General

CONDOR is a supply air ceiling system with adjustable discs. The spread pattern is infinitely flexible and can be adjusted as required without affecting the airflow, pres- sure drop or sound level. The supply air can be at over- or under-temperature. CONDOR is particularly suitable for applications where large supply airflows are required without high air velocities in the occupied zone, for example in laboratories, clean rooms, hospitals, catering kitchens and schools. The discs in the fi gure are arranged in a special pattern.

Quick facts

100% flexible spread pattern s

High induction rate s

Can be cleaned s

Diffuser modules 595 x 595 mm s

Available in alternative colours s

VariZon

s ®air distribution system

Included in MagiCAD and CadVent databases s

Quick guide

A I R F L O W - S O U N D L E V E L

CONDOR l/s

Size 30 dB(A)

1200- 600 - 250 140

1800 - 600 - 315 200

2400 - 600 - 315 245

3000 - 600 - 400 x 250 310

1200 - 1200 - 315 260

1800 - 1200 - 600 x 200 360

2400 - 1200 - 600 x 300 490

3000 - 1200 - 800 x 250 570

(2)

Technical description

Design

The supply air ceiling consists of a number of diffuser modules, equipped with discs, which are installed in a common backing box. The air diffuser modules are also equipped with the VariZon air distribution system to dis- tribute air uniformly.

Materials and surface treatment

The supply air ceiling is manufactured in galvanised sheet steel. The discs are made of ABS plastic and the VariZon® air distribution plates are made of polypropylene. The entire unit is painted with our pure white standard paint, RAL 9010. The unit is also available in other standard colours: Dusty grey 7037, white aluminium RAL 9006, jet black RAL 9005, grey aluminium RAL 9007 and signal white RAL 9003 (NCS 0500).

Special version

In addition to the standard sizes, this unit can be supplied in special dimensions and with different numbers of discs, etc. CONDOR is also available in galvanized finish. Please contact your nearest sales office for information.

Accessories

CRM. Commissioning damper with measuring unit.

Planning

The unit can be installed freely suspended or integrated in a suspended ceiling.

The recommended maximum under-temperature is 5°C.

The recommended minimum installation height above the floor is 2.7 m.

Installation

The backing box has a number of M8 pop nuts on top and a number of attachment eyes along the sides for sus- pended installation. The backing box can also be bolted directly to the building structure from inside the box. The diffuser panels are inserted into the backing box at an angle, with the VariZon®distribution plates facing the airflow, then laid on the grid. See Figure 1.

Commissioning

(3)

Sizing

The sound level dB(A) applies to rooms of 10 m

s 2

equivalent sound absorption area.

The recommended maximum under-temperature with s

a standard discs installation is 5°C.

To calculate the width of the airstream, air velocities in s

the occupied zone or sound levels in rooms with other dimensions, contact the nearest sales office for infor- mation.

Sound data - CONDOR - Supply air

Sound power level Lw(dB) (10 m2Sabine) Table KOK

CONDOR Mid-frequency (octave band) Hz Size 63 125 250 500 1000 2000 4000 8000

1200-600-250 5 9 7 3 -4 -16 -19 -13

1800-600-315 6 10 7 4 -5 -17 -18 -13 2400-600-315 5 11 8 2 -5 -16 -17 -12 300-600 -

400 x 250

2 12 7 3 -6 -17 -20 -15

1200-1200-315 6 9 8 3 -4 -15 -16 -11 1800-1200-

600 x 200

5 11 8 3 -6 -15 -16 -10

2400-1200- 600x300

6 9 8 3 -6 -17 -14 -9

3000-1200- 800 x 250

4 12 9 2 -7 -20 -13 -7

Tol. ± 2 2 2 2 2 2 2 2

Sound attenuation 'L (dB) (10 m2Sabine) Table 'L

CONDOR Mid-frequency (octave band) Hz Size 63 125 250 500 1000 2000 4000 8000

1200-600-250 15 10 5 2 2 3 4 5

1800-600-315 14 9 4 1 0 1 2 2

2400-600-315 14 9 4 1 0 1 2 2

3000-600- 400 x 250

10 6 4 1 1 1 1 1

1200-1200-315 14 9 4 1 0 1 2 2

1800-1200- 600 x 200

10 6 4 1 1 1 1 1

2400-1200- 600 x 300

8 4 3 1 1 1 1 1

3000-1200- 800 x 250

6 3 1 0 0 0 0 0

Tol. ± 2 2 2 2 2 2 2 2

(4)

Engineering graphs – CONDOR – Supply air Airflow – Pressure drop – Sound level – Affected area

The graphs must not be used for commissioning.

s

The dB(A) values are for rooms with normal acoustic s

absorption of 4 dB.

The dB(C) value is normally 6-9 dB’s higher than the s

dB(A) value. For more accurate calculations, see the calculation template in the chapter on Acoustics in the Technical Information section of this catalogue.

CONDOR - Single

ptPa ptPa

300 400 500 1000 2000 m3/h

ptPa ptPa

100 200 300 400 500 l/s

2 3 45 10 20 30 4050 100

20 25

30 35 40 dB(A)

1 2 3

4

4 3 2

1 2 3 4 5

1

0,2m l

Size designation:

1. 1200-600-250 2. 1800-600-315 3. 2400-650-315 4. 3000-600-400 x 250

CONDOR - Double

Size designation:

1. 1200 x 1200-350 2. 1800 x 1200-600x200 3. 2400 x 1200-600x300 4. 3000 x 1200-800x250

ptPa ptPa

400 500 1000 2000 m3/h

ptPa ptPa

100 200 300 400 500 l/s 1000

1 2 3 45 10 20 30 4050

20 25

30 35 40 dB(A)

1 2 3

4

4 3 2

1 2 3 4 5

1

0,2m l

(5)

Dimensions and weights

Size Weight, kg

1200-600-250 27,0

1800-600-315 41,0

2400-600-315 54,0

3000-600-400 x 250 68,0

1200-1200-315 46,0

1800-1200-600 x 200 69,0

2400-1200-600 x 300 92,0

3000-1200-800 x 250 115,0

Figure 2. CONDOR, dimensions.

(6)

Order key

Product

Supply air ceiling system CONDOR -a -aaaa -bbb -ccc Version:

Nom. length, mm:

1200, 1800, 2400, 3000 Nom. width, mm:

600, 1200

Nom. connection diam., mm:

Ø: 250, 315

Rectangular dimensions:

400 x 250, 600 x 200, 600 x 300, 800 x 250

Standard range: 1200-600-250 1800-600-315 2400-600-315 3000-600-400 x 250 1200-1200-315 1800-1200-600 x 200 2400-1200-600 x 300 3000-1200-800 x 250

Specification example

SD XX

Swegon’s supply air ceiling system, type CONDOR, with the following functions:

Diffuser modules 595 x 595, equipped with nozzles s

100% flexible spread pattern s

Individually adjustable nozzles (55 mm) made from s

recyclable ABS plastic VariZon

s ®air distribution system Can be cleaned

s

Powder coated in white s

Backing box that can be cleaned s

Size: CONDOR a - aaaa - bbb - ccc xx items

References

Related documents

Ventilation unit for ceiling installation TROX SCHOOLAIR-V-HV with supply and extract air function, rotary heat recovery unit and switchover option to secondary air operation

Male Swiss mice weighing 25-35 g, maintained under standard environmental conditions, were used distributed in groups of ten (writhing, formalin, hot-plate and rota-rod

The measurement tapping for supply air is located in the duct connection of the air diffuser whereas the measure- ment tapping for extract air is located inside the commis-

2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance (duct resistance, diffuser, etc.) Then

However, according to Modigliani and Miller Theory, capital structure does not affect the value of the firm which means value of the levered firm is same as

DL micro exchange rate models abstract from the market as a whole and focus instead on price setting and risk management by individual currency market par- ticipants, or dealers..

BIOREACTER BIOREACTER.. Fermenter desi*n.

2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance (duct resistance, diffuser, etc.) Then