CODES/STANDARDS USA

265 265

1B1

CODES/STANDARDS-CSA/CMVSS 1B1

52G GEN-3.6KW ONAN LP MICROQUIET 7

X-X

FOR ELECTRICAL

CALLOUTS SEE DWG NO.

121339-01-000 FOR ELECTRICAL

TORQUE

SPECIFICATIONS SEE DWG NO.

128783-01-000

GEN-3.2 KW ONAN DIESEL 33F

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000 WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12U.

6

3.

4.

5

2.

SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS.

USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

1.

7

RCP-2 (BLU) EXT COMPT

7

AA

UNSPECIFIED TOLERANCES: MATERIAL:

C D

TWO-PLACE (X.XX) DSNR:

DESCRIPTION:

B

ALL DIMENSIONS ARE IN MILLIMETERS DFTR:

A

FIRST USED:

A

REV WHOLE DIM (X)

D

ITEM/PART NO:

WEIGHT: (LBS)

SHEET:

B

REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES

ANGLE

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

WIRING INSTL-BODY,110V 1

OF

5 000033161 / 31758901000

3 1.5 0.50 1

18 524D

500 DROP (GND)

FROM LOAD CENTER TO CHASSIS GROUND BOLT

6

33F

33F 10 GA WIRE FROM GEN

RCP TO GENERATOR

GENERATOR CABLE ASM

TO GENERATOR

CLAMP

10497-10-000 (3) SCREW

G39-08-12U (3)

OR 33F

7

52G 52G

TO GENERATOR

52G 10 GA WIRE FROM

POWER CORD 4X4 BOX TO LOAD CENTER

INVERTER-1000W, NO TRANSFER 000033749 / 318692-01-000 SCREW

G39-10-16U (4)

CLAMP

10497-10-000 (3) SCREW

G11-10-12U (3)

CLAMP

10497-01-000 SCREW

G11-10-12U

VIEW

AA

SWITCH-TRANSFER,INVERTER, 15 AMP 000033766 / 318693-01-000

SCREW

G67-10-12U (2)

7

COVER-INVERTER

000034393 / 317773-01-CHT POWER CORD BOX ASM

000037281 / 318494-01-000 CLAMP

10497-03-000 SCREW

G39-10-12U

6

5 WIRE IS PART OF WIRE ASM-CHASSIS.

SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

7

8 PLUG TRANSFER SWITCH INTO 110V OUTLET IN INVERTER FRONT.

9 CONNECT INVERTER INPUT TO BRN WIRE INVERTER OUTPUT TO BRN-2 WIRE.

CONNECT ORG CABLE TO RED(+) TERMINAL, BLK CABLE TO WHITE(-) TERMINAL, GROUND TO GROUND LUG.

5 8

(2)

X-X

FOR ELECTRICAL

CALLOUTS SEE DWG NO.

121339-01-000 FOR ELECTRICAL

TORQUE

SPECIFICATIONS SEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

265 1B1

1B1 265

C

A

DESCRIPTION:

B

A

D D

B C

WIRING INSTL-BODY,110V

BRACKET-110V CONNECTOR,MOUNT 155223-08-CHT SCREW

G67-10-08U (2)

SLIDEOUT WIRE #1 (REF)

BRACKET-110V CONNECTOR,MOUNT 155223-08-CHT SCREW

G67-10-08U (2) CLAMP

10495-01-000 (4) SCREW

G67-10-12U (4)

WIRE IN SIDEWALL.

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

5

TO RIGHT SIDE DETAIL

BA

110V CONNECTIONS DETAIL

BA

1.

5

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000 WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12U.

3.

RCP-B (BRN-2) SLIDEOUT

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

4

RCP-B (BRN-2) SLIDEOUT

SLIDEOUT WIRE #1

110V CONNECTIONS DETAIL

BA

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

2.

WIRE ASM-110V (BRN-2)

RECEPTACLE (BED,FRONT) 000025877/315435-01-CHT BOX

133070-01-000 SCREW

G13-07-12U (4) CONNECTOR

8313-01-000 TUBING-VINYL

8041-02-000 (300MM) WIRE-BONDING

133678-01-000 6 APPLY TO BARE GROUND WIRES.

6

6 RECEPTACLE (BED,REAR) 000025877/315435-01-CHT BOX

133070-01-000 SCREW

G13-07-12U (4) CONNECTOR

8313-01-000 TUBING-VINYL

8041-02-000 (300MM) WIRE-BONDING

133678-01-000 4

THROW IN WIRE #2 THROW IN WIRE #1

RCP-2 (BRN-2) DINETTE

4 THROW IN WIRE #1

(REF)

(3)

X-X

FOR ELECTRICAL

CALLOUTS SEE DWG NO.

121339-01-000 FOR ELECTRICAL

TORQUE

SPECIFICATIONS SEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

265 1B1

1B1 265

000033161 / 31758901000 3

OF

5

SHEET:

C

A

DESCRIPTION:

B

REV

A

ITEM/PART NO:

D D

B C

WIRING INSTL-BODY,110V

(BRN-2) 3400 DROP TO LEFT SIDE.

2

RCP-2 (BLU) GALLEY

LOAD CENTER GROUND WIRES MUST BE ATTACHED DIRECTLY TO CHASSIS GROUND.

3

NOTES:

RCP-1 (BLK-2) MICROWAVE

CLAMP

10495-01-000 SCREW

G67-10-12U

WIRE ROUTED IN ROOF.

2 6.

TO LEFT SIDE 5.

7

3

CLAMP

10495-01-000 SCREW

G67-10-12U

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

7

1

1

LOAD CENTER GROUND CABLE TO CHASSIS GROUND BAR

WIRE ROUTED THROUGH FLOOR IN THIS AREA.

1

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000 WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12U.

LOAD CENTER ASM

000037284 / 318497-01-000

RCP-B (RED) REFRIG CABT

4

BRN AND BRN-2 ROUTE THROUGH THE FLOOR IN THIS AREA TO CONNECT TO INVERTER.

4

RECEPTACLE ASM-GFI,US-15A 000120175 / 322736-01-XXX RECEPTACLE ASM-GFI,CAN-15A 000120176 / 322737-01-XXX (BLU) (BATH)

265 1B1

(4)

X-X

FOR ELECTRICAL

CALLOUTS SEE DWG NO.

121339-01-000 FOR ELECTRICAL

TORQUE

SPECIFICATIONS SEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

265 1B1

1B1 265

C

A

DESCRIPTION:

B

A

D D

B C

WIRING INSTL-BODY,110V

ALL GROUND WIRES TO BE COVERED WITH TUBING 8041-02-000.

1.

FOR CONNECTOR INSTALLATION SEE DETAIL DD.

2

3 FOR CONNECTOR INSTALLATION SEE DETAIL DC.

1B1

265

1B1

265

1B1

265

1B1

265 265 1B1 265 1B1

4

33F

33F 3 3 RED

136135-07-032

136136-07-032

BLK

136131-06-044

136134-06-044

BRN

136131-03-040

136134-03-040

BRN-2

136131-19-164

136134-19-164

BLU

136131-02-165

136134-02-165

MAIN

136137-01-055

136138-01-055

SLIDEOUT WIRE #1 136151-19-040

GENERATOR CABLE ASM

164957-02-044

164957-04-044

GROUND 136145-02-036

THROW IN WIRE #1

136131-19-006

136134-19-006

THROW IN WIRE #2

136131-19-052

136134-19-052

GEN-3.2 KW ONAN DIESEL 33F

2 2

1B1

265

BRN-2

CONNECTOR-WIRE,NM, CLEAR 144283-02-000

THROW IN WIRE CONNECTOR-WIRE,NM, CLEAR 144283-02-000 (2)

DETAIL

DD

DETAIL

DC

CONNECTOR-WIRE,SOW, BLUE 144283-01-000 (2)

SLIDEOUT WIRE

DETAIL

DE

FOR CONNECTOR INSTALLATION SEE DETAIL DE.

4

265 1B1

2 2

265 1B1

APPLY CONDUIT-CONVOLUTE 41953-05-000 OVER WIRE AND

SECURE BOTH ENDS OF TUBING TO WIRE WITH TAPE 8363-01-000.

5

5

(5)

X-X

FOR ELECTRICAL

CALLOUTS SEE DWG NO.

121339-01-000 FOR ELECTRICAL

TORQUE

SPECIFICATIONS SEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

265 1B1

1B1 265

5

OF

5

WIRING INSTL-BODY,110V 000033161 / 31758901000

SHEET:

C

A

DESCRIPTION:

B

REV

A

ITEM/PART NO:

D D

B C

6

3

BRN-2 4

SLIDEOUT WIRE #1 5

2

RCP-2 DINETTE

6

10-2

110V CONNECTOR (LOCATED BELOW

MURPHY BED) RCP-

CONVERTER 14-2

10-2

RCP-2 EXT COMPT

JUNCTION BOX

2

110V CONNECTOR (LOCATED UNDER

SHOWER PAN) GENERATOR

110V CONNECTOR (LOCATED BELOW

FLOOR) 14-2

WIRE ROUTED IN ROOF.

RCP- GALLEY TV

TRANSFER SWITCH POWER

CORD ASM

8-GRN

15 20

ALL WIRES DOWN STREAM AND INCLUDING THIS OUTLET ARE GROUND FAULT CIRCUIT INTERRUPT PROTECTED.

3

ROOF AIR

CONDITIONER 6 POWER CORD

RECP BOX

RCP-GFI BATH

RCP- MICROWAVE

1

4

NOTES:

WIRE ROUTED IN SIDEWALL.

SEE MANUFACTURERS DIAGRAM.

5

GROUND LUG

RCP-2 GALLEY

15

WIRE ROUTED THRU FLOOR.

110V CONNECTOR (LOCATED BELOW

FLOOR) RCP-BLANK

REFRIG CABT 14-2

LOAD CENTER

30

10-2

1

WIRE AND RECEPTACLE SUPPLIED INTREGRATED INTO LOAD CENTER DISTRIBUTION PANEL.

15 15

12-2

RCP-BLANK SLIDEOUT

THROW IN WIRE #1

RCP-BED,FRONT

RCP-BED,REAR THROW IN WIRE #2

References

Related documents

For many of our clients, their main residence, a second home or a buy-to-let investment constitutes a major component of their assets.. Real estate is a way of diversifying

Total sample 1 Investment in information High trust in advisor Medium trust in advisor Financial wealth Low risk aversion Moderate risk aversion Medium risk aversion Years of

Considering Bruxelles, Hamburg and Île-de-France as references, we evaluated that about 30 % of European regions will converge to the level of development achieved by these three best

In general organizations should work to strengthen coping resources by developing workplace programs that build upon strategies that hospice nurses consider most effective (i.e.

Third, the Bureau has not incorporated from the “remittance transfer provider” definition the requirement that transfers be provided “in the normal course of business.” 60 The

• It’s all about achieving our goals, budget and vision • MMMM shares corporate profit with Regional Teams,. Divisional Teams and the Executive Leadership Team  Bonuses are

• Epidural tray or spinal tray should contain sterile gauze, sterile cleaning solution (such as povidone iodine, three cleaning sponges, sterile saline [0.9% NaCl], glass

Design & Layout Copywriting Print Production Photographic Services Website Programming. Search Engine Registration/Optimization