• No results found

Installation of smart meters

N/A
N/A
Protected

Academic year: 2021

Share "Installation of smart meters"

Copied!
21
0
0

Loading.... (view fulltext now)

Full text

(1)

Installation of smart meters

YOU CAN’T MANAGE WHAT YOU DON'T

MEASURE….

W. EDWARD DEMIN

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(2)
(3)

Monitoring

Options

Product

Criteria

selection

Option 1

Currentcost

Lower cost

Lower cost

Best utilities

Option 2

Ecobox

Option 3

Efergy

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(4)

Monitoring: devices

Main advantage:

discriminate consumption by services

Per

Per

electrical

circuits

Per each

equipment

or appliance

or appliance

(fridge, …)

(5)

Monitoring: Selection of WP6 experiment dwellings

Before installation

1

. Meeting to

RE from de latin “re” ,

it means repetition

1

. Meeting to

the Neighborhood

Representative Committee

(representing the

neighborhoods)

2

. Household survey

3

. Neighbourhood

volunteers

for monitoring

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

it means repetition

NATO from de latin “natus” ,

it means born

Mascot for the Awareness Campaign

for monitoring

4

. Signed Authorization

by homeowners

(6)

Monitoring: Household survey

500 surveys

In a regional level

40 household

survey (of 56)

71% participation

(7)

Results of the questionnaire to households participating in

WP5 to select the ones participating in WP6

SMS 80%

Internet 43%

None 20%

Usage of social and entertainment media by adult members of household

0% 20% 40% 60% 80% 100% Usage of social and

entertainment media by adult members of househol d

None Internet SM S

Household appliances in use

Programmabe controllers 0% High energy class appliances 33% Low energy class appliances 68%

Use of home automation

None 100%

Simple 0%

Sophisticated 0%

Use of energy saving lightning

NO 25%

YES 75%

Heating, cooling and DHW

0% 20% 40% 60% 80% 100% Household appliances in

use

Hig h energy class appli ances Low energy class appli ances

0% 20% 40% 60% 80% 100%

Use of energ y saving lightning NO

YES

Gas natural

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

Heating, cooling and DHW

Stand-alone electric heating 28% Air-conditionaing 73% Electric bolier DHW 20% Gas natural 63% Central heating 0%

0% 20% 40% 60% 80% Heating, cooling and

DH W

Gas natural

Electric bolier DH W

(8)

Monitoring: basic modul

CE Approvals:

ETSI EN 300 220-2 V2.1.1(2006-04), EN 50371 2002, EN 301489-3

v1.4.1 2002-08, EN 60215:1989+A1:1992+A2:1994, IEC

60950-1:2001(1st Edition) and/or EN 60950-1:2001+A11:2004

(9)

Monitoring: NET SMART

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(10)
(11)

Steps: monitoring

Date

Apartament

block

Number of

dwellings

monitorization

July/August

2012

Fontanares

8

Pio XII

7

Total

15

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(12)

Devices installed

EACH DWELLING

1 monitor- interface

A general monitoring of the dwelling

6 DWELLINGs

1 Transmitter

Or more (2)

Monitor per electrical circuits

kitchen appliances, lighting,…)

5 IAMS (INDIVIDUAL APPLIANCE

1 net smart

5 IAMS (INDIVIDUAL APPLIANCE

MONITOR)

Monitor or per each equipment

or appliance (fridge, every light…)

(13)

Manual and

verbal instructions

Personalization

Instructions, more simple

Instructions, more simple

Time clock

Chanels for equipment

or appliance

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(14)

Identification

And contact (email, tel.)

Template for

data collection

Identification

devices and services

(15)

Monitoring PIO XII: install process

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(16)
(17)

Monitoring + audit

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(18)
(19)

Monitoring: input Consumption bills

1. Collecting consumption

bills of the household

monitorized.

2. Analyse utility bills

3. Compare to data of

monitoring

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

(20)

Monitoring: Manage the information

Conection

Download by

Number

Frecuency

USB

VISITE

10

DWELLINGS

Once every

2 months

INTERNET

REMOTE CONTROL

6

DWELLINGS

2 fontanares

2 fontanares

4 PIO XII

(21)

Consumption for month,year:

total, washing machine,

Personalized report

Bulletin on

energy efficiency

total, washing machine,

refrigerator, air

conditioning,…

Evolution energy

consumption in a day,

month,…

Projet financé par le Fonds Européen de Développement Régional - FEDER Project co-financed by European Regional Development Fund - ERDF

Estimated cost

for each equipment

or appliance

References

Related documents

Research of the religious context of Pentecostalism in Costa Rica, which is primarily characterized by the official Catholic Church and the Catholic lay

“Benchmarking of parental control tools for the online protection of children” SIP-Bench II SMART 2009/0047 Tools for PCs 1st cycle best tool: 3,3 worst tool: 2,0 2nd cycle best

Projet co-financé par le Fonds Européen de Développement Régional - FEDER Project co- financed by European Regional Development Fund - ERDF.. 24 January

Projet co-financé par le Fonds Européen de Développement Régional - FEDER Project co- financed by European Regional Development Fund - ERDF.. Context : 13 Habitat launched last year a

Projet co‐financé par le Fonds Européen de Développement Régional ‐ FEDER Project co‐ financed by European Regional Development Fund ‐ ERDF

The decline of seep gas measured in the tents correlates with production decline at Platform Holly and corresponding decrease in reservoir pressure.. The seep tents provide a

files, such operations for accessing and modifying the data in files and for creating and deleting. To perform these primitive file operations correctly and efficiently, typical