Experience
Our Innovation
Rinnai Holdings (Pacific) Pte Ltd
47 Tannery Lane #05-01/02 Elite Industrial Buiding II Singapore 347794 T. +65 6748 9011 F. +65 6745 9240
Helping create a sustainable society as
a comprehensive heat-energy appliance
manufacturer through measures
focusing on the environment, comfort,
and safety and peace of mind.
Bringing more convenience, comfort, and peace of mind to people’s
lifestyles through gas appliances. That is what “interfaces between
heat and lifestyles” is all about. Rinnai has been dedicated to this
concept since its founding in 1920. Our aim is to continue
providing prosperity to everyday lives through the singular energy
source of gas as an industry leader that constantly strives to meet
global needs. Rinnai creates and supplies optimum gas appliances
for today, tomorrow, and the future. In order to help realize a
sustainable society and sustainable planet, Rinnai focuses on the
environment, comfort, and safety and peace of mind in its creation
and supply of optimum heating appliances.
A
b
ou
t
U
s
Rinnai W
ater Heating Sys
te
m
A
d
va
nta
g
e
s
System Advantages
Rinnai Water Heating
Direct fired heat exchanger means instantaneous water heating with unlimited supply of hot water on demand.
This system significantly reduces the load on the structure which will translate to lower cost in reinforcing the concrete and steel structure.
Wall mounted heater help save more space and only require a very small footprint.
The extra room space from the original system can be give up for other services and equipment.
There is huge cut down in electrical power consumption by transferring the heating energy to gas (Clean energy). Lower storage required due to higher efficient
“On Demand” system.
Lesser energy required to maintain the capacity of hot water stored.
Easy modification by adding extra gas heaters if higher capacity is required for future expansion.
Hot water supply is not interrupted by break down of individual heater due to the multiple module installation.
Only quarterly inspection for cleaning of gas heater filters and priming of pump is required. Low maintenance of system helps to cut down labour cost.
Fast and Continuous hot water supply/ Fast recovery rate Structural Loading Space Saving Electrical Saving Smaller Hot Water storage
Flexibility for future expansion
What is a Rinnai Manifold Pack?
A Rinnai Manifold Pack consists No. of. Infinity continuous flow water heaters plumbed together to allow higher flow rates than a single unit can provide.
What are the key features?
• Outlet temperature is preset and remains constant, even when the flow varies
• Peak flow rate cannot be exceeded • No flow = no gas consumption • No wasteful pilot lights
• Usually used for dead leg type installations,
however ringmain pumps can be fitted if required*
*Continuous flow water heaters used on flow and return ringmain systems must have correct pipe and pump selection. For further information, please contact your Rinnai Commercial Representative.
What are some suitable applications?
Applications include (with suggested temperatures):
• Sporting Club Change Rooms - temperature set at 42˚C or 50˚C • Shower Blocks in Caravan Parks - temperature set at 42˚C or 50˚C • Cafés, Restaurants and Pubs - temperatures set at 65˚C
• Hot Water Hoses and Manufacturing Processes - temperature set at 75˚C or 85˚C
What will the SYSTEM offer your application?
Energy savings, as there are no tank heat losses, pilot lights and the system only uses gas when in operation.
Endless hot water for applications where there is a peak demand for only a few hours and then either low or no demand for hours, days or weeks at a time.
M
a
ni
fo
ld
Pa
c
ks
M
a
nif
o
ld
Pa
c
ks
TYPICAL RINNAI MANIFOLD PACK INSTALLATION. Manifold pack drawing
A 375 Manifold Pack MP2 MP3 MP4 MP5 B 750 1125 1500 1875 Dry Weight 60 kg 90 kg 120 kg 150 kg MJ 400 600 800 1000 G H HD Model HD200 e C 245 D 410 E 510 F 610
This is not a formal engineering drawing Insulation not shown on site pipework Ablution areas: temper as required Installation as per local regulations Details subject to change without notice Non return and cold expansion valves are only required on circulating systems Please refer to Rinnai Commercial Representative when designing systems
What is a Rinnai Pool Heating System?
Rinnai Pool Heating system consist of No. of Infinity continuous flow water heaters plumbed together with heat exchanger to heat up the water which contains chlorine or other chemicals.
What are the key features?
• High durability of Infinity continuous water heater itself • High speed recovery
• Space saving
Pr
oject
Po
o
l H
e
a
tin
g
Sy
ste
m
Kitchens in Resort World Sentosa
- Universal Studio Singapore
Bungalow house @ Andrew Road
Supply to 25 Outlets
Rinnai solution TS424E/3PAV etc
Space required 0.2 x 1.6m
Hot water delivery
1st hour & Onward 4,500L/h @ 60deg
Supply to 13 Outlets
Rinnai solution TS224E/1PAV etc
Space required 0.2 x 0.8m
Hot water delivery
1st hour & Onward 2,250L/h @ 60deg
Project Reference
Pool Heating System
for MANIFOLD PACKS
What is A Rinnai Demand Duo SYSTEM?
Rinnai Demand Duo is the combination of between 1 and 6 gas continuous flow water heaters with a storage tank. The storage tank allows a short period of high hot water flow rate, greater than the continuous flow rate of the Infinity water heater(s).
How does IT work?
Demand Duo is a complete packaged storage hot water system made up of one or more Heavy Duty water heaters with a manifold system, primary pump(s), thermostat and a stainless steel storage tank. The thermostat senses the temperature of the water in the tank, and when it drops below the set point, the primary pump is activated. This flow in turn starts the Rinnai continuous flow Infinity water heater which returns heated water to the tank.
What are some suitable applications?
• Hotels & Motels • Apartment Blocks • Student Accommodation • Shower Blocks • Commercial Kitchens • Commercial Laundries
Installations of this type typically have a predictable hot water volume, usually based on number of people living in a particular building either showering, washing or eating, or industrial machines that require regular peaks of water.
Demand Duo are often used on projects on a flow and return system to distribute the water around the building. It should be noted that flow and return systems continually lose heat through the circulation pipework and this adds running costs to the project.
How is the selection made?
Refer to the table for selection examples on pg10.
What are the benefits of rinnai Demand Duo?
Demand Duo storage hot water systems hold 250 to 315 litres of hot water per system. This is available where high peak flow rates for short periods of time are common.
Recovery is matched by selecting the required number of Rinnai Infinity water heaters. The heater(s) can also be mounted many metres (remotely) from the tank.
Note: Extended primary pipe runs must be oversized and/or a primary pump upgrade. Please contact your Rinnai Commercial Representative for further information.
D
e
m
a
nd
D
uo
D
e
m
a
nd
D
uo
A 375 D 715 E 600 PTR INCLUSIONS 1 x HT575 2 x HT575 3 x HT575 + Tee 1 x HT575 & Total System Weight (315 L) 92 115 135 155 175 Mj Rating (HD200’s) 200 400 600 800 1000 Primary Pump UPS20-60B UP25-80B UP25-80B UP25-80B UP25-80B x 2 C 600 1825 2200 2575 2950 B N/A 725 1100 1475 1850 Model DD1 DD2 DD3 DD4 DD5 F 285 G 385 Tank Model 250 Litre 315 Litre H 1475 1855 I 1690 2080 Dry Weight 60 kg 72 kg Wet Weight 310 kg 385 kg M HD Model HD200 e J 410 K 510 L 610This is not a formal engineering drawing Insulation not shown on site pipework Tank control box cover not shown Ablution areas: temper as required Installation as per local regulations Details subject to change without notice
TYPICAL RINNAI DEMAND DUO INSTALLATION.
Demand Duo Selection T
able
Pr
oject
Sentosa Resorts & Spa (Beaufort hotel)
Star Rate 5star
No. of rooms 210
Rinnai solution 5 x TS 224E/1250L & 2 x TS 124E/1250L
Space required 1.5m x 0.8m
Hot water delivery
1st hour 15,250L/h (Total) @ 60C
2nd hour & onward 13,500L/h (Total) @ 60C
NSRCC
Location Changi coast walk
Supply to 59 showersrooms
Rinnai solution TS424I/2250L
Space required 1.6m x 2m
Hot water delivery
1st hour 5,000L/h @ 60C
2nd hour & onward 4,500L/h @ 60C
Wangz Hotel
Location Outram Road
Supply to 41rooms
Rinnai solution TS324I/1250L & TS124I/1250L
Space required 1.6m x 2m
Hot water delivery
1st hour 5,000L/h @ 60C
2nd hour & onward 4,500L/h @ 60C
Indoor System
Retrofitting Project
New Project
Project References For DEMAND DUO
Rinnai Demand Duo
First Hour Delivery: Tank volume + 1,125litres per 1 heater.
Hotel: 3-4 star 35L/min, 5star 45L/min. Allows for showers, meals and laundry.
For further information, please contact your Rinnai Commercial representative.
System Selection Table
The Legend of Fort Canning Park
Supply to 74rooms
Rinnai solution TS 424E/2250E
Space required 2.2m x 1.4m
Hot water delivery@60C
1st hour 5,000L/h @ 60C
2nd hour & onward 4,000L/h @ 60C
Outdoor System
New Project
Hotel Grand Chancellor
Location Belilios Road
Supply to 328rooms
Rinnai solution 2 x TS624E/2315L & 1x TS524E/2315L
Space required 2.4m x 2.0m (Bigger system)
Hot water delivery@60C
1st hour 21,015L/h (Total) @ 60C
2nd hour & onward 19,125L/h (Total) @ 60C
Pr
oject
Pr
oject
New Project
Park Regis Hotel
Location Merchant Road
Supply to 203rooms
Rinnai solution TS 924E/4315L
Space required 3.6m x 2m
Hot water delivery@60C
1st hour 11,385L/h @ 60C
2nd hour & onward 10,125L/h @ 60C
Hotel Miramar
Supply to 200rooms
Rinnai solution TS 224E/1315L
Space required 1.5m x 0.8m
Hot water delivery@60C
1st hour 2,565L/h @ 60C
2nd hour & onward 2,250L/h @ 60C
Outdoor System
New Project
Pr
oject
So
la
r P
re-H
e
a
t S
ys
te
m
Solar Panels Solar Tank Width 1025 600 Height 1937 2080 Depth 80 NA Weight 36 kg 66 kg Concept Drawing Required valves not shown Please contact your Rinnai Commercial Representative for further detailsWhat are rinnai Commercial Solar Pre-Heat systems?
Rinnai Commercial Solar hot water systems provide solar pre-heated water to the Rinnai Commercial gas hot water systems such as the Manifold Pack or Demand Duo system. It can reduce fuel cost at each building and greenhouse gas
emissions.
The system is selected according to the daily hot water demand for the application, the required solar contribution, and what solar zone the system is located in.
HYBRID SYSTEM with EHP
Solar Pre-Heat System
Introduction & Drawing
Project Reference: Resorts World Sentosa
Resorts World Sentosa
Star Rate 5 star
Supply to 6 hotels Crockfords Hotel Festive Hotel
Hard Rock Hotel Singapore Equarius Hotel
Hotel Michael Spa Villas
Rinnai Solution TS2024I
Space required 4m x 0.5m
Hot water delivery
1st hour 22,500L/h @ 60C
Project:
City Gas Senoko Plant
What is Hybrid system of Rinnai Gas system and Electric Heat pump?
Since recovery rate of Electric Heat Pump System is quite slow and require big space, Rinnai Gas system is used to boost EHP(*1) system for faster recovery when demand of hot water is at peak.