RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

General Specifications

Parameter Symbol Min. Typ. Max. Unit Notes

Data Rate BR 3.1875 Gb/s ARINC 818

Absolute Maximum Ratings

Parameter Symbol Min. Max. Unit Note

Maximum Supply Voltage VCC -0.3 4.0 V

Storage Temperature Tsto -55 100 °C

Case Operating Temperature TOP -40 85 °C

Relative Humidity RH 0 95 % Based on conformal coating

Selective Soldering Temperature 260 °C 10 seconds, leads only (2,3)

Hand Lead Soldering Temperature 260 °C 10 seconds, leads only (2,3)

Conformal Coating 0.8 1.2 mil See ruggedization notes

Notes:

1) RJ transceivers may be water washed. The process must be followed by an 80°C bake for one hour to ensure the drying of any water inside the shell.

2) Solder Posts do not transmit data and do not need a complete solder fill. 3) The components should not undergo Wave Soldering under any circumstances.

The RJ-3G-RX2 is ideal for

harsh environment

connectivity because of its

low cost, availability, and

wide operating parameters

Features:

 Compliant to ARINC 818 1.0625 Gb/s and 3.1875 Gb/s

data rates

 Dual 850nm VCSEL PIN receiver

 Rugged LC connector housing including screw mounted

OSAs

 1x10 connector pinout

 MIL-STD-883

certified

 -40 to +85 °C operating temperature, wider options

available

 Option for RoHS compliant and lead free per Directive

2002/95/EC

 Single +3.3V power supply

 Receivers

AC-Coupled

 Low power dissipation

(2)

RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

Electrical Specifications

(TOP = -40 to 85°C, VCC = 3.135 to 3.465 Volts)

Parameter Symbol Min. Typ. Max. Unit Notes

Supply Voltage VCC 3.135 3.465 V +/-5%

Total Module Power Dissipation PDISS 0.60 0.80 W

Receiver

Supply Current ICC 85 120 mA

Output differential impedance 100 Ω CML

Output Voltage Swing V p-p 0.60 0.75 0.94 V Differential output

Output Rise/Fall Time 70 150 ps 20%-80%

Signal Detect Assert SDA 2.4 VCC V LVTTL

Signal Detect De-assert SDD VEE VEE +0.5 V LVTTL

Pin Configuration

PIN # Symbol Description Logic/ Protocol

1 RD2+ Receiver 2 Non-inverted DATA out. AC Coupled CML 2 VEER2 Receiver 2 Ground

(Common with Transmitter Ground) N/A 3 RD2- Receiver 2 Inverted DATA out. AC Coupled CML

4 VCCR2 Receiver 2 Power Supply N/A

5 SD1 Signal Detect 1 output

Satisfactory Optical Input: Logic “1” Output

Fault Condition: Logic “0” Output

LVTTL 6 SD2 Signal Detect 2 output

Satisfactory Optical Input: Logic “1” Output

Fault Condition: Logic “0” Output

LVTTL

7 RD1+ Receiver 1 DATA Out + CML

8 VCCR1 Receiver 1 Power Supply N/A

9 RD1- Receiver 1 DATA Out - CML

10 VEER2 Receiver 1 Signal Ground N/A

Optical Characteristics

(TOP = -40 to 85°C, VCC = 3.135 to 3.465 Volts)

Parameter Symbol Min. Typ. Max. Unit Notes Receiver

Receiver Sensitivity: RXSENS -15 dBm 3.1875

Average Received Power RXMAX 0 dBm

Receiver Elec. 3 dB cutoff freq. 3000 MHz

Optical Center Wavelength C 830 860 nm

Return Loss RL 12 dB

Signal Detect Assert PA -15 dBm

Signal Detect De-Assert PD -30 dBm

Signal Detect Hysteresis PA - PD 0.5 2.25 5 dB

Notes:

(3)

RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

PCB Design Guidelines

Equivalent Circuits

RD+ RD-VCCR C1 C2 50 50

Optical Receive Output Equivalent Circuit 50 ohm single-ended output, AC coupled, CML compatibility C1,C2 = 0.01uF

Drawing shows entire RJ device and dotted line represents laser driver. RJ-3G-RX2 is interally AC coupled.

(4)

RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

Panel Cutout

Minimum recommended pitch is 0.600”

Front View, dimensions in mm (inches) Side View, dimensions in mm (inches)

Screw Post Mechanical Dimensions

Front View, dimensions in mm (inches) Side View, dimensions in mm (inches)

Screw Dimensions

(5)

RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

Ruggedization Notes

 Parylene C coating can be used for conformal coating with a 1.0 mil ± 0.2 mil thickness through a deposition process. Parylene Type C has a 5600 VPM rating, withstands temperatures of 350°F, and is extremely resistant to oil/dirt, and object impact.

 Another option for conformal coating is Cytec Conathane® CE1155 is applied as a 1.5 mil film, which meets MIL-I-46058-C. It has resistance to moisture and abrasion. It is clear with a UV additive and has a 3000 VPM rating.

 This part can come in a pigtail fiber optic version.

 Contact COTSWORKS for all MSDS and case composition.

An optional label or coating may be applied to prevent damage to the label during a chlorine wash.

Reference Information

1) IEEE Standard 802.3, 2002 Edition, 1000BASE-X. IEEE Standards Department, 2002

2) “Fibre Channel Draft Physical Interface Specification (FC-PI-2 Rev. 10.0)”. American National Standard for Information Systems

3) Infiniband 1.2.1 specification, www.infinibandta.org

4) 3.125 Gb/s XAUI specification, IEEE 802.3ae, section 47

5) ARINC 818 specification at 3.1875Gb/s, https://www.arinc818.com/

6) Directive 2002/95/EC of the European Council Parliament and of the Council, “on the restriction of the use of certain hazardous substances in electrical and electronic equipment.” January 27, 2003

Regulatory Compliance

 COTSWORKS transceivers are Class 1 Laser Products and comply with US FDA regulations.

 These products comply with TÜV and CSA Class 1 eye safety requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC) 60950.

 This part has an option for compliance with Directive 2002/95/EC covering restriction on certain hazardous substances (RoHS). It invokes item 5 of the Annex which allows “Pb in the glass of cathode ray tubes, electronic components, and fluorescent tubes.” This part may contain Pb for components such as lenses, windows, isolators, and other electronic components

Warnings:

Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free

environment is highly recommended.

Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect

(6)

RJ-3G-RX2

Rugged RJ Size Dual 1Gb/s to 3Gb/s

Fiber Optic Receiver

Ordering Information

RJ-3G-RX2 -xx- x -x- x -x- x RJ Form Factor 3Gbps Max Data Rate Dual Receivers (MMF) Connector Ruggedized

Coating Operating Temp Range

EMI

Shield? RoHS Level Mounting

LC A: -40 to 85C M: -40 to 95C (): Imperial U: Metric P: Solder Posts (): Non-coated R: Parylene (): No Shield E: Shield (): Lvl 5 6: Lvl 6

Example part number: RJ-3G-RX2-LC-R-A-U

[3G RJ Form Factor Dual Receiver, dual LC connectors, Parylene-coated, Industrial operating temperature range, Metric Screw Post Mounting]

References

Related documents

HARTING offers the matching sockets and the ideal connectors for quick and safe connection of the 2- or 4-pair Ethernet cable to the appliance. Users can rely either on

• Dual port copper 1Gb (1000 Base) Ethernet PCIe NIC with RJ-45 connectors (DD670 system only). • Quad port copper 1Gb (1000 Base) Ethernet PCIe NIC with

• S’assurer que les opérateurs du pont élévateur soient qualifiés et formés pour utiliser d’une façon sécuritaire et selon les instructions du fabricant ; ALI/SM01-1, manuel

Circuit Breaker Type Circuit Breaker Type Number of Poles Number of Poles Westinghouse Series C ® Molded Case Circuit Breakers N-Frame 400-1200 Amperes March 1996.. Supersedes

As the small nonroad engine owner, you should, however, be aware that Husqvarna Forest & Garden may deny you warranty coverage if your small nonroad engine or a part of it

A SIP Application Layer Gateway (ALG) provides functionality to allow VoIP traffic to pass both from the private to public and public to private side of the firewall when using

After using a USB connection to install the drivers and the Printer Setting Tool on the computer, you can use the Network Setting Tool to easily configure network settings

Connect the fiber optic cables from the Peripheral Slot FIM Carrier in the Peripheral Cabinet to the connectors on the SUPERSET HUB unit.. Connect the RJ-45 connectors to the