SqFt x 30.00 F x 0.16 622.20 DEHUMIDIFIED Cfm (AIR QUANTITY)

INFILTRATION AND BY PASSED AIR Effective Room Sensible Heat

Infiltration 38.00 CFM x 35.00 T.Diff x 1.08 1,436.40 Dehumidified Rise x 1.08 Outside Air 120.00 CFM x 35.00 T.Diff x 0.3x 1.08 1,360.80

Internal Heat

People 4.00 Nos. x 245.00 Btu/Hour Per Person 980.00 TOTAL HEAT CAPACITY Lighting 129.63 SqFt x 0.77 W/SqFt x 3.41 340.99 1.78

Equipments 129.63 SqFt x 3.47 W/SqFt x 3.41 1,534.44

Power 0.00 kW/Hpx 0.00 0.00

10,648.86 5-10% 1,064.89

11,713.75

1.00

SENSIBLE HEAT CAPACITY Sub Total

Factor

Effective Room Sensible Heat

CFM Ventilation

CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise W ABC Item Area or Quantity Sun Gain or Temp. Diff. Factor Btu/Hour

XYZ

G+5 BUILDING HEAT LOAD Laxmi nagar , New delhi.

(29)

ROOM LATENT HEAT Grand Sensible Heat Infiltration 38.00 CFM x 9.00 Gr/Lb x 0.68 232.56 12,000.00

Outside Air 120.00 CFM x 9.00 Gr/Lb x BFx0.68 220.32 People 4.00 Nos. x 205.00 Btu/Hour Per Person 820.00 1,272.88 2.5 - 5% 63.64

1,336.52

2.00

EFFECTIVE ROOM TOTAL HEAT 13,050.27

OUTSIDE AIR HEAT

Sensible 120.00 CFM x 35.00 F(TD) x CF x 1.08 3,175.20

3.00

Latent 120.00 CFM x 9.00 Gr/Lb x CF x 0.68 514.08

4.00

OUTSIDE AIR TOTAL HEAT 3,689.28 Notes:

GRAND SUB-TOTAL HEAT 16,739.55

1 - 3% 502.19 17,241.74

TONS=GRAND TOTAL HEAT/12000 1.44

Effective Room Latent Heat

Factor GRAND TOTAL HEAT

Sub Total Factor

(30)

12.16 10.66 Area 129.6256 WB (F) RH (%) 75.00 20.00 63.00 50.00 - -= 0.30 Contact Factor (CF = 1 - BF) = 0.70 30.00 No = 4.00 = 120.00 0.33 Sqft x 129.63 = 42.78 Air Change Per Hour (CFM) = 1.00

1,296.26 x 1.00 x1/60 = 21.60 x cfm/window = 0.00 Revolving Doors (People) x cfm/door = 0.00 x cfm/door = 0.00

x cfm/ft = 0.00

0.00 Effective Room Sensible Heat Factor =

Effective Room Sensible Heat/Eff Room Total Heat = =

= 53.25

(Room DB - ADP) x CF = 15.23

DEHUMIDIFIED Cfm (AIR QUANTITY) Effective Room Sensible Heat

Dehumidified Rise x 1.08 = 712.39 CFM = 334.82 L/s TOTAL HEAT CAPACITY

ACCEPT THIS TR

SENSIBLE HEAT CAPACITY

CFM =712.39 TR = 1.78 75.00 66.00 35.00 9.00 CFM Ventilation CFM Infiltration

Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise Summer

DB (F) SH Gr/Lb

110.00 75.00

10.00

INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY 1,296.26

129.63

1st floor Right side DIMENSION

(31)

= 1.44 TR

(32)
(33)

ROOMS TR CFM TR CFM BEDROOM 1.25 501.85 1.92 771.95 DINING 1.42 571.71 1.408 563.5 HALL 1.81 727.12 2.22 890.07 MASTER BEDROOM 1.33 533.15 1.75 703.57 TOTAL TR 7.31 TR TOTAL CFM 2333.83 CFM ROOMS TR CFM TR CFM BEDROOM 1.43 572 2.25 900 DINING 1.6 640 1.63 655.44 HALL 2.39 956 3.16 1267.87 MASTER BEDROOM 1.44 576 1.78 712 ROOMS TR CFM TR CFM BEDROOM 1.18 472 1.78 713.39 DINING 1.6 640 1.64 656 HALL 1.4 560 1.95 782 MASTER BEDROOM 1.43 572 1.81 726 TOTAL TR IN RHS IN 1ST FLOOR 17.0259 TOTAL CFM IN RHS IN 1ST FLOOR 5357.111 TOTAL TR IN 1ST FLOOR 32.2159 TR TOTAL CFM IN 1ST FLOOR 10056.33 CFM 128.8636 TR 40225.32 CFM TOTAL TR 1-5th floor 160.6636 TR total cfm 1-5th floor 50189.32 CFM TOTAL TR UPTO 4TH FLOOR

TOTAL CFM UPTO 4TH FLOOR

G+5 BUILDING HEAT LOAD 1ST FLOOR

CALCULATED DEHUMIDIFIED

LEFT TOP FLAT IN 1ST FLOOR (3)

RIGHT TOP

CALCULATED DEHUMIDIFIED

G+5 BUILDING HEAT LOAD 5th FLOOR

LEFT TOP

(34)

LEFT BOTTOM FLAT IN 1ST FLOOR (4) ROOMS TR CFM TR CFM BEDROOM 1.7 680.8 1024.25 2.56 DINING 1.45 582.7 574.54 1.43 HALL 1.36 547.8 858.87 2.14 MASTER BEDROOM 1.385 554.09 694.63 1.73 TOTAL TR 7.88 TR TOTAL CFM 2365.39 CFM ROOMS TR CFM TR CFM HALL 2.5 1000 3.37 348.02 DINING 1.45 580 1.44 577.92 BEDROOM 1.53 612 2.41 966.29 MASTER BEDROOM 1.37 548 1.67 671.46 ROOMS TR CFM TR CFM BEDROOM 1.2 480 1.74 696.53 DINING 1.47 588 1.41 565.62 HALL 1.32 528 1.59 639.14 MASTER BEDROOM 1.6 640 2.1 840 31.8 TOTAL CFM IN 5TH FLOOR 9964

G+5 BUILDING HEAT LOAD 1ST FLOOR

CALCULATED

RIGHT BOTTOM

CALCULATED DEHUMIDIFIED

TOTAL TR IN 5TH FLOOR

DEHUMIDIFIED

G+5 BUILDING HEAT LOAD 5th FLOOR

LEFT BOTTOM

References

Related documents

Benches 9A, 7B and 6 (the high phosphorus content benches) all have fairly normal frequency distributions of their phosphorus content. This indicates that the phosphorus of these

profession within the previous five years, all respondents, regardless of when they began their first archival jobs, indicated that their preferred providers of contin- uing

On average, island nations have higher a GDP per capita, a lower level of travel receipts, and travel receipts represent a larger percentage of exports than for regular countries.

Reduction in RTs in comparison to HTTP 1.X gained by features such as Multiplexing over one connection, and Server Push HTTP/2 or SPDY can layer on top of QUIC (i.e. all features

Furthermore, regions with higher startup activity in the early and mid 1980s subsequently have higher employment growth rates in the period 1991-98, suggesting that in the 1990s

Six months later, the director of the Nova Freedonia Space Agency and the Zuris Minister for Space Affairs signed a Memorandum of Understanding [hereinafter referred to as

– a) Assessment of user environment against policy requirements: the conformity rules for assessing conformity of SCA or SVA against Policy Requirements. – b) Assessment of