• No results found

Installation and Setup Guide EMC DATA DOMAIN DD610 STORAGE SYSTEM

N/A
N/A
Protected

Academic year: 2021

Share "Installation and Setup Guide EMC DATA DOMAIN DD610 STORAGE SYSTEM"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

All plug-in modules and blank plates are part of the fire enclosure and must be removed only when a replacement can be added immediately. The system must not be run without all parts in place.

4 A controller must be operated only from a power supply input voltage range of 100–240 VAC, 50–60 Hz.

4 Each component is intended to operate with two working power supplies installed. 4 Provide a suitable power source with electrical

overload protection.

4 A safe electrical earth connection must be pro-vided to the power cord. Check the grounding of the power sources before applying power. 4 The plug on each power supply cord is used as the main disconnect device. Ensure that the socket outlets are located near the equipment and are easily accessible.

4 Permanently unplug the unit if you think it is damaged in any way and before moving it. If the unit is powered by multiple sources, discon-nect all supplied power for complete isolation. 4 The power connections must always be

disconnected prior to removal or replacement of a power supply module from any of the components in the system.

4 A faulty power supply module must be replaced within 24 hours.

4 Do not lift system components by yourself. A controller weighs up to 57 lbs (25.8 kg). 4 To comply with applicable safety, emission,

and thermal requirements, covers must not be removed and all bays must be fitted with plug-in modules.

4 Load the rack beginning at the bottom to prevent the rack from becoming top-heavy.

4 Do not extend components on rails until you have loaded at least three or more similarly weighted items in the rack, or unless the rack is bolted to the floor or overhead structure to prevent tipping.

Caution: If the system is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Caution: The RJ-45 sockets on the motherboard/PCI

cards are for Ethernet connection only and must not be connected to a telecommunications network.

ESD PRECAUTIONS

Data Domain recommends that you fit and check a suitable antistatic wrist or ankle strap and observe all conventional ESD precautions when handling plug-in modules and components.

Safety

1. Unpack the Data Domain system.

A system consists of a DD610 controller and up to 3.5 TB of raw storage with seven 500 GB internal disk drives or up to 6 TB of raw storage with twelve 500 GB internal disk drives. The system uses RAID 6.

4 Open the packing box for the controller.

4 Remove the accessories and rack mount kit for all system components. 2. Install the appropriate rack mounting hardware for the controller into a

19-inch, four-post rack. Ensure that the rack is securely anchored to prevent tipping. Load the rack or cabinet beginning at the bottom to prevent the rack from becoming top-heavy. Be sure to plan appropriate vertical space to accommodate the 2U controller.

See the instructions included with the slide rails. 3. Install the controller in the rack in a horizontal position.

4 Remove the controller from the shipping box. 4 Remove the bezel from the shipping package.

4 Install the controller on the tray rails and slide it into the rack. Be sure one person is at each side of the controller to guide it into the rail ends. 4 Secure the controller in the rack with the thumb screws.

4. Connect an administrative console. Attach a serial console to the controller’s serial port, or use a monitor (VGA port) and keyboard (keyboard/purple icon), or use a KVM. USB is not supported as a KVM connection. See Figure 1.

After physically connecting the Null Modem Serial cable to the 9-pin serial port on the Data Domain system and to the serial port on the client, set

communication parameters of the client (HyperTerminal, PuTTY, etc) as followss:

Baud rate: 9600 Stop Bits: 1

Bits: 8 Flow Control: None

Parity: None Terminal Emulation: VT-100 5. Enable data transfer connectivity. Repeat for each connection.

4 Ethernet connection: If using 1 Gb copper Ethernet, attach a Cat 5e or Cat 6 copper Ethernet cable to an RJ45 Ethernet network port (start with eth0 and go up) on the controller and attach the other end to an Ethernet switch or to an Ethernet port on your server. If using 1 Gb fiber Ethernet, use multimode fiber cables with LC connectors. See Figure 1.

4 Fibre Channel connection: If the system has the optional VTL card, attach a Fibre Channel fiber optical cable (LC connector) to a VTL HBA port on the controller, and attach the other end (LC connector) to a Fibre Channel switch or to a Fibre Channel port on your server. See Figure 1 for PCI card locations for the VTL HBAs.

6. Provide redundant power to the system.

Connect power cables to both receptacles. See Figure 1. 7. Turn the system on.

4 When the Alert/ID LED turns blue, press the power button. See Figure 2. 4 Attach the bezel.

8. Collect the information needed for installation. Enter the information in Section 2 on the other side of this sheet.

Install Hardware

1

The steps for a complete installation and configuration are: 1. Install Hardware

2. Define the Data Domain system information for your site 3. Perform initial system configuration

4. Configure the system for data access 5. Configure optional software

6. Perform optional additional system configuration

Installation and Setup Steps

1 5 4 3 2 6

Installation and Setup Guide

(2)

Data Domain DD610 Storage System

FIGURE 1:

REAR PANEL AND INPUT/OUTPUT CONNECTIVITY

Slot 3

PCI-e x8 (x16 conn) PCI-e x8Slot 2 PCI-e x8Slot 1 1 Gb Ethernet (optional) copper or fiber VTL (optional) or 1 Gb Ethernet copper or fiber NVRAM

FIGURE 2:

FRONT PANEL AND DISK LOCATIONS

The DD610 has either seven or twelve replaceable 500 GB disk drives, depending on configuration. Disk drive carriers are numbered left to right and top to bottom, as shown in the illustration. Unused drive slots contain blank carriers.

Hot-swap disks

Physical location: Logical numbering:

Front Operator Panel LEDs

LED Status

Power Steady Green: System power is on Off: System power is off Alert/ID Steady Blue: No alert

Blinking Amber: Alert

Blinking Blue: ID button has been pressed eth0 Activity eth0 Present eth 1 Activity eth 1 Present 1 2 3 4 5 6 7 8 9 10 11 12 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.101.111.12

DD610 with 7 Disk Drives

DD610 with 12 Disk Drives

Post Display LEDs

LED Status Number Error code. LED is unlit Normal.

Front Operator Panel Buttons

Push Button Definition

Power Press Power button to turn on system power when the Alert/ID LED is blue. If the blue LED is not lit within one minute after AC power is applied to the power supplies, please contact Support (see contact information at the end of this document).

Never shut down the system by pressing the Power button.

Enclosure ID Press the Enclosure ID buttonto light a blue LED in the front and rear to ID the chassis in a rack.

(3)

EMC DATA DOMAIN DD610 INSTALLATION AND SETUP GUIDE | SIDE 1

NOTE: The system might not be usable for up to three hours if the NVRAM batteries

are discharged. Refer to the NVRAM Battery Charging Instructions for more information.

Log into the system with the user name of sysadmin. The password is the system’s serial number. A Configuration Wizard is provided. There are six sections to the configuration: Licenses, Network, File System, System, CIFS, and NFS.

Complete each of the six sections.

USING THE CLI CONFIGURATION WIZARD

At the first login, the configuration wizard starts. The list entries in the utility can be separated by a comma, a space, or both.

4 At each prompt, enter a value, OR

4 Enter a question mark (?) for more details, OR 4 Press Enter to accept the value displayed in braces.

The Configuration Wizard guides you through the configuration steps, one section at a time. Follow the Configuration Wizard instructions for entering appropriate values.

At the end of each configuration section, you can choose to: 4 Save – Save the displayed configuration.

4 Cancel – Delete all new values and go to the next section.

4 Retry – Restart the input entry at the beginning of the current section. The value entered previously appears as the default value at each prompt.

Perform Initial System Configuration

3

SYSTEM SETUP WORKSHEET

An installation requires information unique to your site. Before starting the installation, provide values for the system information listed below. 1. A fully qualified host name for the system:

2. The DNS domain name:

3. Enter the Ethernet connectivity information in Table 1 below. 4. A routing gateway IP address (if no DHCP):

5. DNS server IP addresses (if no DHCP) :

Primary Secondary Tertiary

6. Select the CIFS authentication method:

Workgroup Active Directory Workgroup name: Realm name:

WINS servers: WINS servers: Backup user

name: Domain admin name: Password: Password:

7. Backup servers (or * for all): 8. Administrator’s password:

9. Host name from which to administer the system:

10. Administrator’s email address (or admin group alias):

11. (Optional) Description of the system’s physical location:

12. Mail server (SMTP) host name: 13. Time zone name (default is US/Pacific):

14. License Code(s) - Refer to License Code document(s) provided in the accessory kit. License characters, including dashes, are entered for each licensed feature; for example ABCD-ABCD-ABCD-ABCD.

15. System Controller ID from the License Code document. Use this ID to obtain the unique WWPN for this controller using the WWPN tool at https://my.datadomain.com/us/en/wwpn.jsp.

Define the Data Domain System Information for Your Site

2

Ethernet Connectivity eth0a eth0b eth3a (optional) eth3b (optional) Enable (circle one) Yes / No Yes / No Yes / No Yes / No

Use DHCP (circle one) Yes / No Yes / No Yes / No Yes / No

IP address (if no DHCP) Netmask (if no DHCP)

(4)

For troubleshooting information see the Data Domain Support web site https://support.emc.com.

Troubleshooting Tips

If you purchased optional software for the Data Domain system such as Replicator or Retention Lock, the licenses are enabled on your Data Domain system prior to shipment. You need to configure them for use. Details

configuring the optional software can be found in the EMC Data Domain Operating System Administration Guide.

Configure Optional Software

5

The Data Domain system provides multiple protocols for data access: NFS, CIFS, and OST (OpenStorage). You need to configure one or more protocols for data access depending on your environment. You also need to configure the clients for accessing the Data Domain system on the protocol of your choice.

NFS

The NFS configuration section in the Perform Initial System Configuration sec-tion sets up the NFS clients to allow access to /backup on the Data Domain system. You also need to set up the NFS clients to allow access to /backup on the Data Domain system. This can be done using the following steps: 4 Create a mount point (directory) such as /dd/rstr01/backup and create an administrative mount point such as /dd/rstr01/ddvar. 4 NFS mount the directories on the new mount points. For example:

mount -F nfs -o hard,intr,vers=3,proto=tcp,rsize=327 68,wsize=32768 rstr01:/backup /dd/rstr01/backup mount -F nfs -o hard,intr,vers=3,proto=tcp,rsize=327 68,wsize=32768 rstr01:/ddvar /dd/rstr01/ddvar

4 Add the following lines to the file /etc/vfstab (the file name may be different depending on your UNIX-based system). The lines mount the directories at every reboot. For example:

system:/backup - /dd/rstr01/backup nfs - yes hard,intr,vers=3,proto=tcp, rsize=32768,wsize=32768 system:/ddvar - /dd/rstr01/ddvar nfs - yes

hard,intr,vers=3,proto=tcp, rsize=32768,wsize=32768

4 To cause backup software to abort when the system is not mounted, create a backup directory within the mounted file system, such as /dd/rstr01/backup/disk1.

CIFS

The CIFS configuration section in the Configuration Wizard sets up the CIFS clients to allow access to /backup on the Data Domain system. You also need to set up the CIFS clients to allow access to /backup on the Data Domain system.

VTL (OPTIONAL LICENSE REQUIRED)

For the VTL software option, see the Data Domain technical note Integrating the Data Domain Appliance VTL with SANs. See the specific Data Domain integra-tion documentaintegra-tion for setting up backup software from other vendors.

OPENSTORAGE (OPTIONAL LICENSE REQUIRED)

For setting up the Data Domain feature, see the EMC Data Domain Boost for OpenStorage Administration Guide.

APPLICATION INTEGRATION

For information about how to integrate the Data Domain system with backup software, see the documentation for the applicable application.

Configure the System for Data Access

4

ADDITIONAL SYSTEM CONFIGURATION

Any system command that accepts a list, such as a list of IP addresses, accepts entries separated by either commas or spaces. See the EMC Data Domain Operating System Command Reference Guide for command details. Give access to additional backup servers:

# nfs add /backup {*|client-list} [options]

Add users to the email list that reports system problems: # alerts add email-list

Add users to the system report email list: # autosupport add email-list Enable FTP or TELNET:

# adminaccess enable {ftp|telnet}

Add remote hosts to use FTP or TELNET: # adminaccess add {ftp|telnet} fqdn-host-list

Add a user:

# user add name [priv {admin|user}] Change a user’s password:

# user change password username

TO SHUT DOWN THE SYSTEM

Important: Never shut down the system by pressing the power button.

Instead, enter: # system poweroff

Perform Optional Additional System Configuration

6

For more information, refer to the documentation at EMC Online Support https://support.emc.com.

(5)

Requirement DD610 Controller Vertical Space In Standard

19”, Four Post Rack

2U. Do not use a two-post rack. See the included rail and installation documentation instructions to install in a rack.

Air Conditioning Use air conditioning that can cope with the maximum BTU/hr thermal rating.

Temperature Controls Use adequate temperature control with a gradient (change) not to exceed 30° C in an hour.

Ventilation and Airflow In a closed or multi-unit rack, ensure that the unit has adequate airflow through the front bezel and back panel and that the ambient air temperature requirements are met. Ensure that the front bezel and back panel clearances are met. If installing in a closed cabinet, ensure that the front and rear doors have at least 65% open area to ensure adequate airflow for cooling. Front Bezel Clearance 1.56 inch (4 cm) of unobstructed clearance.

Back Panel Clearance 5 inches (12.7 cm) of unobstructed clearance.

Power / Grounding Two AC power outlets with an earth ground conductor (safety ground). A safe electrical earth connection must be provided to each power cord. Voltage: 100-120 V~ or 200-240 V~. Frequency: 50 to 60 Hz.

Site Requirements

System Heat Output Power (VA) Weight Rack Mounted Dimensions

Model Watts BTU/hr 100-120 / 200-240 V~ lb / kg WxDxH in (cm)

DD610 with 7 Disk Drives 301 1089 319 49 / 22.2 22 (55.9) 23.6 (59.9) 3.5 (8.9)

DD610 with 12 Disk Drives 329 1235 362 57 / 25.8 22 (55.9) 23.6 (59.9) 3.5 (8.9)

Operating Temperature 50° to 95° F (10° to 35° C) Operating Humidity 20% to 80%, non-condensing Non-operating Temperature -40° to +149° F (-40° to +65° C)

Operating Acoustic Noise Max 7.9 BA, Sound Power at 25° C when all drives seek simultaneously

Specifications

For information about Go to https://support.emc.com

How to configure the system Initial Configuration Guide

New features, enhancements, known issues, and late-breaking news about your Data Domain software release

Release Notes for your software release

How to manage the Data Domain operating system EMC Data Domain Operating System Administration Guide

How to install and use the OpenStorage EMC Data Domain Boost for OpenStorage Administration Guide for your platform How to replace Data Domain hardware components Part Installation Guides

How to use third-party applications Integration Documentation and Compatibility Matrices

(6)

TECHNICAL CONTACTS

To resolve issues with Data Domain products, contact your contracted support provider or visit us online at https://support.emc.com.

CORPORATE CONTACTS

EMC Corporation

Data Protection and Availability Division 761-0009-0004 Rev B

August 20, 2014

Contact Information

Copyright © 2009 - 2014 EMC Corporation. All Rights Reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC, Data Domain, and Global Compression are registered trademarks or trademarks of EMC Corporation in the United States and/or other countries. All other trademarks used herein are the property of their respective owners.

References

Related documents

Lesson 9 Using Mental Math to Subtract 28 Lesson 10 Subtracting 3-Digit Numbers 30 Lesson 12 Subtracting 4-Digit Numbers 32 Lesson 13 Solving Addition and Subtraction Problems

In a client or CIFS server failure, the Continuous Availability (CA) feature allows Windows-based clients to persistently access CIFS shares without the loss of the session

Data may in fact be spread over multiple CIFS hosts DFS used to tie all data sets together into the single CIFS namespace seen by the

From figure, it is observed that conductivity values are lesser for urease immobilized PVA-Bi 2 FeNiO 6 based Nanobio composite film deposited onto gold plate compare

This study aimed to determine the effect of extracts of tubers of purple sweet potato (Ipomoea Batatas L.) on the activity of glutathione peroxidase (GPx)

Each zone must have one primary nameserver that loads the zone contents from a local database, and a number of secondary servers, which load a copy of the data from the primary

"The One Book Course: Internships in the Ivory Tower," Emory University, April 2000; Roosevelt University, Fall 2003 "Socratic Self-Examination: A Roundtable on

Robot controller features: Desirable features to look for in robot controllers include compact size and light weight; fast processing speed; modular expandability, to accommodate