• No results found

Commercial Gas Heat Pump - VRF

N/A
N/A
Protected

Academic year: 2021

Share "Commercial Gas Heat Pump - VRF"

Copied!
32
0
0

Loading.... (view fulltext now)

Full text

(1)

Commercial

Commercial

Commercial

Commercial

Gas Heat Pump

Gas Heat Pump

Gas Heat Pump

Gas Heat Pump -

--

- VRF

VRF

VRF

VRF

SANYO GHP Introduction

SANYO GHP Introduction

SANYO GHP Introduction

SANYO GHP Introduction

(2)

Agenda

1. SANYO GHP History

2. SANYO GHP Range

3. GHP Market Position

4. 2-WAY

5. GHP Power

6. 3-WAY

7. EER/COP

8. Water Heat Exchanger (Chiller)

9. GHP Needs Service

(3)

GHP

=

G

as Engine Driven

H

eat

P

ump Air-conditioner

Introduction

(4)

History of SANYO GHP Development

Increase in electric power demand & oil crisis

Japan Government starts the energy leveling policy.

1980

1985

Development

Apr.1981

Apr.1984

Participated in the national project of Gas Cooling

Technology.

Started joint development of GHP with major gas

companies

Worlds First! Released 15HP GHP in Japan

Apr.1985

Three manufacturers entered into GHP market

1987

Achieved total 1 million HP in Japan

Mar.1999

Jul.2000

JIS Establishment

………

…….…

Apr.2002

Sep.2003

Released New Refrigerant (R407C)

Low NOx mode less than 100ppm

Released Overseas J2 model (8HP

20HP)

2 million HP installed in Japan

Jan.2005

Released Overseas J2 3WAY-type

Production of GHP prototype starts with Tokyo Gas.

Jun.2006

Released Overseas K1-type (8HP~25HP);

achieved a total of 1000 systems in Europe

Apr.2008

Released Overseas M2-type (13HP~25HP);

achieved a total of 2000 systems in Europe

(5)

GHP VRF Overview

3 types of GHP are sold in Europe:

W*-MULTI G Power 2-WAY M2-series

• W*-Multi 2-WAY M2-series

(6)

GHP W-MULTI 2 - WAY

GHP (Gas Heat Pump)

(7)

GHP M2 2-way Range

W 1800

D 1000

H 2248

13

16

20

25

26

29

32

33

36

40

45

50

0

5

10

15

20

25

30

35

40

45

50

HP

Single

Multi

GHP M2 range

120

150

190

240

120+120

120+150

150+150

120+190

150+190

190+190

190+240

240+240

13HP: SGP-EW120M2G2W

16HP: SGP-EW150M2G2W

20HP: SGP-EW190M2G2W

25HP: SGP-EW240M2G2W

(8)

GHP Power with Generator

GHP (Gas Heat Pump)

(9)

ECO G Power Range

1 Model 20HP: SGP-EGW190M2GW

Can be combined to max. 2 units.

(10)

GHP 3 - WAY

GHP (Gas Heat Pump)

(11)

3 WAY MULTI Range

3 different sizes of OU:

16 HP: SGP-EZ150M2G2

20 HP: SGP-EZ190M2G2

25 HP: SGP-EZ240M2G2

(12)

GHP The “Multitalent“

Small size

Medium size

Large size

700

700

700

700

3,000㎡

3,000㎡

3,000㎡

3,000㎡

5,000

5,000

5,000

5,000

10,000㎡

10,000㎡

10,000㎡

10,000㎡

Square measure

Chiller system

HP

HP

HP

HP

chiller

Turbo chiller

W

a

te

r

c

o

o

le

d

t

y

p

e

Absorption chiller

PAC

Split type

VRF

VRF

VRF

VRF

GHP

GHP

GHP

GHP

DX system

RAC

Screw chiller

Water cooled VRF

(13)
(14)

GHP 2-way Features 1

• Natural Gas or LPG (Propane)

• Single phase small power supply

• DX VRF indoors (max 46) or chilled water

• Miller cycle engine

• DC fan motors

• Durable compressors with variable speed

allow “quasi“ inverter operation (~15 – 100%)

• Hot water function for domestic hot water

included as standard

Electric supply 0,85 … 1,54 kW

/ unit only, depending on model

(15)

GHP 2-way Features 2

• Diversity ratio

50-200% (Single OU installation)

50-130% (Multi OU installation)

• 200 m longest pipe run and 1000 m total piping length

• Full heating capacity down to -21

°

C / No defrost cycle

• Silent mode offers a further 2dB(A) reduction

• Part load efficiencies increased by 1.85 primary

4.60

compared to EWP

(16)

GHP 3-WAY W-MULTI

COP improvement up to factor 1,8!

Single OU installation

• Up to 36 indoor units per system

• 145m (equiv. Length) longest pipe run

• Diversity ratio 50-200%

• Full heating capacity down to -21

°

C and cooling down to -10

°

C

• No defrost cycle

• Water Heat Exchangers can not be connected

• No Hot Water Function

(17)
(18)
(19)
(20)
(21)
(22)

GHP Power Consumption

Power

Station

50%loss

Sending loss

Sending loss

Fuel

Condensing

loss

Total loss of energy is 62% (

Average in Europe

)

Primary Energie 1m³ gas

10kWh heating capacity

Electric Energy at customer

site 38% of 10kWh = 3,8kWh

Electric AC with EER = 5,0

produces 5 * 3,8kWh =

19,0kWh cooling capacity

Fuel

Electric

energy

0,353kWh as per 1m³ Gas

GHP with EER = 1,92 produces

1,92 * 10kWh =

19,2kWh total

capacity (14,2 kWh cooling

capacity + 5 kWh hot water)

*

(23)

GHP Design EER

Cooling

SGP-EW190M2G2W

Rated condition:

56 kW cooling capacity

20 kW hot water prod.

38,3 kW gas consumption

1,35 kW electricity cons.

2007/742/EC**:

Gas transport loss 10%

Electric conversion 2,5

EER = 1,23 (no hot w.)

EER = 1,67 (with hot w.)*

Plain calculation

(with electric = gas):

EER = 1,41 (no hot w.)

EER = 1,92 (with hot w.)

* Calculated backwards for

comparison with electric AC:

(24)

GHP Design COP

Heating

SGP-EW190M2G2W

Rated Condition!:

63 kW heating capacity

-- kW hot water

43,0 kW gas consumption

1,01 kW electricity

2007/742/EC:

Gas transport loss 10%

Electric conversion 2,5

COP = 1,26

Plain calculation

(with electric = gas):

COP = 1,43

T < -4

°

C:

COP = 0,74 (2007/742/EC)*

COP = 0,84 (plain)

* Calculated backwards for comparison

with electric AC:

COP = 1,89

Ext. Air HE is

faded out!

(25)
(26)

Sound Level 2

Sound level compared to electrical VRF systems

52,00

54,00

56,00

58,00

60,00

62,00

64,00

66,00

68,00

8H

P

10

HP

12

HP

14

HP

16

HP

18

HP

20

HP

GHP

SANYO ECO-I 3way

Company D

(27)

GHP M1 WHE

•3 Sizes available: 25kW, 50kW, (up to 64kW)* cooling / 30kW, 60kW, (up to 72kW)* heating

•Great to replace chiller and boiler systems

•Integrated into SANYO S-Net

•Up to 170 m distance between GHP and WHE possible

•Mixed operation with DX-units possible

(28)

GHP WHE M1 Mixed in VRF

Water Heat Exchanger in mixed operation.

Can be connected like a “normal“ DX unit.

(29)

Maintenance Of GHP

Oil tank

Coolant

Oil filter

Spark plug

Driving

belt

Neutralizer +

Filter mats

Air filter

Front

Back

Valve clearance

Black colour =

exchange

(30)

Periodic Maintenance

10.000 hours engine operation

A car driving with 50 km/h

average speed

(31)

GHP Service Intervals

All GHP models and sizes have a service interval of 10.000 hours.

Generally the lifetime is calculated for max. 30.000 hours.

If the GHP is used for cooling & heating all year round take care about

operating hours! One year = 8.760 hours. If the project will result in such

a kind of operation the GHP is not suited for this need as it would mean

replacement of the unit after only 3,5 years.

Normally operating hours should not exceed 2.000 – 3.000 hours a

year! It is recommended to use the timer functions for stopping

operation at weekend, holiday, nighttime etc. As GHP basic operation

principle is to keep stable room temperatures by smooth operation (low

rpm.) it is very important to keep in mind this point for economic long

time operation.

(32)

References

Related documents

A closed system will exist if a check valve (without bypass), pressure reducing valve (without bypass), or a water meter (without bypass) is installed in the cold water line

Misapplication – Product installed on a job where the hot water usage is not in line with product’s primary intended function: to supply sufficient potable domestic hot water

Histochemical GUS assay of coytledonary node explants of common bean great northern cultivar ‘Coyne’ after 2 weeks on culture media with 10 mg l -1 G418 selection...

Using the purple primer and PVC cement, cement the disk into the cement, cement the disk into the inside of the nozzle right where the inside of the nozzle right where the reduced

Avis Rent A Car System LLC – Concession &amp; Lease Agreement – for the Non-Exclusive Rental Car Concession and Lease Agreement at the Dayton International Airport – Dept..

Evacuated Tube Collectors Heat Pipe Source: www.kingspansolar.ie Tube- manifold connection Absorber plate Absorber support clip Evacuated glass tube End support

This paper intends to make a case for closer collaboration between oral history archives about accounts of experiences of war on the one hand and transitional justice research on

• Combination of split heat pump system with external and internal unit plus gas condensing boiler • For central heating and domestic hot water • Maximum flow temperature