satin or frosted acrylic lens (up to 12' lens sections)
RECESSED T-BAR
S P E C I F I C A T I O N S
Optics4.0
O P T I C S6.0
Fixture Lengths3.0
Mounting Options L A M P C O N F I G U R AT I O N S M O U N T I N G O P T I O N S T-Bar (Mounting Option: TB)Screw Slot T-Bar
(Mounting Option: ST)
Tegular
(Mounting Option: TG)
* Staggered not available with lamp config option: (3) three lamps
BX cable connector (by other)
T-bar ceiling
fixture (lay-in version)
i
i
i
O P T I C S P O S I T I O N Flush (Optics Option: FL)5"
4"
SATIN LENS FROSTED LENS(acrylic snap-in lens)
satin: 68% transmissive frosted: 85% transmissive LOUVERS
(semi-spec. parabolic louver/ white louver)
BLANK with MR16
(9'' blank aluminum sections)
* See Beam 6 MR16 Spec sheet.
ASYMMETRIC
(asymmetric reflector)
* See Beam 6 Asymmetric Spec sheet. ceiling tile T-Bar Bracket support wire (by other) T-Bar Regressed (Optics Option: RG) +3/ 4"
5"
4"
by Armstrong by USG by Armstrong by USG compatible compatible with 6" between T-Bars 1xT5 / T5HO (T5-1) 1xT8 (T8-1)End to End Lamping
1xT5 / T5HO (T5-1S)
1xT8 (T8-1S)
Staggered Lamping
End to End Lamping
2xT5 / T5HO (T5-2)
Staggered Lamping
2xT5 / T5HO (T5-2S)
Screw Slot T-Bar Screw Slot T-Bar Bracket ceiling tile support wire (by other) T-Bar Screw Slot T-Bar Bracket Tegular ceiling panel support wire (by other) * 6" spacing betweenT-Bars
4
3/4"
Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)
Interior Brackets Die Formed Sheet Steel (18 gauge)
Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal) Lenses Extruded Acrylic (0.070'' nominal)
Satin: 68% trans. Frosted: 85% trans. T-Bar Bracket Die Formed Sheet Steel (16 gauge) Screw Slot T-Bar Bracket Die Formed Sheet Steel (16 gauge)
C O N S T RU C T I O N
Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg. (4' fixture)
Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T5, T5HO, T8
Voltage 120, 277, 347, UNV
Daylight Harvesting / Occupancy Sensors Available Certification UL listed to U.S. & Canadian standards
P R O D U C T O R D E R I N G C O D E
E L E C T R I C A L R E C E S S E D F E AT U R E S * Fits within 2'x4' grid for T5, T5HO, and T8
Armstrong by USG
* T8 lamps must be used with optics position option: regressed
compatible
5"
4"
RECESSED T-BAR
S P E C I F I C A T I O N S
FL flush RG regressed (satin/frosted lens only)S satin lens
F frosted lens
PL semi spec para. louver
SB white louver
A asymmetric reflector
WW wall wash
SW satin wall wash
W C
white custom
optics positionoptics config lamp other
product id length/ft lamp MR16 voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERS rapid start
D dimming
(specify details) TBST Screw Slot T-barT-bar
TG Tegular C custom description if required T5 T5HO T8 (regressed only) 1 one circuit 2 two circuits +E + emergency +M + MR16 B# batt. pack (quan./4' sections)
F fuse (one per ballast)
CP chicago plenum
E end mount power feed 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered
7.9
Installation Instructions3.0
Mounting Options6.0
Fixture Lengthsi
4.0
OpticsW
FL
5
T5
1
M0
120
E
1
TB
S
B6R recessedB6R
Asymmetric: See Beam 6 Asymmetric Spec sheet.
* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.
MR16: See Beam 6 MR16 Spec sheet. M# MR16 quantity
*(add 9" per lamp)
Corners: See Beam 6 Corner Spec sheet.
120 UNV 277 347
5.0
Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controlsSensors are only possible with optics position: (FL) flush
Wall Wash: See Beam 6 Wall Wash Spec sheet.
Staggered not available with 3 lamps.
i
i
i
CONTROLS SENSORi
by Armstrong by USG compatiblei
D E TA I L E D I N F O R M AT I O N* Staggered not available with lamp config option: (3) three lamps
4.0
Opticsi
i
3.1
Mounting Options6.0
Fixture Lengthsi
RECESSED DRYWALL
S P E C I F I C A T I O N S
O P T I C S P O S I T I O N Flush (Optics Option: FL)5"
4"
Regressed (Optics Option: RG) +3/ 4"5"
4"
satin or frosted acrylic lens (up to 12' lens sections)
drywall ceiling ¼-20 threaded rod (by other) fixture (flanged version) BX cable connector (by other) Flanged (Mounting Option: DF) slip-through bracket (supplied) flange (supplied) Slip-Through Bracket (Mounting Option: DB) Flangeless (Mounting Option: D) Spackle Flange (Mounting Option: DS) drywall finishing plaster drywall edge trim (by other) drywall ¼" threaded rod (by other) finishing spackle drywall spackle flange (supplied) drywall ¼" threaded rod (by other) drywall anchor flange (supplied) drywall ¼" threaded rod (by other)
4
3/4"
O P T I C S BLANK with MR16(9'' blank aluminum sections)
* See Beam6 MR16 Spec sheet.
ASYMMETRIC
(asymmetric reflector)
* See Beam6 Asymmetric Spec sheet. SATIN LENS
FROSTED LENS
(acrylic snap-in lens)
satin: 68% transmissive frosted: 85% transmissive M O U N T I N G L A M P C O N F I G U R AT I O N S 1xT5 / T5HO (T5-1) 1xT8 (T8-1)
End to End Lamping
1xT5 / T5HO (T5-1S)
1xT8 (T8-1S)
Staggered Lamping Staggered Lamping
2xT5 / T5HO (T5-2S)
2xT8 (T8-2S)
* See Beam 6 Vertical Recessed Spec sheet. Beam 6 Vertical Recessed
LOUVERS
(semi-spec. parabolic louver/ white louver)
End to End Lamping
2xT5 / T5HO (T5-2)
2xT8 (T8-2)
3xT5 / T5HO (T5-3)
FL flush
RG regressed (satin/frosted lens only)
S satin lens
F frosted lens
PL semi spec para. louver
SB white louver
A asymmetric reflector
WW wall wash
SW satin wall wash
optics optics position
lamp
config other
product id length/ft lamp MR16 voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERSrapid start
D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C white custom
W
FL
8
T5 1S
M0
120
E
1
S
DF
DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)DSdrywall spackle flange
B6R recessed
B6R
7.5−7.8
Installation Instructions3.1
Mounting Options6.0
Fixture Lengths4.0
Optics 120 UNV 277 3475.0
Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controlsSensors are only possible with optics position: (FL) flush
Asymmetric: See Beam 6 Asymmetric Spec sheet.
Corners: See Beam 6 Corner Spec sheet. Vertical: See Beam 6 Vertical Recessed Spec sheet.
* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.
MR16: See Beam 6 MR16 Spec sheet.
M# MR16 quantity * (add 9" per lamp)
Wall Wash: See Beam 6 Wall Wash Spec sheet.
i
i
i
i
i
B# batt. pack (quan./4' sections)F fuse (one per ballast)
CP chicago plenum
E end mount power feed
Staggered not available with 3 lamps.
CONTROLS SENSOR
P R O D U C T O R D E R I N G C O D E
Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)
Interior Brackets Die Formed Sheet Steel (18 gauge)
Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal) Lenses Extruded Acrylic (0.070'' nominal)
Satin: 68% trans. Frosted: 85% trans. Slip-Through Bracket Die Formed Sheet Steel (18 gauge)
Spackle Flange Die Formed Perforated Sheet Steel (20 gauge) Flange Extruded Aluminum (0.075'' nominal)
visible flange width: 9/
16"
C O N S T RU C T I O N
Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg (4' fixture)
E L E C T R I C A L
Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T5, T5HO, T8
Voltage 120, 277, 347, UNV
Daylight Harvesting / Occupancy Sensors Available Certification UL listed to U.S. & Canadian standards
5"
4"
RECESSED DRYWALL
S P E C I F I C A T I O N S
Drywall Spackle Flange (Mounting Option: DS) Drywall Flanged (Mounting Option: DF) 5/8" 5/8" 5/8" 5/8" stud drywall mounting bracket (supplied) flange (supplied) 5" 5" 31/ 2" 31/2"
* Beam 6 Vertical Recessed Mount with mounting option: drywall flanged (DF)
mounting bracket (supplied) stud finishing plaster drywall spackle flange (supplied)
VERTICAL WALL RECESSED
S P E C I F I C A T I O N S
T5 - 4' (47
9/16")
T8 - 4' (49
1/4")
F R O N T V I E W V E RT I C A L R E C E S S E D M O U N T I N G O P T I O N S
* Beam 6 Vertical Recessed Mounting Options shown with optics position: flush (FL)
NOMINAL 4' FIXTURE LENGTH
FL flush
RG regressed (satin/frosted lens only)
B# batt. pack (quan./4' sections)
F fuse (one per ballast)
CP chicago plenum
E end mount power feed
S satin lens
F frosted lens
PL semi spec para. louver
SB white louver optics optics position lamp config other
product id length/ft lamp MR16 voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERSrapid start
D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C customwhite
W
FL
8
T5 1S
M0
120
E
1
S
DF
DF drywall flangedDSdrywall spackle flange
B6R recessed +V vertical
B6RV
3.4
Mounting Options6.0
Fixture Lengths4.0
Optics 120 UNV 277 347* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.
MR16: See Beam 6 MR16 Spec sheet. M# MR16 quantity
* (add 9" per lamp)
i
i
i
Staggered not available with 3 lamps.
C O N S T RU C T I O N
Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T8, T5, T5HO
Voltage 120, 277, 347, UNV
Certification UL listed to U.S. & Canadian standards E L E C T R I C A L
P R O D U C T O R D E R I N G C O D E
Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)
Interior Brackets Die Formed Sheet Steel (18 gauge)
Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal)
Lenses Extruded Acrylic (0.070'' nominal) Satin: 68% trans. Frosted: 85% trans. Slip-Through Bracket Die Formed Sheet Steel (18 gauge)
Spackle Flange Die Formed Perforated Sheet Steel (20 gauge) Flange Extruded Aluminum (0.075'' nominal)
visible flange width: 9/
16"
Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg (4' fixture)
VERTICAL WALL RECESSED
S P E C I F I C A T I O N S
5"
4"
B# batt. pack (quan./4' sections)
F fuse (one per ballast)
CP chicago plenum
E end mount power feed
A asymmetric reflector
B6R recessed
optics config lamp other
product id length/ft lamp voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERS rapid start
D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 W white C custom 2 3 4 5 6 8 12 S# system 1 * one lamp
W
B6R
A
4
T5
1
120
E
1
DF
120 UNV 277 347 DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)DSdrywall spackle flange
TB T-Bar
ST Screw Slot T-Bar
7.5-7.8
Installation Instructions4.0
Opticsi
i
* Asymmetric is offered for End-to-End 1 T5/T5HO/T8 lamping only.snap in Asymmetric reflector rests flush with ceiling plane.
4" NOMINAL 4' LENGTH 46 7/16" 41/4" 5" 4" 4" Drywall (Mounting Option: D) T-Bar (Mounting Option: TB) P R O D U C T O R D E R I N G C O D E
Asymmetric Reflector Extruded Aluminum (0.075'' nominal)
C O N S T RU C T I O N
L A M P C O N F I G U R AT I O N
* See Beam 6 Recessed T-Bar or Drywall Spec sheets for further electrical and construction information.
M O U N T I N G O P T I O N S S E C T I O N 1 T5/T5HO/T8 (Code: T5-1, T5HO-1 or T8-1)
ASYMMETRIC RECESSED
S P E C I F I C A T I O N S
5"
4"
B# batt. pack (quan./4' sections)
F fuse (one per ballast)
CP chicago plenum E end mount
power feed
WW wall wash
SW satin wall wash
B6R recessed
optics config lamp other
product id length/ft lamp voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERS rapid start
D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 W white C custom 2 3 4 5 6 8 12 S# system 1 * one lamp
W
B6R
WW
4
T5
1
120
E
1
DF
120 UNV 277 347 DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)DSdrywall spackle flange
TB T-Bar
ST Screw Slot T-Bar
TG Tegular
i
i
i
3.0
Mounting Options7.5-7.8
Installation Instructions4.0
OpticsCorners: See Beam 6 Corner Spec sheet.
* Wall Wash is offered for End-to-End 1 T5/T5HO/T8 lamping only.
4"
NOMINAL 4' LENGTH
46 7/16"
snap in Wall Wash reflector rests flush with ceiling plane.
reflector extends 3/4"
below ceiling plane
41/4" 5" 4" Drywall (Mounting Option: D) T-Bar (Mounting Option: TB) S E C T I O N M O U N T I N G O P T I O N S P R O D U C T O R D E R I N G C O D E L A M P C O N F I G U R AT I O N C O N S T RU C T I O N
Wall Wash Reflector Extruded Aluminum (0.075'' nominal) * See Beam 6 Recessed T-Bar or Drywall Spec sheets
for further electrical and construction information.
1 T5/T5HO/T8
(Code: T5-1, T5HO-1 or T8-1)
5"
4"
WALL WASH RECESSED
S P E C I F I C A T I O N S
FL flush
RG regressed (satin/frosted lens only)
S satin lens
F frosted lens
PL semi spec para. louver
SB white solid louver
optics optics position
lamp
config other
product id length/ft lamp MR16 voltage ballast
sample or dering options custom mounting finish circuit E electronic
ERS rapid start
D dimming (specify details) C custom description if required T5 T5HO T8 (regressed in T-Bar) 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C white custom
W
FL
4
0
M4
120
E
1M
DF
DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)DSdrywall spackle flange
TB T-bar
ST Screw Slot T-bar
TG Tegular B6R recessed +V vertical
B6R
7.1−7.10
Installation Instructions3.0
6.0
Fixture Lengths4.0
Optics 120 UNV 277 3475.0
Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controlsSensors are only possible with optics position: (FL) flush
Corners: See Beam 6 Corner Spec sheet.
* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.
M# MR16 quantity *(add 9" per lamp)
i
i
i
i
i
B# batt. pack (quan./4' sections)
F fuse (one per ballast)
CP chicago plenum
E end mount power feed
Staggered not available with 3 lamps.
9" variable +3/4" 5" 4" 43/ 4" 5" 4" Flush (Optics Option: FL) Regressed (Optics Option: RG) * 6" spacing betweenT-Bars
Blank Extruded Aluminum (0.075'' nominal) MR16 Halogens 2.0'' diameter (35W / 50W)
*MR16 Halogen lamps can be aimed up to 35° from vertical. P R O D U C T O R D E R I N G C O D E O P T I C S P O S I T I O N S M R 1 6 C O N F I G U R AT I O N S C O N S T RU C T I O N Quantity
For every 4' fluorescent lamp section, there may be up to a maximum of 4 x MR16 lamps. Spacing
Each MR16 is placed centered on a blank section 9'' in length. For a series of MR16's within a given section length,
they will be spaced evenly on a longer blank section. * Custom spacing may be available on special request.
Between fluorescent lamps sections Several in a long blank section
MR16
S P E C I F I C A T I O N S
4"
Pass through wires for a quick connection. 71/ 2" 71/ 2" 107/ 8" 71/ 2" 107/8" 107/ 8" Wall to Ceiling 90 degree corner (Corner Option: WLC) 90 degree Corner (Corner Option: C/LC) 90˚ Corner (Corner Option: C) T Corner (Corner Option: T) X Corner (Corner Option: X) C 90 degree T T junction X X junction LC lit 90 degree WLC wall to ceiling lit 90 degree sample options corner
C
CNR
B6R
product id W white C custom finishW
The corner modules are an assembly of welded aluminum extrusions. For added rigidity and a secure joining, the assembly uses an internal dieformed sheet steel to align the corners and linear sections of the system. Corner Specification Tip:
* Provide sketches illustrating corner types and locations required. In addition to linear runs, the Beam 6 fixture can be specified
with corners: 90°, T or X sections. * Dimensions below vary for Lit Corners.
B E A M 6 C O R N E R O R D E R I N G C O D E C O R N E R C O N F I G U R AT I O N S
B E A M C O R N E R F E AT U R E S
General Assembly Mitered Aluminum extrusion Side Profile Extruded Aluminum (0.100'' nominal) Blank Cover Extrusion Extruded Aluminum (0.080'' nominal) Interior Brackets Die Formed Sheet Steel (16 gauge) Finish Anodized, Powder Coated, Lacquered Certification UL listed to U.S. & Canadian standards C O N S T RU C T I O N
R E Q U I R E M E N T S Corners are to be ordered in parallel with their corresponding linear sections. Please specify each corner style required with a seperate code (see code below). Mounting points are to be situated on attached linear sections rather than on corners.
All systems requiring corner units must be specified as such at the time of order. Existing linear systems or fixtures cannot have corners added at a later date.