• No results found

DCP to CBR 01

N/A
N/A
Protected

Academic year: 2021

Share "DCP to CBR 01"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

1. INTRODUCTION

Dynamic Cone Penetrometer (DCP) is an instrument, which can be used to evaluate California Bearing Ratio (CBR) value and Elastic Modulus (E) of soils. It is an insitu test, simple to use and inexpensive. Scala [1], originally developed the DCP in Australia. After that various researchers developed both the testing instrument and the testing procedure. The relationships were developed between DCP and CBR, shear strength, soil index properties etc. [2]. There are various types of DCPs available in the world. They are operated on the same principle. A DCP consists of an 8 kg weight dropping through a height of 575 mm and a 600cone having a base diameter of 20 mm as shown in Figure 1. The penetration of the cone is measured using a calibrated scale. It is possible to measure up to 800 mm depth without an extension rod and up to 1200 mm depth when fitted with an extension rod. It needs three operators, one to hold the instrument, one to raise and drop the weight and the other to record the penetration.

2. EXISTING CORRELATION BETWEEN DCP AND CBR

To assess the structural properties of the pavement subgrade, the DCP values are usually correlated

with the CBR value [3-4]. Different correlations were suggested between the DCP-PR in (mm/blow) and CBR values. Kelyn [3] conducted DCP tests on 2,000 samples of pavement materials in standard moulds directly following CBR determination. Based on his results the following correlation was recommended:

Log CBR = 2.62 – 1.27 log PR (1)

Based on a field study, Smith and Pratt [5] suggested the following correlation:

Log CBR = 2.56 – 1.15 log PR (2)

Fig. 1.Dynamic Cone Penetrometer (DCP) [6]

THE USE OF DYNAMIC CONE PENETROMETER (DCP) TO DETERMINE SOME

USEFUL RELATIONSHIPS FOR SANDY AND CLAYEY SOILS

Mohammadi, S.D. and Nikoudel, M.R. Tarbiat Modares University, Tehran, Iran Khamehchiyan, M.

Tarbiat Modares University, Tehran, Iran

ABSTRACT: This paper explains a laboratory investigation carried out to develop some useful relationships for the use of

Dynamic Cone Penetrometer (DCP) for road subgrade evaluation and building foundation. Series of laboratory tests were performed by varying the moisture content and the dry density. Bad graded sands (SP) and Clayey Silt (CL-ML) were used for the study. Experimental procedure, statistical analysis of the results and the developed equations are presented in this paper.

Keywords: Dynamic Cone Penetrometer (DCP), California Bearing Ratio (CBR) test, Plate Load Test (PLT), Moisture content, Dry density

(2)

Livneh and Ishia [7] conducted a correlation between the DCP-PR and the in-situ CBR values using a wide range of undisturbed and compacted fine-grained soil samples, with and without saturation. Compacted granular soils were tested in flexible moulds with variable controlled lateral pressures.

The equation 3 was obtained between CBR and DCP-PR:

Log CBR = 2.2 – 0.71 (log PR) 1.5 (3) Harrison also suggested equations 4 and 5 for different soils [8]:

Log CBR = 2.56 – 1.16 log PR for clayey-like soil

of PR > 10 (mm/blow) (4)

Log CBR = 2.70 – 1.12 log PR for granular soil of

PR<10 (mm/blow) (5)

For a wide range of granular and cohesive materials, the U.S. Army Corps of Engineers found the relation described in equation 11 [9]; this equation was also adopted by many researchers [7, 10-11].

Log CBR = 2.465 – 1.12 (log PR) or

CBR = 292/PR1.12 (6)

Minnesota Department of Transportation (MnDOT) also adopted equation 6. They found that the effects of soil moisture content and dry density influence both CBR and DCP values in a similar way; therefore, they are considered negligible for the correlation [12].

In CBR tests, standard moulds of 6-in. diameter and 7-in. height were used for preparation. Because of the difficulty in making the exact density level, at least four samples with different compaction levels were prepared with the same required moisture content. Specimens were compacted at five layers. An automatic compactor with a 5-lb. hammer was used. The typical numbers of blows per layer were 10, 25, 56, and 75. After the dry density was obtained for each CBR sample, unsoaked CBR values were obtained for each compaction level and plotted versus the moulded dry density values. The CBR value corresponding to the specific dry density of the represented material was then obtained by interpolation.

3. EXISTING CORRELATION BETWEEN DCP AND PLT

Based on a regression analysis, Konard and Lachance [13] suggested a relationship between the

PR of a large DCP with a 51 mm diameter cone and

the elastic modulus of unbound aggregates and natural granular soils back-calculated from plate load tests (EPLT), and it is as equation 7:

Log (EPLT) = (-0.88405) Log (PR) +2.90625 (7) Where EPLT is expressed in MPa.

As in the case for other stress-strain tests, different elasticity moduli can be obtained from the PLT. Soil elasticity moduli can be defined as: (1) the initial tangent modulus; (2) the tangent modulus at a given stress level; (3) reloading and unloading modulus and; (4) the secant modulus at a given stress level. In this study, the initial tangent modulus was determined for all plate load tests. To determine the initial modulus (EPLT(i)), a line was drawn tangent to the initial segment of the stress-strain curve; then an arbitrary point was chosen on this line and the stress and deflection corresponding to this point was used to determine the initial modulus. Figure 2 describes the deflection and stress used for determining EPLT(i) from δ 1 and p. German Code for the design of flexible pavement structures specifies performing in-situ plate-bearing tests on constructed pavement layers [13]. For the second cycle of the regular plate-bearing test, the German code defines a reloading stiffness modulus called EPLT(R2) using the following equation [14]:

ER2 = 2P(1-ν2)/πRδ (8)

Where p=applied load by the end of the second cycle, and δ = deflection under the second loading cycle of the plate. In this study, the reloading elastic modulus (EPLT(R2)) defined by the German code was also used.

Round plates with 8 in. diameters were used for the project. The PLT was used as a reference test to obtain the strength characteristics of the layers. One test for each test case was conducted. A loading frame that was designed to fit to the mould was used as a support for the test.

A bearing plate and hydraulic jack were carefully placed at the center of the samples under the loading frame (figure 3).

(3)

Fig.2. Definition of modulus from PLT [11]

The hydraulic jack has a resolution of 1.5 tons. Dial gauges that are capable of recording a maximum deformation of 1 in. with a resolution of 0.001 in. were used in the PLT. The ASTM-D1196 [11] standard method was followed to perform the test [7]. Plate diameter, applied load increments and the corresponding deflections were recorded for each load increment. Each sample was loaded up to failure or until the load capacity of the loading frame had been reached. Each sample was unloaded and reloaded at least once to be able to determine the reloading modulus of the samples in addition to the initial loading modulus.

4. TESTING PROGRAM AND SAMPLE PREPARATION

The testing program included only laboratory tests on compacted soils. The DCP test was carried out in a mould with a diameter of 700 mm (figure 4). Materials used in this research included typical Tehran alluvial soils (Sandy and Clayey silt soils) have taken from West of Tehran. Testing program and the optimum moisture content, maximum dry density and classifications for these materials are presented in tables 1and 2.

Fig. 3. A schematic diagram of Plate Load Test (PLT) set up

Fig .4. A schematic diagram of DCP test in testing mould

Compacted Sample Surchare Load 700 mm 700 m m DCP Base Plate Surchare Load Base Beam DCP

(4)

Table 1.Testing Program for laboratory investigation

Table 2. Physical properties of sample soils

5. DCP CORRELATIONS 5.1. DCP versus CBR

As mentioned earlier, the DCP penetration rate can be converted to an equivalent CBR value for use as a measure of stability and strength. The use of DCP tests to predict the CBR is preferred because it is simple and inexpensive and it enables rapid measurements of the in-situ strength of pavement layers and subgrades. Several correlations developed between the DCP penetration rates and CBR values are available in literature. One of the objectives of this research was to enhance the level of confidence of the DCP’s usage for CBR determination. The average DCP penetration rates of the top 12 in. depth were used to investigate the possible correlation between the DCP penetration rate and CBR value. As shown in figure 5, the best fit between the DCP penetration rate and CBR value is a log-log correlation, which is similar to the ones available in the literature:

Log CBR = 2.256 - 0.954 log PR (R2= 0.56) (9)

5.2. DCP versus PLT

Several correlations between the average DCP penetration rate versus the PLT initial and reloading

Fig.5. Correlation between DCP-PR and CBR

moduli (EPLT(i), EPLT(R2)) were investigated. The DCP has already proven to be an effective tool for in-situ strength evaluation. A strong correlation between the DCP and the PLT will enhance the credibility of both devices. The average DCP penetration rates for the top 12 in. depth were used to investigate a possible relation between the DCP penetration rates and the moduli obtained from PLT, (EPLT(i), EPLT(R2)). The best correlation between the average DCP penetration rates and EPLT(i) is presented in figure 6

(equation 10). Figure 7 shows that there is a better correlation (equation 11) between the average DCP penetration rates and the PLT reloading modulus (EPLT(R2)) compared to the correlation with EPLT(i). EPLT(i) = 6925/(6.1+ PR1.4) (R2= 0.65) (10) EPLT(R2) =2550*PR-1.290 (R2= 0.79) (11) These correlations show that the correlations suggested in this study are very close to those suggested by Konard and Lachance [13].

Fig.6. Correlation between DCP-PR and EPLT(i)

SAMPLE ID content Water (%) Dry Density (t/m3) DCP PLT CBR Sandy soil-1 2.0 1.807 2 1 4 Sandy soil-2 2.5 1.660 2 1 4 Sandy soil-3 2.2 1.648 2 1 4 Clayey silt-1(opt) 19.0 1.749 2 1 4 Clayey silt-2(dry) 15.4 1.644 2 1 4 Clayey silt-3(wet) 20.1 1.626 2 1 4

SAMPLE ID Sandy soil Clayey silt Maximum dry unit

weight (KN/m3) 17.85 16.28

Minimum dry unit

weight (KN/m3) 13.24 - Specific gravity 2.66 2.70 Liquid limit (%) - 27 Plasticity Index - 15 Sand (%) 98 9 Silt (%) 2 72 Clay (%) 0 19

Soil class (USCS) SP CL-ML

0 5 10 15 20 25 0 10 20 30 40 50 60 70 80 DCP-PR(mm/blow) CBR(%) formula 9 Sandy soil Clayey Silt 0 20 40 60 80 100 120 140 160 180 200 0 10 20 30 40 50 60 70 80 DCP-PR(mm/blow) E P LT(i )(MP a ) Sandy Soil Caleyey silt fomula 10

(5)

Fig.7 Correlation between DCP-PR and EPLT(R2)

6. COCLUSION

This study showed that the DCP had the most consistent results within the different layers. Several good correlations were developed between the DCP - PR with the CBR and PLT. The proposed DCP-PLT relations were compatible with the relation suggested by Konard and Lachance [13]. The results of this study showed that the DCP had better correlation with CBR than the other two devices, which then can be used to estimate the resilient modulus of the tested material.

Therefore, the DCP penetration can be used to profile the in-situ CBR values and/or the modulus for the different pavement layers and subgrades to the depth of penetration. Alternatively, the stiffness of materials can be represented by DCP penetration rates directly.

The results of this study indicated that the DCP can reliably predict the moduli obtained from PLT and CBR values, and thus can be used to evaluate the in-situ stiffness characteristics of compacted soils, subgrade, base layers, and embankments for design purposes.

7. REFERENCES

1.Scala, A.J. (1959) Simple Method of Flexible Pavement Design Using Cone Penetrometers, In Proceedings of 2ndAustralian – New Zealand Conference on Soil Mechanics

and Foundation Engineering, New Zealand, Jan. 1959. 2.Karunaprema, K.A., Edirisinghe, A.G.(2002) A Laboratory Study to Establish Some Useful Relationships for the Use of Dynamic Cone Penetrometer, EJGE, 0228: 1-16.

3. Kleyn, E. G. (1975) The Use of the Dynamic Cone Penetrometer (DCP), Report 2/74. Transvaal Roads Department, Pretoria.

4. Livneh, M. (1989) Validation of Correlations between a Number of Penetration Tests and In Situ California Bearing Ratio Tests,” TRRL 1219.

5. Smith, R. B., and Pratt, D. N. “A Field Study of In Situ California Bearing Ratio and Dynamic Cone Penetrometer Testing for Road Subgrade Investigation.” Australian Road Research, Vol. 13, No. 4, 1983, pp. 285-293.

6. Nazzal D.M. (2003) Field evaluation of in-situ test technology for Qc/Qa during construction of pavement layers and embankments, M.Sc. thesis, Birzeit University, Birzeit, West Bank,

7. Livneh, M., and I. Ishai.(1987) “Pavement and Material Evaluation by a Dynamic Cone Penetrometer.” Proc., Sixth International Conference on the Structural Design of Asphalt Pavement, Vol. 1, Ann Arbor, Michigan , pp. 665-674.

8.Harrison, J.A. (1986) “ Correlation of CBR and Dynamic Cone Penetrometer Strength measurement of Soils. ” Australian Road reaearch, vol 16, No.2, pp. 130-136.

9. Webster, S.L.; Grau, R.H.; and Williams, R.P. (1992) Description and application of Dual Mass Dynamic Cone Penetrometer, U.S. Army Engineer Waterways Experiment Station, Instruction Report, No. GL-92-3.

10. Chen, D. H., Wang, J. N., Bilyeu, J. (2001) Application of the DCP in evaluation of base and subgrade layers, In 80th Annual Meeting of Transportation Research Board, Washington, D.C, January 2001.

11. American Society of Testing and Materials (1998) “Standard Test Method for Repetitive Static Plate Load Tests of soils and Flexible Pavement Components, for Use in Evaluation and Design of Airport and Highway Pavements. ” Annual Book of ASTM Standards, vol.04.08, pp. 110-113. 12. Abu-Farsakh, Y.M., Khalid Alshibli, P.E., Nazzal, D.M., and Seyman E. (2003 ) Assessment of in-situ test technology for construction control of base courses and embankments, Louisiana Transportation Research Center 4101 Gourrier Avenue Baton Rouge, LA 70808.

13. Konard, J.M., and Lachance, D., (2000) “ Mechanical Properties of Unbound Aggregates from DCP and Plate Load Tests. ” Proceeding of the Fifth International Conference on Unbound Aggregate in Roads, Nottiingham, United Kingdom. 14. Siekmeier, J.A.; Young, D.; and Beberg, D. (2000) Comparison of the Dynamic Cone Penetrometer with other tests during subgrade and granular base characterization in Minnesota.” Nondestructive Testing of Pavements and Backcalculation of Moduli: Third Volume, ASTM STP 1375, p175-188. S.D. Tayabji and E.O. Lukanen, Eds., American Society for Testing and Materials.

0 20 40 60 80 100 120 140 0 10 20 30 40 50 60 70 80 DCP-PR(mm/blow) E P LT(R2 )(MP a ) formula 11 Sandy soil clayey silt

References

Related documents

Assessment of sustainability index using Rap- Tobacco based on ecological, social economy, institutional and policy, and technological aspects for tobacco planted in

С приемането на Закона за регистрация и контрол на земеделската и горска техника /ЗРКГТ/, (ДВ, бр.79 от 1998 г.) и поднормативните актове започна процесът на привеждане на

Behaviour of elliptical concrete-filled steel tube (CFT) columns under axial compression load..

Local Data Store Operator or ROSATTE Data Store Operator, Enacting authority or Field surveyor or Provider Road network Incremental update of safety attributes and network

The resistive element is realized by inserting several strip-type parallel LC structures into a resistor-loaded square-loop element, which allows the surface current to be controlled

Global dynamics of a delayed chemostat model with harvest by impulsive flocculant input Zhang et al Advances in Difference Equations (2017) 2017 115 DOI 10 1186/s13662 017 1163 9 R E S E

In general, we provide some evidence that FDI inflows play an important role during the development process: Initially, as an important determinant of growth, later on, by

A futures contract is a transferable agreement to make [short] or take [long] delivery of a standardized amount and designated quality, at a specified price, at a specified date