• No results found

Water Heaters. Electric Tankless. WHOLE HOME Hot Water on Demand. Single & Multipoint Hot Water on Demand. Advanced Heating & Hot Water Systems

N/A
N/A
Protected

Academic year: 2021

Share "Water Heaters. Electric Tankless. WHOLE HOME Hot Water on Demand. Single & Multipoint Hot Water on Demand. Advanced Heating & Hot Water Systems"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

Electric Tankless Water Heaters

Advanced Heating

& Hot Water Systems

Whole Home Units

Powerful enough to supply endless, hot water for your entire home, all in a highly efficient compact unit.

Intelligent Modulating Power Control

The smart control logic allows setting the desired temperature on the user-friendly digital display. The unit will ensure steady output temperature by automatically adjusting the power as flow varies

Long Lasting

The selection of materials is the secret behind the durability of these water heaters. The heating elements are made of dependable TITANIUM (Whole Home) and COPPER (Single &

Multipoint) which are great for resisting corrosion.

SAVE ENERGY

& SPACE Highly Efficient - Save Both Energy & Money - Energy is Not Wasted Keeping Stored Water Hot - Saves Space

EASY

INSTALLATION Quick & Simple Installation You Will Love How Easy It Is, Saves You Time

6 YEAR WARRANTY Durable Heater With A Strong Limited 6 Year Warranty

Single & Multipoint

Hot Water on Demand WHOLE HOME Hot Water on Demand

MULTIPOINT Single Point of Use or Multipoint Use - No Recirculation Line Needed with Endless Hot Water Near the Tap

Water Savings

Instant hot water upon demand! No water is wasted while one is waiting for hot water to arrive from the tank.

Installation is a Breeze

All that is required is a cold water line and an electrical connection to install this water heater at the sink.

Point of Use Units

Space saving compact design. Eliminates the need for a recirculation line. Great for remote locations.

Up to 50% Energy Saving

Energy is activated only when hot water is used. Unlimited hot water supply - No energy is wasted keeping stored water hot.

Compact Size, High Performance

Endless hot water wherever you need it.

®

A BRAND OF

www.htproducts.com

(2)

Single & Multipoint

Model EVISP 3-110 CP EVISP 6.5-240 EVISP 10.5-240 EVISP 13-240

KW 3.1-3.5 KW 6.5 KW 10.5 KW 13 KW

Volts

*

110 -120 240 240 240

AMPS 28-29 27 44 54

Dimensions 7.3” H x 1 1.8” W x 3.5” D

6 YEAR WARRANTY 2 YEAR PARTS

Durable Electric Tankless with a Strong Limited 6 Year Warranty Against Leaks

MONEY

TIME

WATER

ENERGY

Benefits of Electric Tankless

Water Heaters

SAVE

Eco-Friendly Endless Hot Water No Stored Hot Water,

Saving You Money Easy Maintenance

Hot Water On Demand

*6.5-13KW models can be run at 208V with a reduction in KW. See installation manual for further details.

(3)

Whole Home

Model EVIWH 18-240 EVIWH 24-240 EVIWH 27-240 EVIWH 36-240

KW 18 KW 24 KW 27 KW 36 KW

Volts

*

240 240 240 240

AMPS 75 100 112.5 150

Dimensions 13.4” H x 1 8.9” W x 4.5” D 13.4” H x 23.2” W x 4.5” D (36 KW)

TITANIUM ELEMENT Long Lasting Titanium Element Installed

DIGITAL DISPLAY A Simple Quality Digital Display

That is Easy to Use 6 YEAR WARRANTY - 2 YEAR PARTS

3 YEAR TITANIUM ELEMENT Durable Electric Tankless with a Strong Limited 6 Year

Warranty Against Leaks (18, 27 & 36kW Units)

CONSTANT TEMPERATURE Ensures Comfort Delivering a Constant Temperature

Water Flow Whenever and Wherever You Want

SAVE - Money, Water, Time, Space & Energy

RESIDENTIAL COMMERCIAL

*Units can be run at 208V with a reduction in KW. See installation manual for further details.

(4)

3 Simple Steps to Finding Your TrueFit - HTP Everlast Electric Water Heater

Inlet Temp.

Single & Multipoint Whole Home

110-120V 3.1-3.5 KW

6.5 KW 240V 10.5 KW 240V 13 KW 240V 18KW 240V 24KW 240V 27 KW 240V 36 KW 240V

40 º F

Max Flow Rate .7 GPM 1.1 GPM 1.4 GPM 1.9 GPM 2.5 GPM 2.8 GPM 3.8 GPM

50 º F

Max Flow Rate .5 GPM .8 GPM 1.3 GPM 1.6 GPM 2.2 GPM 2.9 GPM 3.4 GPM 4.5 GPM

60 º F

Max Flow Rate .5 GPM 1 GPM 1.6 GPM 2 GPM 2.7 GPM 3.6 GPM 4 GPM 5.5 GPM

70 º F

Max Flow Rate .6 GPM 1.3 GPM 2 GPM 2.5 GPM 3.5 GPM 4.6 GPM 5.3 GPM 7 GPM

Inlet Water 70 º F Inlet Water 60 º F

Inlet Water 50 º F Inlet Water 40 º F

STEP 1:

Use the map to the right to locate your correct region to determine approximate ground water temperature.

STEP 2:

Find your water tempera- ture on the chart below to determine the capacity of fixtures the hot water can be supplied to at one time.

STEP 3:

Reference the chart below to determine which model best suits your needs.

Fixture Flow Rates

Shower 1.5 GPM

(Range 1.5 -2.5)

Sink .5 GPM

(Range.5-1.5)

- Max Flow Rate Calculated for 105ºF Outlet Water Temperature - Standard Install is 240V, if 208V is used Increase One Model Size from the Chart Below

(5)

Inlet Water 70 º F Inlet Water 60 º F

Inlet Water 50 º F Inlet Water 40 º F

Compact Design Allows for Installation

Flexibility Under Sinks,

in Closets, Kitchenette,

Basement, Garage, Utility Room

and More Hot Water Where

You Need it!

MULTIPOINT SINGLE POINT

SAVE up to

50 %

on Water

Heating Costs

(6)

Specifications

Whole Home Single Multipoint

In accordance with our company policy of ongoing product improvement, HTP reserves the right to make changes without prior notice. All weights & dimensions in this catalog are approximate.

www.htproducts.com • 272 Duchaine Blvd, New Bedford, MA • © Ariston Thermo USA LLC. 11/4/2020 • MKTLIT-124 Model

*

Wattage (kW) Max Amperage Required Breaker(s) Required Wire Size

18 75 3 x 30A Double Pole 3 x 10 AWG w/ Ground

3 x 40A Double Pole 3 x 8 AWG w/ Ground

27 112.5

36 150 4 x 40A Double Pole 4 x 8 AWG w/ Ground

Technical Data All Models

Minimum Water Flow to Activate Unit

0.5 gpm

Working Pressure 7 - 150 psi (0.5 - 10 bar)

Tested Pressure 290 psi (20 bar)

Water Connections 3/4” NPT

Elements 18 - 27kW 2

36kW 3

Dimensions 18 - 27kW 20.7” (526 mm) Width x 13.3” (339 mm) Height x 4.5” (114 mm) Depth 36kW 25” (636 mm) Width x 13.3” (339 mm) Height x 4.5” (114 mm) Depth

Weight (Empty) 18 - 27kW 12.17 lb (5.52 kg)

36kW 16.23 lb (7.36 kg)

Temperature Range 86 - 122

o

F (30 - 50

o

C)

Temperature Rise Δt (

o

F) Flow Rate (GPM)

18kW 24kW 27kW 36kW

35 3.51 4.68 5.26 7.02

45 2.73 3.64 4.09 5.46

77 1.59 2.12 2.39 3.19

EVIWH 18-240

EVIWH 27-240

3 x 40A Double Pole 3 x 8 AWG w/ Ground

24 100

EVIWH 24-240

EVIWH 36-240

*Wattage based on max voltage

*Wattage based on max voltage

s l e d o M l l A a

t a D l a c i n h c e T

Minimum Water Flow to Activate Unit 0.55 gpm

Working Pressure 7 - 115 psi (0.5 - 8 bar)

Tested Pressure 230 psi (16 bar)

Water Connections 1/2” NPT

Elements 1

Dimensions 12” (304 mm) Width x 7” (178 mm) Height x 3.85” (98 mm) Depth

Weight (Empty) 3.4 lb (1.54 kg)

Temperature Range 90 - 131

o

F (30 - 55

o

C)

Voltage Amperage Phase Circuit Breaker Size Required Wire Size 110/120 28/29

1

1 x 30

10 AWG 240

0 3 x 1 7

2

6 AWG 0

5 x 1 4

4

G W A 4 0

6 x 1 4

5

*Wattage

(kW) 110V 120V 208V 240V

3 3.1kW 3.5kW - -

6.5

- -

4.9kW 6.5kW W k 5 . 8 W k 4 . 6 5

. 8

10.5 7.9kW 10.5kW

W k 0 . 3 1 W k 8 . 9 3

1

Temperature Rise Δt (

o

F)

Flow Rate (GPM)

3kW 6.5kW 8.5kW 10.5kW 13kW

35 0.59 1.26 1.65 2.04 2.53

45 0.45 0.98 1.28 1.59 1.97

77 0.26 0.57 0.75 0.93 1.15

EVISP 3-110 CP 3.1-3.5 6.5 10.5

13 EVISP 6.5-240 EVISP 10.5-240

EVISP 13-240 Model

Watts(kW)

Technical Specifications - *Wattage based on maximum voltage.

NOTE: On 3kW models, a 0.5 GPM flow restrictor is recommended for optimal operation.

NOTE: On 6.5, 8.5, 10.5, and 13kW models, no wires are included for external wiring. All external wiring is to be field supplied.

References

Related documents

Table 1 – Quality Improvement and Depression 1,5,6 Quality Measure Quality Indicator #4 Quality Indicator #5 RAP Problem Area: Mood State Proposed measure of treatment

District energy systems produce steam, hot water or chilled water at a central plant that is then piped underground to individual buildings for space heating, domestic hot

In the postcolonial intensification of “kastomization” in national politics in Vanuatu (Lindstrom 1997)—that is, of making the state “kastom friendly” and vice

“Serendipity” being left by its owner in the Bahamas without a full time licensed Captain, placed the vessel in a position where there was no dedicated vessel Captain to monitor

We characterized seasonal variations in microclimate and CLR incidence across di ff erent altitudes and shading systems, and integrated e ff ects between the environment, shading

Whereas in Part I, out-of-core, LOD-based parallel point and terrain rendering contributions are discussed, Part II draws details on LOD and parallel solutions in context of

Figure 1 shows the distribution of 65 content and structure characteristics in 100 suicide notes on the two-dimensional SSA. The coefficient of alienation only being .15 suggests a

Please notice that only European Community’s legislation published in the paper editions of the Official Journal of the European Communities is deemed authentic.. This text