DESAIN KEKUATAN KOLOM SQ & RE
SISTEM RANGKA PEMIKUL MOMEN KHUSUS (SRPMK)
A. GENERAL INFORMATION
Project : OTHER Engineer : Puji Kurniawan,ST
kolom : K 40/80 Units : Metric
Code : SNI 2847-2013 / ACI 318-14
MATERIAL PROPERTIES
Concrete
Mutu beton kolom, K- 350 fc'k = 29.1 MPa
Modulus elastisitas kolom beton, Ec.k = 25332.1 MPa
Mutu beton balok, K- 350 fc'b = 29.1 MPa
Modulus elastisitas balok beton, Ec.b = 25332.1 MPa
Regangan maksimum, ec = 0.003 MPa
Steel
Mutu baja tulangan pokok kolom, fy = 400 MPa
Mutu baja tulangan sengkang kolom, fys = 400 MPa
Mutu baja tulangan pokok balok, fy = 400 MPa
Mutu baja tulangan sengkang balok, fys = 400 MPa
Mutu baja tulangan pelat lantai, fysb = 240 MPa
Regangan maksimum, es = 0.002 MPa
SECTION PROPERTIES "TINJAUAN SEARAH SUMBU X"
Panjang searah sumbu x, x-axis = b = 400 mm
Diameter tulangan sengkang, Ds = 13 mm
Tulangan kolom,
22
D
22
Gross section area, A = 320000 mm2
Momen inersia, Iy = 1/12 * b3 * h = mm4
Radius giration, ry = Iy / A = 115.5 mm
X0 = 0 mm
SECTION PROPERTIES "TINJAUAN SEARAH SUMBU Y"
Panjang searah sumbu y, y-axis = h = 800 mm
Selimut beton, sb = 40 mm
Luas tulangan total, As = 8362.9 mm2
Gross section area, A = 320000 mm2
Momen inersia, Ix = 1/12 * b * h 3 = mm4 Radius giration, rx = Ix / A = 230.9 mm Y0 = 0 mm 4266666667 17066666667
B. KLASIFIKASI PORTAL
Q = ( Pu * Do / Vus * ℓu ) < 0,05
Portal Tidak Bergoyang Q = ( Pu * Do / Vus * ℓu ) > 0,05
Portal Bergoyangℓ
u = Tinggi KolomPu = Beban vertikal terfaktor total (Comb : 1,2 DL + 0,5 LL)
Do = Defleksi lateral relatif orde pertama antara tepi atas dan bawah tingkat tersebut Vus = Gaya geser tingkat horisontal pada tingkat yang dievaluasi
2.1 KLASIFIKASI PORTAL ARAH "X"
Tinggi Efektif kolom,
ℓ
u.x= L - h
b=
3400.0 mmBeban vertikal terfaktor total (Comb : 1,2 DL + 0,5 LL)
P
u=
39859.3 kN Defleksi lateral relatif orde pertama antara tepi atas dan bawah tingkat tersebutD
0.x=
5.8 mm Gaya geser tingkat horisontal pada tingkat yang dievaluasiV
us.x=
7350.7 kNQ.
x= (
P
u*
D
o/ V
us* ℓ
u.x) < 0,05 =
0.009 mmNon-Sway Frame
2.2 KLASIFIKASI PORTAL ARAH "Y"
Tinggi Efektif kolom,
ℓ
u.y= L - h
b=
3400.0 mmBeban vertikal terfaktor total (Comb : 1,2 DL + 0,5 LL)
P
u=
39859.3 kN Defleksi lateral relatif orde pertama antara tepi atas dan bawah tingkat tersebutD
0.x=
7.23 mm Gaya geser tingkat horisontal pada tingkat yang dievaluasiV
us.x=
7570.2 kNQ.
x= (
P
u*
D
o/ V
us* ℓ
u.y) < 0,05 =
0.011 mmNon-Sway Frame
C. PEMBEBANAN
Parameter percepatan spektra desain, periode pendek
S
DS=
0.55 SecFaktor kuat lebih sistem
W
0=
2.5Faktor Redudansi
r
=
1.3Apakah menggunakan paktor kuat lebih..??
=
No3.1 BEBAN TIDAK TERFAKTOR (SERVICE LOAD)
No. Load Case Pux Puy Mx.Top Mx.Bot My.Top My.Bot Sustained
(kN) (kN) (kNm) (kNm) (kNm) (kNm) Load
3.1.1 Kombinasi Beban Tinjauan Arah X
No Dead Live Roof Live Wind Sesmic Axial load My.Top My.Bot EQ / RSP (kN) (kNm) (kNm) 1 1.4 0.00 0.0 0.0 0.0 1684.2 -34.3 29.5 2 1.2 1.60 0.5 2088.4 -22.1 18.5 3 1.2 0.50 1.6 1645.1 -27.1 23.2 4 1.2 1.6 0.5 1443.6 -29.4 25.3 5 1.2 1.6 -0.5 1443.6 -29.4 25.3 6 1.2 0.50 0.5 1.0 1645.1 -27.1 23.2 7 1.2 0.50 0.5 -1.0 1645.1 -27.1 23.2 8 1.2 0.50 1.0 1645.1 -27.1 23.2 9 1.2 0.50 -1.0 1645.1 -27.1 23.2 10 0.9 0.50 1.0 1284.2 -19.8 16.8 11 0.9 0.50 -1.0 1284.2 -19.8 16.8 12 1.311 1.00 1.3 1984.6 -198.0 174.3 13 1.311 1.00 -1.3 1974.7 143.0 -127.6 14 0.789 1.3 954.6 -189.9 167.6 15 0.789 -1.3 944.7 151.2 -134.3 16 1.311 1.00 1.3 1967.4 228.1 250.1 17 1.311 1.00 -1.3 1992.0 -283.1 -203.4 18 0.789 1.3 937.3 236.3 243.4 19 0.789 -1.3 961.9 -275.0 -210.1
3.1.2 Kombinasi beban Tinjauan Arah Y
No Dead Live Roof Live Wind Sesmic Axial load Mx.Top Mx.Bot EQ / RSP (kN) (kNm) (kNm) 1 1.4 0.00 0.0 0.0 0.0 1684.2 -386.1 171.7 2 1.2 1.60 0.5 2088.4 -347.8 164.6 3 1.2 0.50 1.6 1645.1 -336.2 152.6 4 1.2 1.6 0.5 1443.6 -330.9 147.2 5 1.2 1.6 -0.5 1443.6 -330.9 147.2 6 1.2 0.50 0.5 1.0 1645.1 -336.2 152.6 7 1.2 0.50 0.5 -1.0 1645.1 -336.2 152.6 8 1.2 0.50 1.0 1645.1 -336.2 152.6 9 1.2 0.50 -1.0 1645.1 -336.2 152.6 10 0.9 0.50 1.0 1284.2 -253.5 115.8 11 0.9 0.50 -1.0 1284.2 -253.5 115.8
12 1.311 1.00 1.3 2002.6 -455.7 241.7 13 1.311 1.00 -1.3 1956.8 -288.3 101.6 14 0.789 1.3 972.5 -301.4 166.9 15 0.789 -1.3 926.7 -134.0 26.8 16 1.311 1.00 1.3 1940.5 -230.1 290.0 17 1.311 1.00 -1.3 2018.8 -513.8 53.3 18 0.789 1.3 910.5 -75.9 215.2 19 0.789 -1.3 988.8 -359.5 -21.6
3.2 REKAP KOMBINASI BEBAN (LOAD COMBINATION)
Rekap Beban Desain
Load Axial load Mx.Top Mx.Bot My.Top My.Bot
Combination (kN) (kNm) (kNm) (kNm) (kNm) U1 1,4DL 1684.2 -386.1 171.7 -34.3 29.5 U2 1,2DL + 1,6LL + 0,5RL 2088.4 -347.8 164.6 -22.1 18.5 U3 1,2DL + 0,5LL + 1,6RL 1645.1 -336.2 152.6 -27.1 23.2 U4 1,2DL + 1,6RL + 0,5 W 1443.6 -330.9 147.2 -29.4 25.3 U5 1,2DL + 1,6RL + -0,5 W 1443.6 -330.9 147.2 -29.4 25.3 U6 1,2DL + 0,5LL + 0,5RL + 1W 1645.1 -336.2 152.6 -27.1 23.2 U7 1,2DL + 0,5LL + 0,5RL + -1W 1645.1 -336.2 152.6 -27.1 23.2 U8 1,2DL + 0,5LL + 1W 1645.1 -336.2 152.6 -27.1 23.2 U9 1,2DL + 0,5LL + -1W 1645.1 -336.2 152.6 -27.1 23.2 U10 0,9DL + 0,5LL + 1W 1284.2 -253.5 115.8 -19.8 16.8 U11 0,9DL + 0,5LL + -1W 1284.2 -253.5 115.8 -19.8 16.8 U12 1,2DL + 0,2 Sds + 0,5LL + 1rEQ 1984.6 -455.7 241.7 -198.0 174.3 U13 1,2DL + 0,2 Sds + 0,5LL + -1rEQ 1974.7 -288.3 101.6 143.0 -127.6 U14 0,9DL - 0,2 Sds + 1rEQ 954.6 -301.4 166.9 -189.9 167.6 U15 0,9DL - 0,2 Sds + -1rEQ 944.7 -134.0 26.8 151.2 -134.3 U16 1,2DL + 0,2 Sds + 0,5LL + 1rRsp 1967.4 -230.1 290.0 228.1 250.1 U17 1,2DL + 0,2 Sds + 0,5LL + -1rRsp 1992.0 -513.8 53.3 -283.1 -203.4 U18 0,9DL - 0,2 Sds + 1rRsp 937.3 -75.9 215.2 236.3 243.4 U19 0,9DL - 0,2 Sds + -1rRsp 961.9 -359.5 -21.6 -275.0 -210.1 Envelove Max 2088.4 -75.9 290.0 236.3 250.1 Envelove Min 937.3 -513.8 -21.6 -283.1 -210.1
D. TINJAUAN SEARAH SUMBU X (Momen Y : M
uy= M
3)
1. FAKTOR PANJANG TEKUK KOLOM
Searah.sb. X :300 300
500
L
b.L=
6 500L
b.R=
6ℓ
u.x=
3.5b = X.axis = 400.0 Above Column h = Y.axis = 500.0 300 300 500
L
b.L=
6 500L
b.R=
6ℓ
u.x=
3.4 b = X.axis = 400.0 Design h = Y.axis = 800.0 300 300 500L
b.L=
6 500L
b.R=
6ℓ
u.x=
2.5b = X.axis = 400.0 Below Column h = Y.axis = 800.0 250 250 400
L
b.L=
6 400L
b.R=
6 + 0,00 hc bc x y Pu Muy Muy kolom DesainAbove Left Above Right
Vu Vu Pu Lu hb hpl bc Lb
Momen inersia Kolom,
I
y= 1/12 * b
3* h
Modulus elastisitas beton
E
c= 4700 *
f
c'
Kekakuan lentur efektif kolom,EI = E
c* 0,7 * I
ySlenderness
Sway Criteria : Non-Sway Frame
Mutu beton kolom, 2
f
c' =
29.1 MPakolom Axis Height Width 'b' Depth 'h' Iy Ec EIk EIk / ℓu
(m) (mm) (mm) (mm4) MPa MPa
Design X 3.40 400 800 4.3.E+09 3.E+04 8.E+13 2.2E+10
Above X 3.50 400 500 2.7.E+09 3.E+04 5.E+13 1.4E+10
Below X 2.50 400 800 4.3.E+09 3.E+04 8.E+13 3.0E+10
Mutu beton balok,
f
c' =
29.1 MPaX-Beams Length Width Depth I Ec EIb.x EIb.x / L
Location (m) (mm) (mm) (mm4
) MPa MPa
Above Left 6.00 300 500 3.1.E+09 3.E+04 3.E+13 4.6E+09
Above Right 6.00 300 500 3.1.E+09 3.E+04 3.E+13 4.6E+09
Below Left 6.00 300 500 3.1.E+09 3.E+04 3.E+13 4.6E+09
Below Right 6.00 300 500 3.1.E+09 3.E+04 3.E+13 4.6E+09
Effective Length Factors: Opsional K = 0.00
Axis Y(top) Y(bot) k(Nonsway) k(Sway) ℓu.x (mm) k ℓu / ry
2. KLASIFIKASI KOLOM & PEMBESARAN MOMEN
2.1 Menentukan Kolom Panjang Atau Pendek
Lebar kolom,
b =
400.0 mmtinggi kolom,
h =
800.0 mmTinggi efektif kolom,
ℓ
u.x=
3400.0 mmInersia penampang kolom,
I
y= 1/12 * b
3
* h =
4.27.E+09 mm4Luas tampang kolom,
A
g= b * h =
320000 mm2Jari-jari inersia penampang kolom,
r
y=
[ I
y/ A
g] =
115.5 mmFaktor panjang tekuk,
K
x=
0.926Angka kelangsingan,
K * ℓ
u.x/ r
y=
27.27Momen ultimate terkecil kolom,
M
1=
203.40 kNmMomen ultimate terbesar kolom,
M
2=
283.15 kNmM
1/ M
2=
0.72 Single Curvatur Syarat batas kelangsingan,Kℓ
u/ r < 34 - 12 * ( M
1/ M
2) < 40 =
25.38Kolom Panjang Perlu Pembesaran Momen
2.2 Pembesaran Momen
Pengaruh buckling diperhitungkan dengan cara Perbesaran Momen pada kolom sbb.
Gaya aksial ultimit kolom,
P
u=
1991.96 kNBeban mati ultimit pada kolom :
P
u_DL= 1,2 DL =
1443.60 kN Beban hidup ultimit pada kolom :P
u_LL= 1 LL =
403.00 kN Nilai perbandingan beban mati ultimit terhadap beban tetap ultimit :Mutu beton kolom,
f
c' =
29.1 MPaMutu beton kolom,
E
c= 4700 *
f
c' =
25332.1 MPaβ
d= DL / (DL + LL) =
0.782Kekakuan lentur kolom,
EI = 0.4 * E
c* I
y/ (1 + β
d) =
24264.43 kNm 2Beban aksial kritis,
P
c=
p
2
* EI / ( K * ℓ
u.x)
2=
24122 kNWith Transversal load
C
m= 0,6 + 0,4 * ( M
1/ M
2) atau 1 =
1.00 Faktor perbesaran momen,d
s= C
m/ [ 1 - P
u/ (0.75 * P
c) ] =
1.12Momen ultimate minimum,
M
2,Min= P
u* ( 15,24 + 0,03 * b ) =
54.26 kNm Momen ultimate,M
uy= Max(M
2; M
2min) =
318.18 kNm3. REKAP GAYA AXIAL & MOMEN ULTIMATE
Load Pu Muy Muy Mny Comb (kNm) (kNm) (kNm) (kNm) U1 1684 56.9 318.2 675 U2 2088 56.9 698 U3 1645 56.9 675 U4 1444 56.9 655 U5 1444 56.9 655 U6 1645 56.9 670 U7 1645 56.9 671 U8 1645 56.9 671 U9 1645 56.9 671 U10 1284 56.9 642 U11 1284 56.9 642 U12 1985 198.0 694 U13 1975 143.0 694 U14 955 189.9 608 U15 945 151.2 600 U16 1967 250.1 694 U17 1992 283.1 691 U18 937 243.4 614 U19 962 275.0 614 Envelove Max 2088.4 283.1 698.0 Envelove Min 937.3 56.9 600.04. DESAIN KOLOM SRPMK
4.1. Persyaratan Dimensi Kolom
Lebar penampang kolom,
b =
400.00 mmTinggi penampang kolom,
h =
800.00 mmGaya aksial ultimit kolom terkecil,
P
u.Min=
937.34 kNLuas tampang kolom,
A
g= b * h =
320000.00 mm2
Kuat tekan beton,
f
c' =
29.05 MPa- Gaya Akxial terfaktor maksimum yang bekerja pada kolom harus menenuhi Ag * fc' /10
A
g* f
c' /10 =
929.60 kNAMAN.!
Penampang kolom terkecil tidak kurang dari 300 mm
b =
400.00 mm AMAN.!Rasio dimensi penampang tidak kurang dari 0,4
b / h =
0.50 AMAN.! Rasio tulangan kolom 1% < r < 6%r
= ( A
s/ b * h ) * 100 =
2.61AMAN.! Cek pengaruh efek beban gempa ortogonal,
P
umax.Qe=
9.45 kNf
P
n.max= 0,8 *
f
* [ 0,85 * f
c' * (A
g- A
st) + f
y* A
st] =
5740.94 kNP
umax.Qe <20 %
f
P
n.max Abaikan.!4.2. Persyaratan "Strong kolom Weak Beam"
Syarat:
M
c> 1,2
M
gp
u = Beban vertikal terfaktorMn = Momen nominal kolom sumbu "y" dari diagram interaksi
Mc = Jumlah Mn dua kolom yang bertemu di join
( M
ny.bawah+ M
ny.atas)
Mg = Jumlah Mn dua balok yang bertemu di join(
f
M
n
+
f
M
n+
) /
f
mutu beton,
f
c'
b=
29.1 MPaMutu baja tulangan longitudinal balok,
f
y=
400.0 MPaFaktor reduksi keuatan lentur,
f
=
0.9Mutu baja tulangan sengkang balok,
f
ys=
400.0 MPaMutu baja tulangan longitudinal untuk momen probable,
f
s= 1,25 * f
y=
500.0 MPa Faktor reduksi keuatan lentur untuk momen probable balok,f
=
1.0Tebal pelat lantai,
h
Pl=
130.0 mmTulangan pelat lantai, 10 - 150
6 D 22 6 D 22
3 D 22 3 D 22
Above Left: Above Right:
Length = 6.00 m Length = 6.00 m Width = bb = 300 mm Width = bb = 300 mm Depth = hb = 500 mm Depth = hb = 500 mm Be = 1340 mm Be = 1340 mm As = 2281 mm 2 Kolom Desain As = 1140 mm 2 As' = 2281 mm 2 As' = 1140 mm 2 As.pl = 1403 mm 2 As.pl = 1403 mm 2 Confin. = 10.0 mm Confin. = 10.0 mm sb = 40.0 mm sb = 40.0 mm fMn - = 310.2 kNm fMn - = 310.2 kNm fMn + = 167.6 kNm fMn + = 167.6 kNm fMpr = 413.3 kNm fMpr = 413.3 kNm fMpr + = 228.4 kNm fMpr + = 228.4 kNm KOLOM BALOK Axis ID Kolom Mny Mcy fMn - fM n + Mg 1,2 * Mg Ket. (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) X Sway to +X 600.0 1020.0 310.2 167.6 530.9 637.1 AMAN.!
Design Sway to -X 600.0 1020.0 310.2 167.6 530.9 637.1 AMAN.!
X Sway to +X 420.0 Above Sway to -X 420.0 bb hb Be sb
4.3. Persyaratan Tulangan Confinement
4.3.1 Menentukan daerah l0 (Pasal. 21.6.4.1)
Panjang efektif kolom,
L
n=
3400.0 mmTinggi penampang kolom,
h =
800.0 mmL0 di ambil sepanjang 1/ 6 Ln
1/6 * L
n=
566.7 mmL0 di ambil sepanjang 450 mm
=
450.0 mmYang terpanjang,
L
0.Max=
800.0 mmDiambil,
L
0=
800.0 mm4.3.2. Spasi tul. Tranversal di daerah l0 (Pasal. 21.6.4.3)
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmDiameter tulangan longitudinal terkecil,
D
b=
22.0 mmSelmut beton (Cover ),
sb =
40.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mm1/4 dimensi penampang kolom terkecil
1/4 * Min( b, h) =
100.0 mm 6 kali diameter tulangan longtudinal terkecil kolom6 * Min(D
b) =
132.0 mmh
x= 0,5 * (b - 2 * ( sb + D
s/ 2 ) =
153.5 mms
x= Max(100, 100 + ( 350 - h
x) / 3 ) =
165.5 mms
max=
150.0 mmDigunakan jarak sengkang,
s =
100.0 mm4.3.3 Pengekang Kolom (Ps. 21.6.4.4(b))
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPabcx xx1 xx2 bcy xy1 xy3 Ash.y Ash.x 6db > 75mm Perpanjangan 6db xy2 Ds sb Ds by bx
Mutu baja tulangan geser kolom,
f
yh=
400.0 MPa Lebar penampang inti beton terkekang,h
c1= h - ( 2 * ( sb + D
s/ 2 )) =
707.0 mm Luas penampang inti beton,A
ch= ( h - 2 * sb ) * ( b - 2 * sb ) =
230400.0 mm 2Total luas penampang hoop,
A
sh.y= 0,3 * [( s * h
c1* f
c' ) / f
yh] * [ ( A
g/ A
ch) - 1 ] =
599.0 mm2Total luas penampang hoop,
A
sh.y= 0,09 * [( s * h
c1* f
c' ) / f
yh] =
462.1 mm2 Dipakai Ash.perlu dengan nilai terbesar,A
sh.y Perlu=
599.0 mm2
Dipakai sengkang kolom,
13
-
100
Luas tulangan geser sengkang,
A
v=
p
/ 4 * D
s2=
132.7 mm2Jumlah tulangan,
n = A
sh/ A
s=
4.51Jumlah tulangan pengekang (Ties )
n
Pakai=
5.0Digunakan sengkang l0,
5
D
s13
-
100
Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
663.7 mm2
AMAN.!
4.4 Perencanaan Kebutuhan Tulangan Geser Kolom
4.4.1. Spasi tul. Geser di daerah l0
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2
Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan geser kolom,
f
ys=
400.0 MPaPanjang efektif kolom,
L
n=
3.4 mGaya geser maksimum hasil analisis,
V
umax. analisis=
265.0 kN Probable Momen y,M
pr.y= Max (M
pr+x, M
pr-x) =
641.7 kN.m Gaya geser berdasarkan Mpr balok,V
u.sway= M
pr.Max/ L
n=
188.7 kNMpr Kolom,
M
pr.kolom=
787.0 kN.mGaya geser akibat gempa,
V
e= ( 2 * M
pr.kolom) / L
n=
462.9 kN Gaya geser maksimum yang bekerja pada kolom,V
u=
265.0 kNV
e=
462.9 kN1 / 2 * V
u=
94.4 kN Vc = 0Tinggi efektif kolom,
d = b - sb - D
s- D/2 =
336.0 mmFaktor reduksi kekuatan geser,
f
=
0.75Kuat geser beton,
V
c= ( 1 + ( N
u/ (14 * A
g))) * (
f
c' / 6 ) * b
w* d =
0.0 kNTahanan geser beton,
f*
V
c=
0.0 kNDigunakan sengkang l0,
5
D
s13
-
100
Luas tulangan geser sengkang,
A
v= n
s*
p
/ 4 * P
2=
132.7 mm2Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
663.7 mm2
Tahanan geser sengkang aktual,
f
V
s=
f
( A
sh* f
y* d ) / s =
669.0 kNf
V
c+
f
V
s=
669.0 kN (OK, Ash terpasang cukup untuk menahan geser)4.4.2. Perencanaan Kebutuhan Tulangan Geser Kolom di luar l0
Gaya aksial tekan terkecil hasil kombinasi beban,
N
u= P
u.Min=
937.3 kN Gaya geser yang diperhitungkan di luar daerah l0,V
u=
265.0 kNLebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2
Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan geser kolom,
f
ys=
400.0 MPaTinggi efektif kolom,
d = b - sb - D
s- D/2 =
336.0 mmFaktor reduksi kekuatan geser,
f
=
0.75Kuat geser beton,
V
c= ( 1 + ( N
u/ (14 * A
g))) * ( f
c' / 6 ) * b
w* d =
650.9 kNTahanan geser beton,
f*
V
c=
488.1 kN
Hanya perlu tul.geser min Tahanan geser sengkang perlu,f*
V
s= V
u-
f*
V
c=
- kNKuat geser sengkang,
V
s=
265.0D+I474
sDigunakan sengkang berpenampang :
2
D
s13
Luas tulangan geser sengkang,
A
v= n
s*
p
/ 4 * P
2=
265.5 mm2 Jarak sengkang yang diperlukan,s = A
v* f
ys* d / ( V
s* 10
3
) =
9999.0 mmJarak sengkang,
s = d / 2 =
168.0 mmJarak sengkang maksimum,
s
max=
150.0 mmJarak sengkang yang harus digunakan,
s =
150.0 mm4.5 Hubungan Balok Kolom (HBK)
4.5.1. Kuat geser nominal Joint kolom
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmSelmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmPanjang efektif kolom,
L
n=
3.4 mFaktor reduksi kekuatan geser joint,
f
=
0.80Mutu beton kolom,
f
c' =
29.1 MPa(3/4).bw.kolom
3/ 4 * b
w.kolom=
300.0 mmMutu baja tulangan longitudinal kolom,
f
y.k=
400.0 MPa Mutu baja tulangan longitudinal balok,f
y.b=
400.0 MPaMutu baja tulangan longitudinal slab,
f
=
240.0 MPabb Be sb As.s1 As.1 As.s2 As.2 Ts.1 Tb.1 Ts.2 Vcol.1 Vu Cb.2 Vu Vcol.2 Tb.2 Cb.1
Tampak Joint Penampang Balok
hb Pu Muy Vu Pu Muy Vu As As' As fy As'fy As (1,25fy) As'(1,25 fy) 0,85 fc' b a 0,85 fc' b a
Sway Axis Be Ts Tb1 Tb2 Mpr -Mpr + Mu Vh (mm) (kN) (kN) (kN) (kNm) (kNm) (kNm) (kN) Sway to +X 1340.0 421.0 1140.4 570.2 413.3 228.4 320.8 188.7 Sway to -X 1340.0 421.0 1140.4 570.2 413.3 228.4 320.8 188.7
V
y-y + X= T
s+ T
b1+ T
b2- V
h=
1942.8 kNV
y-y - X= T
s+ T
b1+ T
b2- V
h=
1942.8 kNV
x-x.Max=
1942.8 kNJumlah balok yang menumpu di joint,
n
balok=
4.0Faktor jumlah kekangan balok pada joint,
c =
1.7Jarak ujung sisi balok ke ujung sisi kolom,
x =
250.0 mmTinggi penampang kolom,
h
j= h
c=
400.0 mmBatas Lebar efektif joint 1,
b
b+ h
j=
700.0 mmBatas Lebar efektif joint 2,
b
b+ 2 * x =
800.0 mmLebar efektif joint,
b
j.min=
700.0 mmLuas efektif joint,
A
j= b
j* h
j=
280000.0 mm2
Kuat geser joint,
f
V
c=
f
* (c *
f
c' * A
j) =
2052.4 kNSyarat :
f
* V
c≥
V
x-x.Max2052.44
>
1942.85
AMAN (OK)4.5.2. Tulangan confinement pada joint
Faktor reduksi kekuatan geser joint,
f
=
0.75Gaya geser pada joint,
V
u=
1942.8 kNTahanan geser beton pada joint,
f
V
c=
2052.4 kNTahanan geser sengkang perlu,
f*
V
s= V
u-
f*
V
c=
- kNKuat geser sengkang,
V
s=
0.0 kN.
h, tinggi pada join bidang tulangan penyebab tul. geser
.
Lebar efektif joint bb + h < bb + 2x
Gaya geser total yang bekerja pada joint,
V
u.total= V
y-y.max+ V
s=
1942.8 kNMutu baja tulangan sengkang balok,
f
y.s=
400.0 MPaTinggi efektif kolom,
d = b - sb - D
s- D/2 =
336.0 mmDigunakan sengkang di joint,
2
D
s13
-
100
Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
265.5 mm2
Tahanan geser sengkang aktual,
f
V
s=
f
( A
sh* f
y* d ) / s =
267.6 kNf
V
c+
f
V
s=
2320.0 kN Syarat :f
* V
c+
f
V
s≥
V
u.total2320.03
>
1942.85
AMAN (OK)E. TINJAUAN SEARAH SUMBU Y (Momen X : M
ux= M
2)
1. FAKTOR PANJANG TEKUK KOLOM
Searah.sb. Y :300 300
600
L
b.L=
7 600L
b.R=
7L
u=
3.4b = Y.axis = 500.0 Above Column h = X.axis = 400.0 300 300 600
L
b.L=
7 600L
b.R=
7L
u=
3.4 b = Y.axis = 800.0 Design h = X.axis = 400.0 300 300 600L
b.L=
7 600L
b.R=
7L
u=
2.4b = Y.axis = 800.0 Below Column h = X.axis = 400.0
Slenderness
Sway Criteria : Non-Sway Frame
Mutu beton kolom, 2
f
c' =
29.1 MPakolom Axis Height Width Depth Ix Ec EIk EIk / ℓu
(m) (mm) (mm) (mm4) MPa MPa
Design Y 3.40 400 800 1.7.E+10 3.E+04 3.E+14 8.9E+10
Above Y 3.40 400 500 4.2.E+09 3.E+04 7.E+13 2.2E+10
Below Y 2.40 400 800 1.7.E+10 3.E+04 3.E+14 1.3E+11
Mutu beton balok,
f
c' =
29.1 MPaY-Beams Length Width Depth I Ec Eib.y EIb.y / L
Location (m) (mm) (mm) (mm4
) MPa MPa
Above Left 7.00 300 600 5.4.E+09 3.E+04 5.E+13 6.8E+09
Above Right 7.00 300 600 5.4.E+09 3.E+04 5.E+13 6.8E+09
Below Left 7.00 300 600 5.4.E+09 3.E+04 5.E+13 6.8E+09
Below Right 7.00 300 600 5.4.E+09 3.E+04 5.E+13 6.8E+09
Effective Length Factors: Opsional K = 0.00
Axis Y(top) Y(bot) k(Nonsway) k(Sway) ℓu.y (mm) k ℓu / rx
Y 8.10 15.73 0.965 N/A 3400.0 14.21 hc bc x y Pu Mux Mux kolom Desain
Above Left Above Right
Vu Vu Pu Lu hb h pl bc Lb
2. KLASIFIKASI KOLOM & PEMBESARAN MOMEN
2.1 Menentukan Kolom Panjang Atau Pendek
Lebar kolom,
b =
400.0 mmtinggi kolom,
h =
800.0 mmTinggi efektif kolom,
L
u.y=
3400.0 mmInersia penampang kolom,
I
x= 1/12 * b * h
3=
1.7.E+10 mm4Luas tampang kolom Pier,
A
g= b * h =
320000 mm2Jari-jari inersia penampang kolom Pier,
r
x=
[ I
x/ A
g] =
230.9 mmFaktor panjang tekuk,
K
y=
0.965Angka kelangsingan,
K * ℓ
u.x/ r
x=
14.21Momen ultimate terkecil kolom,
M
1=
53.27 kNmMomen ultimate terbesar kolom,
M
2=
513.82 kNmM
1/ M
2=
-0.10 Double Curvatur Syarat batas kelangsingan,Kℓ
u/ r < 34 - 12 * ( M
1/ M
2) < 40 =
35.24Kolom Pendek Tidak Perlu Pembesaran Momen
2.2 Pembesaran Momen
Pengaruh buckling diperhitungkan dengan cara Perbesaran Momen pada kolom sbb.
Gaya aksial ultimit kolom,
P
u=
1991.96 kNBeban mati ultimit pada kolom :
P
u_DL= 1,2 DL =
1443.60 kN Beban hidup ultimit pada kolom :P
u_LL= 1 LL =
403.00 kN Nilai perbandingan beban mati ultimit terhadap beban tetap ultimit :Mutu beton kolom,
f
c' =
29.1 MPaMutu beton kolom,
E
c= 4700 *
f
c' =
25332.1 MPaβ
d= DL / (DL + LL) =
0.782Kekakuan lentur kolom,
EI = 0.4 * E
c* I
x/ (1 + β
d) =
97057.7 kNm 2Beban aksial kritis,
P
c=
p
2
* EI / ( K * ℓ
u.x)
2=
88832.3 kN With Transversal loadC
m= 0,6 + 0,4 * ( M
1/ M
2) atau 1 =
1.00Faktor perbesaran momen,
d
s= C
m/ [ 1 - P
u/ (0.75 * P
c) ] =
1.00Momen ultimate minimum,
M
2,Min= P
u* ( 15,24 + 0,03 * h ) =
78.16 kNm Momen ultimate,M
ux= Max(M
2; M
2min) =
513.82 kNm3. REKAP GAYA AXIAL & MOMEN ULTIMATE
Load Pu Mux Mux Mnx Comb (kNm) (kNm) (kNm) (kNm) U1 1684 386 513.8 1535 U2 2088 348 1396 U3 1645 336 1353 U4 1444 331 1339 U5 1444 331 1339 U6 1645 336 1353 U7 1645 336 1353 U8 1645 336 1353 U9 1645 336 1353 U10 1284 253 1296 U11 1284 253 1296 U12 1985 456 1381 U13 1975 288 1380 U14 955 301 1267 U15 945 134 1267 U16 1967 290 1385 U17 1992 514 1381 U18 937 215 1253 U19 962 360 1250 Envelove Max 2088.4 513.8 1535.0 Envelove Min 937.3 134.0 1250.04. DESAIN KOLOM SRPMK
4.1. Persyaratan Dimensi Kolom
Lebar penampang kolom,
b =
400.00 mmTinggi penampang kolom,
h =
800.00 mmGaya aksial ultimit kolom terkecil,
P
u.Min=
937.34 kNLuas tampang kolom,
A
g= b * h =
320000.00 mm2
Kuat tekan beton,
f
c' =
29.05 MPa- Gaya Akxial terfaktor maksimum yang bekerja pada kolom harus menenuhi Ag * fc' /10
A
g* f
c' /10 =
929.60 kNAMAN.!
Penampang kolom terkecil tidak kurang dari 300 mm
b =
400.00 mm AMAN.!Rasio dimensi penampang tidak kurang dari 0,4
b / h =
0.50 AMAN.! Rasio tulangan kolom 1% < r < 6%r
= ( A
s/ b * h ) * 100 =
2.61AMAN.! Cek pengaruh efek beban gempa ortogonal,
P
umax.Qe=
30.10 kNf
P
n.max= 0,8 *
f
* [ 0,85 * f
c' * (A
g- A
st) + f
y* A
st] =
5740.94 kNP
umax.Qe <20 %
f
P
n.max Abaikan.!4.2. Persyaratan "Strong kolom Weak Beam"
Syarat:
M
c> 1,2
M
gp
u = Beban vertikal terfaktorMn = Momen nominal kolom sumbu "x" dari diagram interaksi
Mc = Jumlah Mn dua kolom yang bertemu di join
( M
nx.bawah+ M
nx.atas)
Mg = Jumlah Mn dua balok yang bertemu di join(
f
M
n
+
f
M
n+
) /
f
mutu beton,
f
c'
b=
29.1 MPaMutu baja tulangan longitudinal balok,
f
y=
400.0 MPaFaktor reduksi keuatan lentur,
f
=
0.9Mutu baja tulangan sengkang balok,
f
ys=
400.0 MPaMutu baja tulangan pelat lantai,
f
ysb=
240.0 MPaMutu baja tulangan longitudinal untuk momen probable,
f
s= 1,25 * f
y=
500.0 MPa Faktor reduksi keuatan lentur untuk momen probable balok,f
=
1.0Tebal pelat lantai,
h
Pl=
130.0 mmTulangan pelat lantai, 10 - 150
7 D 22 7 D 22
4 D 22 4 D 22
Above Left: Above Right:
Length = 7.00 m Length = 7.00 m Width = bb = 300 mm Width = bb = 300 mm Depth = hb = 600 mm Depth = hb = 600 mm Be = 1340 mm Be = 1340 mm As = 2661 mm 2 Kolom Desain As = 1521 mm 2 As' = 2661 mm 2 As' = 1521 mm 2 As.pl = 1403 mm 2 As.pl = 1403 mm 2 Confin. = 10.0 mm Confin. = 10.0 mm sb = 40.0 mm sb = 40.0 mm fMn - = 445.9 kNm fMn - = 445.9 kNm fMn + = 272.6 kNm fMn + = 272.6 kNm fMpr = 595.4 kNm fMpr = 595.4 kNm fMpr + = 326.4 kNm fMpr + = 326.4 kNm KOLOM BALOK Axis ID Kolom Mnx Mcx fMn - fM n + Mg 1,2 * Mg Ket. (kNm) (kNm) (kNm) (kNm) (kNm) (kNm) Y Sway to +Y 1250.0 2125.0 445.9 272.6 798.3 957.9 AMAN.!
Design Sway to -Y 1250.0 2125.0 445.9 272.6 798.3 957.9 AMAN.!
Y Sway to +Y 875.0 Above Sway to -Y 875.0 bb hb Be sb
4.3. Persyaratan Tulangan Confinement
4.3.1 Menentukan daerah l0 (Pasal. 21.6.4.1)
Panjang efektif kolom,
L
n=
3400.0 mmTinggi penampang kolom,
h =
800.0 mmL0 di ambil sepanjang 1/ 6 Ln
1/6 * L
n=
566.7 mmL0 di ambil sepanjang 450 mm
=
450.0 mmYang terpanjang,
L
0.Max=
800.0 mmDiambil,
L
0=
800.0 mm4.3.2. Spasi tul. Tranversal di daerah l0 (Pasal. 21.6.4.3)
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmDiameter tulangan longitudinal terkecil,
D
b=
22.0 mmSelmut beton (Cover ),
sb =
40.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mm1/4 dimensi penampang kolom terkecil
1/4 * Min( b,h) =
100.0 mm 6 kali diameter tulangan longtudinal terkecil kolom6 * Min(D
b) =
132.0 mmh
x= 0,5 * (b - 2 * ( sb + D
s/ 2 ) =
153.5 mms
x= Max(100, 100 + ( 350 - h
x) / 3 ) =
165.5 mms
max=
150.0 mmDigunakan jarak sengkang,
s =
100.0 mmbci xi xi xi bc2 xi xi Ash.x Ash.y 6db > 75mm Perpanjangan 6db bx by sb Ds D
4.3.3 Pengekang Kolom (Ps. 21.6.4.4(b))
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2
Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan geser kolom,
f
yh=
400.0 MPaLebar penampang inti beton yang terkekang,
h
c2= b - ( 2 * sb - D
s/ 2 ) =
313.5 mm Luas penampang inti beton,A
ch= ( b - 2 * sb ) * ( h - 2 * sb ) =
230400.0 mm 2Total luas penampang hoop,
A
sh.x= 0,3 * [( s * h
c2* f
c' ) / f
yh] * [ ( A
g/ A
ch) - 1 ] =
265.6 mm2Total luas penampang hoop,
A
sh.x= 0,09 * [( s * h
c2* f
c' ) / f
yh] =
204.9 mm2 Dipakai Ash.perlu dengan nilai terbesar,A
sh.x Perlu=
265.6 mm2
Dipakai sengkang kolom,
13
-
100
Luas tulangan geser sengkang,
A
v=
p
/ 4 * D
s2=
132.7 mm2Jumlah tulangan,
n = A
sh/ A
s=
2.00Jumlah tulangan pengekang (Ties )
n
Pakai=
3.0Digunakan sengkang l0,
3
D
s13
-
100
Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
398.2 mm2
AMAN.!
4.4 Perencanaan Kebutuhan Tulangan Geser Kolom
4.4.1. Spasi tul. Geser di daerah l0
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2
Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan geser kolom,
f
ys=
400.0 MPaPanjang efektif kolom,
L
n=
3.4 mGaya geser maksimum hasil analisis,
V
umax. analisis=
174.7 kN Probable Momen x,M
pr.x= Max (M
pr+x, M
pr-x) =
921.7 kN.m Gaya geser berdasarkan Mpr balok,V
u.sway= M
pr.Max/ L
n=
271.1 kNGaya geser akibat gempa,
V
e= ( 2M
pr.kolom Max) / L
n=
938.8 kN Gaya geser maksimum yang bekerja pada kolom,V
u=
271.1 kNV
e=
938.8 kN1 / 2 * V
u=
135.5 kN Vc = 0P
u.Min=
937.3 kN0,05 * (A
g* f
c' ) =
464.8 kN Perhitungkan Vc Tinggi efektif kolom,d = h - sb - D
s- D/2 =
736.0 mmFaktor reduksi kekuatan geser,
f
=
0.75Kuat geser beton,
V
c= ( 1 + ( N
u/ (14 * A
g))) * ( f
c' / 6 ) * b
w* d =
0.0 kNTahanan geser beton,
f*
V
c=
0.0 kNDigunakan sengkang l0,
3
D
s13
-
100
Luas tulangan geser sengkang,
A
v= n
s*
p
/ 4 * P
2=
132.7 mm2Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
398.2 mm2
Tahanan geser sengkang aktual,
V
s=
f
( A
sh* f
y* d ) / s =
879.2 kNf
( V
c+ V
s) =
879.2 kN (OK, Ash terpasang cukup untuk menahan geser)4.4.2. Perencanaan Kebutuhan Tulangan Geser Kolom di luar l0
Gaya aksial tekan terkecil hasil kombinasi beban,
N
u= P
u.Min=
937.3 kN Gaya geser yang diperhitungkan di luar daerah l0,V
u=
271.1 kNLebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmLuas penampang kolom,
A
g= b * h =
320000.0 mm2Selmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan geser kolom,
f
ys=
400.0 MPaTinggi efektif kolom,
d = h - sb - D
s- D/2 =
736.0 mmFaktor reduksi kekuatan geser,
f
=
0.75Kuat geser beton,
V
c= ( 1 + ( N
u/ (14 * A
g))) * ( f
c' / 6 ) * b
w* d =
1425.7 kNTahanan geser beton,
f*
V
c=
1069.3 kN
Hanya perlu tul.geser min Tahanan geser sengkang perlu,f*
V
s= V
u-
f*
V
c=
- kNKuat geser sengkang,
V
s=
271.1 kNDigunakan sengkang berpenampang :
2
P
13
Luas tulangan geser sengkang,
A
v= n
s*
p
/ 4 * P
2=
265.5 mm2 Jarak sengkang yang diperlukan,s = A
v* f
ys* d / ( V
s* 10
3
4.5 Hubungan Balok Kolom (HBK)
4.5.1. Kuat geser nominal Joint kolom
Lebar penampang kolom,
b =
400.0 mmTinggi penampang kolom,
h =
800.0 mmSelmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmPanjang efektif kolom,
L
n=
3.4 mFaktor reduksi kekuatan geser joint,
f
=
0.80Mutu beton kolom,
f
c' =
29.1 MPa(3/4).bw.kolom
3/4 * b
w.kolom=
300.0 mmMutu baja tulangan longitudinal kolom,
f
y.k=
400.0 MPa Mutu baja tulangan longitudinal balok,f
y.b=
400.0 MPa Mutu baja tulangan longitudinal slab,f
y.s=
240.0 MPabb Be sb As.s1 As.1 As.s2 As.2 Ts.1 Tb.1 Ts.2 Vcol.1 Vu Cb.2 Vu Vcol.2 Tb.2 Cb.1
Tampak Joint Penampang Balok
hb Pu Muy Vu Pu Muy Vu As As' As fy As'fy As (1,25fy) As'(1,25 fy) 0,85 fc' b a 0,85 fc' b a
Sway Axis Be Ts Tb1 Tb2 Mpr -Mpr + Mu Vh (mm) (kN) (kN) (kN) (kNm) (kNm) (kNm) (kN) Sway to +Y 1340.0 421.0 1330.5 760.3 595.4 326.4 460.9 271.1 Sway to -Y 1340.0 421.0 1330.5 760.3 595.4 326.4 460.9 271.1
V
y-y + Y= T
s+ T
b1+ T
b2- V
h=
2240.6 kNV
y-y - Y= T
s+ T
b1+ T
b2- V
h=
2240.6 kNV
y-y.Max=
2240.6 kNJumlah balok yang menumpu di joint,
n
balok=
4.0Faktor jumlah kekangan balok pada joint,
c =
1.7Jarak ujung sisi balok ke ujung sisi kolom,
x =
50.0 mmTinggi penampang kolom,
h
j= b
c=
800.0 mmBatas Lebar efektif joint 1,
b
b+ h
j=
1100.0 mmBatas Lebar efektif joint 2,
b
b+ 2 * x =
400.0 mmLebar efektif joint,
b
j.min=
400.0 mmLuas efektif joint,
A
j= b
j* h
j=
320000.0 mm2
Kuat geser joint,
f
V
c=
f
* (c *
f
c' * A
j) =
2345.6 kNSyarat :
f
* V
c≥
V
y-y.Max2345.64
>
2240.61
AMAN (OK).
h, tinggi pada join bidang tulangan penyebab tul. geser
.
Lebar efektif joint bb + h < bb + 2x
4.5.2. Tulangan confinement pada joint
Faktor reduksi kekuatan geser joint,
f
=
0.75Gaya geser pada joint,
V
u=
2240.6 kNTahanan geser beton pada joint,
f
V
c=
2345.6 kNTahanan geser sengkang perlu,
f*
V
s= V
u-
f*
V
c=
- kNKuat geser sengkang,
V
s=
0.0 kNGaya geser total yang bekerja pada joint,
V
u.total= V
y-y.max+ V
s=
2240.6 kNMutu baja tulangan sengkang balok,
f
y.s=
400.0 MPaTinggi efektif kolom,
d = h - sb - D
s- D/2 =
736.0 mmDigunakan sengkang di joint,
2
D
s13
-
100
Dipakai Ash pakai,
A
sh.Pakai= n * A
v=
265.5 mm2
Tahanan geser sengkang aktual,
f
V
s=
f
( A
sh* f
y* d ) / s =
586.1 kNf
V
c+
f
V
s=
2931.8 kN Syarat :f
* V
c+
f
V
s≥
V
u.total2931.79
>
2240.61
AMAN (OK)6.4. PENYALURAN SAMBUNGAN TULANGAN VERTIKAL
Lebar penampang kolom,
b =
400.0 mmSelmut beton (Cover ),
sb =
40.0 mmDiameter tulangan longitudinal kolom,
D =
22.0 mmDiameter tulangan geser kolom,
D
s=
13.0 mmMutu beton kolom,
f
c' =
29.1 MPaMutu baja tulangan longitudinal kolom,
f
y.k=
400.0 MPaa
=
1.0b
=
1.0g
=
1.0l
=
1.0K
tr= (40 * A
tr) / s * n =
0.0c = sb + D
s+ D/2 =
64.0 mmc = ( b - 2 * ( sb + Ds ) - D ) / 6 * 2 =
22.7 mm( c + K
tr) / d
b=
1.0 mm < 2,5=
1.0 Pasal 12.15.1l
d= ( 9 * f
y/ 10 *
f
c' ) * ((
a*b*g*l
) / ((c + K
tr) / D )) * D =
1426.2 mml
d= sambungan kelas A
l
d=
1426.2 mm1,3 * l
d= sambungan kelas B
1,3 * l
d=
1854.1 mm Dipakai Kelas A=
1426.2 mm=
1500.0 mmTUL. POKOK TUL. SENGKANG POTONGAN 22 D 22 5 D 13 - 100 SUMBU X TUL. POKOK TUL. SENGKANG POTONGAN SUMBU X TUL. POKOK TUL. SENGKANG POTONGAN SUMBU X POTONGAN UNTUK DAERAH L0 = 800 mm POTONGAN
UNTUK DAERAH LUAR L0
POTONGAN
UNTUK DI JOINT
SUMBU Y SUMBU Y SUMBU Y
2 D 13 - 150 22 D 22 22 D 22 2 D 13 - 100 0 100 200 300 400 500 600 700 800 0.0 200.0 400.0 600.0 800.0 0 100 200 300 400 500 600 700 800 0.0 200.0 400.0 600.0 800.0 0 100 200 300 400 500 600 700 800 0.0 200.0 400.0 600.0 800.0 0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800