If a water heater is installed in a closed water supply system such as one having a back-flow preventer, check valve, water meter with a check valve, etc., in the cold water
When fitting Tempering Valve at the water heater, ensure the cold supply to the Tempering Valve is teed off the cold supply to the water heater down stream from the isolating
4(%2-!, — If a backflow preventer, check valve, or pres- sure reducing valve is piped on cold water inlet of water heater, you must install an expansion tank on cold water supply
A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the T-KJR.. If the T-KJR is installed
1) Close the main water supply valve before continuing with the installation. After the main water supply is shut-off, relieve the water line pressure by opening a faucet. Once the
• If the code requires the gas lines to be tested at a pressure exceeding 14” W.C., the water heater and its manual shut-off valve must be disconnected from the gas
A sediment trap should be installed as close to the inlet of the water heater as practical at the time of water heater installation. The