(1)

PC ATTACHMENT 3

PC Attachment 3

(2)

SCALE:

PROJECT NUMBER: 003-180212.08

SHEET NUMBER DRAWING TITLE ISSUE / REVISION

TESLA

SERVICE LITE SPRINT 25471 ARCTIC OCEAN DRIVE, LAKE FOREST,

CA 92630

06.21.19 ISSUED FOR PERMIT

06.26.19 ADDENDUM #1

www.callisonrtkl.com CallisonRTKL, Inc.

750 Brooksedge Blvd.

Westerville, Ohio 43081 phone: 614.839.4639

fax: 614.839.2222 www.mengineering.us.com

M-Engineering

AUE

ARMOUR-UNSDERFER 159 WEST 53rd STREET, 23G

NEW YORK, NY 10019 TEL: (425) 614-0949

[email protected]

07.02.19 ADDENDUM #2

07.30.19 REVISED PER COMMENTS 08.21.19 2 REVISED PER COMMENTS

1

08.27.19 ISSUED FOR CONSTRUCTION

09.06.19 CUP PACKAGE

10.18.19 REVISED CUP PACKAGE

N

INDEX OF DRAWINGS

REFERENCE SYMBOLS

FIXTURE / EQUIPMENT TYPE

ALIGN CL

#

- - - - XXX

- - - - -

-

-

-

- -

FINISH

#

ALIGN

SECTION SECTION DETAIL

COLUMN BUBBLE AND GRID

PLAN DETAIL DOOR NUMBER WALL TYPE

CEILING TYPE AND HEIGHT

ROOM NAME FINISH TAG

ELEVATION ELEVATIONS

CENTER LINE SYMBOL CUT LINE

DATUM POINT KEYNOTE

25471 ARCTIC OCEAN DRIVE, LAKE FOREST, CA 92630

TESLA CENTER LAKE FOREST

SERVICE LITE SPRINT

A0.00

COVER SHEET

AS NOTED ARCHITECTURAL

A0.00 COVER SHEET

A1.00 LABELED PHOTOGRAPHS OF THE SUBJECT SITE AND SURROUNDING PROPERTIES A1.01 SITE PLAN

A2.01 FLOOR PLAN

A4.01 EXISTING EXTERIOR ELEVATIONS

# ID X'-X" A.F.F.

ROOM

ABBREVIATIONS

TOTAL BUILDING AREA: 18,144 SF

TOTAL PROPERTY AREA: APPROX. 42,050 SF OCCUPANCY GROUP: S-1 / B

CONSTRUCTION TYPE: II-B OCCUPANCY LOAD: 89

NUMBER OF EXITS REQUIRED: B: 1 EXIT S-1: 2 EXITS SPRINKLERED: YES

FIRE ALARM: YES SEISMIC ZONE: ZONE 4

ZONING USE: LI - LIGHT INDUSTRIAL

AUTHORITY HAVING JURISDICTION: ORANGE COUNTY

BUILDING CODE: CALIFORNIA BUILDING CODE 2016 LOCAL AMENDMENTS: CITY OF LAKE FOREST

ELECTRICAL CODE: CALIFORNIA ELECTRICAL CODE 2016 PLUMBING CODE: CALIFORNIA PLUMBING CODE 2016 MECHANICAL CODE: CALIFORNIA MECHANICAL CODE 2016

ENERGY CODE: CALIFORNIA ENERGY CODE 2016

FIRE CODE: CALIFORNIA FIRE CODE 2016

GREEN BUILDING CODE: CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 MUNICIPAL CODE: LAKE FOREST MUNICIPAL CODE

CODE / PROJECT INFORMATION VICINITY MAP

JT. JOINT

LAM. LAMINATE LAV. LAVATORY LIN. LINEAR L.L. LANDLORD L.P. LOW POINT

LT. LIGHT

MAX. MAXIMUM

MDO. MEDIUM DENSITY OVERLAY MECH. MECHANICAL

MFR. MANUFACTURER MIN. MINIMUM

MISC. MISCELLANEOUS M.O. MASONRY OPENING

MTD. MOUNTED

MTL. METAL

(N) NEW

N/A NOT APPLICABLE N.I.C. NOT IN CONTRACT NOM. NOMINAL

NO. or # NUMBER N.T.S. NOT TO SCALE O OWNER - TESLA PM O.C. ON CENTER

OPNG. OPENING OPP. OPPOSITE

P.LAM. PLASTIC LAMINATE PLYWD. PLYWOOD

PR. PAIR

P.T. PRESSURE TREATED RCP REFLECTED CEILING PLAN REC. RECESSED

REV. REVISION REQ'D. REQUIRED

RM. ROOM

R.O. ROUGH OPENING S.C. SOLID CORE SCHED. SCHEDULE

SF SQUARE FEET

SIM SIMILAR

SPEC. SPECIFICATION S.S. STAINLESS STEEL

S.T.C. SOUND TRANSMISSION COEFFICIENT STD. STANDARD

STL. STEEL STOR. STORAGE STRL. STRUCTURAL SUSP. SUSPENDED SYM. SYMMETRICAL TEMP. TEMPERED THK. THICK T.O. TOP OF

T.O.C. TOP OF CONCRETE TYP. TYPICAL

U..N. UNLESS OTHERWISE NOTED U.S. UNDERSIDE

V VENDOR

VERT. VERTICAL V.I.F. VERIFY IN FIELD W.C. WATER CLOSET

WD. WOOD

W.R. WATER RESISTANT

W/ WITH

ACOUS. ACOUSTICAL

A.D.A. AMERICANS WITH DISABILITIES ACT ADJ. ADJUSTABLE

A.F.F. ABOVE FINISHED FLOOR ALUM. ALUMINUM

ALT. ALTERNATE APPROX. APPROXIMATE ARCH. ARCHITECTURAL B.A.F. BIG ASS FAN

BD. BOARD

BLDG. BUILDING BLKG. BLOCKING

BOT. BOTTOM

B.O. BOTTOM OF CAB. CABINET CLG. CEILING

CL. CLOSET

CLR. CLEAR

COL. COLUMN

CONC. CONCRETE CONSTR. CONSTRUCTION CONT. CONTINUOUS

CTR. CENTER

DBL. DOUBLE

DIA. DIAMETER DIM. DIMENSION

DN. DOWN

DWG. DRAWING (E) EXISTING

EA. EACH

EL. ELEVATION ELEC. ELECTRICAL EMER. EMERGENCY

EQ. EQUAL

EQUIP. EQUIPMENT EXT. EXTERIOR F.A. FIRE ALARM F.D. FLOAT DIMENSION

F.E.F. FIRE EXTINGUISHER CABINET FIN. FINISH

F.H.C. FIRE HOSE CABINET

FLR. FLOOR

FLASH. FLASHING FLOUR. FLUORESCENT F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUDS

F.R.T. FIRE RETARDANT TREATED

GA. GAUGE

GC. GENERAL CONTRACTOR

GYP. GYPSUM

H.C. HOLLOW CORE HDCP. HANDICAP HDW. HARDWARE

HT. HEIGHT

HORIZ. HORIZONTAL H.P. HIGH POINT

HPC. HIGH POWER CONNECTOR

HR. HOUR

IN. INCH

INSUL. INSULATION INT. INTERIOR JST. JOIST

PROJECT SCOPE / NOTES

USE PERMIT ("UP), A REQUEST FOR AUTOMOBILE RETAIL SALES OF TESLA VEHICLE IN CONJUNCTION WITH AN EXISTING AUTO REPAIR SERVICE FACILITY IN AN EXISTING INDUSTRIAL BUILDING.

ALL ENERGY PRODUCTS, RELATED PARTS, ACCESSORIES, AND MERCHANDISE

PROPOSED TO BE SOLD ON SITE WILL BE DONE DIGITALLY VIA ONLINE ORDERING FOR FUTURE DELIVERY. ONLY A LIMITED INVENTORY OF ENERGY PRODUCTS, RELATED PARTS, ACCESSORIES, AND MERCHANDISE ARE PROPOSED TO BE SOLD ON SITE. TESLA INTENDS TO STORE A LIMITED AMOUNT OF MISC. APPAREL, CHARGING, AND VEHICLE

ACCESSORIES ON SITE. THIS INCLUDES ITEMS SUCH AS CHARGING ADAPTERS, FLOOR MATS, AND LICENSE PLATE FRAME. A DEDICATED STORAGE AREA FOR THESE PRODUCTS IS INDICATED ON PLAN WITH SQUARE FOOTAGE ON SHEET A2.01.

TOTAL ADDITION OF (3) NEW PARKING SPACES AT THE EXTERIOR, AND (3) ADDITIONAL PARKING SPACES TO BE USED IN THE INTERIOR OF THE BUILDING.

PROJECT SITE

25471 ARCTIC OCEAN DR.

LAKE FOREST CA 92630

XX X

ARCTIC OCEAN DR.

PROJECT DIRECTORY

TENANT

TESLA MOTORS 901 PAGE AVENUE FREMONT, CA 94538 DANIEL LEE

ARCHITECTURAL MANAGER E: [email protected]

ARCHITECT OF RECORD

CALLISONRTKL INC.

233 BROADWAY, 16TH FLOOR NEW YORK, NY 10279

YOUNG HOON PARK T: +1 212 354 9240 F: +1 212 354 9253

E: [email protected]

BUKEWIHGE PROPERTIES 444 E. GARDENA BLVD.

GARDENA, CA 90248 BOB JOHNSON T: +1 949 633 0623

LANDLORD

(3)

FE

FE

NO PARKING RAMP UP

25471 ARCTIC OCEAN DRIVE 18,144 GROSS S.F.

ARCTIC OCEAN DRIVE

SCALE:

1/16" = 1'-0"

SITE PLAN 1

N

A1.00

LABELED

PHOTOGRAPHS OF THE SUBJECT SITE AND

SURROUNDING PROPERTIES

AS NOTED SCALE:

PROJECT NUMBER: 003-180212.08

SHEET NUMBER DRAWING TITLE ISSUE / REVISION

TESLA

SERVICE LITE SPRINT 25471 ARCTIC OCEAN DRIVE, LAKE FOREST,

CA 92630

06.21.19 ISSUED FOR PERMIT

06.26.19 ADDENDUM #1

www.callisonrtkl.com CallisonRTKL, Inc.

750 Brooksedge Blvd.

Westerville, Ohio 43081 phone: 614.839.4639

fax: 614.839.2222 www.mengineering.us.com

M-Engineering

AUE

ARMOUR-UNSDERFER 159 WEST 53rd STREET, 23G

NEW YORK, NY 10019 TEL: (425) 614-0949

[email protected]

07.02.19 ADDENDUM #2

07.30.19 REVISED PER COMMENTS 08.21.19 2 REVISED PER COMMENTS

1

08.27.19 ISSUED FOR CONSTRUCTION

09.06.19 CUP PACKAGE

10.18.19 REVISED CUP PACKAGE

A B

C

SCALE:

3/32" = 1'-0"

LABELED PHOTO 2

C B A

D E F

D E

F

(4)

FE

FE

NO PARKING

S (E) A-V

S (E) (E)

A (E)

S (E)

S (E) S

(E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E)

S (E) S (E) S (E) S (E) S (E) S (E) S (E) S (E) S (E) S (E) S

(N)

TEST DRIVE VEHICLES

(E)

TEST DRIVE VEHICLES

(E)

TEST DRIVE VEHICLES

(E)

S (N)

S (N)

S (E)

S

(N) (E) PARKING SPACE TO BE UNUSED

/ REMOVED

S (E)

1

23'-6" V.I.F.

3 4

2

6

TYP 7

RAMP UP 64'-0" TRAVEL DISTANCE

18'-8" TRAVEL DISTANCE

8

9 1

10

1

1

1 11

4

5

5

53'-2 1/2" V.I.F.

6

6

24'-6"

TYP,14

18'-0" TYP.

181'-10" V.I.F.

52'-6 1/2" V.I.F.48'-5 1/2" V.I.F.

41'-0 1/2" V.I.F. 99'-6 1/2" V.I.F.

27'-8" V.I.F.

44'-10" V.I.F.

12'-11" V.I.F.

18'-6"

25471 ARCTIC OCEAN DRIVE 18,144 GROSS S.F.

ARCTIC OCEAN DRIVE 12 12

13 13

9'-0" TYP.

17'-3"

38'-10"

15 TYP.

TYP.15

TYP.15 21'-11"

SETBACK

16'-0" SETBACK

52'-10 1/2"

SETBACK

64'-8" SETBACK 16

TYP.17

17TYP.

18'-0"

11'-0"

9'-0"

18'-0"

9'-0" 9'-0"

6'-3 1/2"

3'-10"

12'-1 1/2"

SCALE:

1/16" = 1'-0"

SITE PLAN 1

PARKING CALCULATIONS

(E) LANDSCAPE AREA

PROPERTY LINE

(E) ACCESSIBLE ROUTE. 4'-0" WIDE MINIMUM, 5'-0" WIDE AT DOORWAYS. 4" WHITE PAINTED STRIPING, SPACED AT 3'-0"' ON CENTER, AT 30 DEGREE ANGLE.

(E) STANDARD PARKING STALL

(E) ELECTRIC CAR CHARGING STALL

(E) ACCESSIBLE PARKING STALL

(E) ACCESSIBLE VAN PARKING STALL

(E) WALL CONNECTOR AND DISCONNECT

1 PROPERTY LINE

LEGEND

KEY NOTES

ACCESSIBLE PATH OF TRAVEL

N

LAKE FOREST MUNICIPAL CODE, CHAPTER 9.168.070 OFF-STREET PARKING REQUIREMENTS GROUP S-1 (AUTOMOBILE REPAIR SHOP AND ANCILLARY): 1 PARKING STALL PER 400 S.F.

TOTAL REQUIRED PARKING STALLS: 18,144 GROSS S.F. / 400 = 45 PARKING STALLS REQUIRED.

TOTAL PROVIDED PARKING STALLS: 48 PARKING STALLS

REQUIRED ACCESSIBLE PARKING STALLS: 2 PARKING STALLS (1 ACCESSIBLE VAN) PROVIDED ACCESSIBLE PARKING STALLS: 2 PARKING STALLS (1 ACCESSIBLE VAN)

PROPERTY SET BACK

A1.01

SITE PLAN

AS NOTED SCALE:

PROJECT NUMBER: 003-180212.08

SHEET NUMBER DRAWING TITLE ISSUE / REVISION

TESLA

SERVICE LITE SPRINT 25471 ARCTIC OCEAN DRIVE, LAKE FOREST,

CA 92630

06.21.19 ISSUED FOR PERMIT

06.26.19 ADDENDUM #1

www.callisonrtkl.com CallisonRTKL, Inc.

750 Brooksedge Blvd.

Westerville, Ohio 43081 phone: 614.839.4639

fax: 614.839.2222 www.mengineering.us.com

M-Engineering

AUE

ARMOUR-UNSDERFER 159 WEST 53rd STREET, 23G

NEW YORK, NY 10019 TEL: (425) 614-0949

[email protected]

07.02.19 ADDENDUM #2

07.30.19 REVISED PER COMMENTS 08.21.19 2 REVISED PER COMMENTS

1

08.27.19 ISSUED FOR CONSTRUCTION

09.06.19 CUP PACKAGE

10.18.19 REVISED CUP PACKAGE 2 (E) WATER METER

3 (E) SIAMESE CONNECTION 4 (E) FIRE HYDRANT

5

6 (E) EGRESS DOOR

7 (E) POST LIGHTING 8 (E) SIGN

9 (E) TRASH ENCLOSURE 10 (E) MANHOLE

11 (E) SLIDING GATE

14

(E) GUARD RAIL

REQUIRED PROVIDED

PARKING STALLS 43 46

ACCESSIBLE 1 1

VAN ACCESSIBLE 1 1

TOTAL 45 48

12 (E) ACCESSIBLE SYMBOL

13 (E) ACCESSIBLE PARKING SIGN

S E A A-V

15 (E) HAIRPIN STRIPING

16 (E) DETECTABLE WARNING TRUNCATED DOME PAD

NOTE: NO MODIFICATION TO ANY EXISTING PLANTING AREA.

17 (N) PARKING STRIPING (E) WALL CONNECTOR

(5)

WHEEL BALANCER S-130

TIRE CHANGER

S-131

FE

FE

F101

F400 F400

F400

F400

F940

M602E131 COFFEEMAKERE142 WATER DISP.

COUNTER

STORAGE STORAGE

TV4

DATA RACK

F940

E120 MICROWAVE

(E) ELECTRICAL ROOM 106 SF

(E) AUTOMOBILE REPAIR AREA 12,443 SF

(E) PARTS & STORAGE 580 SF

(E) ACCESSIBLE

UNISEX TOILET - EMPLOYEE 61 SF

(E) JANITOR'S CLOSET

61 SF

(E) MEN'S TOILET CUSTOMER/EMPLOYEE 86 SF

(E) SERVICE OFFICE 376 SF

(E) CUSTOMER LOBBY AREA 298 SF

(E) IT ROOM 87 SF

(E) SERVICE OFFICE 139 SF

(E) SERVICE OFFICE 166 SF

(E) SERVICE OFFICE 188 SF

(E) SERVICE OFFICE 100 SF

(E) STORAGE CLOSET 155 SF

(E) STORAGE 207 SF

(E) SALES OFFICE 114 SF

(E) CUSTOMER LOBBY AREA 614 SF

(E) ACCESSIBLE UNISEX TOILET CUSTOMER/EMPLOYEE

67 SF

(E) SERVICE OFFICE 828 SF

(E) STORAGE CLOSET 115 SF

(E) EMPLOYEE BREAKROOM 254 SF

S (N) S (N)

(E) SALES OFFICE 87 SF

S (N)

SCALE:

PROJECT NUMBER: 003-180212.08

SHEET NUMBER DRAWING TITLE ISSUE / REVISION

TESLA

SERVICE LITE SPRINT 25471 ARCTIC OCEAN DRIVE, LAKE FOREST,

CA 92630

06.21.19 ISSUED FOR PERMIT

06.26.19 ADDENDUM #1

www.callisonrtkl.com CallisonRTKL, Inc.

750 Brooksedge Blvd.

Westerville, Ohio 43081 phone: 614.839.4639

fax: 614.839.2222 www.mengineering.us.com

M-Engineering

AUE

ARMOUR-UNSDERFER 159 WEST 53rd STREET, 23G

NEW YORK, NY 10019 TEL: (425) 614-0949

[email protected]

07.02.19 ADDENDUM #2

07.30.19 REVISED PER COMMENTS 08.21.19 2 REVISED PER COMMENTS

1

08.27.19 ISSUED FOR CONSTRUCTION

09.06.19 CUP PACKAGE

10.18.19 REVISED CUP PACKAGE

SCALE:

3/32" = 1'-0"

FLOOR PLAN 1

(E) CONSTRUCTION TO REMAIN.

(E) 14/50 RECEPTACLE

(E) WALL CONNECTOR AND DISCONNECT 1

2

3

4

LEGEND KEY NOTES

5

6

7

8

9

A2.01

FLOOR PLAN

AS NOTED (E) EXTERIOR SYSTEM

(E) OVERHEAD DOOR

(E) EGRESS DOOR

(E) ELECTRICAL PANEL

1 TYP.

3 TYP.

2 TYP.

2 TYP.

2 TYP.

4 TYP.

(E) FIRE EXTINGUISHER, SERVICE IF REQUIRED.

3 TYP.

(E) SECURITY CAMERA

6 TYP.

TYP. 5

TYP. 6

2 TYP.

2 A4.01

1 A4.01 7

(E) MOP SINK

N

TYP. 5 4

A4.01

3 A4.01 (N) PROPOSED LOCATION FOR INTERIOR PARKING

8 9

9 TESLA'S ENERGY PRODUCTS, RELATED PARTS, ACCESSORIES, AND MERCHANDISE ARE TO

BE SOLD ON SITE AND WILL BE STORED IN 115 SF (E) STORAGE CLOSET. RETAILS SALES AREA ARE NO MORE THAN 15% OF THE FLOOR AREA.

8 8

(6)

25431

T.O. FINISH FLOOR 0'-0"

T.O. (E) PARAPET 26'-0" A.F.F. V.I.F.

(E) OVERHEAD DOOR (E) ILLUMINATED METAL"TESLA" SIGN

(E) EGRESS DOOR

T.O. FINISH FLOOR 0'-0"

T.O. (E) PARAPET 26'-0" A.F.F. V.I.F.

T.O. OPENING 12'-0" A.F.F. V.I.F.

T.O. OPENING 7'-0" A.F.F. V.I.F.

(E) WINDOWS

T.O. FINISH FLOOR 0'-0"

T.O. (E) PARAPET 26'-0" A.F.F. V.I.F.

T.O. FINISH FLOOR 0'-0"

T.O. (E) PARAPET 26'-0" A.F.F. V.I.F.

T.O. OPENING 12'-0" A.F.F. V.I.F.

T.O. OPENING 7'-0" A.F.F. V.I.F.

(E) OVERHEAD DOOR (E) OVERHEAD DOOR (E) OVERHEAD DOOR

(E) EGRESS DOOR (E) EGRESS DOOR (E) WINDOWS

(E) ILLUMINATED METAL"TESLA" SIGN

(E) WALL CONNECTOR, TYP.

(E) LADDER TO ROOF

SCALE:

PROJECT NUMBER: 003-180212.08

SHEET NUMBER DRAWING TITLE ISSUE / REVISION

TESLA

SERVICE LITE SPRINT 25471 ARCTIC OCEAN DRIVE, LAKE FOREST,

CA 92630

06.21.19 ISSUED FOR PERMIT

06.26.19 ADDENDUM #1

www.callisonrtkl.com CallisonRTKL, Inc.

750 Brooksedge Blvd.

Westerville, Ohio 43081 phone: 614.839.4639

fax: 614.839.2222 www.mengineering.us.com

M-Engineering

AUE

ARMOUR-UNSDERFER 159 WEST 53rd STREET, 23G

NEW YORK, NY 10019 TEL: (425) 614-0949

[email protected]

07.02.19 ADDENDUM #2

07.30.19 REVISED PER COMMENTS 08.21.19 2 REVISED PER COMMENTS

1

08.27.19 ISSUED FOR CONSTRUCTION

09.06.19 CUP PACKAGE

10.18.19 REVISED CUP PACKAGE

SCALE:

1/8" = 1'-0"

SOUTH EXTERIOR ELEVATION 1

SCALE:

1/8" = 1'-0"

NORTH EXTERIOR ELEVATION 2

SCALE:

1/8" = 1'-0"

EAST EXTERIOR ELEVATION 4

A4.01

EXISTING EXTERIOR ELEVATIONS

AS NOTED SCALE:

1/8" = 1'-0"

WEST EXTERIOR ELEVATION 3

References

Related documents

Where off-street parking is provided on a lot other than the lot containing the building or use for which the parking is required, the owner of the lot upon which the parking

3 4 Start Select Measurement Method (Section 7.9) Set Hardware Scope (Section 7.4) Perform OS power consumption assessment (Section 7.5) Perform Application only power

If the director finds that a portion of the floor area not less than a contiguous one hundred square feet in a retail store will be used exclusively for storage of merchandise

Does not required to park in residential parking requirements for los angeles municipal code or garages and other tier of california state noise ordinances.. Some exams are open

Despite any other provision in this chapter, where parking machines and/or location ID signs have been erected under the authority of § 910-3, no person shall park a vehicle in

• A minimum of 2 off-street parking spaces are required per unit AND visitor parking must be provided in a paved area within the development site at a rate of 50% of the

B.2.6 All approved off-street vehicle parking, loading and unloading spaces, and bicycle parking spaces shall be provided in accordance with the relevant requirements of the

The City Planning Commission may permit an increase in the number of spaces in an #accessory# off-street parking facility existing prior to May 8, 2013, as listed in paragraph (a)