ETAP allows for commonly used keyboard shortcuts which are listed below:
Undo Control + Z
Redo Control + Y
Copy Control + C
Paste Control + V
Delete Control + X
Rotate 90 degrees Clockwise Control + R
Rotate 90 degrees Counterclockwise Control + Shift + R
Save Project Control + S
Save Project As Control + Shift + S
Open Project Control + O
Create New Project Control + N
Print Control + P
Print Preview Control + Shift + P
Pan Space Bar + Left Mouse
Fit in Window Control + 0
Copy and drag element to another window Control + Shift + Left Mouse Button
Switch Windows Control + F6
Previous Window Control + Shift + F6
Select all components in the active presentation Control + A Deselect all components in the active presentation Control + Shift + A Switch to the System Dumpster as the Active Window Control + D
Switch directly to Edit Mode Control + E
Brings up the Find tool window Control + F
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Ungroup Selected Elements Control + U
Brings up the Options/Preferences window Control + K Switch to the module to the right of the active study Control + M included in the mode toolbar
Closes the project file Control + Q
Move from Dumpster in Edit Mode Control + Shift + V
For selected components, increase the symbol size to the + “Plus Sign” next size: Size Range: 1-5
For selected components, decrease the symbol size to the - “Minus Sign” next size: Size Range: 1-5
Switch Windows Control + F6
Go back to the previous Window Control + Shift + F6
Closes the active window/presentation Control + F4
Move selected elements left by 1 unit Control + Left Arrow Move selected elements right by 1 unit Control + Right Arrow Move selected elements up by 1 unit Control + Up Arrow Move selected elements down by 1 unit Control + Down Arrow Move selected elements left by 2 units Left Arrow
Move selected elements right by 2 units Right Arrow
Move selected elements up by 2 units Up Arrow
Move selected elements down by 2 units Down Arrow
Zoom into the One Line View Control + “Plus Sign”
Zoom out of the One Line View Control + “Minus Sign”
Zoom into the One Line View Control + Mouse Scroll Wheel Up
Zoom out of the One Line View Control + Mouse Scroll Wheel Down
Permanently delete selected elements without sending them Shift + Delete to the dumpster
Menu Bar
The Menu bar contains a comprehensive list of menu options. Each option activates a drop-down list of commands such as, File operations, Printing, Database Conversions, Data Exchange, OLE objects, Project Standards, Project Settings and Project Options, Libraries, Defaults, Annotation Fonts, Base and Revision Data, and more.
Project Toolbar
The Project toolbar contains buttons that provide shortcuts for many commonly used functions. Those functions are: New Project, Open Project, Save Project, Print, Print Preview, Cut, Copy, Paste, Pan, Zoom, Back, Forward, Zoom to Fit Page, Undo, Redo, Text Box, Grid Display, Continuity Check, Switching Interlock Enforcer (SIE), Hyperlink, Power Calculator, Find, and Help.
N ew O pen C lose Prin t Pri n t Pr evi ew Cut C opy Past e Pan Zoom In Zoom Ou t B ac k Forwar d Zoom to Fi t Pa ge U ndo R edo Text B ox Polyl ine T ext B ox Show G ri d L ine s C hec k C on ti nu it y SIE H yper li nk s Pow er C al cu lat or Find Hel p
Theme Toolbar
The Theme toolbar contains buttons that allow you to perform shortcuts using commands to change color and line styles for device connectors, symbol color, and background.
Them e Ma nage r Them e N am e Them e C ol o r C od ing Them e N am e C ol or s Nor m al C ol or s Cust om Enabl e C ont o ur ing
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
3-D Database Toolbar
ETAP organizes an electrical system into a single project. Within this project, ETAP creates three major system components:
Presentation - Unlimited, independent graphical presentations of the one-line diagram that represent design data for any purpose (such as impedance diagram, study results, or plot plan).
Configuration - Unlimited, independent system configurations that identify the status of switching devices (open and closed), motors and loads (continuous, intermittent, and spare), generator operating modes (swing, voltage control, reactive power control, power factor control) and MOVs (open, closed, throttling, and spare).
Revision Data - Base Data and unlimited Revision Data IDs that keep track of the changes and modifications to the engineering properties (for example, nameplate or settings) of elements.
1. Data Manager 2. Revision Data 3. New Presentation 4. Current Presentation 5. Current Composite 6. Configuration Manager 7. Configuration Status 8. Schedule Report Manager 9. Cable Manager
The Schedule Report Manager allows you to preview and print the input data, for elements shown on the Branch, Bus and Load pages, using the Crystal Reports formats.
The Cable Manager allows the “batch” management of all the cable data, as they appear in the Cable Editors of each cable. The Cable Manager shows cable data in a consolidated fashion in a grid; with the presence of intelligent filters, cables can be searched and grouped by their relevant parameters, thereby simplifying their engineering management. Cable Manager allows batch reporting and selecting from library.
2
Edit Mode
Here you can graphically add, delete, relocate, and connect elements, zoom in or out, display grid off or on, change element size, change element orientation, change symbols, hide or show protective devices, enter properties, set operating status, and more.
Edit Mode
Select Status Configuration
Unlimited Number of Configurations to Save Status of Switching Devices/Loads
Select Mode
Edit Mode: Drag/Drop & Connect Elements Study Mode: Edit Mode, Load Flow, Short-Circuit, etc.
System Manager
One-Line Diagram
In Edit Mode
Help Line
Displays the description for every entry field
Edit Toolbar
AC Elements DC Elements Instrument
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Edit Toolbars
The Edit toolbars are active when you are in Edit Mode. You can click or double-click to select, drag and drop AC, DC, and instrument elements on the one-line diagrams. Additionally, you can perform the following functions:
View & Print Customizable Output Reports (Text & Crystal Reports)
Change Display Options
Access Schedule Report Manager
Add New Ground Grid Systems
Add Composite Networks & Composite Motors AC Edit Toolbar: Pointer Bus/Node Auto Connection Transformer, 2-Winding Transformer, Open-Delta Cable Reactor, Current Limiting
Transformer, 3-Winding Bus Duct
Transmission Line Impedance Power Grid (Utility System)
Wind Turbine Generator Induction Machine Lumped Load Static Load Panel System Remote Connector Grounding/Earthing Adapter Static Var Compensator
Generator, Synchronous PV Array
Motor, Synchronous
Motor Operated Valve (MOV) Capacitor
Harmonic Filter Phase Adapter MG Set (Rotary UPS) HVDC Transmission Link Composite Motor Composite Network
Fuse High Voltage Circuit Breaker Recloser Overload Heater Single Throw Switch
Contactor
Low Voltage Circuit Breaker Ground Switch
In-line Overload Relay Double Throw Switch
Instrumentation Toolbar Display Options
Ground Grid
Instrumentation Element Toolbar:
Current Transformer Potential Transformer Voltmeter Multimeter Ammeter Voltage Relay Frequency Relay Motor Relay Differential Relay Tag Link Power Relay
MV Solid State Relay Overcurrent Relay Multi-Function Relay DC Edit Toolbar: Pointer DC Bus DC Cable DC-DC Converter DC Impedance Battery DC Motor DC Lumped Load DC PV Array DC Static Load DC Composite CSD DC Composite Motor DC Composite Network
DC Circuit Breaker DC Switch, Single-Throw
DC Fuse
DC Switch, Double-Throw
Uninterruptible Power Supply (UPS) Charger
Variable Frequency Drive (VFD) Inverter
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Study Modes
ETAP provides the following study modes from the one-line diagram: 1. Load Flow Analysis
2. Short-Circuit Analysis 3. Arc Flash Analysis
4. Motor Acceleration Analysis 5. Harmonic Analysis
6. Transient Stability Analysis
7. Star – Protection and Coordination Analysis 8. DC Load Flow Analysis
9. DC Short-Circuit Analysis 10. DC Arc Flash Analysis
11. Battery Sizing and Discharge Analysis 12. Unbalanced Load Flow Analysis 13. Optimal Power Flow Analysis 14. Reliability Assessment 15. Optimal Capacitor Placement 16. Switching Sequence Management 17. Contingency Analysis 17 16 3 2 1 4 5 6 7 8 9 10 11 12 13 14 15
System Toolbar
The System toolbar is a convenient and efficient method of switching between ETAP systems. When navigating from one ETAP system to another using this toolbar, ETAP will open the last accessed presentation for the selected system. For example, if you are switching from Network Systems to Star Systems, ETAP will check for an existing Star View. If Star Views exist, ETAP will open the last accessed Star View and make it the active window.
System Manager One-Line Diagrams Star Systems
Underground Raceway Systems Ground Grid Systems
Cable Pulling Systems ETAP Real-Time Systems
Geographical Information Systems (Data Adapter) AC Control Systems Diagram (CSD)
DC Control Systems Diagram (CSD)
Geographical Information Systems (GIS View)
User-defined Dynamic Model (UDM) Graphical Editor System Dumpster
Scenario Wizard Study Wizard Project Wizard
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
ETAP Wizards
ETAP includes time-saving project management tools called the ETAP Wizards, which allow you to record and run any study at any time. The ETAP Wizards include the Scenario Wizard, Study Wizard, and Project Wizard.
Using the ETAP Wizards, you will be able to combine the orthogonal tools (Presentations, Configurations, and Revision Data), study types, output reports, and study cases (the loading and generation system operation factors together with solution parameters) to perform a complete system study with the click of a button.
Scenario Wizard:
A scenario allows you to group all study options into one place.
Study Wizard:
Study Wizard enables you to sequentially group existing scenarios into study macros.
Project Wizard:
Project Wizard enables the user to group existing study macros into project macros.
Scenario Wizard Study Wizard Project Wizard
Crystal Reports
®ETAP uses the Crystal Reports program to generate output reports. Crystal Reports is a reporting tool with customizable report formats with full-color presentation-quality. ETAP provides a number of different report formats for various analyses, library data, and schedules.
Load Flow Report Manager Button Report Manager Button Input, Results, & Summary Data
Selected Report Formats
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Building a One-Line Diagram
To build or edit a one-line diagram in ETAP, you must be in Edit Mode. Click the Edit button on the Mode toolbar.
On the AC Edit toolbar, select a Power Grid (Utility) element by clicking on the Power Grid button. The cursor will change to the Power Grid icon when moving over the OLV. Click anywhere in the OLV to place a Utility on your one-line diagram.
By following the same procedure, insert the following elements until your OLV appears as follows:
You can stretch buses by placing the mouse pointer over either end of the bus, until a double arrow appears. Then click and drag to the desired length.
Now connect the elements in the one-line. Place the mouse pointer over the connection pin ofan element, and it will turn red. Then click and drag to the connection pin of another element. Follow this procedure to connect all the elements on the one-line. In the case of buses, the entire element graphic functions as a connection point. Notice that a node is automatically inserted when connecting the cable to the transformer.
☺Helpful Tips…
Double-clicking on an element button allows you to drop it more than once. When finished just press the Esc key.
☺Helpful Tips…
You can zoom in , zoom out , and zoom to fit page the OLV by clicking on the respective buttons located in the Project Toolbar.
Libraries
ETAP provides customized libraries for many devices for which typical, standard, and manufacturer information has been compiled. Additional devices may be added to each library through ETAP’s library editors. ETAP library files have the extension .lib and by default are located in the ‘Lib’ folder within the ETAP application folder. ETAP displays this path along with the name of the current library in the System Manager.
You may access library data through the Crystal Report format by clicking the Library button at the top of the screen and selecting Export.
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Load Flow Analysis
Click the Load Flow Analysis button on the Mode toolbar to switch to Load Flow Analysis mode.
Run Load Flow Studies Auto Run
Halt Current Calculation Alert View
Report Manager
Load Flow Result Analyzer Load Flow Comparator Display Options Unit Display Options Power Flow Display Options Voltage Display Options Load Terminal Voltage Line / Cable Voltage Drop Panel / Single Phase System Get Online Data
Get Archived Data Run SLE Load Flow Load Analyzer
Short-Circuit Analysis
ANSI Short-Circuit Toolbar
This toolbar is active when you are in Short-Circuit Mode and the standard is set to ANSI in the Short-Circuit Study Case Editor.
3-Phase Faults – Device Duty
Panel / 1-Phase UPS / 1-Phase System Device Duty LG, LL, LLG & 3-Phase Faults – ½ Cycle
LG, LL, LLG & 3-Phase Faults – 1.5 - 4 Cycle LG, LL, LLG & 3-Phase Faults – 30 Cycle Display Options
Alert View Report Manager
Short-Circuit Result Analyzer Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
IEC Short-Circuit Toolbar
This toolbar is active when you are in Short-Circuit Mode and the standard is set to IEC in the Short-Circuit Study Case Editor.
3-Phase Faults – Device Duty (IEC 60909)
Panel / 1-Phase UPS / 1-Phase System Device Duty LG, LL, LLG & 3-Phase Faults (IEC 60909) 3-Phase Faults – Transient Study (IEC 6136) Display Options
Alert View Report Manager Plots
Short-Circuit Result Analyzer Halt Current Calculation Get Online Data
GOST Short-Circuit Toolbar
This toolbar is active when you are in Short-Circuit Mode and the standard is set to GOST in the Short-Circuit Study Case Editor.
3-Phase Device Duty
Maximum LG, LL, LLG & 3-Phase Faults Maximum LG, LL, LLG & 3-Phase Faults Display Options
Unit Display Options
Fault Current Type Display Options Alert View
Report Manager
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Arc Flash Analysis
Click the Arc Flash Analysis button on the Mode toolbar to switch to Arc Flash Analysis mode.
Run Global 3-Phase Arc Flash Analysis Calculation Run Global 1-Phase Arc Flash Analysis Calculation
AF SQOP Fault Insertion (drop on bus to place an AF SQOP simulation) AF SQOP Fault Insertion (for 1-phase to be enabled in a future release) AF SQOP Event Viewer
Create a TCC from Arc Flash Mode (same as creating a TCC from Star mode) Append a device to an existing TCC (same as append in Star Mode)
Display Options Alert View Report Manager
Arc Flash Result Analyzer Halt Current Calculation Get Online Data
Motor Acceleration Analysis
Click the Motor Acceleration Analysis button on the Mode toolbar to switch to Motor Acceleration Analysis mode.
Run Dynamic Motor Starting Run Static Motor Starting Display Options
Alert View Report Manager Plots
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Harmonic Analysis
Click the Harmonic Analysis button on the Mode toolbar to switch to Harmonic Analysis mode.
Run Harmonic Load Flow Run Frequency Scan Display Options Alert View Report Manager Plots
Halt Current Calculation Get Online Data
Transient Stability Analysis
Click the Transient Stability Analysis button on the Mode toolbar to switch to Transient Stability Analysis mode.
Run Transient Stability Display Options Alert View Report Manager Action List Plots
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Star Protection and Coordination Analysis
Click the Star Protection and Coordination Analysis button on the Mode toolbar to switch to Star Protection and Coordination Analysis mode.
Create Star View Star View Manager
Run / Update Short-Circuit Clipping kA
Run / Update 1-Phase Short-Circuit Clipping kA Fault Insertion (PD Sequence-of-Operation) Sequence Viewer
Path Detection Tools Protection Zone Viewer Star Auto-Evaluation
Star Auto-Evaluation Report Viewer Display Options
Report Manager Device Settings Report Halt Current Calculation Halt Current Calculation Get Online Data
DC Load Flow Analysis
Click the DC Load Flow Analysis button on the Mode toolbar to switch to DC Load Flow Analysis mode.
Run DC Load Flow Studies Display Options
Report Manager
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
DC Short-Circuit Analysis
Click the DC Short-Circuit Analysis button on the Mode toolbar to switch to DC Short-Circuit Analysis mode.
Run DC Short-Circuit Studies Display Options
Report Manager
Halt Current Calculation Get Online Data
DC Arc Flash Analysis
Click the DC Arc Flash Analysis button on the Mode toolbar to switch to DC Arc Flash Analysis mode.
Run DC Arc Flash Studies Create Star View
Star View Manager Display Options Report Manager
DC Arc Flash Result Analyzer Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Battery Discharge and Sizing
Click the Battery Discharge and Sizing button on the Mode toolbar to switch to Battery Discharge and Sizing mode.
Run Battery Sizing Study
Run Battery Discharge Calculation Display Options
Report Manager Plots
Halt Current Calculation Get Online Data
Unbalanced Load Flow Analysis
Click the Unbalanced Load Flow Analysis button on the Mode toolbar to switch to Unbalanced Load Flow Analysis mode.
Run Unbalanced Load Flow Studies Run Open Phase Fault Studies Halt Current Calculation Alert View
Report Manager Plots
Display Options Unit Display Options Power Flow Display Options Voltage Display Options Show Average / Phases Load Terminal Voltage Line / Cable Voltage Drop Panel / Single Phase System Get Online Data
Get Archived Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Optimal Power Flow Analysis
Click the Optimal Power Flow Analysis button on the Mode toolbar to switch to Optimal Power Flow Analysis mode.
Run Optimal Power Flow Display Options
Report Manager
Halt Current Calculation Get Online Data
Reliability Assessment
Click the Reliability Assessment button on the Mode toolbar to switch to Reliability Assessment mode.
Run Distribution System Reliability Analysis Display Options
Output Report Plots
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Optimal Capacitor Placement
Click the Optimal Capacitor Placement button on the Mode toolbar to switch to Optimal Capacitor Placement mode.
Run Optimal Capacitor Placement Display Options
Alert View Report Manager Plots
Halt Current Calculation Get Online Data
Switching Sequence Management
Click the Switching Sequence Management button on the Mode toolbar to switch to Switching Sequence Management mode.
Run Switching Sequence Display Options
Report Manager
Halt Current Calculation Get Online Data
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Contingency Analysis
Click the Contingency Analysis button on the Mode toolbar to switch to Contingency Analysis mode.
Run Contingency Analysis Display Base Load Flow Display CA Load Flow Display Options Report Summary Report Manager Performance Index List Halt Current Calculation Get Online Data
Get Archived Data Action List
Underground Raceway Systems
Click the Underground Raceway Systems button on the System toolbar to switch to Underground Raceway Systems mode.
Edit Mode
Select Edit in the Underground Raceway Systems Mode toolbar to switch to Edit Mode.
Pointer Existing Direct Buried Raceway Existing Cable Existing Duct Bank Raceway New Conduit Existing External Heat Source Display Options
New Raceway
New Direct Buried Raceway New Cable
New Duct Bank Raceway New Location
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Study Toolbar
Select U/G Cable Raceways in the Underground Raceway Systems Mode toolbar to switch to Study Mode.
Steady-State Cable Temperature Calculation Cable Ampacity Calculation, Uniform Ampacity Cable Ampacity Calculation, Uniform Temperature Cable Sizing
Transient Cable Temperature Calculation Display Options
Report Manager Plots
Halt Current Calculation Get Online Data
Ground Grid Systems
The Ground Grid Systems Presentation is a separate application within ETAP. New grid systems may be created by clicking on the Ground Grid element button on the AC Edit toolbar and then clicking in your OLV to place the element. Double-click the grid graphic in the OLV to open the Ground Grid Presentation window. Choose a default calculation method to begin.
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Users may click the Ground Grid Systems button on the System toolbar to switch to Ground Grid Systems mode.
Edit Toolbar
Select the Edit button in the Ground Grid Systems Mode toolbar to switch to Edit Mode.
The IEEE Editor Toolbar appears when the IEEE Study Model is selected. The FEM Editor Toolbar appears when the FEM Study Model is selected.
IEEE Editor Toolbar Finite Element Method (FEM) Editor Toolbar
Pointer
IEEE Rectangular Shape IEEE T-Shape
IEEE L-Shape
IEEE Triangular Shape
Pointer Conductor Rod
FEM Rectangular Shape FEM T-Shape
FEM L-Shape
FEM Triangular Shape
Study Toolbar
Select the Ground Grid Study button in the Ground Grid Systems Mode toolbar to switch to Study Mode.
Ground-Grid Calculation Optimized Conductors
Optimized Conductors and Rods Summary and Warning
Display Options Plot Selection Report Manager Stop
This document and the information within it are confidential and proprietary to ETAP/Operation Technology, Inc. and may not be modified, copied,
Cable Pulling Systems
Click the Cable Pulling Systems button on the System toolbar to switch to Cable Pulling Systems mode.
Existing Cable New Cable New Segment
Calculate Cable Pulling Report Manager Summary and Warning Display Options