The Complete and Comprehensive solution for implants!

Edison Medical Ltd. is engaged in the import, export, marketing and distribution of dental Implants and other related products.

Edison Medical is a dynamic rapidly growing company specialized in compatible products for different systems existing in the market. Our mission is to produce high quality products affordable.

Edison Medical ’s Quality Strategy:

Edison Medical’s quality management operates in conformity with ISO QMS standards, 9001/2008 and IS0 13485/2003 (Medical).

Edison Medicals’ systems and Components are being tested to comply with medical standard and European Noti-fied Body (CE 1023) for medical equipments manufacturers.

Edison Medical ‘s Clinical Advantages:

:: Minimal drilling during transplantation.

:: Self tapping for easy insertion and bone condensing for a better primary stability.

:: Insertion kit which prevents bone heating and bone tissue trauma.

:: Flexible superstructure parts for prosthesis stabilization. :: Grade 5 titanium compatibility and security.

:: Sand blasted and acid to improve osseointegration.

:: Screw thread, double thread for better bone contact.

:: Conical and hexagonal connection for indexation and antirotation.

(3)

3

IMPLANTS CATALOG

CLEANING PROCCESS

Special Cleaning Considerations:

:: Composition of the particles

:: Identity of any treatments to remove particles from implant surfaces

:: Identity of agents used in particle removal

:: Chemical analysis of the surface to verify that any chemicals used to remove particles have been washed from the

surface

:: Photomicrographs of blasted surfaces to show whether or not there are particles remaining behind on the surface

:: Prior to sterilization by radiation, all implants go through a process for cleaning after the manufacturing process

(pre-sterilization). The steps are: Washing after machining, Aluminal Blasting, and Acid Treatment

Source:

Surface Analysis of Dental Implants by SEM / EDS, Certificate No. 11-0225-NODI

The analysis was executed using the facilities of the Material Engineering Faculty of the Israel Technion Institute: FEI Quan-ta scanning electron microscope (SEM) and Inca X-ray analyzer atQuan-tached to the electron microscope.

The analysis included: Inspection of the surface in backscattering electrons, which due to good elemental contrast, enables detection of the impurities on the surface of the implants, EDS analysis of the typical impurity particles.

Surface examination by means of SEM / EDS analysis:

Edison Medical use an advanced and thorough implant cleaning process for all dental implants to ensure surface structure and surface chemical composition and its purity grade.

All implant products follow a multi-stage cleaning path before declared medically clean and ready for the packag-ing process.

200

µm

1000

µm

5000

(4)

Item Catalog Number, Catalog Name, and Barcode Do Not Re-Use

Caution: U.S. Federal Law Restricts this device to sale by or on the order of a licensed dentist Caution on use of package content If package is opened or damaged None Sterile product

Consult On-Line Documents and website

Product Catalog Number, Barcode Product Description Batch Code Use By Date Sterilized by Irradiation Regulatory Compliance Manufacturer address Batch Code

Product Label Description

Diameter Color Coding

Implants Inner Label Description

PACKAGING

LA-XXXXXX

CAT# LA-XXXXX

www.edisonmed.com Edison Medical Ltd. PO Box 616, Zichron Ya’akov, 3090000, Israel Tel.: +972.74.7022.771 003018 003018

Lamina Conical Dental Implant

Lamina Conical Dental Implant LAMINA D3.75 L13 1-2015

Ø

3.3

mm

Ø

3.75

mm

Ø

mm

4.2

Ø

mm

5.0

Ø

mm

6.0

Tube cap Implant holder Implant Internal tube Cover screw Cover screw holder

(5)

5

IMPLANTS CATALOG

MEET OUR IMPLANTS

Our development team is proud to introduce our new implants:

Lamina, Fortis & Wan.

Those three implant systems provide you with a wide selection of solutions to your

im-plant cases.

We have created a one size internal hex (2.45mm) for all implants’ diameters for

simplic-ity and ease of use. All implants are self tapping and have dual threads for best primary

stability. Moreover, The technique used to create the SLA surface – Sand-blasted, Large

grit, Acid-etched – is now the industry standard and leads to optimal cell adherence and

proliferation in the cavities of the roughened implant surface.

ONE PLATFORM SIZE FOR ALL IMPLANTS DIAMETERS

All our implant diameters have the same hex size and all prosthetic parts can

be used on all implant platforms.

(6)

CONNECTION

:: One platform for all diameters :: Precise internal hex 2.45mm :: Simple and well-known restoration

NECK

:: Rough Surface to the top :: Micro threads to the top

BODY & CORE

:: Tapered body & core

:: Bone condensing

:: High primary stability

THREADS

:: Double thread design :: Self drilling & tapping :: Easy insertion :: Bone Condensing

APICAL

:: Flat apical :: Sharp threads :: Easy penetration

:: Narrow core & wide threads

Neck Ø  Ø 3.3mm Ø 3.75mm Ø 4.2mm Ø 5.0mm Ø 6.0mm — — 6mm 6mm 6mm — 8mm 8mm 8mm 8mm 10mm 10mm 10mm 10mm 10mm 11.5mm 11.5mm 11.5mm 11.5mm 11.5mm 13mm 13mm 13mm 13mm — 16mm 16mm 16mm — — ApexØ  Ø 2.3mm Ø 2.75mm Ø 3.2mm Ø 4mm Ø 5mm

The Lamina® is the ideal solution for immediate loading and immediate implantation after

extractions.

Thanks to its outstanding self-drilling capabilities and unique spiral body design, the Lamina implant enable you to change its position during placement and helps to achieve with a very high primary stability in bone type D3 & D4.

Neck Ø

2.45mm Hex

NeckØ

(7)

7

IMPLANTS CATALOG

Drill Sequences for Lamina

1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 200-500 Ø 3.3 15-25 Ø 3.3

Ø

3.3mm

Optional Bone D1 &D2 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 200-500 Ø 3.75 15-25 Ø 3.75

Ø

3.75mm

Optional Bone D1 &D2 Optional Bone D1 &D2 Optional Bone D1 & D2 Optional Bone D1 & D2 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 200-500 Ø 4.2 15-25 Ø 4.2

Ø

4.2mm

1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 400-600 Ø 4.2 200-500 Ø 5.0 15-25 Ø 5

Ø

5.0mm

1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 400-600 Ø 4.2 300-500 Ø 5.2 200-500 Ø 6.0 15-25 Ø 6

Ø

6.0mm

Drill sequences recommended by Edison Medical can not replace the judgment and professional experience of the surgeon.

Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter

(8)

Neck Ø  Ø 3.3mm Ø 3.75mm Ø 4.2mm Ø 5.0mm Ø 6.0mm — — 6mm 6mm 6mm — 8mm 8mm 8mm 8mm 10mm 10mm 10mm 10mm 10mm 11.5mm 11.5mm 11.5mm 11.5mm 11.5mm 13mm 13mm 13mm 13mm — 16mm 16mm 16mm — — ApexØ  Ø 2.3mm Ø 2.75mm Ø 3.2mm Ø 4mm Ø 5mm

The Fortis® has a semi-conical implant body and its thread shape are less aggressive

than Lamina.

This design provides minimal pressure on dense bone and slight bone compression and therefore, most suitable for use with bone types D1 & D2.

Neck Ø 2.45mm Hex NeckØ ApexØ

CONNECTION

:: One platform for all diameters

:: Precise internal hex 2.45mm

:: Simple and well -known restoration

NECK

:: Rough Surface to the top

:: Micro rings to the top

BODY & CORE

:: Tapered body & core

:: Bone condensing

:: High primary stability

THREADS

:: Less aggressive

::Double thread design

:: Self drilling & tapping

:: Easy insertion

:: Bone Condensing

APICAL

:: Flat apical

:: Sharp threads

(9)

9 IMPLANTS CATALOG 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 200-500 Ø 3.3 15-25 Ø 3.3

Ø

3.3mm

Optional Bone D1 & D2 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 200-500 Ø 3.75 15-25 Ø 3.75

Ø

3.75mm

Optional Bone D1 & D2 Optional Bone D1 & D2 Optional Bone D1 & D2 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 200-500 Ø 4.2 15-25 Ø 4.2

Ø

4.2mm

1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 400-600 Ø 4.2 200-500 Ø 5.0 15-25 Ø 5

Ø

5.0mm

1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 400-700 Ø 3.2 400-600 Ø 3.65 400-600 Ø 4.2 300-500 Ø 5.2 200-500 Ø 6.0 15-25 Ø 6

Ø

6.0mm

Optional Bone D1 & D2

Drill sequences recommended by Edison Medical can not replace the judgment and professional experience of the surgeon.

Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter

(10)

The Wan® implant is a monoblock implant indicated in narrow alveolar ridges and where space is

limited.

The implant integrates its gold color superstructure, aimed for an immediate loading and suitable for use in all types of bone.

Neck Ø  Ø 3.0mm Ø 3.3mm 10mm 10mm 11.5mm 11.5mm 13mm 13mm 16mm 16mm ApexØ  Ø 1.8mm Neck Ø 2.45mm NeckØ ApexØ

INTEGRATED ABUTMENT

:: Trans-gingival gold oxide coating

:: Great aesthetic results

:: High biocompatibility

TRANS-GINGIVAL NECK

::Better restoration control

:: Can be placed at bone level or below

BODY & CORE

:: Tapered body & core

:: Bone condensing

:: High primary stability

THREADS

:: Single thread design

:: Self tapping

:: Easy insertion

:: Bone Condensing

APICAL

::Narrow rounded apical

(11)

11 IMPLANTS CATALOG 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.5 15-25 Ø 3.0

Ø

3.0mm

Drilling Speed (RPM) Diameter Drilling Speed (RPM) Diameter 1200-1500 Ø 1.9 900-1200 Ø 2.0 700-900 Ø 2.8 15-25 Ø 3.3

Ø

3.3mm

Drill sequences recommended by Edison Medical can not replace the judgment and professional experience of the surgeon.

(12)

Kit Material: High Medical Plasic Grade

Very High Quality Silicone Inserts

Made in Europe

FULL BASIC SURGICAL KIT

Surgical Kit Use and Maintenance Manual

(13)

13

IMPLANTS CATALOG

The Kit Contains:

1 x Ratchet Wrench 6.35mm Hex

1 x Ratchet Adapter: Hex 6.35mm To Square 4.0mm 1 x Gingiva Height Meassure Tool

1 x Short Screwdriver Latch Type 1.25mm 1 x Long Screwdriver Latch Type 1.25mm 1 x Short Implant Driver Latch Type 2.42mm 1 x Long Implant Driver Latch Type 2.42mm 1 x Short Screwdriver Ratchet Key 1.25mm 1 x Long Screwdriver Ratchet Key 1.25mm 1 x Short Implant Driver Ratchet Key 2.42mm 1 x Long Implant Driver Ratchet Key 2.42mm 1 x Hand Wrench Adapter

2 x Long Parallel Pin 2 x Short Parallel Pin 1 x Drill Extender 1 x Marking Drill

1 x Twisted Drill External Irrigation 2mm (Pilot) 1 x Twisted Drill External Irrigation 2.8mm 1 x Twisted Drill External Irrigation 3.2mm 1 x Twisted Drill External Irrigation 3.65mm 1 x Twisted Drill External Irrigation 4.20mm 1 x Twisted Drill External Irrigation 5.20mm 1 x Countersink RP

(14)

Pointer

Implant Detector

Omplant

Driver System

Bibo

OraLight

USEFUL TOOLS

Degranulation Kit

Post Extraction

(15)

15

IMPLANTS CATALOG

Sinus Lift Kit with Stoppers

Safe, Fast & Easy

Bone Compression Kit

The Bone Compression kit improves the treatment in sinus lifting and soft bone compression.

Bio Materials

(16)

PO Box 616, Zikhron Ya’akov, 3090000, Israel Tel: +972.74.702.2771 Fax: +972.77.436.2511 Toll free: 1.888.366.3088 [email protected] www.edisonmed.com

Date: 01/26/15

References

Related documents

and Degradation. More recently, the acronym „REDD+‟ has emerged which stands for avoided deforestation and degradation activities as well as forest restoration, rehabilitation,

As some misapprehension may exist in regard to the publication of papers by the association, it may here be said that all papers engaged for the General Meeting of the American

Although funds are spent each year for this program that aims to improve child nutrition, as FV consumption is low and childhood obesity rates are high, there is limited assessment

This document may contain summarised information or information that has not been audited, as well as information relative to solvency produced with criteria that are still subject

From an employment tax audit perspective, this large pool of “potential employees” presents an opportunity for the IRS and state unemployment taxing authorities to impose penal-

12 Sudden load switching – response of voltage, current and frequency of the grid independent plant using conventional and MMCC based ESS. load switching– operation under

The Mediation Center usually communicates with the parent, advocate and appropriate Department of Education representative (a supervisor from the affiliated

Dari hasil dalam penelitian ini dapat diketahui bahwa variabel independent perputaran piutang mempunyai pengaruh signifikan terhadap likuiditas pada PT Ultrajaya Milk