• No results found

RECESSED T-BAR SPECIFICATIONS

N/A
N/A
Protected

Academic year: 2021

Share "RECESSED T-BAR SPECIFICATIONS"

Copied!
10
0
0

Loading.... (view fulltext now)

Full text

(1)

satin or frosted acrylic lens (up to 12' lens sections)

RECESSED T-BAR

S P E C I F I C A T I O N S

Optics

4.0

O P T I C S

6.0

Fixture Lengths

3.0

Mounting Options L A M P C O N F I G U R AT I O N S M O U N T I N G O P T I O N S T-Bar (Mounting Option: TB)

Screw Slot T-Bar

(Mounting Option: ST)

Tegular

(Mounting Option: TG)

* Staggered not available with lamp config option: (3) three lamps

BX cable connector (by other)

T-bar ceiling

fixture (lay-in version)

i

i

i

O P T I C S P O S I T I O N Flush (Optics Option: FL)

5"

4"

SATIN LENS FROSTED LENS

(acrylic snap-in lens)

satin: 68% transmissive frosted: 85% transmissive LOUVERS

(semi-spec. parabolic louver/ white louver)

BLANK with MR16

(9'' blank aluminum sections)

* See Beam 6 MR16 Spec sheet.

ASYMMETRIC

(asymmetric reflector)

* See Beam 6 Asymmetric Spec sheet. ceiling tile T-Bar Bracket support wire (by other) T-Bar Regressed (Optics Option: RG) +3/ 4"

5"

4"

by Armstrong by USG by Armstrong by USG compatible compatible with 6" between T-Bars 1xT5 / T5HO (T5-1) 1xT8 (T8-1)

End to End Lamping

1xT5 / T5HO (T5-1S)

1xT8 (T8-1S)

Staggered Lamping

End to End Lamping

2xT5 / T5HO (T5-2)

Staggered Lamping

2xT5 / T5HO (T5-2S)

Screw Slot T-Bar Screw Slot T-Bar Bracket ceiling tile support wire (by other) T-Bar Screw Slot T-Bar Bracket Tegular ceiling panel support wire (by other) * 6" spacing betweenT-Bars

4

3/4

"

(2)

Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)

Interior Brackets Die Formed Sheet Steel (18 gauge)

Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal) Lenses Extruded Acrylic (0.070'' nominal)

Satin: 68% trans. Frosted: 85% trans. T-Bar Bracket Die Formed Sheet Steel (16 gauge) Screw Slot T-Bar Bracket Die Formed Sheet Steel (16 gauge)

C O N S T RU C T I O N

Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg. (4' fixture)

Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T5, T5HO, T8

Voltage 120, 277, 347, UNV

Daylight Harvesting / Occupancy Sensors Available Certification UL listed to U.S. & Canadian standards

P R O D U C T O R D E R I N G C O D E

E L E C T R I C A L R E C E S S E D F E AT U R E S * Fits within 2'x4' grid for T5, T5HO, and T8

Armstrong by USG

* T8 lamps must be used with optics position option: regressed

compatible

5"

4"

RECESSED T-BAR

S P E C I F I C A T I O N S

FL flush RG regressed (satin/frosted lens only)

S satin lens

F frosted lens

PL semi spec para. louver

SB white louver

A asymmetric reflector

WW wall wash

SW satin wall wash

W C

white custom

optics positionoptics config lamp other

product id length/ft lamp MR16 voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERS rapid start

D dimming

(specify details) TBST Screw Slot T-barT-bar

TG Tegular C custom description if required T5 T5HO T8 (regressed only) 1 one circuit 2 two circuits +E + emergency +M + MR16 B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum

E end mount power feed 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered

7.9

Installation Instructions

3.0

Mounting Options

6.0

Fixture Lengths

i

4.0

Optics

W

FL

5

T5

1

M0

120

E

1

TB

S

B6R recessed

B6R

Asymmetric: See Beam 6 Asymmetric Spec sheet.

* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.

MR16: See Beam 6 MR16 Spec sheet. M# MR16 quantity

*(add 9" per lamp)

Corners: See Beam 6 Corner Spec sheet.

120 UNV 277 347

5.0

Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controls

Sensors are only possible with optics position: (FL) flush

Wall Wash: See Beam 6 Wall Wash Spec sheet.

Staggered not available with 3 lamps.

i

i

i

CONTROLS SENSOR

i

by Armstrong by USG compatible

i

D E TA I L E D I N F O R M AT I O N

(3)

* Staggered not available with lamp config option: (3) three lamps

4.0

Optics

i

i

3.1

Mounting Options

6.0

Fixture Lengths

i

RECESSED DRYWALL

S P E C I F I C A T I O N S

O P T I C S P O S I T I O N Flush (Optics Option: FL)

5"

4"

Regressed (Optics Option: RG) +3/ 4"

5"

4"

satin or frosted acrylic lens (up to 12' lens sections)

drywall ceiling ¼-20 threaded rod (by other) fixture (flanged version) BX cable connector (by other) Flanged (Mounting Option: DF) slip-through bracket (supplied) flange (supplied) Slip-Through Bracket (Mounting Option: DB) Flangeless (Mounting Option: D) Spackle Flange (Mounting Option: DS) drywall finishing plaster drywall edge trim (by other) drywall ¼" threaded rod (by other) finishing spackle drywall spackle flange (supplied) drywall ¼" threaded rod (by other) drywall anchor flange (supplied) drywall ¼" threaded rod (by other)

4

3/4

"

O P T I C S BLANK with MR16

(9'' blank aluminum sections)

* See Beam6 MR16 Spec sheet.

ASYMMETRIC

(asymmetric reflector)

* See Beam6 Asymmetric Spec sheet. SATIN LENS

FROSTED LENS

(acrylic snap-in lens)

satin: 68% transmissive frosted: 85% transmissive M O U N T I N G L A M P C O N F I G U R AT I O N S 1xT5 / T5HO (T5-1) 1xT8 (T8-1)

End to End Lamping

1xT5 / T5HO (T5-1S)

1xT8 (T8-1S)

Staggered Lamping Staggered Lamping

2xT5 / T5HO (T5-2S)

2xT8 (T8-2S)

* See Beam 6 Vertical Recessed Spec sheet. Beam 6 Vertical Recessed

LOUVERS

(semi-spec. parabolic louver/ white louver)

End to End Lamping

2xT5 / T5HO (T5-2)

2xT8 (T8-2)

3xT5 / T5HO (T5-3)

(4)

FL flush

RG regressed (satin/frosted lens only)

S satin lens

F frosted lens

PL semi spec para. louver

SB white louver

A asymmetric reflector

WW wall wash

SW satin wall wash

optics optics position

lamp

config other

product id length/ft lamp MR16 voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERSrapid start

D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C white custom

W

FL

8

T5 1S

M0

120

E

1

S

DF

DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)

DSdrywall spackle flange

B6R recessed

B6R

7.5−7.8

Installation Instructions

3.1

Mounting Options

6.0

Fixture Lengths

4.0

Optics 120 UNV 277 347

5.0

Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controls

Sensors are only possible with optics position: (FL) flush

Asymmetric: See Beam 6 Asymmetric Spec sheet.

Corners: See Beam 6 Corner Spec sheet. Vertical: See Beam 6 Vertical Recessed Spec sheet.

* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.

MR16: See Beam 6 MR16 Spec sheet.

M# MR16 quantity * (add 9" per lamp)

Wall Wash: See Beam 6 Wall Wash Spec sheet.

i

i

i

i

i

B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum

E end mount power feed

Staggered not available with 3 lamps.

CONTROLS SENSOR

P R O D U C T O R D E R I N G C O D E

Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)

Interior Brackets Die Formed Sheet Steel (18 gauge)

Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal) Lenses Extruded Acrylic (0.070'' nominal)

Satin: 68% trans. Frosted: 85% trans. Slip-Through Bracket Die Formed Sheet Steel (18 gauge)

Spackle Flange Die Formed Perforated Sheet Steel (20 gauge) Flange Extruded Aluminum (0.075'' nominal)

visible flange width: 9/

16"

C O N S T RU C T I O N

Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg (4' fixture)

E L E C T R I C A L

Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T5, T5HO, T8

Voltage 120, 277, 347, UNV

Daylight Harvesting / Occupancy Sensors Available Certification UL listed to U.S. & Canadian standards

5"

4"

RECESSED DRYWALL

S P E C I F I C A T I O N S

(5)

Drywall Spackle Flange (Mounting Option: DS) Drywall Flanged (Mounting Option: DF) 5/8" 5/8" 5/8" 5/8" stud drywall mounting bracket (supplied) flange (supplied) 5" 5" 31/ 2" 31/2"

* Beam 6 Vertical Recessed Mount with mounting option: drywall flanged (DF)

mounting bracket (supplied) stud finishing plaster drywall spackle flange (supplied)

VERTICAL WALL RECESSED

S P E C I F I C A T I O N S

T5 - 4' (47

9/16

")

T8 - 4' (49

1/4

")

F R O N T V I E W V E RT I C A L R E C E S S E D M O U N T I N G O P T I O N S

* Beam 6 Vertical Recessed Mounting Options shown with optics position: flush (FL)

NOMINAL 4' FIXTURE LENGTH

(6)

FL flush

RG regressed (satin/frosted lens only)

B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum

E end mount power feed

S satin lens

F frosted lens

PL semi spec para. louver

SB white louver optics optics position lamp config other

product id length/ft lamp MR16 voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERSrapid start

D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C customwhite

W

FL

8

T5 1S

M0

120

E

1

S

DF

DF drywall flanged

DSdrywall spackle flange

B6R recessed +V vertical

B6RV

3.4

Mounting Options

6.0

Fixture Lengths

4.0

Optics 120 UNV 277 347

* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.

MR16: See Beam 6 MR16 Spec sheet. M# MR16 quantity

* (add 9" per lamp)

i

i

i

Staggered not available with 3 lamps.

C O N S T RU C T I O N

Ballast Options Electronic, Dimmable, Emergency Emergency Emergency Battery Pack or Circuit Lamp Options T8, T5, T5HO

Voltage 120, 277, 347, UNV

Certification UL listed to U.S. & Canadian standards E L E C T R I C A L

P R O D U C T O R D E R I N G C O D E

Housing Extruded Aluminum (0.075'' nominal) End Cap Sheet Steel (18 gauge)

Interior Brackets Die Formed Sheet Steel (18 gauge)

Reflectors White Powder Coated Sheet Steel (22 gauge) Louvers Die Formed Semi-Specular Aluminum (22 gauge) White Louvers Die Formed Aluminum Painted White (22 gauge) Blank Extruded Aluminum (0.075'' nominal)

Lenses Extruded Acrylic (0.070'' nominal) Satin: 68% trans. Frosted: 85% trans. Slip-Through Bracket Die Formed Sheet Steel (18 gauge)

Spackle Flange Die Formed Perforated Sheet Steel (20 gauge) Flange Extruded Aluminum (0.075'' nominal)

visible flange width: 9/

16"

Finish Anodized, Powder Coated, Lacquered Weight 12 lbs / 5.5 kg (4' fixture)

VERTICAL WALL RECESSED

S P E C I F I C A T I O N S

5"

4"

(7)

B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum

E end mount power feed

A asymmetric reflector

B6R recessed

optics config lamp other

product id length/ft lamp voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERS rapid start

D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 W white C custom 2 3 4 5 6 8 12 S# system 1 * one lamp

W

B6R

A

4

T5

1

120

E

1

DF

120 UNV 277 347 DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)

DSdrywall spackle flange

TB T-Bar

ST Screw Slot T-Bar

7.5-7.8

Installation Instructions

4.0

Optics

i

i

* Asymmetric is offered for End-to-End 1 T5/T5HO/T8 lamping only.

snap in Asymmetric reflector rests flush with ceiling plane.

4" NOMINAL 4' LENGTH 46 7/16" 41/4" 5" 4" 4" Drywall (Mounting Option: D) T-Bar (Mounting Option: TB) P R O D U C T O R D E R I N G C O D E

Asymmetric Reflector Extruded Aluminum (0.075'' nominal)

C O N S T RU C T I O N

L A M P C O N F I G U R AT I O N

* See Beam 6 Recessed T-Bar or Drywall Spec sheets for further electrical and construction information.

M O U N T I N G O P T I O N S S E C T I O N 1 T5/T5HO/T8 (Code: T5-1, T5HO-1 or T8-1)

ASYMMETRIC RECESSED

S P E C I F I C A T I O N S

5"

4"

(8)

B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum E end mount

power feed

WW wall wash

SW satin wall wash

B6R recessed

optics config lamp other

product id length/ft lamp voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERS rapid start

D dimming (specify details) C custom description if required T5 T5HO T8 1 one circuit 2 two circuits +E + emergency +M + MR16 W white C custom 2 3 4 5 6 8 12 S# system 1 * one lamp

W

B6R

WW

4

T5

1

120

E

1

DF

120 UNV 277 347 DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)

DSdrywall spackle flange

TB T-Bar

ST Screw Slot T-Bar

TG Tegular

i

i

i

3.0

Mounting Options

7.5-7.8

Installation Instructions

4.0

Optics

Corners: See Beam 6 Corner Spec sheet.

* Wall Wash is offered for End-to-End 1 T5/T5HO/T8 lamping only.

4"

NOMINAL 4' LENGTH

46 7/16"

snap in Wall Wash reflector rests flush with ceiling plane.

reflector extends 3/4"

below ceiling plane

41/4" 5" 4" Drywall (Mounting Option: D) T-Bar (Mounting Option: TB) S E C T I O N M O U N T I N G O P T I O N S P R O D U C T O R D E R I N G C O D E L A M P C O N F I G U R AT I O N C O N S T RU C T I O N

Wall Wash Reflector Extruded Aluminum (0.075'' nominal) * See Beam 6 Recessed T-Bar or Drywall Spec sheets

for further electrical and construction information.

1 T5/T5HO/T8

(Code: T5-1, T5HO-1 or T8-1)

5"

4"

WALL WASH RECESSED

S P E C I F I C A T I O N S

(9)

FL flush

RG regressed (satin/frosted lens only)

S satin lens

F frosted lens

PL semi spec para. louver

SB white solid louver

optics optics position

lamp

config other

product id length/ft lamp MR16 voltage ballast

sample or dering options custom mounting finish circuit E electronic

ERS rapid start

D dimming (specify details) C custom description if required T5 T5HO T8 (regressed in T-Bar) 1 one circuit 2 two circuits +E + emergency +M + MR16 2 3 4 5 6 8 12 S# system 0 zero lamps 1 one lamp 2 two lamps 3 three lamps +S staggered W C white custom

W

FL

4

0

M4

120

E

1M

DF

DF drywall flanged D drywall (flangeless) DB slip-through bracket Notify factory for ceilings >3/4" thk.)

DSdrywall spackle flange

TB T-bar

ST Screw Slot T-bar

TG Tegular B6R recessed +V vertical

B6R

7.1−7.10

Installation Instructions

3.0

6.0

Fixture Lengths

4.0

Optics 120 UNV 277 347

5.0

Control Sensors DS daylight sensor OS occ. sensor DOS daylight / occ. sensor controls

Sensors are only possible with optics position: (FL) flush

Corners: See Beam 6 Corner Spec sheet.

* Maximum 4 x MR16 lamps per 4' fixture. Provide a sketch for MR16 locations.

M# MR16 quantity *(add 9" per lamp)

i

i

i

i

i

B# batt. pack (quan./4' sections)

F fuse (one per ballast)

CP chicago plenum

E end mount power feed

Staggered not available with 3 lamps.

9" variable +3/4" 5" 4" 43/ 4" 5" 4" Flush (Optics Option: FL) Regressed (Optics Option: RG) * 6" spacing betweenT-Bars

Blank Extruded Aluminum (0.075'' nominal) MR16 Halogens 2.0'' diameter (35W / 50W)

*MR16 Halogen lamps can be aimed up to 35° from vertical. P R O D U C T O R D E R I N G C O D E O P T I C S P O S I T I O N S M R 1 6 C O N F I G U R AT I O N S C O N S T RU C T I O N Quantity

For every 4' fluorescent lamp section, there may be up to a maximum of 4 x MR16 lamps. Spacing

Each MR16 is placed centered on a blank section 9'' in length. For a series of MR16's within a given section length,

they will be spaced evenly on a longer blank section. * Custom spacing may be available on special request.

Between fluorescent lamps sections Several in a long blank section

MR16

S P E C I F I C A T I O N S

4"

(10)

Pass through wires for a quick connection. 71/ 2" 71/ 2" 107/ 8" 71/ 2" 107/8" 107/ 8" Wall to Ceiling 90 degree corner (Corner Option: WLC) 90 degree Corner (Corner Option: C/LC) 90˚ Corner (Corner Option: C) T Corner (Corner Option: T) X Corner (Corner Option: X) C 90 degree T T junction X X junction LC lit 90 degree WLC wall to ceiling lit 90 degree sample options corner

C

CNR

B6R

product id W white C custom finish

W

The corner modules are an assembly of welded aluminum extrusions. For added rigidity and a secure joining, the assembly uses an internal die

formed sheet steel to align the corners and linear sections of the system. Corner Specification Tip:

* Provide sketches illustrating corner types and locations required. In addition to linear runs, the Beam 6 fixture can be specified

with corners: 90°, T or X sections. * Dimensions below vary for Lit Corners.

B E A M 6 C O R N E R O R D E R I N G C O D E C O R N E R C O N F I G U R AT I O N S

B E A M C O R N E R F E AT U R E S

General Assembly Mitered Aluminum extrusion Side Profile Extruded Aluminum (0.100'' nominal) Blank Cover Extrusion Extruded Aluminum (0.080'' nominal) Interior Brackets Die Formed Sheet Steel (16 gauge) Finish Anodized, Powder Coated, Lacquered Certification UL listed to U.S. & Canadian standards C O N S T RU C T I O N

R E Q U I R E M E N T S Corners are to be ordered in parallel with their corresponding linear sections. Please specify each corner style required with a seperate code (see code below). Mounting points are to be situated on attached linear sections rather than on corners.

All systems requiring corner units must be specified as such at the time of order. Existing linear systems or fixtures cannot have corners added at a later date.

CORNER

S P E C I F I C A T I O N S

5"

4"

References

Related documents

Survivors were asked to rate how their physical, mental, emotional, and relationship health had changed as a result of working with the advocate on a scale of one to five (1: much

However, this figure does not contain the attack potential indicator numbers, it can be concluded, that the message genera- tion phase has a high attack potential, because

Early Morning: Satellite Symposium 2 Morning: Scientific Sessions 4 & 5 Afternoon: Poster Session II3. Special Lecture Late Afternoon:

Means ±SEM (n=8–14) of A, serum glucose concentration, B, insulin concentration, and C, insulin sensitivity measured by the HOMA-IR in fasted control (CTL), hypothalamic obese

Evidence also was found for increased risk of emphysema, but this appeared to be of major concern only with exposures to levels of NO 2 that were much higher than current

Hasil rata-rata analisa kimia terhadap total fenol ikan baung yang di asap dengan menggunakan jenis kayu yang berbeda dapat dilihat pada Tabel 6.

Resource discovery, hence, is especially emphasized when we move toward inter-Clouds approaches or Self Orga- nized Clouds (SOCs). Each single Cloud provider or individual host

For the first research question, the data is obtained through observation during the learning class using the field note as a note during teaching and learning while the data for