• No results found

Declaration of Conformity In Accordance with ANSI/ISEA

N/A
N/A
Protected

Academic year: 2021

Share "Declaration of Conformity In Accordance with ANSI/ISEA"

Copied!
6
0
0

Loading.... (view fulltext now)

Full text

(1)

X

Name

Title

Date

DoC Rev1 7.2.14

Declaration of Conformity

In Accordance with ANSI/ISEA 125-2014

Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221

Declaration #

C0316025

Declaration Date

3.22.16

Tested Item #

8240

4½ to 6' ElasTech® Shock Absorbing Lanyard

Additional Items Conforming Under this Declaration:

8240L 82403 82403L 8240A 82403A A8240

Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with

the requirements of the following performance standard(s):

ANSI Z359.13-2013

Conformity Assessment Method in accordance with ANSI/ISEA 125-2014

Level 1 Level 2 Level 3

Level 1: FallTech Lab Outside the Scope of ISO/IEC Standard 17025:2005

Level 2: FallTech Lab Within the Scope of ISO/IEC Standard 17025:2005

Level 3: Independent 3rd Party Lab accredited to

ISO/IEC Standard 17025:2005 Supporting

Documentation

PC-0843

Authorized Signature

(2)

March 28, 2016

FallTech Testing Laboratory

1306 S. Alameda Street

Compton, CA 90221

Attention:

Jay Sponholz

Quality Manager

Subject:

Attestation of Witnessing Testing

Exova OCM Job # 360367-5

FallTech P.O.:

OPEN

Report No.:

PC-0843

Base Part No.

8240

Description:

Energy Absorbing Lanyard

Dear Mr. Sponholz:

The purpose of this attestation is to attest to the fact that a representative of Exova OCM was on site at

FallTech’s facilities to confirm suitability of the equipment used, calibration status of the equipment and to

witness testing performed by FallTech employees. Details of this visit are included below:

Date of Testing:

10 & 16 March 2016

Exova OCM Test Witness:

Robert Fortner

FallTech Test Operators:

Yesbet Sierra and Jay Sponholz

Specification:

ANSI Z359.13-2013 Sections 4.5, 4.6, 4.13.1, 4.13.2, 4.13.3

Equipment Calibration Interval

1 year, except weights which are 5 years

Page 1 of 2

This attestation is issued in accordance with our terms and conditions, a copy of which is available on request. Exova OCM 3883 East Eagle Drive Anaheim, CA 92807 USA

(3)

Exova

OCM

Attached to this attestation is the test report generated by FallTech Testing Laboratory. Exova

OCM

test witness certifies the report accurately presents the testing performed on the samples identified.

Test Report # Date

PC-0843 3/22/2016

Test Witness Signature:

Robert Fortner Technician

Mechanical Laboratory

Approval Signature:

Bruce K. Sauer Technical Director

Approval Signature:

Thomas J. (Tom) Parsons Manager

Quality I Technical Services

Base Part# Description Sample !D's Results

3141403 3141406 3141405 3141403 3141406 3141405 3141411

8240 Energy Absorbing Lanyard 3141402 Pass

3141404 3141410 3141408 3141407 3141416 3141414 3141409

(Signed for and on behalf of Exova-OCM)

(Signed for and on behalf of Exova-OCM)

OS?~

This attestation shall not be reproduced except in full, without the written approval of Exova-OCM. The laboratory has witnessed the testing the material I items supplied by the client as sampled by the client. The testing is not within Exova OCM's L.A.B scope of testing and was not performed at Exova OCM.

~

- - ,,~·1"'''''1,,

rt

-

LABORATORY

AClij

,~~\

~

ACCREDITATION

. ECOQNIZID

~

BUREAU

adi

visiono

f

~

''/,,/JS:~'~,, ®

ACCREDITED

/SOI/EC 17025

Certificate# L2195 Testing

FallTech Testing Laboratory Attestation Number: 360367-5

Revision Letter: Original

Page 2 of 2

(4)

FallTech Testing Laboratory

1306 S. Alameda Street, Compton, CA 90221-4803

Tel: (323) 752-0060 www.falltech.com

PC-0843 Date 3/22/2016 Rev Rev Date

Report Prepared For

Dan Redden

8240

N/A BOM No

PC-0843 3/9/2016 3/16/2016

Jay Sponholz

Energy Absorbing Lanyard

Test Report Number

3141403 Energy Absorbing Lanyard

FallTech Test Report

Test Specification

Date Received Date Complete Description

ANSI Z359.13-2013

4.5, 4.6, 4.13.1, 4.13.2, 4.13.3 Energy Absorbing Lanyard Production

Proposed Part #

FallTech

Built By Whom Test Request #

Initiated By

Base Part #

Energy Absorbing Lanyard

3141406 Energy Absorbing Lanyard

3141406 Energy Absorbing Lanyard

3141405 Energy Absorbing Lanyard

3141411

3141416 Energy Absorbing Lanyard

3141414 Energy Absorbing Lanyard

3141409

Test Operator Test Operator Yesbet Sierra

Material/Sample Identification

3141405

Sample ID Description

3141403

Energy Absorbing Lanyard

3141402 Energy Absorbing Lanyard

3141404 Energy Absorbing Lanyard

3141410 Energy Absorbing Lanyard

3141408 Energy Absorbing Lanyard

3141407 Energy Absorbing Lanyard

Energy Absorbing Lanyard

Certificate# TL-594 Testing

FLT-08 Rev. G Page 1 of 8

(5)

FallTech Testing Laboratory

1306 S. Alameda Street, Compton, CA 90221-4803

Tel: (323) 752-0060 www.falltech.com

PC-0843 Date 3/22/2016 Rev Rev Date

Report Prepared For

Dan Redden

8240

N/A BOM No

PC-0843 3/9/2016 3/16/2016

Test Report Number

FallTech Test Report

Test Specification

Date Received Date Complete Description

ANSI Z359.13-2013

4.5, 4.6, 4.13.1, 4.13.2, 4.13.3 Energy Absorbing Lanyard Production

Proposed Part #

FallTech

Built By Whom Test Request #

Initiated By

Base Part #

Arrest Distance Max Arrest Force Avg Arrest Force Arrest Distance Max Arrest Force Avg Arrest Force Arrest Distance Max Arrest Force Avg Arrest Force Static Strength Hold Static Strength Hold Static Strength Hold Arrest Distance Max Arrest Force Avg Arrest Force Arrest Distance Max Arrest Force Avg Arrest Force Arrest Distance Max Arrest Force Avg Arrest Force

Test Summary

< 1800 Lbf 1084.6 Lbf Pass

ANSI Z359.13-2013 4.13.1

< 48" 44.0" Pass

< 1800 Lbf 1127.5 Lbf Pass

< 1125 Lbf 807.8 Lbf Pass

Test Specification Test Criteria Test Result Pass/Fail

ANSI Z359.13-2013 4.13.1

< 48" 43.0" Pass

< 1125 Lbf 821.1 Lbf Pass

ANSI Z359.13-2013 4.13.1

< 48" 50.4" Pass

< 1800 Lbf 1364.2 Lbf Pass

< 1125 Lbf 799.3 Lbf Pass

ANSI Z359.13-2013 4.5

< 48" 43.8" Pass

< 1800 Lbf 1039.6 Lbf Pass

< 900 Lbf 770.8 Lbf Pass

ANSI Z359.13-2013 4.5

< 48" 44.6" Pass

< 1800 Lbf 1046.7 Lbf Pass

< 900 Lbf 776.8 Lbf Pass

ANSI Z359.13-2013 4.5

< 48" 44.4" Pass

< 1800 Lbf 1064.0 Lbf Pass

< 900 Lbf 775.6 Lbf Pass

ANSI Z359.13-2013 4.6

> 5000 Lbf 5029.7 Lbf Pass

> 1 Minute 1 Minute Pass

ANSI Z359.13-2013 4.6

> 5000 Lbf 5033.1 Lbf Pass

> 1 Minute 1 Minute Pass

ANSI Z359.13-2013 4.6

> 5000 Lbf 5021.9 Lbf Pass

> 1 Minute 1 Minute Pass

Certificate# TL-594 Testing

FLT-08 Rev. G Page 2 of 8

(6)

Report Prepar Initiated By Base Part# Proposed Part# Test Request#

ANSI 2359.13-2013 4.13.2 ANSI 2359.13-2013

4.13.2 ANSI 2359.13-2013

4.13.2

ANSI 2359.13-2013 4.13.3

ANSI 2359.13-2013 4.13.3

ANSI 2359.13-2013 4.13.3

Lab Quality Manager

!Witnessed by

ACCREDITED

Certificate# TL-594 Testing

all ech

Dan Redden Test Specification

8240 Description

N/A Built By Whom

PC-0843 Date Received

Arrest Distance

s

48"

Max Arrest Force s_ 1800 Lbf

Avg Arrest Force s_ 1125 Lbf

Arrest Dista nee < 48"

Max Arrest Force s_ 1800 Lbf

Avg Arrest Force s_ 1125 Lbf

Arrest Dista nee

s

48"

Max Arrest Force s_ 1800 Lbf

Avg Arrest Force s_ 1125 Lbf

Arrest Dista nee

s

48"

Max Arrest Force s_ 1800 Lbf

Avg Arrest Force s_ 1125 Lbf

Arrest Distance

s

48"

Max Arrest Force s_ 1800 Lbf

Avg Arrest Force s_ 1125 Lbf

Arrest Distance s_48"

Max Arrest Force S 1800 Lbf

Avg Arrest Force S 1125 Lbf

FallTech Testing Laboratory

ANSI Z359.13-2013

1306 S. Alameda Street,

Compton, CA 90221-4803 Tel: (323) 752-0060 www.falltech.com

4.5, 4.6, 4.13.1, 4.13.2, 4.13.3 Energy Absorbing Lanyard

Production BOM No

3/9/2016 Date Complete 3/16/2016

27.4" Pass

1154.6 Lbf Pass

947.4 Lbf Pass

27.2" Pass

1119.2 Lbf Pass

918.7 Lbf Pass

26.8" Pass

1144.8 Lbf Pass

943.1 Lbf Pass

49.0" Pass

1748.3 Lbf Pass

812.3 Lbf Pass

48.8" Pass

1327.7 Lbf Pass

776.2 Lbf Pass

48.8" Pass

1769.4 Lbf Pass

812.2 Lbf Pass

Date 3/22/2016

Date

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005.

This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to the joint ISO-ILAC-IAF Communique dated January 2009).

Faf/Tech Testing Laboratory allows for a +/-5% tolerance on dynamic and static strength test results.

FLT-08 Rev. G

References

Related documents

Distance Learning Credit Activities, Policy 404.1 a2. Carter motion on all UND requests, Stenehjem second

The Lithuanian authorities are invited to consider acceding to the Optional Protocol to the United Nations Convention against Torture (paragraph 8). XII-630 of 3

There are eight government agencies directly involved in the area of health and care and public health: the National Board of Health and Welfare, the Medical Responsibility Board

La formación de maestros investigadores en el campo del lenguaje y más específicamente en la adquisición de la escritura en educación ini- cial desde una perspectiva

For the poorest farmers in eastern India, then, the benefits of groundwater irrigation have come through three routes: in large part, through purchased pump irrigation and, in a

A number of samples were collected for analysis from Thorn Rock sites in 2007, 2011 and 2015 and identified as unknown Phorbas species, and it initially appeared that there were

Quality: We measure quality (Q in our formal model) by observing the average number of citations received by a scientist for all the papers he or she published in a given