OMNIA_D A S_EN_0 0_03/20 13

OMNIALOG

DATA ACQUISITION SYSTEMS

OMNIAlog data aquisition system is designed to be versatile and flexible. By adding modular components the system can be configured to handle the simplest or the most complex projects.

A single logger, housed in a cabinet with multiplexer expansion boards and a communication interface, can manage a large number of sensors. OMNIAlog system is easily adapted for many application, such as tunnels or dams by using external multiplexer boxes. Such distributed system can be connected in a daisy chain or in a star configuration. Recorded data can be downloaded via USB memory stick or pushed to remote servers by ftp and telecommunications. Alerts can be sent by email and graphs and reports can be generated on web pages to access anywhere.

APPLICATIONS

• Tunnelling • Dam surveillance • Structural monitoring • Mining exploration • Deep excavation • Landslide safety implementation • Retaining walls • Geotechnical investigation campaigns

FEATURES

• Installation allowed in

unattended areas or hard environment conditions

• Rated for wide temperature

range

• Compatible with all major

geotechnical sensors, both analogues and digitals

• 2 GB internal memory

• Stand alone or part of a network

• Built - in vibrating wire interface

OMNIA_D

A

S_EN_04_06/20

(3)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

DAMS

AND HPP

These projects usually require many different types of sensors. Instrument cables can be connected at MUX boxes and read with portable readouts in the first phase. In the second phase, the MUX boxes can be connected to OMNIAlog datalogger in the control room by special cables.

TUNNELS

AND MINES

For tunnelling applications, data acquisition systems must be easily reconfigured. OMNIAlog system offers a wide variety of communication interfaces that are easy to change. In addition, MUX boxes can be used as temporary manual reading stations and later connected to a logger.

MAIN REFERENCES FOR DAMS AND HYDRO POWER PROJECTS:

Cahora Bassa HPP, Mozambique - Hidroelectrica de Cahora Bassa

Neckartal Dam and Bulk Water, Namibia - Salini Namibia PTY LTD Azad Dam, Iran - Sadafzar

Hozian Dam, Iran - Lorestan Water Authorities

UMA OYA Multitipurpose Project, Sri Lanka - Ministry of Irrigation and Water Resources Metolong Dam, Lesotho - Sinohydro Corporation LTD

Kufranja Dam, Jordan - Società Italiana per Condotte d’Acqua SpA

Mavrovo Dam, Tikves Dam, Globocica Dam, Spilje Dam, Macedonia - ELEM Nam Gnouang Dam, Laos - CMC Ravenna - Vientiane - Lao PDR

Cerro del Águila Hydroelectric power plant, Perù - ASTALDI S.p.A. Sucursal del Perú Qanouna Dam, Saudi Arabia - Envirotec International Co. LTD.

MAIN REFERENCES FOR TUNNELS, MINES AND UNDERGROUND WORKS:

L.A. Subway Purple Line Extension, California USA - Analysis and Solutions Consultants Mikhailovskiy mine, Russia - GPIKO LTD

Grand Paris Metro, France - Various Customers Aitik mine, Sweden - Boliden Mineral AB

Lima Metro Line 1, Perù - Applus Norcontrol PERU’ MRT Orange Line E1, Thailand - Sisgeo Asia Pacific Co., Ltd

Riyadh Metro, Saudi Arabia - Environmental Mechanism Trading Establishment Doha Metro, Qatar - Soletanche Bachy

Stratoni Mine, Greece - Hellas Gold SA

Warsaw Metro Project, Poland - AGP Metro Polska Brenner Tunnel, Italy / Austria - GD Test Srl

(4)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

HISTORICAL AND

CIVIL STRUCTURES

OMNIAlog components can be installed at any location in the structure to collect readings from the installed instruments. If a local LAN network already exists, OMNIAlog can be connected to it, creating a centralized on-line system automatically. No other interfaces are needed.

LANDSLIDES AND

MOBILITY

INFRASTRUCTURES

In remote locations, monitoring is simplfied by using a GPRS modem or a 4G router. OMNIAlog can be installed at different locations in a landslide area or along a railway or motorway, collecting readings from sensors and transmitting them to a central location for real-time processing and alerting.

MAIN REFERENCES FOR HISTORICAL BUILDINGS AND CIVIL STRUCTURES:

Semey Sports Arena, Kazakhstan - BAYS LLP

Morandi Bridge monitoring, Genova, Italy - Field Srl Bosphorous Third Bridge, Turkey - Sisgeo Zemin Astana Ice Palace, Kazakhstan - Bays LLC

Sochi Central Olympic Stadium, Russia - LLC Geocommerce Barcelona Airport, Spain - Applus Norcontrol

Saint Helena new Airport, St. Helena Island - Basil Read Ltd

Astana National Library, Kazakhstan - Monitoring System Group LLP Patras Port, Greece - Aktor SA

Algeri Mosque, Algeria - Trevi SpA

Moscow City Plot 11 Skyscraper, Russia - LLC Geocommerce

MAIN REFERENCES FOR LANDSLIDES AND MOBILITY INFRASTRUCTURES:

Highway West Georgia Landslide monitoring, Georgia - Hydrodiagnostics LTD

Amsterdam Schiphol Airport, Netherlands - Zensor NV

Wien Sanierung Parlament, Austria - Meixner Vermessung ZT GMBH Maratea Landslide, Italy - SMA SpA

Ionia Motorway, Greece - Dragados SA and Ferrovial Agroman SA Various Landslide monitoring in Sochi, Russia - AGT Systems Sibiu Landslide, Romania - Astaldi SpA

Yapi Merkezi Asia Transition Box, Turkey - Sisgeo Zemin Miglionico Landslide, Italy - SMA SpA

Oued Tlelat-Tlemcen railway, Algerie - Società Italiana Condotte d’Acqua Spa Stuttgard Landslide, Germany - Geomesstec

(5)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

DATALOGGER CABINET

0OMNCAB2000

CAB2 is a compact cabinet ready to house OMNIAlog modules. It includes a IP65

polycarbonate enclosure with mounting brackets, a 12V 7Ah battery, USB memory stick and a LAN cable for local connection to the PC. The system can be powered by AC mains or by a solar power kit.

OMNIAlog module (Not included) Backup battery

Connector for power supply Cable gland for instrument cables

Included Optional

Communication interface area

Reserved area for oneof the following devices:

- 1 or 2 multiplexer boards for analogue instruments (0OMN24MUX00) - 1 digital instruments power supply and wiring board (0OMX24V100W) - 1 wiring board for 4 chains of external multiplexers (0OMX4MUXEXT)

Datalogger (1)

Enclosure Backup battery

Number of MUX boards supported Installation

Instrument cable input

On board communication ports Display and keyboard

OMNIAlog module GT-816 or GT2400 or GT-100D

Lockable polycarbonate IP65 box, 500x400x200 mm (HxLxW). Customized enclosures are available 12V 7Ah. Not installed if the system is powered by solar panel kit

Up to 2 internal mux or up to16 external MUX. 16 total MUX. (Not allowed with OMNIAlog GT-100D) Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame M63 cable gland. Customized cable glands are available on request

LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS232 port (GPRS modem only) Backlight LCD 128x64 dpi with membrane keyboard for simple local management without PC

(1) refer to OMNIAlog datasheet for further information and specifications

400 mm 50 0 mm 1 1 2 2 3 3 4 5 6 6 5

TECHNICAL

SPECIFICATIONS

4

(6)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

DATALOGGER CABINET

0OMNCAB3000

CAB3 is a cabinet ready to house OMNIAlog modules with room for internal expansion. It includes a high quality and durable IP65 stainless steel enclosure which is installed on a wall or support frame, a rack for up to 3 multiplexer boards, a 12V 7Ah battery, a USB memory stick and a LAN cable for local connection to the PC.

The system can be powered by AC mains or by a solar power kit.

OMNIAlog module (Not included) Backup battery

Cable gland

Communication interface area

Rack for up to 3 multiplexer boards (0OMN24MUX00)

Reserved area for one of the following devices: - 1 digital instruments kit (0OMX24V100W)

- 1 4 - chain mux box wiring board (0OMX4MUXEXT)

600 mm 40 0 mm Datalogger(1) Enclosure Backup battery

Number of MUX boards supported Installation

On board communication ports Display and keyboard

OMNIAlog module GT-816 or GT2400 or GT-100D

Lockable stainless steel IP65 box, 400x600x250 mm (HxLxW). Customized enclosures are available 12V 7Ah. Not inserted if supplied with solar panel kit

Up to 3 internal MUX (24 channels each), up to 13 external MUX (24 channels each). 16 total MUX. (Not allowed with OMNIAlog GT-100D)

Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS-232 port (GPRS modem only) Backlight LCD 128x64 dpi with membrane keyboard for simple local management without PC

(1) refer to OMNIAlog datasheet for further information and specifications

1 1 2 2 3 3 4 4 5 6 6 Included Optional 5

TECHNICAL

SPECIFICATIONS

(7)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

DATALOGGER CABINET

0OMNCAB8000

CAB8 is a cabinet ready to house OMNIAlog modules. It supports both internal and external multiplexer expansion boards. The CAB8 includes a high quality and durable IP65 stainless steel enclosure with wall mounting brackets, a rack for up to 8 multiplexer boards, a 12V 7Ah battery, a USB memory stick and a LAN cable for local connection to the PC. The system is powered by AC mains or by a solar panel kit.

OMNIAlog module (Not included) Backup battery

Cable glands, ID Ø 42 mm

Communication interface area

Rack for up to 8 multiplexer boards (0OMN24MUX00)

1 digital instruments kit (0OMX24V100W)

4-chain mux box wiring board area (0OMX4MUXEXT)

TECHNICAL

SPECIFICATIONS

600 mm 60 0 mm Datalogger(1) Enclosure Backup battery

Number of MUX boards supported Installation

On board communication ports Display and keyboard

OMNIAlog module GT-816 or GT2400 or GT-100D

Lockable stainless steel IP65 box, 600x600x250 mm (HxLxW). Customized enclosures available. 12V 7Ah. Not inserted if supplied with solar panel kit

Up to 8 internal MUX (24 channels each), up to 8 external MUX (24 channels each). 16 total MUX. (Not allowed with OMNIAlog GT-100D)

Enclosure has 4 brakets for wall mounting. Compatible with 0AX0SH15X80 support frame LAN port (10/100 Mbps, RJ45), USB port (2.0, pen drive only), RS-232 port (GPRS modem only) Backlight LCD 128x64 dpi with membrane keyboard for minimal management without PC

(1) refer to OMNIAlog datasheet for further information and specifications

1 2 3 4 4 5 5 6 7 7 1 2 6 3 Included Optional

(8)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

APPLICATION IN COMPLEX

DISTRIBUTED ARCHITECTURE

PHASE 1

PHASE 2

Max 1200m

OMNIALOG CABINET

EXTERNAL MUX BOX

0OMN48MUXB0

INSTRUMENTS AND

MULTICORE CABLES

EXTERNAL MUX BOX

0OMN24MUXB0

EXTERNAL MUX BOX

0OMN24MUXB0

JUMPER CABLE

0ECAV10MUX0

MUX CABLE

0WE610MUXZH

MUX CABLE

0WE610MUXZH

EXTERNAL MUX BOX

0OMN24MUXB0

INTERNAL MUX

0OMN24MUX00

MUX WIRING BOARD

0OMX4MUXEXT

Instruments are installed and wired to multiplexer boxes that serve as a temporary reading stations. The New Leonardo portable readout, connected by a special cable, can operate the multiplexer and collect readings by clicking a button.

Multiplexer boxes are connected to OMNIAlog cabinet system which then manages all the instruments wired to the MUX boxes. OMNIAlog cabinet system can also manage internal multiplexer boards and chains of digital sensors.

NEW LEONARDO

0CDL400N000

(9)

OMN_DAS

OMNIA_D A S_EN_05_1 1/2020

COMMUNICATION INTERFACES

POWER SUPPLY UNITS

SUPPORT FRAME

0AX0SH15X80

Galvanized steel mounting frame compatible with all OMNIAlog cabinets.

MAINS POWER SUPPLY

0AXBCO22058

AC/DC charger, IP67 Oper. temp. -25 to +60°C Vin 90-264 Vac, 47-63 Hz Vout 13.2 Vdc, 2.1 A.

SOLAR PANEL PACKAGE

0AX00W000AH

Solar panel power supply for pole mounting. It includes solar panel, battery with regulator, and support brackets.

POLE FOR SOLAR PANEL

0AX0PALO280

Floor -mounted 3m pole with base plate for solar panel kit. Also available for mounting on support frame mod. 0AX0SH0PALO.

VPN 4G ROUTER

0OMXRO4G000

4G-VPN advanced router for fast connection, required when internet service provider does not support static IP addresses and inbound/outbound data traffic. Automatic fall-back to 3G network. For pushing data via ftp or email. Allowed allarms: email and ftp.

Three models are available to fit all the 4G bands worldwide: bands list are available in SISGEO website - F.A.Q.#108.

EXPANSION DEVICES

DC/DC 12/24V converter and wiring board for expanding up to:

- 250 digital sensors,100 W - 60 digital sensors, 60 W

both distributed in 4 chains maximum.

DIGITAL SENSOR KITS

0OMX24V100W-

0OMX24V030W

24 channel relay multiplexer with surge arrestors for each channel.

24 CH MUX BOARD

0OMN24MUX00

24 channel relays multiplexer, housed in IP65 polycarbonate box (300x300x180mm) including surge arrestors for each channel.

24 CH MUX BOX

0OMN24MUXB0

48 channel relays multiplexer, housed in IP65 polycarbonate box (400x300x180mm) including surge arrestors for each channel.

48 CH MUX BOX

0OMN48MUXB0

OMNIAlog cabinet pole for support frame support frame solar panel battery package

EXAMPLE OF OMNIALOG CABINET MOUNTED ON SUPPORT FRAME AND POWERED WITH SOLAR PANEL KIT

FIBER OPTIC INTERFACE

0OMXFOMMSWT

Switch ethernet with multimode optical fiber ports for in/out (max 4 jumps). Available only upon request.

3G MODEM

0OMXMODEM3G

3G dual-band modem, antenna and 10m cable. For pushing data via ftp or email. Allowed allarms: sms, email and ftp. 2G network compatible.

(10)

OMN_DAS

OMNIA_D A S_EN_0 0_03/20 13

OMNIALOG

SOFTWARE

OMNIAlog software is built into the OMNIAlog. With a simple web browser, user can configure the logger, download data, set alarm thresholds and view graphs. The OMNIAlog user interface is written in HTML and is compatible with all browsers. No other software is needed. Once logged into the OMNIAlog module, users see a banner with icons showing logger status, alarms, availability of firmware updates, power supply, and local date/time. A menu on the left side, lets the user navigate to all the logger functions. OMNIAlog software is available in English, Italian and French languages.

Acquisition configuration time intervals Local channel configuration

(11)

OMN_DAS

OMNIA_D

A

S_EN_05_1

1/2020

All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l. We reserve the right to change our products without prior notice. The datasheet is issued in English and other languages.

In order to avoid discrepancies and disagreement on the interpretation of the meanings, Sisgeo Srl declares that English Language prevails.

SISGEO S.R.L.

Via F. Serpero 4/F1 20060 Masate (MI) Italy Phone +39 02 95764130 Fax +39 02 95762011 info@sisgeo.com

TECHNICAL ASSISTANCE

SISGEO offers customers e-mail and phone assistance to ensure proper use

of instruments and readout and to maximize performance of the system.

For more information, please refer to the FAQ pages on our website

or email us: assistance@sisgeo.com

OMNIALOG COMMUNICATION FEATURES

INTERFACE OMNIAlog without communication interface OMNIAlog with 0OMXMODEM3G 3G modem OMNIAlog with 0OMXRO4G000

4G-VPN router

INTERFACE

OMNIAlog with 3G modem OMNIAlog with INTERNET

ROUTER 4G-VPN

LOCAL DATA DOWNLOAD

LAN OR USB FLASHDRIVE

LAN OR USB FLASHDRIVE

LAN OR USB FLASHDRIVE

NORTH AMERICA / CANADA COMPATIBILITY

NO YES, choose for 0OMXRO4G0NA

model

ALARMS

DATA PUSHING REMOTE

CONNECTION EMAIL NO YES YES NO NO

(only in emergency case)

YES EMAIL NO YES YES SMS NO YES NO FTP NO YES YES FTP NO YES YES

NOTE: all of these features may not work if the ISP selected by the user blocks these types of services. It is always customer responsibility to make sure that the SIM used enables these services.

References

Related documents

Teleport questions with parents is it phrase is important to do they are better understand grammar quiz and relative clause and organize your team has a quizizz.. Nailed it to use

Logic-level input signal used to control the charging mode, current limit threshold, and load detection, see the control truth table.. Can be tied directly to IN or GND

He reported a high and positive (0.77 to 0.98) genetic correlations between body weight at different ages from dam and sire plus dam components of variance; and the

(b) To polymerize MMA in the presence of PMMA at room temperature by addition of a redox pair (double radical initiator) [benzoyl peroxide (BP) - dimethyl

Using our best calculations BLYP/cc-pVTZ, recommended for organic molecules, the accuracy of determining bond lengths involving hydrogen atoms from HAR is better than 0.009 A °

After creating the metadata for an entity type, you can use the Generate Jobs option from the entity type editor toolbar to create and publish jobs to the DataFlux Data

• Nitrocellulose membrane is placed  on the gel.  The actual  blotting process may be active (electroblotting) or passive  (capillary). 

The use of duality of structure from the perspective of Structuration Theory (ST) was useful in understanding how events and activities were produced and reproduced overtime and