1.2 Architecture of the OptiX OSN 2500

...

1-3

1.3 Architecture of the OptiX OSN 1500A

...

1-5

1.4 Architecture of the OptiX OSN 1500B

...

1-5

2 Cabinet

...

2-1

2.1 Types

...

2-1

2.2 Cabinet Configuration

...

2-3

2.2.1 Cabinet Indicators

...

2-3

2.2.2 Power Distribution Unit

...

2-4

2.2.3 Other Configuration

...

2-4

2.3 Technical Parameters

...

2-5

3 Subrack

...

3-1

3.1 Subrack for the OptiX OSN 3500

...

3-1

3.1.1 Structure

...

3-1

3.1.2 Slot Distribution

...

3-3

3.1.3 Boards and the Corresponding Slots

...

3-4

3.1.4 Technical Parameters

...

3-9

3.2 Subrack for the OptiX OSN 2500

...

3-9

3.2.1 Structure

...

3-9

3.2.2 Slot Distribution

...

3-11

3.2.3 Boards and the Corresponding Slots

...

3-13

3.2.4 Technical Parameters

...

3-17

3.3 Subrack for the OptiX OSN 2500 REG

...

3-18

3.4 Subrack for the OptiX OSN 1500A

...

3-19

3.4.1 Structure

...

3-19

3.4.2 Slot Distribution

...

3-19

3.4.3 Boards and the Corresponding Slots

...

3-20

3.4.4 Technical Parameters

...

3-23

3.5 Subrack for the OptiX OSN 1500B

...

3-24

3.5.1 Structure

...

3-24

3.5.2 Slot Distribution

...

3-25

3.5.3 Boards and the Corresponding Slots

...

3-27

3.5.4 Technical Parameters

...

3-31

4 Board Classification and List

...

4-1

(2)

4.1.5 Other Boards

...

4-9

4.2 Board Appearance

...

4-10

5 SDH Boards

...

5-1

5.1 SL64

...

5-1

5.1.1 Functionality

...

5-1

5.1.2 Principle

...

5-2

5.1.3 Front Panel

...

5-4

5.1.4 Parameter Configuration

...

5-5

5.1.5 Version Description

...

5-5

5.1.6 Technical Parameters

...

5-5

5.2 SF16/SL16

...

5-7

5.2.1 Functionality

...

5-7

5.2.2 Principle

...

5-8

5.2.3 Front Panel

...

5-10

5.2.4 Parameter Configuration

...

5-11

5.2.5 Version Description

...

5-11

5.2.6 Technical Parameters

...

5-12

5.3 SL4/SLD4/SLQ4

...

5-15

5.3.1 Functionality

...

5-15

5.3.2 Principle

...

5-16

5.3.3 Front Panel

...

5-17

5.3.4 Parameter Configuration

...

5-18

5.3.5 Version Description

...

5-19

5.3.6 Technical Parameters

...

5-19

5.4 SL1/SLQ1/SLT1

...

5-21

5.4.1 Functionality

...

5-22

5.4.2 Principle

...

5-22

5.4.3 Front Panel

...

5-24

5.4.4 Parameter Configuration

...

5-25

5.4.5 Version Description

...

5-25

5.4.6 Technical Parameters

...

5-26

5.5 R1SLD4/R1SL4/R1SL1/R1SLQ1

...

5-27

5.5.1 Functionality

...

5-28

5.5.2 Principle

...

5-29

5.5.3 Front Panel

...

5-29

5.5.4 Parameter Configuration

...

5-30

5.5.5 Version Description

...

5-31

(3)

5.6.2 Principle

...

5-34

5.6.3 Front Panel

...

5-35

5.6.4 Protection Configuration

...

5-36

5.6.5 Parameter Configuration

...

5-40

5.6.6 Version Description

...

5-40

5.6.7 Technical Parameters

...

5-40

6 PDH Boards

...

6-1

6.1 SPQ4/MU04/TSB8

...

6-1

6.1.2 Functionality

...

6-2

6.1.3 Principle

...

6-2

6.1.4 Front Panel

...

6-4

6.1.5 Protection Configuration

...

6-5

6.1.6 Parameter Configuration

...

6-9

6.1.7 Version Description

...

6-9

6.1.8 Technical Parameters

...

6-9

6.2 PL3/PD3/PL3A/C34S/D34S

...

6-11

6.2.1 Functionality

...

6-11

6.2.2 Principle

...

6-12

6.2.3 Front Panel

...

6-13

6.2.4 Protection Configuration

...

6-15

6.2.5 Parameter Configuration

...

6-20

6.2.6 Version Description

...

6-20

6.2.7 Technical Parameters

...

6-20

6.3 PQ1/PQM/D75S/D12S/D12B

...

6-22

6.3.1 Functionality

...

6-22

6.3.2 Principle

...

6-23

6.3.3 Front Panel

...

6-24

6.3.4 Protection Configuration

...

6-26

6.3.5 Parameter Configuration

...

6-29

6.3.6 Version Description

...

6-29

6.3.7 Technical Parameters

...

6-29

6.4 PD1/PL1/L75S/L12S

...

6-31

6.4.1 Functionality

...

6-31

6.4.2 Principle

...

6-32

6.4.3 Front Panel

...

6-32

(4)

7.1 EGT2/EFT8/EFT4/EFF8/ETF8

...

7-2

7.1.1 Functionality

...

7-3

7.1.2 Principle

...

7-4

7.1.3 Front Panel

...

7-5

7.1.4 Parameter Configuration

...

7-8

7.1.5 Version Description

...

7-8

7.1.6 Technical Parameters

...

7-9

7.2 EGS2/EFS4/EFS0/ETF8/EFF8/ETS8

...

7-11

7.2.1 Functionality

...

7-12

7.2.2 Principle

...

7-14

7.2.3 Front Panel

...

7-15

7.2.4 Protection Configuration

...

7-17

7.2.5 Parameter Configuration

...

7-19

7.2.6 Version Description

...

7-20

7.2.7 Technical Parameters

...

7-21

7.3 EMR0/EGR2

...

7-24

7.3.1 Functionality

...

7-24

7.3.2 Principle

...

7-27

7.3.3 Front Panel

...

7-28

7.3.4 Parameter Configuration

...

7-30

7.3.5 Version Description

...

7-32

7.3.6 Technical Parameters

...

7-33

7.4 ADL4/ADQ1

...

7-34

7.4.1 Functionality

...

7-34

7.4.2 Principle

...

7-35

7.4.3 Front Panel

...

7-36

7.4.4 Protection Configuration

...

7-38

7.4.5 Parameter Configuration

...

7-38

7.4.6 Version Description

...

7-39

7.4.7 Technical Parameters

...

7-39

7.5 IDL4/IDQ1

...

7-40

7.5.1 Functionality

...

7-40

7.5.2 Principle

...

7-41

7.5.3 Front Panel

...

7-41

7.5.4 Protection Configuration

...

7-43

7.5.5 Parameter Configuration

...

7-43

7.5.6 Version Description

...

7-44

(5)

7.6.2 Principle

...

7-46

7.6.3 Front Panel

...

7-48

7.6.4 Parameter Configuration

...

7-49

7.6.5 Version Description

...

7-49

7.6.6 Technical Parameters

...

7-49

8 Cross-Connect and System Control Boards

...

8-1

8.1 GXCS/EXCS/UXCS/XCE

...

8-2

8.1.1 Functionality

...

8-2

8.1.2 Principle

...

8-3

8.1.3 Front Panel

...

8-4

8.1.4 Protection Configuration

...

8-6

8.1.5 Parameter Configuration

...

8-7

8.1.6 Version Description

...

8-7

8.2 CXL1/CXL4/CXL16

...

8-9

8.2.1 Functionality

...

8-9

8.2.2 Principle

...

8-10

8.2.3 Front Panel

...

8-11

8.2.4 Protection Configuration

...

8-13

8.2.5 Parameter Configuration

...

8-13

8.2.6 Version Description

...

8-14

8.2.7 Technical Parameters

...

8-14

8.3 SCC/GSCC

...

8-16

8.3.1 Functionality

...

8-16

8.3.2 Principle

...

8-17

8.3.3 Front Panel

...

8-18

8.3.4 Version Description

...

8-21

8.3.5 Technical Parameters

...

8-21

8.4 CRG

...

8-22

8.4.1 Functionality

...

8-22

8.4.2 Principle

...

8-23

8.4.3 Front Panel

...

8-24

8.4.4 Version Description...

8 -26

8.4.5 Technical Parameters ...

8-26

9 Other Boards

...

9-1

9.1 LWX

...

9-1

(6)

9.1.5 Technical Parameters

...

9-5

9.2 MR2A/MR2B/MR2C

...

9-7

9.2.1 Functionality

...

9-7

9.2.2 Principle

...

9-8

9.2.3 Front Panel

...

9-9

9.2.4 Version Description

...

9-11

9.2.5 Technical Parameters

...

9-11

9.3 BA2/BPA

...

9-12

9.3.1 Functionality

...

9-12

9.3.2 Application

...

9-12

9.3.3 Principle

...

9-13

9.3.4 Front Panel

...

9-14

9.3.5 Version Description

...

9-15

9.3.6 Technical Parameters

...

9-15

9.4 COA

...

9-16

9.4.1 Functionality

...

9-17

9.4.2 Application

...

9-17

9.4.3 Principle

...

9-18

9.4.4 Front Panel

...

9-19

9.4.5 Installation

...

9-22

9.4.6 Version Description.

...

9-23

9.4.7 Technical Parameters

...

9-23

9.5 DCU

...

9-25

9.5.1 Functionality

...

9-25

9.5.2 Application

...

9-25

9.5.3 Principle

...

9-26

9.5.4 Front Panel

...

9-26

9.5.5 Version Description

...

9-28

9.5.6 Technical Parameters

...

9-28

9.6 AUX/EOW/SAP/SEI

...

9-30

9.6.1 Functionality

...

9-30

9.6.2 Principle Of AUX

...

9-33

9.6.3 Principle of EOW

...

9-33

9.6.4 Principle of SAP

...

9-34

9.6.5 Principle of SEI

...

9-35

9.6.6 Front Panel

...

9-36

9.6.7 Alarm Concatenation

...

9-44

(7)

9.7.1 Functionality

...

9-48

9.7.2 Principle of N1PIU and Q1PIU

...

9-48

9.7.3 Principle of R1PIU

...

9-49

9.7.4 Principle of R2PIU

...

9-49

9.7.5 Front Pane

...

9-50

9.7.6 Version Description

...

9-54

9.7.7 Technical Parameters

...

9-54

9.8 UPM

...

9-55

9.8.1 Functionality

...

9-56

9.8.2 Principle

...

9-56

9.8.3 Front Panel

...

9-57

9.8.4 Precautions

...

9-58

9.8.5 Technical Parameters

...

9-58

9.9 FAN

...

9-59

9.9.1 Functionality

...

9-60

9.9.2 Principle of N1FAN

...

9-60

9.9.3 Principle of R1FAN

...

9-61

9.9.4 Front Panel

...

9-61

9.9.5 Version Description

...

9-62

9.9.6 Technical Parameters

...

9-62

10 Cables

...

10-1

10.1 Fiber Jumper

...

10-1

10.1.1 Classification

...

10-1

10.1.2 Connector

...

10-2

10.2 Power Cable and Grounding Cable

...

10-5

10.2.1 Cabinet -48 V/BGND/PGND Power cable

...

10-5

10.2.2 Cabinet Door Grounding Cable

...

10-7

10.2.3 Subrack Power Cable

...

10-8

10.2.4 Equipment -48 V/-60 V Power Cable/PGND Grounding Cable

...

10-9

10.2.5 HUB/COA Power Cable

...

10-11

10.2.6 UPM Power Cable

...

10-12

10.3 Alarm Cable

...

10-14

10.3.1 Cabinet Indicator Cable

...

10-14

10.3.2 Indicator/ Alarm Concatenating Cables between OSN

(8)

10.4.3 RS-232/422 Serial Port Cable

...

10-24

10.4.4 Orderwire Telephone Wire

...

10-25

10.4.5 COA Concatenating Cable

...

10-26

10.4.6 Straight Through Cable

...

10-27

10.4.7 Crossover Cable

...

10-29

10.5 Signal Cable

...

10-31

10.5.1 75ohm 8xE1 Cable

...

10-31

10.5.2 75ohm 16xE1 Cable

...

10-33

10.5.3 120ohm 8xE1 Cable

...

10-35

10.5.4 120ohm 16xE1 Cable

...

10-37

10.5.5 E3/DS3/STM-1 Cable

...

10-39

10.5.6 Extended Subrack Service Connection Cable

...

10-41

10.6 Clock Cable

...

10-43

10.6.1 Clock Cable

...

10-43

10.6.2 1/2-Channel Clock Transfer Cable

...

10-45

A Indicator Description for Equipment and Board

...

A-1

A.1 Cabinet Indicator Description

...

A-1

A.2 Board Indicator Description

...

A-2

B Board Version Description

...

B-1

B.1 Board Version List

...

B-1

B.2 Version Description

...

B-4

B.2.1 Optical Line Interface Board

...

B-4

B.2.2 Ethernet Processing Board

...

B-5

B.2.3 Cross-Connect and SCC boards

...

B-7

B.2.4 Other Boards

...

B-8

C Power Consumption and Weight

...

C-1

D Abbreviations and Acronyms

...

D-1

Index ...

(9)

HUAWEI

OptiX OSN 3500/2500/1500

Intelligent Optical Transmission System

Hardware Description Manual

(10)

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission

System

Hardware Description Manual

Manual Version T2-042590-20051020-C-1.31

Product Version V100R003

BOM 31250390

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.

Huawei Technologies Co., Ltd.

Address: Administration Building, Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, P. R. China Postal Code: 518129

Website: http://www.huawei.com Email: [email protected]

(11)

Copyright © 2005 Huawei Technologies Co., Ltd. All Rights Reserved

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks

, HUAWEI, C&C08, EAST8000, HONET, , ViewPoint, INtess, ETS, DMC,

TELLIN, InfoLink, Netkey, Quidway, SYNLOCK, Radium, M900/M1800,

TELESIGHT, Quidview, Musa, Airbridge, Tellwin, Inmedia, VRP, DOPRA, iTELLIN, HUAWEIOptiX, C&C08 iNET, NETENGINE, OptiX, iSite, U-SYS, iMUSE, OpenEye, Lansway, SmartAX, infoX, TopEng are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this manual are the property of their respective holders.

Notice

The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.

(12)

Summary of Updates

This section provides the update history of this manual and introduces the updates of contents.

Update History

Manual Version Notes

T2-042587-20040215-C-1.10 Initial field trial release T2-042586-20040501-C-1.11 The manual style is modified.

T2-042552-20041026-C-1.20 Descriptions of the EGT2, EMR0, EFF8, ADL4, ADQ1, MST4, LMST4, UXCS, XCE, LWX, and MR2A are added. T2-042552-20050228-C-1.21 Descriptions of the ETS8, SF64, and COA are added. T2-042590-20050820-C-1.30 1. The hardware description manuals of the OptiX OSN

3500, OptiX OSN 2500 and OptiX OSN 1500 are combined into one.

2. The descriptions of the CRG, PIU, PL3A, R1SL4, R1SLD4, R1SL1, R1SLQ1and MST4 boards are added. 3. The manual is reorganized. The boards are described in several chapters.

T2-042590-20051020-C-1.31 Fix several bugs in the manual of the previous version. Delete

the description of the N1SL64 and N1SF64 board. Update the weight of the ETSI cabinet and the power consumption of the boards.

Updates of Contents

Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Updates in Manual Version 1.31

Fix several bugs in the manual of the previous version. Delete the description of the N1SL64 and N1SF64 board.

(13)

OptiX OSN 1500 are combined into one. The manual is reorganized. Chapter 4 of the original manual is divided into 6 chapters (chapter 4 to chapter 9).

Chapter 1 Equipment Architecture

Introduces the structure of the OptiX OSN 3500, OptiX OSN 2500, OptiX OSN 1500A and OptiX OSN 1500B respectively.

Chapter 2 Cabinet

Introduces the cabinet used by OptiX OSN series products. Chapter 3 Subrack

Introduces the subrack structure and board configuration of the OptiX OSN 3500, OptiX OSN 2500, OptiX OSN 2500REG, OptiX OSN 1500A and OptiX OSN 1500B. Chapter 4 Board Classification and List

This is a new chapter, which introduces board classification and gives a list of boards. The subsequent chapters (chapter 5–chapter 9) give detailed descriptions.

Chapter 5 SDH Boards

The descriptions of the R1SL4, R1SLD4, R1SL1 and R1SLQ1 are added. Chapter 6 PDH Boards

The descriptions of the PL3A is added. Chapter 7 Data Processing Boards

The descriptions of the N3EFS0, N3EGS2 and N3EFS4 are added. Chapter 8 Cross-connect and SCC Boards

The descriptions of the CRG is added. Chapter 9 Other Boards

The descriptions of the PIU and FANA are added. Appendix B Board Version Description

It is newly added, introducing version characteristics of all boards of the OptiX OSN series products and their differences.

Updates in Manual Version 1.21

Chapter 3 Subrack

The boards ETS8, SF64 and COA are added in the table 3-2. Chapter 4 Boards

The detailed descriptions of following boards are added: ETS8, SF64 and COA. The detailed descriptions of following boards are modified and improved: EGS2/EFS0/EFS4.

Chapter 5 Cables

Classification and descriptions of cables are improved.

Updates in Manual Version 1.20

(14)

Chapter 4 Boards

The detailed descriptions of following boards are added: EMR0, EFF8, ADL4, ADQ1, MR2A, LWX, EGT2, XCE and UXCS.

(15)

Contents

1 Equipment Architecture

1-1

1.1 Architecture of the OptiX OSN 3500 1-1

1.2 Architecture of the OptiX OSN 2500 1-3

1.3 Architecture of the OptiX OSN 1500A 1-5

1.4 Architecture of the OptiX OSN 1500B 1-5

2 Cabinet

2-1

2.1 Types 2-1

2.2 Cabinet Configuration 2-3

2.2.1 Cabinet Indicators 2-3

2.2.2 Power Distribution Unit 2-4

2.2.3 Other Configuration 2-4

2.3 Technical Parameters 2-5

3 Subrack

3-1

3.1 Subrack for the OptiX OSN 3500 3-1

3.1.1 Structure 3-1

3.1.2 Slot Distribution 3-3

3.1.3 Boards and the Corresponding Slots 3-4

3.1.4 Technical Parameters 3-9

3.2 Subrack for the OptiX OSN 2500 3-9

3.2.1 Structure 3-9

3.2.2 Slot Distribution 3-11

3.2.3 Boards and the Corresponding Slots 3-13

3.2.4 Technical Parameters 3-17

(16)

3.4 Subrack for the OptiX OSN 1500A 3-19

3.4.1 Structure 3-19

3.4.2 Slot Distribution 3-19

3.4.3 Boards and the Corresponding Slots 3-20

3.4.4 Technical Parameters 3-23

3.5 Subrack for the OptiX OSN 1500B 3-24

3.5.1 Structure 3-24

3.5.2 Slot Distribution 3-25

3.5.3 Boards and the Corresponding Slots 3-27

3.5.4 Technical Parameters 3-31

4 Board Classification and List

4-1

4.1 Board Classification 4-1

4.1.1 SDH Boards 4-1

4.1.2 PDH Boards 4-3

4.1.3 Data Processing Boards 4-4

4.1.4 Cross-Connect and SCC Boards 4-6

4.1.5 Other Boards 4-9 4.2 Board Appearance 4-10

5 SDH Boards

5-1

5.1 SL64 5-1 5.1.1 Functionality 5-1 5.1.2 Principle 5-2 5.1.3 Front Panel 5-4 5.1.4 Parameter Configuration 5-5 5.1.5 Version Description 5-5 5.1.6 Technical Parameters 5-5 5.2 SF16/SL16 5-7 5.2.1 Functionality 5-7 5.2.2 Principle 5-8 5.2.3 Front Panel 5-10 5.2.4 Parameter Configuration 5-11 5.2.5 Version Description 5-11 5.2.6 Technical Parameters 5-12 5.3 SL4/SLD4/SLQ4 5-15 5.3.1 Functionality 5-15 5.3.2 Principle 5-16

(17)

5.3.3 Front Panel 5-17 5.3.4 Parameter Configuration 5-18 5.3.5 Version Description 5-19 5.3.6 Technical Parameters 5-19 5.4 SL1/SLQ1/SLT1 5-21 5.4.1 Functionality 5-22 5.4.2 Principle 5-22 5.4.3 Front Panel 5-24 5.4.4 Parameter Configuration 5-25 5.4.5 Version Description 5-25 5.4.6 Technical Parameters 5-26 5.5 R1SLD4/R1SL4/R1SL1/R1SLQ1 5-27 5.5.1 Functionality 5-28 5.5.2 Principle 5-29 5.5.3 Front Panel 5-29 5.5.4 Parameter Configuration 5-30 5.5.5 Version Description 5-31 5.5.6 Technical Parameters 5-31 5.6 SEP1/EU08/OU08/TSB8 5-32 5.6.1 Functionality 5-33 5.6.2 Principle 5-34 5.6.3 Front Panel 5-35 5.6.4 Protection Configuration 5-36 5.6.5 Parameter Configuration 5-40 5.6.6 Version Description 5-40 5.6.7 Technical Parameters 5-40

6 PDH Boards

6-1

6.1 SPQ4/MU04/TSB8 6-1 6.1.2 Functionality 6-2 6.1.3 Principle 6-2 6.1.4 Front Panel 6-4 6.1.5 Protection Configuration 6-5 6.1.6 Parameter Configuration 6-9 6.1.7 Version Description 6-9 6.1.8 Technical Parameters 6-9 6.2 PL3/PD3/PL3A/C34S/D34S 6-11

(18)

6.2.1 Functionality 6-11 6.2.2 Principle 6-12 6.2.3 Front Panel 6-13 6.2.4 Protection Configuration 6-15 6.2.5 Parameter Configuration 6-20 6.2.6 Version Description 6-20 6.2.7 Technical Parameters 6-20 6.3 PQ1/PQM/D75S/D12S/D12B 6-22 6.3.1 Functionality 6-22 6.3.2 Principle 6-23 6.3.3 Front Panel 6-24 6.3.4 Protection Configuration 6-26 6.3.5 Parameter Configuration 6-29 6.3.6 Version Description 6-29 6.3.7 Technical Parameters 6-29 6.4 PD1/PL1/L75S/L12S 6-31 6.4.1 Functionality 6-31 6.4.2 Principle 6-32 6.4.3 Front Panel 6-32 6.4.4 Protection Configuration 6-33 6.4.5 Parameter Configuration 6-35 6.4.6 Version Description 6-35 6.4.7 Technical Parameters 6-35

7 Data Processing Boards

7-1

7.1 EGT2/EFT8/EFT4/EFF8/ETF8 7-2 7.1.1 Functionality 7-3 7.1.2 Principle 7-4 7.1.3 Front Panel 7-5 7.1.4 Parameter Configuration 7-8 7.1.5 Version Description 7-8 7.1.6 Technical Parameters 7-9 7.2 EGS2/EFS4/EFS0/ETF8/EFF8/ETS8 7-11 7.2.1 Functionality 7-12 7.2.2 Principle 7-14 7.2.3 Front Panel 7-15 7.2.4 Protection Configuration 7-17

(19)

7.2.5 Parameter Configuration 7-19 7.2.6 Version Description 7-20 7.2.7 Technical Parameters 7-21 7.3 EMR0/EGR2 7-24 7.3.1 Functionality 7-24 7.3.2 Principle 7-27 7.3.3 Front Panel 7-28 7.3.4 Parameter Configuration 7-30 7.3.5 Version Description 7-32 7.3.6 Technical Parameters 7-33 7.4 ADL4/ADQ1 7-34 7.4.1 Functionality 7-34 7.4.2 Principle 7-35 7.4.3 Front Panel 7-36 7.4.4 Protection Configuration 7-38 7.4.5 Parameter Configuration 7-38 7.4.6 Version Description 7-39 7.4.7 Technical Parameters 7-39 7.5 IDL4/IDQ1 7-40 7.5.1 Functionality 7-40 7.5.2 Principle 7-41 7.5.3 Front Panel 7-41 7.5.4 Protection Configuration 7-43 7.5.5 Parameter Configuration 7-43 7.5.6 Version Description 7-44 7.5.7 Technical Parameters 7-44 7.6 MST4 7-45 7.6.1 Functionality 7-45 7.6.2 Principle 7-46 7.6.3 Front Panel 7-48 7.6.4 Parameter Configuration 7-49 7.6.5 Version Description 7-49 7.6.6 Technical Parameters 7-49

8 Cross-Connect and System Control Boards

8-1

8.1 GXCS/EXCS/UXCS/XCE 8-2

(20)

8.1.2 Principle 8-3 8.1.3 Front Panel 8-4 8.1.4 Protection Configuration 8-6 8.1.5 Parameter Configuration 8-7 8.1.6 Version Description 8-7 8.2 CXL1/CXL4/CXL16 8-9 8.2.1 Functionality 8-9 8.2.2 Principle 8-10 8.2.3 Front Panel 8-11 8.2.4 Protection Configuration 8-13 8.2.5 Parameter Configuration 8-13 8.2.6 Version Description 8-14 8.2.7 Technical Parameters 8-14 8.3 SCC/GSCC 8-16 8.3.1 Functionality 8-16 8.3.2 Principle 8-17 8.3.3 Front Panel 8-18 8.3.4 Version Description 8-21 8.3.5 Technical Parameters 8-21 8.4 CRG 8-22 8.4.1 Functionality 8-22 8.4.2 Principle 8-23 8.4.3 Front Panel 8-24 8.4.4 Version Description 8-26 8.4.5 Technical Parameters 8-26

9 Other Boards

9-1

9.1 LWX 9-1 9.1.1 Functionality 9-1 9.1.2 Principle 9-2 9.1.3 Front Panel 9-3 9.1.4 Version Description 9-5 9.1.5 Technical Parameters 9-5 9.2 MR2A/MR2B/MR2C 9-7 9.2.1 Functionality 9-7 9.2.2 Principle 9-8 9.2.3 Front Panel 9-9

(21)

9.2.4 Version Description 9-11 9.2.5 Technical Parameters 9-11 9.3 BA2/BPA 9-12 9.3.1 Functionality 9-12 9.3.2 Application 9-12 9.3.3 Principle 9-13 9.3.4 Front Panel 9-14 9.3.5 Version Description 9-15 9.3.6 Technical Parameters 9-15 9.4 COA 9-16 9.4.1 Functionality 9-17 9.4.2 Application 9-17 9.4.3 Principle 9-18 9.4.4 Front Panel 9-19 9.4.5 Installation 9-22 9.4.6 Version Description. 9-23 9.4.7 Technical Parameters 9-23 9.5 DCU 9-25 9.5.1 Functionality 9-25 9.5.2 Application 9-25 9.5.3 Principle 9-26 9.5.4 Front Panel 9-26 9.5.5 Version Description 9-28 9.5.6 Technical Parameters 9-28 9.6 AUX/EOW/SAP/SEI 9-30 9.6.1 Functionality 9-30 9.6.2 Principle Of AUX 9-33 9.6.3 Principle of EOW 9-33 9.6.4 Principle of SAP 9-34 9.6.5 Principle of SEI 9-35 9.6.6 Front Panel 9-36 9.6.7 Alarm Concatenation 9-44

9.6.8 DIP Switch and Jumper 9-46

9.6.9 Version Description 9-46

9.6.10 Technical Parameters 9-47

(22)

9.7.2 Principle of N1PIU and Q1PIU 9-48 9.7.3 Principle of R1PIU 9-49 9.7.4 Principle of R2PIU 9-49 9.7.5 Front Pane 9-50 9.7.6 Version Description 9-54 9.7.7 Technical Parameters 9-54 9.8 UPM 9-55 9.8.1 Functionality 9-56 9.8.2 Principle 9-56 9.8.3 Front Panel 9-57 9.8.4 Precautions 9-58 9.8.5 Technical Parameters 9-58 9.9 FAN 9-59 9.9.1 Functionality 9-60 9.9.2 Principle of N1FAN 9-60 9.9.3 Principle of R1FAN 9-61 9.9.4 Front Panel 9-61 9.9.5 Version Description 9-62 9.9.6 Technical Parameters 9-62

10 Cables

10-1

10.1 Fiber Jumper 10-1 10.1.1 Classification 10-1 10.1.2 Connector 10-2

10.2 Power Cable and Grounding Cable 10-5

10.2.1 Cabinet –48 V/BGND/PGND Power cable 10-5

10.2.2 Cabinet Door Grounding Cable 10-7

10.2.3 Subrack Power Cable 10-8

10.2.4 Equipment –48 V/–60 V Power Cable/PGND Grounding Cable 10-9

10.2.5 HUB/COA Power Cable 10-11

10.2.6 UPM Power Cable 10-12

10.3 Alarm Cable 10-14

10.3.1 Cabinet Indicator Cable 10-14

10.3.2 Indicator/Alarm Concatenating Cables between OSN Subracks 10-15

10.3.3 Alarm Concatenating Cable between OSN Subrack and Other Subrack 10-17

10.3.4 Housekeeping Alarm Input/Output Cable 10-18

(23)

10.4.1 OAM Serial Port Cable 10-21

10.4.2 Serial 1–4/F&f Cable 10-22

10.4.3 RS-232/422 Serial Port Cable 10-24

10.4.4 Orderwire Telephone Wire 10-25

10.4.5 COA Concatenating Cable 10-26

10.4.6 Straight Through Cable 10-27

10.4.7 Crossover Cable 10-29 10.5 Signal Cable 10-31 10.5.1 75 Ω 8xE1 Cable 10-31 10.5.2 75 Ω 16xE1 Cable 10-33 10.5.3 120 Ω 8xE1 Cable 10-35 10.5.4 120 Ω 16xE1 Cable 10-37 10.5.5 E3/DS3/STM-1 Cable 10-39

10.5.6 Extended Subrack Service Connection Cable 10-41

10.6 Clock Cable 10-43

10.6.1 Clock Cable 10-43

10.6.2 1/2-Channel Clock Transfer Cable 10-45

A Indicator Description for Equipment and Board

A-1

A.1 Cabinet Indicator Description A-1

A.2 Board Indicator Description A-2

B Board Version Description

B-1

B.1 Board Version List B-1

B.2 Version Description B-4

B.2.1 Optical Line Interface Board B-4

B.2.2 Ethernet Processing Board B-5

B.2.3 Cross-Connect and SCC boards B-7

B.2.4 Other Boards B-8

C Power Consumption and Weight

C-1

(24)

Figures

Figure 1-1 The OptiX OSN 3500 1-1

Figure 1-2 Components and architecture of the OptiX OSN 3500 1-2

Figure 1-3 The OptiX OSN 2500 1-3

Figure 1-4 Components and architecture of the OptiX OSN 2500 1-4

Figure 1-5 The OptiX OSN 1500A 1-5

Figure 1-6 The OptiX OSN 1500B 1-5

Figure 2-1 The 300-mm deep ETSI cabinet 2-2

Figure 2-2 The ETSI cabinet configuration 2-3

Figure 2-3 The power distribution unit 2-4

Figure 3-1 Structure of the OptiX OSN 3500 subrack 3-2

Figure 3-2 Slot distribution of the OptiX OSN 3500 3-3

Figure 3-3 Structure of the OptiX OSN 2500 subrack 3-10

Figure 3-4 Slot distribution of the OptiX OSN 2500 (before slot segmentation) 3-11

Figure 3-5 Access capacity of the OptiX OSN 2500 (before slot segmentation) 3-11

Figure 3-6 Slot distribution of the OptiX OSN 2500 (after slot segmentation) 3-12

Figure 3-7 Access capacity of the OptiX OSN 2500 (after slot segmentation) 3-12

Figure 3-8 Structure of the OptiX OSN 1500A 3-19

Figure 3-9 Slot distribution of the OptiX OSN 1500A (before slot segmentation) 3-19

Figure 3-10 Slot distribution of the OptiX OSN 1500A (after slot segmentation) 3-20

Figure 3-11 Access capacity of the OptiX OSN 1500A 3-20

Figure 3-12 Structure of the OptiX OSN 1500B 3-24

Figure 3-13 Slot distribution of the OptiX OSN 1500B (before slot segmentation) 3-25

Figure 3-14 Access capacity of the OptiX OSN 1500B (before slot segmentation) 3-25

Figure 3-15 Slot distribution of the OptiX OSN 1500B (after slot segmentation) 3-26

(25)

Figure 4-1 Board appearance 4-11

Figure 5-1 The principle block diagram of the SL64 5-3

Figure 5-2 The front panel of the SL64 5-4

Figure 5-3 The principle block diagram of the SF16 5-9

Figure 5-4 The front panel of the SL16 and the SF16 5-10

Figure 5-5 The principle block diagram of the SL4/SLD4/SLQ4 5-16

Figure 5-6 The front panel of the SL4, SLQ4, and SLD4 5-18

Figure 5-7 The principle block diagram of the SLT1/SLQ1/SL1 5-23

Figure 5-8 The front panel of the SLT1/SLQ1/SL1 5-24

Figure 5-9 The front panel of the R1SL4 and R1SLD4 5-29

Figure 5-10 The front panel of the R1SL1 and R1SLQ1 5-29

Figure 5-11 The principle block diagram of the SEP1 5-34

Figure 5-12 The front panel of the SEP1, EU08, OU08, and TSB8 5-35

Figure 5-13 1:3 TPS protection of the SEP1 in the OptiX OSN 3500 5-37

Figure 5-14 Board distribution upon two-group 1:3 TPS for the SEP1 in the OptiX OSN 3500 5-38

Figure 5-15 Board distribution upon two-group 1:1 TPS for the SEP1 in the OptiX OSN 2500 5-39

Figure 5-16 Board distribution upon 1:1 TPS for the SEP1 in the OptiX OSN 1500B 5-39

Figure 6-1 The functional block diagram of the SPQ4 6-3

Figure 6-2 The front panel of the SPQ4 and MU04 6-4

Figure 6-3 The 1:3 TPS protection of the SPQ4 in the OptiX OSN 3500 6-6

Figure 6-4 Board distribution upon two-group 1:3 TPS for the SPQ4 in the OptiX OSN 3500 6-7

Figure 6-5 Board distribution upon two-group 1:1 TPS for the SPQ4 in the OptiX OSN 2500 6-8

Figure 6-6 Board distribution upon 1:1 TPS for the SPQ4 in the OptiX OSN 1500B 6-8

Figure 6-7 The functional block diagram of the PD3, PL3, and PL3A 6-12

Figure 6-8 The mapping and multiplexing process of E3/DS3 signals 6-13

Figure 6-9 The front panel of the PD3, PL3, PL3A, C34S and D34S 6-14

Figure 6-10 The 1:3 TPS protection of the PD3 in the OptiX OSN 3500 6-16

Figure 6-11 Board layout upon 1:3 TPS protection for the PL3/PD3 in the OptiX OSN 3500 6-18

Figure 6-12 Board layout upon 1:1 TPS protection for the PL3/PD3 n the OptiX OSN 2500 6-19

Figure 6-13 Board layout upon 1:1 TPS protection for the PL3/PD3 in the OptiX OSN 1500B 6-20

Figure 6-14 The functional block diagram of the PQ1/PQM 6-23

Figure 6-15 The mapping and multiplexing process of E1/T1 signals 6-24

Figure 6-16 The front panel of the PQ1, PQM, D75S, D12S, and D12B 6-25

Figure 6-17 The 1:8 TPS protection of the PQ1 in the OptiX OSN 3500 6-27

(26)

Figure 6-20 The front panel of the PD1, PL1, L12S and L75S 6-32

Figure 6-21 Board distribution upon 1:2 TPS protection of the PD1 in the OptiX OSN 2500 6-34

Figure 6-22 Board distribution upon 1:1 TPS protection of the PD1 6-35

Figure 7-1 Functional block diagram of the EGT2 7-5

Figure 7-2 Front panel of the EGT2/EFT8/EFT4/EFF8/ETF8 7-6

Figure 7-3 Functional block diagram of the EGS2 7-14

Figure 7-4 Front panel of the EGS2/EFS4/EFS0/ETS8 7-15

Figure 7-5 Board distribution upon 1:1 TPS protection of the OptiX OSN 3500 7-18

Figure 7-6 Board configuration upon 1:1 TPS protection of the OptiX OSN 2500 7-19

Figure 7-7 Board distribution upon 1:1 TPS protection of the OSN 1500 7-19

Figure 7-8 Functional block diagram of the EMR0 7-27

Figure 7-9 Front panel of the EMR0 and EGR2 7-29

Figure 7-10 Functional block diagram of the ADL4 and ADQ1 7-35

Figure 7-11 Front panel of the ADL4 and ADQ1 7-37

Figure 7-12 Front panel of the IDL4 and IDQ1 7-42

Figure 7-13 The functional block diagram of the MST4 7-47

Figure 7-14 The front panel of the MST4 7-48

Figure 8-1 Functional block diagram of the GXCS/EXCS/UXCS 8-3

Figure 8-2 Front panel of the GXCS, EXCS, UXCS and XCE 8-4

Figure 8-3 Configuration of extended subracks 8-6

Figure 8-4 Functional block diagram of the CXL16 8-11

Figure 8-5 Front panel of the CXL1, CXL4 and CXL16 8-11

Figure 8-6 Functional block diagram of the SCC 8-17

Figure 8-7 Position of respective orderwire bytes in the SDH frame 8-18

Figure 8-8 The front panel of the SCC and the GSCC 8-19

Figure 8-9 Functional block diagram of the CRG 8-23

Figure 8-10 Front panel of the CRG 8-24

Figure 9-1 Functional block diagram of the LWX 9-2

Figure 9-2 Front panel of the LWX 9-4

Figure 9-3 MR2A/MR2B/MR2C serves as OTM station 9-8

Figure 9-4 MR2A/MR2B/MR2C and LWX form OADM station adding/dropping two channels of signals 9-8

Figure 9-5 Functional block diagram of the MR2A/MR2B/MR2C 9-9

Figure 9-6 Front panel of the MR2A 9-10

Figure 9-7 Position of BA and PA in the network 9-13

Figure 9-8 Functional block diagram of the BA2/BPA 9-13

(27)

Figure 9-10 Appearance of the 61COA (PA) 9-16

Figure 9-11 Appearance of the 62COA 9-17

Figure 9-12 Application of Raman amplifier (62COA) 9-18

Figure 9-13 Functional block diagram of 61COA 9-18

Figure 9-14 Front panel of the COA 9-19

Figure 9-15 Front panel of the 62COA 9-19

Figure 9-16 E2000 flange and fiber connector 9-20

Figure 9-17 Serial communication between the COA and the SCC 9-21

Figure 9-18 The position of the 61COA in the ETSI cabinet 9-23

Figure 9-19 The position of DCU in the optical transmission system 9-25

Figure 9-20 Functional block diagram of the DCU 9-26

Figure 9-21 Front panel of the DCU 9-27

Figure 9-22 Functional block diagram of the AUX 9-33

Figure 9-23 Functional block diagram of the EOW 9-34

Figure 9-24 Position of orderwire bytes in the SDH frame 9-34

Figure 9-25 Functional block diagram of the SAP 9-35

Figure 9-26 Functional block diagram of the SEI 9-36

Figure 9-27 Connection of alarm input and alarm output (OptiX OSN 3500) 9-45

Figure 9-28 Connection of alarm input and alarm output (OptiX OSN 2500) 9-45

Figure 9-29 Connection of cabinet alarm indicators (OptiX OSN 3500) 9-46

Figure 9-30 Connection of cabinet alarm indicators (OptiX OSN 2500) 9-46

Figure 9-31 The principle block diagram of the PIU 9-48

Figure 9-32 Functional block diagram of the R1PIU 9-49

Figure 9-33 Functional block diagram of the R2PIU 9-50

Figure 9-34 Front panel of the N1PIU 9-51

Figure 9-35 Front panel of the Q1PIU 9-51

Figure 9-36 Front panel of the R1PIU 9-52

Figure 9-37 Front panel of the R2PIU 9-53

Figure 9-38 Appearance of the power box 9-55

Figure 9-39 Rear view of the power box 9-57

Figure 9-40 Appearance of the FAN (OptiX OSN 3500) 9-59

Figure 9-41 Functional block diagram of the N1FAN 9-60

Figure 9-42 Functional block diagram of the R1FAN 9-61

Figure 9-43 Front panel of the R1FAN 9-62

(28)

Figure 10-3 FC/PC optical interface 10-4

Figure 10-4 E2000/APC optical interface 10-5

Figure 10-5 –48 V cabinet power cable/cabinet BGND power cable 10-6

Figure 10-6 Cabinet PGND power cable 10-6

Figure 10-7 Structure of the cabinet door grounding cable 10-7

Figure 10-8 Structure of the subrack power cable 10-8

Figure 10-9 Structure of the –48 V/–60 V power cable 10-9

Figure 10-10 Structure of the PGND power cable 10-10

Figure 10-11 Structure of the HUB/COA power cable 10-11

Figure 10-12 Structure of the subrack power cable 10-12

Figure 10-13 Structure of the cabinet indicator cable 10-14

Figure 10-14 Structure of the indicator/alarm concatenating cable between OSN subracks 10-16

Figure 10-15 Alarm concatenating cable between OSN subrack and other subrack 10-17

Figure 10-16 Structure of the housekeeping alarm input/output cable 10-19

Figure 10-17 Structure of the OAM serial port cable 10-21

Figure 10-18 Structure of the serial 1–4/F&f cable 10-23

Figure 10-19 Structure of the RS-232/422 serial port cable 10-24

Figure 10-20 Structure of ordinary telephone wire 10-25

Figure 10-21 Structure of the COA concatenating serial port cable 10-27

Figure 10-22 Structure of straight through cable 10-28

Figure 10-23 Structure of the crossover cable 10-29

Figure 10-24 Structure of the 75 Ω 8xE1 cable 10-31

Figure 10-25 Structure of the 75 Ω 16xE1 cable 10-33

Figure 10-26 Structure of the 120 Ω 8 x E1 cable 10-36

Figure 10-27 Structure of the 120 Ω 16xE1 cable 10-37

Figure 10-28 Structure of the E3/DS3/STM-1 cable 10-40

Figure 10-29 Structure of the extended subrack service connection cable 10-41

Figure 10-30 Structure of the 75 Ω clock cable 10-44

Figure 10-31 Structure of the 120 Ω clock cable 10-44

Figure 10-32 Structure of the 1-channel 120 Ω/75 Ω clock transfer cable 10-45

(29)

Tables

Table 2-1 Types of the cabinets for OptiX OSN products 2-1

Table 2-2 Description of ETSI cabinet indicators 2-3

Table 2-3 Mapping relation between terminals and PIU boards 2-4

Table 2-4 Technical parameters of the ETSI cabinet 2-5

Table 3-1 Slot mapping table for OptiX OSN 3500 3-3

Table 3-2 The relation between processing boards and slots for the OptiX OSN 3500 (80 Gbit/s cross-connect

capacity) 3-4

Table 3-3 The relation between processing boards and slots for the OptiX OSN 3500 (40 Gbit/s cross-connect

capacity) 3-6

Table 3-4 The relation between interface boards and slots for the OptiX OSN 3500 3-7

Table 3-5 The relation between other boards and slots for the OptiX OSN 3500 3-8

Table 3-6 Technical parameters of the OptiX OSN 3500 subrack 3-9

Table 3-7 Slot mapping table for the OptiX OSN 2500 3-13

Table 3-8 The relation between processing boards and slots for the OptiX OSN 2500 3-13

Table 3-9 The relation between interface boards and slots for the OptiX OSN 2500 3-16

Table 3-10 The relation between other boards and slots for the OptiX OSN 2500 3-16

Table 3-11 Technical parameters of the OptiX OSN 2500 subrack 3-17

Table 3-12 The relation between boards and slots for the OptiX OSN 2500 REG 3-18

Table 3-13 The relation between processing boards and slots for the OptiX OSN 1500A 3-21

Table 3-14 The relation between other boards and slots for the OptiX OSN 1500A 3-22

Table 3-15 Technical parameters of the OptiX OSN 1500A 3-23

Table 3-16 Slot mapping table for the OptiX OSN 1500B 3-27

Table 3-17 The relation between processing boards and slots for the OptiX OSN 1500B 3-27

Table 3-18 The relation between interface boards and slots for the OptiX OSN 1500B 3-29

Table 3-19 The relation between other boards and slots for the OptiX OSN 1500B 3-30

(30)

Table 4-1 SDH boards 4-2

Table 4-2 PDH boards 4-3

Table 4-3 Data processing boards 4-5

Table 4-4 Cross-Connect and SCC boards 4-7

Table 4-5 Other boards 4-9

Table 5-1 Slots for the SL64 5-1

Table 5-2 Relationship between C2 setting and service type for the SL64 5-5

Table 5-3 Technical parameters of the SL64 5-5

Table 5-4 Parameters of the fixed wavelength interfaces complying with ITU-T G.692 5-6

Table 5-5 Slots for the SL16 and SF16 5-7

Table 5-6 Relationship between C2 setting and service type for the SF16/SL16 5-11

Table 5-7 Technical parameters of the SL16 5-12

Table 5-8 Technical parameters of the SF16 5-13

Table 5-9 Parameters of the fixed wavelength interfaces complying with G.692 5-14

Table 5-10 Slots for the SLQ4, SLD4 and SL4 5-15

Table 5-11 Relationship between C2 setting and service type for the SL4/SLD4/SLQ4 5-19

Table 5-12 Technical parameters of the SL4, SLD4 and SLQ4 5-19

Table 5-13 Slots for the SLT1, SLQ1, and SL1 5-21

Table 5-14 Relationship between C2 setting and service type for the SLT1/SLQ1/SL1 5-25

Table 5-15 Technical parameters of the SLT1, SLQ1, and SL1 5-26

Table 5-16 Slots for the R1SLD4/R1SL4/R1SLQ1/R1SL1 5-27

Table 5-17 Relationship between C2 setting and service type for half-slot optical processing boards 5-30

Table 5-18 Technical parameters of the R1SL4, R1SLD4, R1SLQ1, and R1SL1 5-31

Table 5-19 Slot for the SEP1, EU08, OU08, and TSB8 5-32

Table 5-20 Different access abilities of the SEP1 5-32

Table 5-21 Interfaces of the EU08 and OU08 5-36

Table 5-22 TPS protection of the SEP1 5-36

Table 5-23 Slot assignment of the SEP1, EU08, and TSB8 in the OptiX OSN 3500 5-38

Table 5-24 Slot assignment of the SEP1, EU08, and TSB8 in the OptiX OSN 2500 5-39

Table 5-25 Slot assignment of the SEP1, EU08, and TSB8 in the OptiX OSN 1500B 5-40

Table 5-26 Relationship between C2 setting and service type for the SEP1 5-40

Table 5-27 Technical parameters of the SEP1, EU08, OU08, and TSB8 5-41

Table 6-1 Slots for the SPQ4, MU04, and TSB8 6-1

Table 6-2 Interfaces on the MU04 6-5

Table 6-3 The TPS protection of the SPQ4 6-5

(31)

Table 6-5 Slot assignment of the SPQ4, MU04, and TSB8 in the OptiX OSN 2500 6-8

Table 6-6 Slot assignment of the SPQ4, MU04, and TSB8 in the OptiX OSN 1500B 6-9

Table 6-7 Relationship between C2 setting and service type for the SPQ4 6-9

Table 6-8 Technical parameters of the SPQ4 and MU04 6-10

Table 6-9 Slots for the PL3, PL3A, PD3, C34S, D34S, and TSB8 6-11

Table 6-10 Interfaces on the D34S 6-15

Table 6-11 The TPS protection of the PL3/PD3 6-15

Table 6-12 Relation between working and protection boards upon 1:3 TPS in the OptiX OSN 3500 6-17

Table 6-13 Slot assignment of the PL3/PD3, D34S and TSB8 in the OptiX OSN 3500 6-18

Table 6-14 Relation between working and protection boards upon 1:1 TPS in the OptiX OSN 2500 6-18

Table 6-15 Slot assignment of the PL3/PD3, D34S and TSB8 in the OptiX OSN 2500 6-19

Table 6-16 Relation between working and protection boards upon 1:1 TPS in the OptiX OSN 1500B 6-19

Table 6-17 Slot assignment of the PL3/PD3, D34S, and TSB8 in the OptiX OSN 1500B in the OptiX OSN

1500B 6-20

Table 6-18 Technical parameters of the PL3, PD3, PL3A, C34S and D34S 6-21

Table 6-19 Slots for the PQ1, PQM, D75S, D12S, and D12B 6-22

Table 6-20 Comparison between the PQ1 and PQM 6-22

Table 6-21 Comparison between the D75S, D12S, and D12B 6-25

Table 6-22 The TPS protection of the PQ1 and PQM 6-26

Table 6-23 Relation between working and protection boards upon 1:8 TPS in the OptiX OSN 3500 6-27

Table 6-24 Relation between working and protection boards upon 1:4 TPS in the OptiX OSN 2500 6-28

Table 6-25 Board distribution upon 1:2 TPS for the PQ1 or PQM in the OptiX OSN 1500B 6-29

Table 6-26 Technical parameters of the PQ1, PQM, D75S, D12S, and D12B 6-29

Table 6-27 Slots for the PD1, PL1, L75S, and L12S 6-31

Table 6-28 Comparison between the PL1, L75S, and L12S 6-33

Table 6-29 The TPS protection of the PD1 6-33

Table 6-30 Relation between working and protection boards upon 1:2 TPS of the PD1 in the OptiX OSN 2500

6-34

Table 6-31 Slot assignment upon 1:1 TPS protection of the PD1 in the OptiX OSN 1500B 6-35

Table 6-32 Technical parameters of the PD1, PL1, L75S, and L12S 6-36

Table 7-1 Slots for the EGT2/EFT8/EFT4/EFF8/ETF8 7-2

Table 7-2 Indicators of the EGT2 7-7

Table 7-3 Indicators of the EFF8 7-7

Table 7-4 Interfaces of the EGT2/EFT8/EFT4/EFF8/ETF8 7-7

Table 7-5 Parameters for the Ethernet interface of EGT2/EFT8/EFT4 7-8

(32)

Table 7-7 Slots for the EGS2/EFS4/EFS0/EFF8/ETF8/ETS8 7-11

Table 7-8 Indicators of the EGS2 7-16

Table 7-9 Interfaces of EGS2/EFS4/EFS0/ETS8 7-16

Table 7-10 TPS protection of the EFS0 7-17

Table 7-11 Slot assignment of the EFS0, ETS8 and TSB8 in the OptiX OSN 3500 7-18

Table 7-12 Parameters for the Ethernet interface on the EGS2/EFS4/EFS0 7-20

Table 7-13 N1 and N2 EGS2/EFS4/EFS0 boards 7-21

Table 7-14 Technical parameters of EGS2/EFS4/EFS0/ETS8 7-22

Table 7-15 Slots for the EMR0 and EGR2 7-24

Table 7-16 Indicators of the EGR2 7-30

Table 7-17 Interfaces of EMR0 and EGR2 7-30

Table 7-18 Parameters for the Ethernet interface on the EMR0 and EGR2 7-31

Table 7-19 Version description of the EMR0 and the EGR2 7-32

Table 7-20 Technical Parameters of the EMR0 and EGR2 7-33

Table 7-21 Slots for the ADL4 and ADQ1 7-34

Table 7-22 Parameters for the ATM port of the ADL4/ADQ1 7-38

Table 7-23 Technical parameters of the ADL4 and ADQ1 7-39

Table 7-24 Slots for the IDL4 and IDQ1 7-40

Table 7-25 Paired slots for the IDL4 and the IDQ1 7-43

Table 7-26 Parameters for the ATM interface on the IDL4/IDQ1 7-43

Table 7-27 Technical parameters of the IDL4 and IDQ1 7-44

Table 7-28 Slots for the MST4 7-45

Table 7-29 The service types and rates provided by the MST4 7-46

Table 7-30 Technical parameters of the MST4 7-49

Table 8-1 Comparison among GXCS, EXCS, UXCS and XCE. 8-2

Table 8-2 Indicators of the GXCS, EXCS, UXCS and XCE 8-5

Table 8-3 External clock interface of the GXCS, EXCS and UXCS 8-6

Table 8-4 N1 and N2 GXCSA boards 8-7

Table 8-5 Technical parameters of the GXCS, EXCS, UXCS and XCE 8-7

Table 8-6 Comparison among CXL1, CXL4 and CXL16 8-9

Table 8-7 Indicators of the CXL1, CXL4 and CXL16 8-12

Table 8-8 Interfaces of CXL 8-13

Table 8-9 Correspondence between C2 byte setting and service type 8-14

Table 8-10 Technical parameters of the CXL1, CXL4 and CXL16 8-14

Table 8-11 Switch description of the SCC 8-19

(33)

Table 8-13 Technical parameters of the SCC 8-21

Table 8-14 Switch description of the CRG 8-24

Table 8-15 Indicator description of the CRG 8-25

Table 8-16 Technical parameters of the CRG 8-26

Table 9-1 Slots for the LWX 9-1

Table 9-2 Interfaces of the LWX 9-4

Table 9-3 Client-side optical interface parameters of the LWX 9-5

Table 9-4 DWDM-side optical interface parameters of the LWX 9-6

Table 9-5 Technical parameters of the LWX 9-6

Table 9-6 Slots for the MR2A, MR2B and MR2C 9-7

Table 9-7 Interfaces of the MR2A/MR2B/MR2C 9-10

Table 9-8 Technical parameters of the MR2A/MR2B/MR2C 9-11

Table 9-9 Slots for the BA2 and BPA 9-12

Table 9-10 Technical parameters of the BA2 and BPA 9-15

Table 9-11 Indicators of the 61COA/62COA 9-20

Table 9-12 Relation between output alarm and interface pin 9-21

Table 9-13 Technical parameters of the 61COA and 62COA 9-23

Table 9-14 Technical parameters of the DCU 9-28

Table 9-15 Slots for the AUX, EOW, SAP and SEI 9-30

Table 9-16 Indicator of the AUX 9-36

Table 9-17 Interfaces of the N1AUX 9-37

Table 9-18 Pin assignment of CLK1 and CLK2 interface 9-38

Table 9-19 Pin assignment of ETH, COM, EXT and F1 interface 9-38

Table 9-20 Pin assignment of F&f interface 9-38

Table 9-21 Pin assignment of PHONE, V1 and V2 interface 9-39

Table 9-22 Pin assignment of LAMP1 and LAMP2 interface 9-39

Table 9-23 Pin assignment of ALMO1 and ALMO2 interface 9-39

Table 9-24 Pin assignment of OAM interface 9-40

Table 9-25 Pin assignment of S1, S2, S3 and S4 interface 9-40

Table 9-26 Pin assignment of ALMI1 interface 9-40

Table 9-27 Pin assignment of ALMI2 interface 9-41

Table 9-28 Pin assignment of ALMI3 interface 9-41

Table 9-29 Pin assignment of ALMI4 interface 9-41

Table 9-30 Interfaces on the R1/R2AUX front panel 9-42

(34)

Table 9-33 Interfaces of the SAP 9-43

Table 9-34 Interfaces of the SEI 9-43

Table 9-35 Jumper J9 setting 9-46

Table 9-36 Technical parameters of the AUX, EOW, SAP and SEI 9-47

Table 9-37 Interfaces on the N1PIU front panel 9-51

Table 9-38 Interfaces of the Q1PIU 9-52

Table 9-39 Indicator of the R1PIU 9-52

Table 9-40 Interfaces of the Q1PIU 9-52

Table 9-41 Indicators and the switch on the R2PIU front panel 9-53

Table 9-42 Technical parameters of the PIU 9-54

Table 9-43 Indicators of the power box 9-57

Table 9-44 Interfaces on the power box front panel 9-57

Table 9-45 Technical parameters of the UPM 9-58

Table 9-46 Indicator of the N1FAN 9-61

Table 9-47 Indicators of the R1FAN 9-62

Table 9-48 Technical parameters of the FAN 9-62

Table 10-1 Classification of fiber jumper 10-2

Table 10-2 Classification of fiber connector 10-3

Table 10-3 OptiX OSN 3500/2500/1500 power cables and grounding cables 10-5

Table 10-4 Pin assignment of subrack power cable 10-8

Table 10-5 Pin assignment of the –48 V/–60 V power cable 10-10

Table 10-6 Pin assignment of the HUB power cable 10-12

Table 10-7 Pin assignment of the UPM power cable 10-13

Table 10-8 OptiX OSN 3500/2500/1500 alarm cable 10-14

Table 10-9 Pin assignment of the cabinet indicator cable 10-15

Table 10-10 Pin assignment of indicator/alarm concatenating cables between OSN subracks 10-16

Table 10-11 Pin assignment of alarm concatenating cable between OSN subrack and other subrack 10-18 Table 10-12 Pin assignment of housekeeping alarm input/output cable for OptiX OSN 3500/2500 10-19

Table 10-13 Pin assignment of housekeeping alarm input/output cable for OptiX OSN 1500 10-20

Table 10-14 OptiX OSN 3500/2500/1500 management cables 10-21

Table 10-15 Pin assignment of OAM serial port cable 10-22

Table 10-16 Pin assignment of the serial 1–4/F&f cable 10-23

Table 10-17 Pin assignment of the RS-232/422 serial port cable 10-25

Table 10-18 Pin assignment of ordinary telephone wire 10-26

Table 10-19 pin assignment of the COA concatenating serial port cable 10-27

(35)

Table 10-21 Pin assignment of crossover cable 10-29

Table 10-22 OptiX OSN 3500/2500/1500 signal cables 10-31

Table 10-23 Pin assignment of the 75 Ω 8xE1 cable 10-32

Table 10-24 Pin assignment of the 75 Ω 16xE1 cable 10-33

Table 10-25 Pin assignment of the 120 Ω 8 x E1 cable 10-36

Table 10-26 Pin assignment of the 120 Ω 16xE1 cable 10-38

Table 10-27 Pin assignment of the extended subrack service connection cable 10-42

Table 10-28 OptiX OSN 3500/2500/1500 clock cables 10-43

Table 10-29 Pin assignment of the 120 Ω clock cable 10-44

Table 10-30 Pin assignment of the 75 Ω/120 Ω clock transfer cable 10-46

Table B-1 N1 and N2 optical line interface boards B-5

Table B-2 Ethernet processing board version B-5

Table B-3 N1 and N2 Ethernet processing boards B-6

Table B-4 N1 and N2 GXCSA boards B-7

Table B-5 N1SCC, N1GSCC and N2GSCC B-7

Table B-6 Q1 and Q2 CXL1/4/16 boards B-8

(36)

About This Manual

Release Notes

This manual covers:

„ The OptiX OSN 3500 Intelligent Optical Transmission System, version V100R003 „ The OptiX OSN 2500 Intelligent Optical Transmission System, version V100R003 „ The OptiX OSN 1500 Intelligent Optical Transmission System, version V100R003

Related Manuals

The following table shows the manuals of the OptiX OSN 3500, OSN 2500, and OSN 1500.

OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Documentation Guide OptiX OSN 3500 Intelligent

Optical Transmission System Technical Manual System Description

OptiX OSN 2500 Intelligent Optical Transmission System Technical Manual System Description

OptiX OSN 1500 Intelligent Optical Transmission System Technical Manual System Description

OptiX OSN 3500 Intelligent Optical Transmission System Installation Manual

OptiX OSN 2500 Intelligent Optical Transmission System Installation Manual

OptiX OSN 1500 Intelligent Optical Transmission System Installation Manual

OptiX OSN 3500 Intelligent Optical Transmission System Electronic Documentation

OptiX OSN 2500 Intelligent Optical Transmission System Electronic Documentation

OptiX OSN 1500 Intelligent Optical Transmission System Electronic Documentation OptiX OSN 3500 Intelligent

Optical Transmission System Technical Manual Networking and Application

OptiX OSN 2500 Intelligent Optical Transmission System Technical Manual Networking and Application

OptiX OSN 1500 Intelligent Optical Transmission System Technical Manual Networking and Application

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Hardware Description Manual OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Maintenance Manual Routine Maintenance

(37)

OptiX OSN 3500 OptiX OSN 2500 OptiX OSN 1500

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Maintenance Manual Troubleshooting

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Maintenance Manual Alarm and Performance Event

OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Commissioning Guide OptiX OSN 3500/2500/1500 Intelligent Optical Transmission System Configuration Guide

Note: The manual name with OptiX OSN 3500/2500/1500 indicates that the manual is shared by the OptiX OSN 3500, OptiX OSN 2500, and OptiX OSN 1500.

Main points of the manuals for the OptiX OSN series products are as follows.

„ Documentation Guide

Introduces the contents and usage of the manuals.

„ Technical Manual System Description

Introduces the functionality, structure, performance, specifications, and theory of the product.

„ Technical Manual Networking and Application

Introduces the networking, protection, and application of the product.

„ Hardware Description Manual

Introduces the hardware of the product, including the cabinet, subrack, power, fan, board, and a variety of interfaces.

„ Maintenance Manual Routine Maintenance

Introduces the main items and precautions involved in routing maintenance.

„ Maintenance Troubleshooting

Guides the analysis and troubleshooting of common faults.

„ Maintenance Alarm and Performance Event

Guides the way of processing alarms and performance events.

„ Installation Manual

Guides the on-site installation of the product, covering the installation of cabinet, subrack and components, and grounding specifications.

„ Commissioning Guide

Introduces the equipment commissioning process, including indices of hardware, software, and service operation.

„ Configuration Guide

Introduces the way and procedures of configuring SDH services, Ethernet private line services, Ethernet LAN services, RPR services, and ATM services on the T2000.

„ Electronic Documentation (CD-ROM)

Covers all the preceding manuals. Acrobat Reader is attached.

Organization

(38)

Chapter Description

Chapter 1 Equipment

Architecture Introduces the architecture of the OptiX OSN 3500, OptiX OSN 2500 and OptiX OSN 1500.

Chapter 2 Cabinet Describes the dimensions, appearance, and technical

specifications of the cabinets used by the OptiX OSN 3500, OptiX OSN 2500, and OptiX OSN 1500, and the

configuration in the cabinets.

Chapter 3 Subrack Introduces the structure of the OptiX OSN 3500, OptiX OSN

2500 and OptiX OSN 1500 subracks. Lists the board types that can seat in the slots of the subracks.

Chapter 4 Board

Classification and List Classifies the boards into SDH boards, PDH boards, data processing boards, cross-connect and SCC boards, and

other boards, and gives a detailed list of all available boards.

Chapter 5 SDH Boards Introduces SDH boards in terms of functionality, principle,

front panel, DIP switch, interfaces, board protection, version description, and technical parameters.

Chapter 6 PDH Boards Introduces PDH boards in terms of functionality, principle,

front panel, DIP switch, interfaces, board protection, version description, and technical parameters.

Chapter 7 Data

Processing Boards Introduces data processing boards in terms of functionality, principle, front panel, DIP switch, interfaces, board

protection, version description, and technical parameters. Chapter 8

Cross-Connect and System Control Boards

Introduces cross-connect and SCC boards in terms of functionality, principle, front panel, DIP switch, interfaces, board protection, version description, and technical parameters.

Chapter 9 Other Boards Introduces other boards (for example, the system auxiliary

interface board) in terms of functionality, principle, front panel, DIP switch, interfaces, board protection, version description, and technical parameters.

Chapter 10 Cables Introduces the external and the internal cables of the OptiX

OSN 3500, OptiX OSN 2500 and OptiX OSN 1500, and gives detailed description in terms of the structure, appearance, pin assignment, and technical parameters.

Appendix A–Appendix D Includes four appendices:

Appendix A Quick Reference for Indicators

Appendix B Power Consumption and Weight of Boards Appendix C Board Version Configuration

Appendix D Abbreviations and Acronyms

The appendices give a quick searching to equipment-related information during routine maintenance.

Readers can locate the chapter where required information is covered through appendices quickly.

(39)

Intended Audience

This manual is intended for:

„ Network administrator „ Maintenance engineer „ Provisioning engineer

Conventions

The manual uses the following conventions.

Symbol Conventions

Symbol Description

Warning A warning notice with this symbol indicates high voltage could result in harm to person.

Warning A warning notice with this symbol indicates strong laser beam could result in personal injury.

Warning

A warning notice with this symbol indicates a risk of personal injury.

Caution

A caution notice with this symbol indicates a risk to equipment damage or loss of data.

Caution A caution notice with this symbol indicates the equipment is static-sensitive.

Important

Note An important note notice with this symbol helps you avoid an undesirable situation or indicates important supplementary

information.

Note A note notice with this symbol indicates additional, helpful,

non-critical information.

GUI Conventions

Convention Description

< > Button name are inside angle brackets. For example, click the <OK>

button

[ ] Window names, menu items, data table and field names are inside

square brackets. For example, pop up the [New User] window.

/ Multi-level menus are separated by forward slashes. For example,

(40)

1

Equipment Architecture

This chapter introduces the architecture of the OptiX OSN 3500, OptiX OSN 2500, OptiX OSN 1500A, and OptiX OSN 1500B.

1.1

Architecture of the OptiX OSN 3500

Figure 1-1 shows the appearance of the OptiX OSN 3500.

Figure 1-1 The OptiX OSN 3500

(41)

Figure 1-2 shows the components when the equipment seating in a 300-mm deep ETSI cabinet.

The OptiX OSN 3500 is composed of cabinet, side panel, power distribution unit, subrack, fixing frame for order wire, boards, and cables.

1 2 3 4 5 6

1. Cabinet 2. Power distribution unit 3. Upper subrack 4. Fixing frame for order wire 5. Lower subrack 6. Side panel

(42)

1.2

Architecture of the OptiX OSN 2500

Figure 1-3 shows the appearance of the OptiX OSN 2500.

Figure 1-3 The OptiX OSN 2500

The OptiX OSN 2500 can be seated in a 300-mm or 600-mm deep ETSI cabinet, or in a standard 19-inch cabinet. Figure 1-4 shows the components when the equipment seating in a 300-mm deep ETSI cabinet.

The OptiX OSN 2500 is composed of cabinet, side panel, power distribution unit, subrack, fixing frame for order wire, boards, and cables.

(43)

1 2 3 4 5 6 7

1. Cabinet 2. Power distribution unit 3. Upper subrack 4. Fixing frame for order wire 5. Middle subrack 6. Lower subrack 7. Side panel

(44)

1.3

Architecture of the OptiX OSN 1500A

The OptiX OSN 1500A is a case-shape equipment. It can be seated in a 300-mm or 600-mm deep ETSI cabinet, a standard 19-inch cabinet, or be hanged on the wall. Figure 1-5 shows the appearance of the OptiX OSN 1500A.

Figure 1-5 The OptiX OSN 1500A

1.4

Architecture of the OptiX OSN 1500B

The OptiX OSN 1500B is a case-shape equipment. It can be seated in a 300-mm or 600-mm deep ETSI cabinet, a standard 19-inch cabinet, or be hanged on the wall. Figure 1-6 shows the appearance of the OptiX OSN 1500B.

(45)

2

Cabinet

This chapter introduces the dimensions, technical specifications, and the

configuration of the cabinet equipped by the OptiX OSN 3500, OptiX OSN 2500, OptiX OSN 1500A, or OptiX OSN 1500B.

2.1

Types

Table 2-1 shows the cabinets that can house the OptiX OSN 3500, OptiX OSN 2500, OptiX OSN 1500A, and OptiX OSN 1500B.

Table 2-1 Types of the cabinets for OptiX OSN products Cabinet

Product

ETSI

300-mm deep ETSI 600-mm deep 19-inch cabinet Access network cabinet

Hanging

OptiX OSN 3500 9 9

OptiX OSN 2500 9 9 9

OptiX OSN 1500A 9 9 9 9 9

OptiX OSN 1500B 9 9 9 9

Notes: These cabinets should be provided by Huawei. Figure 2-1 shows the appearance of the ETSI cabinet.

(46)
(47)

2.2

Cabinet Configuration

There are indicators and a power distribution unit on the top of ETSI cabinet, as shown in Figure 2-2.

1 2

Power Critical MajorMinor

Power distribution unit

1. Cabinet indicators 2. Power distribution unit

Figure 2-2 The ETSI cabinet configuration

2.2.1 Cabinet Indicators

Table 2-2 shows the description of cabinet indicators.

Table 2-2 Description of ETSI cabinet indicators

Indicator Status Description

On The equipment is powered on.

Power indicator - Power (green)

Off The equipment is not powered on.

On There are critical alarms.

Critical alarm indicator - Critical (red)

Off There are no critical alarms.

On There are major alarms.

Major alarm indicator - Major (orange)

Off There are no major alarms.

On There are minor alarms.

Minor alarm indicator - Minor (yellow)

Off There are no minor alarms.

Note: The cabinet indicators are driven by subrack, so you should connect the cable properly and power on the subrack first.

References