O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

N/A
N/A
Protected

Academic year: 2021

Share "O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

P re li m in ar y

■ M o d e l E n c o d i n g

■ D e s c r i p t i o n

O W A - 1 2 0 U i s o n e 1 2 0 W s i n g l e - o u t p u t e x t e r n a l L E D p o w e r s u p p l y s e r i e s . P a i r i n g t h e N o r t h A m e r i c a n t y p e o f A C p l u g a n d t h e p r e v a i l i n g D C c o n n e c t o r s , O W A - 1 2 0 U , w o r k i n g l i k e a n a d a p t o r , s i m p l i f i e s t h e c o n n e c t i o n w i t h L E D l i g h t i n g f i x t u r e s w i t h o u t e x t r a w i r i n g e f f o r t s . T h e e n t i r e s e r i e s i s c e r t i f i e d w i t h t h e U L l i s t i n g f o r d r y a n d d a m p l o c a t i o n s .

A s a c l a s s ( Ⅱ w i t h o u t e a r t h p i n ) d e s i g n , t h e e n c l o s u r e o f O W A - 1 2 0 U i s a 9 4 V - 0 f l a m e r e t a r d a n t p l a s t i c c a s e . T h e i n t e r i o r i s f u l l y p o t t e d w i t h s i l i c o n e t h a t e n h a n c e s t h e h e a t d i s s i p a t i o n . W i t h t h e w o r k i n g e f f i c i e n c y u p t o 9 1 % , O W A - 1 2 0 U i s c o o l e d b y f r e e a i r c o n v e c t i o n ; t h e w o r k i n g t e m p e r a t u r e r a n g e s f r o m - 4 0 ℃ t o + 7 0 ℃.

‧ U n i v e r s a l A C i n p u t / F u l l r a n g e

‧ B u i l t - i n a c t i v e P F C f u n c t i o n

‧ P r o t e c t i o n s : S h o r t c i r c u i t / O v e r c u r r e n t / O v e r v o l t a g e / O v e r t e m p e r a t u r e

‧ F a n l e s s d e s i g n , c o o l i n g b y f r e e a i r c o n v e c t i o n

‧ C o o l i n g b y f r e e a i r c o n v e c t i o n

‧ N o l o a d p o w e r c o n s u m p t i o n < 0 . 1 5 W

‧ N R C a n

‧ M e e t

‧ 5 y e a r s w a r r a n t y

H i g h e f f i c i e n c y u p t o 9 1 %

c o m p l i a n t

E I S A 2 0 0 7 ( E n e r g y I n d e p e n d e n c e a n d S e c u r i t y A c t ) U L L I S T E D , s u i t a b l e f o r d r y , d a m p , w e t l o c a t i o n s

‧ L E D l i g h t i n g f i x t u r e

‧ G e n e r a l e l e c t r o n i c p r o d u c t s i n d u s t y o r h u m i d e n v i r o n m e n t

■ F e a t u r e s ■ A p p l i c a t i o n s

120W Single Output Switching Power Supply O WA - 1 2 0 U s e r i e s

O u t p u t v o l t a g e

N o r t h A m e r i c a n t y p e o f A C p l u g O u t p u t w a t t a g e

S e r i e s n a m e

IP67

- U 1 2 O W A - 1 2 0

File Name:OWA-120U-SPEC 2014-05-16

(2)

P re li m in ar y

SPECIFICATION

File Name:OWA-120U-SPEC 2014-05-16

MODEL

DC VOLTAGE

RATED CURRENT RATED POWER

OUTPUT

LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.4 HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.)

EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT

INRUSH CURRENT (Typ.) LEAKAGE CURRENT

WORKING TEMP.

WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

MTBF DIMENSION OTHERS

NOTE

PACKING

OVER CURRENT

OVER VOLTAGE

OVER TEMPERATURE

500ms, 80ms at 95% load 230VAC / 115VAC 16ms at full load 230VAC / 115VAC 90 ~ 264VAC 127 ~ 370VDC 47 ~ 63Hz

PF>0.97/115VAC, PF>0.96/230VAC at full load

1.3A / 115VAC 0.65A / 230VAC

<0.25mA / 240VAC 95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

-40 ~ +70℃ (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH

±0.03%/℃ (0 ~ 50℃)

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

K hrs min. MIL-HDBK-217F (25℃) 191*63*37.5mm

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. Kg

RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3

ENVIRONMENT PROTECTION

Shut down o/p voltage, re-power on to recover

SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed

Protection type : Shut down o/p voltage, re-power on to recover COLD START 60A(twidth= s measured at 50% Ipeak) at 230VAC

15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V

89% 89% 89% 90% 90% 90% 90% 91% 91%

±4.0% ±4.0% ±4.0% ±4.0% ±3.0% ±2.0% ±1.0% ±1.0% ±1.0%

±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%

±2.0% ±1.5% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%

12V 15V 20V 24V 30V 36V 42V 48V 54V

OWA-120U-12 OWA-120U-15 OWA-120U-20 OWA-120U-24 OWA-120U-30 OWA-120U-36 OWA-120U-42 OWA-120U-48 OWA-120U-54

150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p

10A 8A 6A 5A 4A 3.4A 2.9A 2.5A 2.3A

120W 120W 120W 120W 120W 122.4W 121.8W 120W 124.2W

SAFETY &

EMC

WITHSTAND VOLTAGE ISOLATION RESISTANCE SAFETY STANDARDS

Compliance to FCC Part15 EMC EMISSION

UL8750 listed, CSA C22.2 No. 250.13-12, IP67 approved TOTAL HARMONIC DISTORTION THD< 20% when output loading≧60% at 115VAC/230VAC

μ

I/P-O/P:3.75KVAC

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

CONSTANT CURRENT REGION 7.2 ~ 12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V

(3)

P re li m in ar y

0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

230VAC

115VAC

PFC fosc : 50~120KHz PWM fosc : 60~130KHz

INPUT VOLTAGE (V) 60Hz

90 100 125 135 145 155 165 175 180 200 230 264 100

90 80 70 60 50

LOAD (%) 40

PF

LOAD (120W)

Power Factor Characteristic

230VAC Input only

20 40 60 80 100

(HORIZONTAL)

-25 00 15 30 40 50

-40 60 70

50

120W Single Output Switching Power Supply O WA - 1 2 0 U s e r i e s

File Name:OWA-120U-SPEC 2014-05-16

Derating Curve Static Characteristics

DETECTION

PWM & PFC CIRCUIT

O.L.P.

O.T.P.

EMI FILTER RECTIFIERS

POWER SWITCHING

FILTER

&

RECTIFIERS +V

I/P -V

CONTROL

O.V.P.

&

O.L.P.

PFC CIRCUIT

Block Diagram

LOAD (%)LOAD (%)

AMBIENT TEMPERATURE (℃)

LOAD (%)

(4)

P re li m in ar y

78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

230VAC

115VAC

LOAD

EFFICIENCY (%)

OWA-120U series possess superior working efficiency that up to 91% can be reached in field applications.

DRIVING METHODS OF LED MODULE

There are two major kinds of LED drive method, "direct drive" and "with LED driver".

A typical LED power supply may either work in "constant voltage mode (CV)" or "constant current mode (CC)" to drive the LEDs.

Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).

Typical LED power supply I-V curve

Vo(%)

100

60

50 100

(min.)

Io (%) Constant Current area

Hiccup Protection Constant

Voltage area

(A) (B)

(C)

In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.

Should there be any compatibility issues, please contact MEAN WELL.

File Name:OWA-120U-SPEC 2014-05-16

(5)

P re li m in ar y

Mechanical Specification

Mechanical Specification

Unit:mm

※ T case: Max. Case Temperature.

UL2464 18AWG×4C

37.5

1500±20

300±20

SVT 18AWG×2C 63

2-ψ4.5

191

5

5

5

5

85.5

31.5

Plug Assignment

PIN NO.

1,4 2,3

All models : power DIN 4 pins with lock type, Zhuotenkeji ZT-POWER03M080, or KYCON KPPX-4P, or equivalent

OUTPUT +V -V

2 3

1 4

1 2 4 3

Installation Manual

Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html

Recommend Mounting Direction

120W Single Output Switching Power Supply O WA - 1 2 0 U s e r i e s

File Name:OWA-120U-SPEC 2014-05-16

References

Related documents

Trap Humidity Threshold Select the Trap Humidity Threshold check box to enable a trap to be sent to the Trap IP Address each time the measured humidity for an enabled humidity

If each transmitter uses a separate power to deal with the common ground for each transmitter.Supply voltage temperature and humidity transmitter according to the connected load

consists of a number of components including the gears from the Kawasaki Bayou, a cast and machined case, a sequential shift assembly, a final externally-splined output shaft

Aiming the availability of a comprehensive overview of the existing technologies to system designers and end-users, the database has been fed through an online form,

Honeywell HumidIcon™ Digital Humidity/Temperature Sensors, HIH8000 Series, are digital output-type relative humidity (RH) and temperature sensors combined in the same package..

Features: Humidity and temperature sensing in one package • Near linear voltage output vs %RH • Laser-trimmed • Accurate, fast response • Designed to be chemically resistant

RST-10000 has the built-in active current sharing function and can be connected in parallel, up to 2 units, to provide higher output power as exhibited below : ※ The voltage

1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can