FBQ-B8V1-B8V3B
RXS20-25-35E
(single phase)
Split Heat Pump
Condensing Units
1
1
• Split Sky Air • Outdoor Units
1
1
2
• Split Sky Air • Outdoor Units
2
NOMINAL INPUT
RXS20E2V1B RXS25E2V1B RXS35E2V1BFor combination indoor units + outdoor units Indoor Units FTXS20D3VMW FTXS25D3VMW FTXS35D3VMW Cooling
capacity MinimumStandard kWkW 1.22.0 1.22.5 1.23.4
Maximum kW 2.6 3.0 3.8
Heating
capacity MinimumStandard kWkW 1.22.7 1.23.4 1.24.0
Maximum kW 4.1 4.5 5.0
Nominal input Cooling Minimum kW 0.30 0.3 0.30
Standard kW 0.48 0.6 1.00 Maximum kW 0.82 0.8 1.22 Heating Minimum kW 0.29 0.29 0.29 Standard kW 0.65 0.83 1.08 Maximum kW 1.29 1.34 1.55 For combination indoor units + outdoor units EER Nominal 4.17 4.17 3.40 COP Nominal 4.15 4.10 3.70 Energy Labeling Directive Cooling A A Heating A A
Annual energy consumption kWh 240 300 500
Indoor Units FTXS20D3VML FTXS25D3VML FTXS35D3VML
Cooling
capacity MinimumStandard kWkW 1.22.0 1.22.5 1.23.4
Maximum kW 2.6 3.0 3.8
Heating
capacity MinimumStandard kWkW 1.22.7 1.23.4 1.24.0
Maximum kW 4.1 4.5 5.0
Nominal input Cooling Minimum kW 0.30 0.3 0.30
Standard kW 0.48 0.6 1.00 Maximum kW 0.82 0.8 1.22 Heating Minimum kW 0.29 0.29 0.29 Standard kW 0.65 0.83 1.08 Maximum kW 1.29 1.34 1.55 For combination indoor units + outdoor units EER Nominal 4.17 4.17 3.40 COP Nominal 4.15 4.10 3.70 Energy Labeling Directive Cooling A A Heating A A
Annual energy consumption kWh 240 300 500
Indoor Units FDXS25EAVMB FDXS35EAVMB
Cooling
capacity MinimumStandard kWkW 1.32.4 1.43.4
Maximum kW 3.0 3.8
Heating
capacity MinimumStandard kWkW 1.33.2 1.44.0
Maximum kW 4.5 5.0
Nominal input Cooling Standard kW 0.69 1.09
Heating Standard kW 0.91 1.18 For combination indoor units + outdoor units EER Nominal 3.48 3.12 COP Nominal 3.52 3.39 Energy Labeling Directive Cooling A B Heating B C
Annual energy consumption kWh 345 545
1
2
• Split Sky Air • Outdoor Units
3
Cooling
capacity MinimumStandard kWkW 1.22.5 1.23.5
Maximum kW 3.0 3.8
Heating
capacity MinimumStandard kWkW 1.23.4 1.44.0
Maximum kW 4.5 5.0
Nominal input Cooling Minimum kW 0.30 0.30
Standard kW 0.65 1.13 Maximum kW 0.86 1.26 Heating Minimum kW 0.29 0.29 Standard kW 0.98 1.23 Maximum kW 1.49 1.85 For combination indoor units + outdoor units EER Nominal 3.85 3.10 COP Nominal 3.47 3.25 Energy Labeling Directive Cooling A B Heating B C
Annual energy consumption kWh 325 565
Indoor Units FFQ25B8V1B FFQ35B8V1B
Cooling
capacity Standard kW 2.5 3.4
Heating
capacity Standard kW 3.2 4.0
Nominal input Cooling Standard kW 0.73 1.10
Heating Standard kW 0.92 1.20 For combination indoor units + outdoor units EER Nominal 3.42 3.09 COP Nominal 3.48 3.33 Energy Labeling Directive Cooling A B Heating B C
Annual energy consumption kWh 365 550
Indoor Units FBQ35B8V1
Cooling
capacity Standard kW 3.4
Heating
capacity Standard kW 4.0
Nominal input Cooling Standard kW 1.17
Heating Standard kW 1.22 For combination indoor units + outdoor units EER Nominal 2.91 COP Nominal 3.28 Energy Labeling Directive Cooling C Heating C
Annual energy consumption kWh 585
Indoor Units FHQ35BVV1B
Cooling
capacity MinimumStandard kWkW 1.43.4
Maximum kW 3.7
Heating
capacity MinimumStandard kWkW 1.24.0
Maximum kW 5.0
Nominal input Cooling Standard kW 1.05
Heating Standard kW 1.11 For combination indoor units + outdoor units EER Nominal 3.24 COP Nominal 3.60 Energy Labeling Directive Cooling A Heating B
1
2
• Split Sky Air • Outdoor Units
4
Casing Colour Ivory White
Dimensions Unit Height mm 550 550 550
Width mm 765 765 765 Depth mm 285 285 285 Packing Height mm 589 617 617 Width mm 882 882 882 Depth mm 363 363 363 Weight Unit kg 30 32 32 Packed Unit kg 35 38 38 Heat
Exchanger Dimensions LengthNr of Rowsmm 8281 8052 8052
Fin Pitch mm 1.4 1.4 1.4
Nr of Stages 24 24 24
Tube type Hi-Xa(7)
Fin Type Waffle fin
Treatment Anti-corrosion treatment (PE)
Fan Type Propeller
Quantity 1 1
Air Flow Rate (nominal at 230V) Cooling m³/min 36.2(H) - 25.7(L) 33.5(H) - 23.4(L) 33.5(H) - 23.4(L) Heating m³/min 32.6(H) - 30.6(L) 30.2(H) - 28.3(L) 30.2(H) - 28.3(L) Motor Quantity 1 1 1 Model D238-28 Motor Speed
(nominal) CoolingHeating rpmrpm 860(H) - 620(L)860(H) - 810(L) 860(H) - 620(L)860(H) - 810(L)
Fan Motor Output W 50 50 50
Compressor Quantity 1 1 1
Motor Model 1YC23NXD#C
Type Hermetically sealed swing compressor
Motor
Output W 600 600 600
Operation
Range Cooling Min
°CDB -10 -10 -10
Max °CDB +46 +46 +46
Heating Min °CWB -15 -15 -15
Max °CWB +20 +20 +20
Sound Level
(nominal) Cooling Sound Power dBA 61(H) 61(H) 62(H)
Sound
Pressure dBA 46(H) - 43(L) 46(H)- 43(L) 47(H) - 44(L)
Heating Sound
Pressure dBA 47(H) - 44(L) 62(H) 48(H) - 45(L)
Sound Level
(Night quiet) Sound Pressure dBA 47(H) - 44(L)
Refrigerant Type R-410A
Charge kg 0.8 1.0 1.0
Refrigerant Oil Type FVC50K
1
2
• Split Sky Air • Outdoor Units
5
connections (OD) Gas Diameter (OD) mm 9.5 9.5 9.5 Drain Diameter (OD) mm 18 18 18Piping Length Maximum m 20 20 20
Chargele ss m 10 10 Additional Refrigerant Charge kg/m 0.02/>10m Installation height difference Maximum m 15 15 15
Heat Insulation Both liquid and gas pipes Both liquid and gas pipes
Standard
Accessories ItemQuantity 1 Installation manual1 1
Item Drain plug Drain plug
Quantity 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 270CDB, 190CWB, outdoor temperature : 350CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.
2-3 ELECTRICAL SPECIFICATIONS
RXS20E2V1B RXS25E2V1B RXS35E2V1BPower Supply Name V1
Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 220-240 Current Nominal running current (RLA) Cooling (A) A 2.44 3.14 4.42 Heating (A) A 3.34 3.94 4.72
Starting current (cooling/
heating) A 3.7 4.3 5.1
Z-max List No requirements
Maximum Running Current A 3.33/4.13 4.61/4.91
Wiring
connections For Power Supply Quantity 3 3 3
For connection
1
4
• Split Sky Air • Outdoor Units
7
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FTXS20D3VMW/L RXS20E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 40 2.3 23 0.20 40 0.14 2.1 2.0 3D055006
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FTXS25D3VMW/L RXS25E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 48.5 3.0 23 0.22 40 0.14 2.8 2.7 3D055008
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
4
• Split Sky Air • Outdoor Units
8
FLXS25BAVMB RXS25E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 50 3.2 23 0.16 34 0.34 3.1 2.9 3D055010B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FDXS25EAVMB RXS25E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 54.5 3.5 23 0.16 62 0.5 3.3 3.2 3D055010B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
4
• Split Sky Air • Outdoor Units
9
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FFQ25B8V1B RXS25E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 55 3.7 23 0.16 55 0.6 3.5 3.4 3D055010B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FTXS35D3VMW/L RXS35E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 75 4.3 23 0.22 40 0.14 4.1 3.9 3D055009
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
4
• Split Sky Air • Outdoor Units
10
FLXS35BAVMB RXS35E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 82 4.8 23 0.22 34 0.38 4.6 4.4 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FDXS35EAVMB RXS35E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 78 4.7 23 0.22 62 0.5 4.5 4.3 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
4
• Split Sky Air • Outdoor Units
11
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FBQ35B8V1 RXS35E2V2B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 80 5.1 23 0.16 65 0.5 4.9 4.7 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FCQ35B8V1 RXS35E2V2B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 78 4.8 23 0.16 45 0.6 4.5 4.3 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
4
• Split Sky Air • Outdoor Units
12
FFQ35B8V1B RXS35E2V2B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 79 4.8 23 0.16 55 0.6 4.6 4.4 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
Representative unit combination Power supply Comp. OFM IFM
Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FHQ35BVV1B RXS35E2V1B 50 - 22050 - 230 50 - 240 Max. 50Hz 264V Min. 50Hz 198V 9.75 10 76 4.5 23 0.22 62 0.6 4.3 4.1 3D055011B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RHz
: Rated operating frequency (Hz)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on
the document title of your choice.
1
5
• Split Sky Air • Outdoor Units
13
Cooling 50Hz 220-240V BF 0.21
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9.4
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055032
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
14
BF 0.24
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9.4
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055033
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
15
Cooling 50Hz 220-240V BF 0.32
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9.2
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055037
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
16
BF 0.17
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 8.7
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055042
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
17
Cooling 50Hz 220-240V BF 0.24
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9
Indoor Outdoor temperature (°CWB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055487
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
18
BF 0.24
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9.7
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055034
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
19
Cooling 50Hz 220-240V BF 0.35
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 9.8
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055039
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
20
BF 0.17
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 8.7
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055043
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
21
Cooling 50Hz 220-240V BF 0.15
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 11.5
Indoor Outdoor temperature (°CWB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055493
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
22
BF 0.16
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 14
Indoor Outdoor temperature (°CWB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055491
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
23
Cooling 50Hz 220-240V BF 0.25
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 10
Indoor Outdoor temperature (°CWB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055489
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
5
• Split Sky Air • Outdoor Units
24
BF 0.20
Indoor Outdoor temperature (°CDB)
EWB EDB 20 25 30 32 35 40
(°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
Heating 50Hz 220-240V AFR 13
Indoor Outdoor temperature (°CDB)
EDB -10 -5 0 6 10
(°C) TC PI TC PI TC PI TC PI TC PI
3D055046
SYMBOLS
AFR: Air flow rate (m3/min)
BF: Bypass factor
EWB: Entering wet bulb temp. (°C)
EDB: Entering dry bulb temp. (°C)
TC: Total capacity (kW)
SHC: Sensible heating capacity (kW)
PI: Power input (kW)
NOTES
1. Capacities are based on the following conditions:
(1) Corresponding refrigerant piping length: 7.5 m
(2) Level difference: 0 m
1
6
• Split Sky Air • Outdoor Units
25
3D041800H
RXS20-35E2V1B
Minimum space for air passage Wall height on air outlet side =less than 1200
Drain outlet
(I.D.J 15.9 hose for connection)
Handle
Wiring inlet
Gas stop valve (J 12.7 CuT) Liquid stop valve (J 6.4 CuT)
Service port
Outdoor air thermistor Brand name label
4 x holes for anchor bolts (M8 or M10)
Name plate
In case of removing stop valve cover
1
6
• Split Sky Air • Outdoor Units
26
1
7
• Split Sky Air • Outdoor Units
27
3D047315D
RXS20E2V1B
Outdoor temperature thermistor Heat exchanger Propeller fan Liquid stop valve Field piping Field piping Gas stop valve
Compressor Refrigerant flow
Cooling Heating Discharge pipe thermistor Heat exchanger thermistor Muffler with filter
Motor operated valve Muffler with
filter
Outdoor unit
Muffler
Muffler
Four way valve normally: OFF Accumulator Muffler with filter 3D047316E
RXS25-35E2V1B
Outdoor temperature thermistor Heat exchanger Propeller fan Liquid stop valve Field piping Field piping Gas stop valve Compressor Refrigerant flow Cooling Heating Discharge pipe thermistor Heat exchanger thermistor Muffler with filter Motor operated valve Muffler with filter Outdoor unit Muffler Muffler
Four way valve normally: OFF
Accumulator
Muffler with filter
1
8
• Split Sky Air • Outdoor Units
28
3D041707H R : Protective earth C74,C75 C94,C95,C100 : Capacitor DB1,DB2 : Diode bridge FU1,FU2,FU3 : Fuse
IC11 : Solid state relay
IPM1 : Intelligent power module
L : Live L1 : Coil L1R : Reactor M1C : Compressor motor M1F : Fan motor MRCW,MRM10,MRM20 : Magnetic relay N : Neutral
PCB1,PCB2 : Printed circuit board
Q1L : Overload protector R1T,R2T,R3T,R12T : Thermistor S10,S11,S20 S30,S40,S70 S80,S90,S91 HC3,HC4,HL3,HN3: Connector
g
Field wiring Indoor Outdoor (outdoor) (Condenser) (discharge)SA1 : Surge arrester
V1,V2,V3 : Varistor
X1M : Terminal strip
Y1E : Electronic expansion valve coil
Y1R : Reversing solenoide valve coil
Z1C,Z2C : Ferrite core
In case of cooling
only type In case of heatpump type
NOTE
1
9
• Split Sky Air • Outdoor Units
29
4D052971C Octav e ban d soun d pressur e levelOctave band center frequency (Hz)
approximate threshold hearing for
continuous noise
NOTES
1 Measure in anechoic room
2 Operation noise differs with operation and ambient conditions.
3 The operation noise measuring method is in accordance with JISC9612
Legend 50Hz, 220-240V Location of microphone 3D052971C Octav e ban d soun d pressur e level
Octave band center frequency (Hz)
approximate threshold hearing for
continuous noise
NOTES
1 Measure in anechoic room
2 Operation noise differs with operation and ambient conditions.
3 The operation noise measuring method is in accordance with JISC9612
Legend 50Hz, 220-240V Location of microphone 4D052972C Octav e ban d soun d pressur e level
Octave band center frequency (Hz)
RXS35E2V1B (Cooling)
approximate threshold hearing for
continuous noise
NOTES
1 Measure in anechoic room
2 Operation noise differs with operation and ambient conditions.
3 The operation noise measuring method is in accordance with JISC9612
Legend 50Hz, 220-240V Location of microphone 3D052972C Octav e ban d soun d pressur e level
Octave band center frequency (Hz)
RXS35E2V1B (Heating)
approximate threshold hearing for
continuous noise
NOTES
1 Measure in anechoic room
2 Operation noise differs with operation and ambient conditions.
3 The operation noise measuring method is in accordance with JISC9612
Legend 50Hz, 220-240V
1
10
• Split Sky Air • Outdoor Units
30
3D039536J Outdoo rtemp .(°CDB) Pull-dow n period Indoor temp. (°CWB) Notes:
The graphs are based on the following conditions: + Equivalent piping length 7.5 m
+ Level difference 0 m
+ Air flow rate high
Cooling Heating Indoor temp. (°CDB) Outdoo rtemp .(°CWB) Continuou s operation Continuou s operation (-15 °CDB)