• No results found

ENERGY SAVING IN LIGHTING FIELD

N/A
N/A
Protected

Academic year: 2021

Share "ENERGY SAVING IN LIGHTING FIELD"

Copied!
20
0
0

Loading.... (view fulltext now)

Full text

(1)

 

ENERGY

 

SAVING

 

IN

 

LIGHTING

 

FIELD

 

 

Automatic  System 

 

HYBRID

 

CONTROL

 

GEAR

   

HPSV/MH

  

LAMPS:

       

50

 

 

400W

  

LAMPS…………..……

 

pag.

   

5

 

ELECTRONIC

 

CONTROL

 

GEAR

   

HPSV/MH

  

LAMPS:

      

70

 

 

150W

  

LAMPS…………..……

 

pag.

  

13

ELECTRONIC

 

CONTROL

 

GEAR

   

Cosmopolis

  

LAMPS:

   

60

 

 

140W

  

LAMPS

HID ENERGY SAVING  PROGRAM   ( UK 02‐2012 )   

(2)

INTRODUCTION 

The need to reduce pollution and costs of public spending is increasingly on the agenda and to that end, the whole world is developing energy  solutions that lead to these results. 

In the segment illumination light sources that exist, while ensuring optimum levels of brightness, enabling significant energy savings. 

The lamps that currently meet these requirements are classified as a gas discharge, and in particular lamps are called high‐pressure sodium vapor  (HPSV) and metal halide (MH). These lamps are  joining the types LED.  Currently much of the Italian public lighting uses mercury vapor light source and a first step towards saving energy would be to replace them with  other sources more efficiently.    This replacement bring, besides the reduction in consumption, the following benefits:  ‐ Reduction of CO2 emissions in the environment (saving 1 kWh = 0.5 kg CO2 savings), this point is critical to public support for the attainment of  the goals of reducing greenhouse gas emissions, as defined in climate energy package EEC 20‐20‐20 2008;  ‐ Reduction in electricity costs;  Similar economic benefits and environmental protection are achieved feeding sources HPSV and MH lamps with dimming systems.  In the following pages APF sets out its proposals, starting with simple but effective applications for these types of lamps, and is preparing proposals  for the LED segment.  For a suitable choice of lamps dimmable systems, please consult the manuals of the manufacturers of lamps, in order to select the appropriate  types.  The consultation itself is also useful in reference to the alleged life of the lamps, which in most cases it is declared and reaches to 30000 hours of  operation. This fact becomes significant compared to the expected life of other light sources such as LED. 

Energy

 

saving

 

lighting

 

at

 

night

 

  The switching on and off a lighting system at night are managed on the basis of the intensity of sunlight present at dusk and dawn. Consequently  the change on road off throughout the year, following the curve of the times of sunset and sunrise.  In contrast, the lighting needs, linked to attendance lit places ( such as traffic along a road ), remain constant throughout the year.  From the graph in fig. 1 it is evident that  the intensity of traffic daily ( week days and holidays ) falls before 50% in time of  between 22 and 06.  Significant energy savings can therefore be achieved  through proper management of lighting at night in both public ( roads, intersections, parks,… )  and private ( gardens, industrial areas,   ) making sure that the power  reduction of a plant with reduced lighting requirements typical of the times at  which attendance is low.  Several types of high pressure sodium lamps and metal halide lamp, you can control, so the savings can be made through bi‐power systems or  power‐electronic hybrids that are switched to a reduced power at night, when the illumination that can be carried by  operating at level of service.  APF systems offer a command  “Intelligent and flexible, “ automatically adjusting power, without the presence of Line Rider, and adapting to all  types of equipment ( excluding systems with centralized controllers ), switching systems using programmable or fixed.  The range of production “ENERGY SAVING “ includes:  - Hybrid system with electromechanical ballast and electronic power switch coupled  to programmable or fixed setting  - Programmable  Electronic Ballasts: programmable or fixed setting.          

       fig.1      Traffic frequentation                       

Operating Characteristics

  Each day the system through an internal timer measuring the total duration of power plant and provides the waiting time before switching. To  obtain this time using an adaptive algorithm, that is able to maintain a constant, varying the total duration of the night, the switching time.   

How accurate can you get? 

Because the algorithm  is based on the annual solar cycle, are not perfectly symmetrical in opposite seasons, there are differences on the switching  times in different seasons. Sun reported the situation to Italy this difference is maintained  ± 20 minutes. 

What happens to the return of summer or the sun? 

Automatically switching time moves one hour following the displacement of the clock. 

How to change the behaviour in different locations around the world? 

For the configuration of the algorithm for calculating the operating system is universal. 

Taking as reference the Italian switching latitudes  there may be difference of up to  ± 20 minutes using the system at the equator  or near the polar  circles. 

What if one day the system is switched to a different time than expected? 

In the event of a power plant run by  Twilight early ( due to bad weather conditions ) the system will switch to a time earlier than the day before.  In the following days, times when the power back to being normal, the system resumes normal operation. 

Other abnormal situations may be: 

‐Power plant for a few hours during the day ( due to extreme weather events ).  The system switches to low power after  the waiting time calculated ( if the power is long enough ), even though we are in broad  daylight, days of   operation  remains  unchanged.  ‐Plant shut down caused by interruption  in the supply of energy.  The system, the return of energy,  partly in conditions of full  power even if was previously under‐saving.  In the days after the system resumes normal operation.  These deviations from normal operation, however, provide a view of the effectiveness of safety and energy saving.  Installation instructions  The system works fine if the power plant is controlled by photoelectric switch or similar devices.  To ensure correct timing of switching is desirable to avoid testing of the phases of  longer than 6 hours.  Otherwise the system realign  its operation within 20 days after the first turn  Pag. 1 

(3)

70  ‐  400 W 

 

HPSV

   

Lamps

 

MH

    

   

Lamps

 

 

 

 

ENERGY

 

SAVING

 

VALUE

 

 

≈  

2350

 

h

 

/

 

anno

       

 ≈  

2930

 

h

 

/

 

anno

 

HYBRID

    

Bi

Level

  

HID

 

For

 

High

 

power

 

Sodium

 

vapour

 

and

 

Metal

 

Halide

 

vapour

 

lamps

 

 

ENERGY

  

SAVING

  

VALUES

 

       calculated   4000 h / year     at the cost of 0,17  € / kWh    Nominal Power       W            Total   W 

50

  

60

 

 

70

  

82

100

 

113

150

  

167

250

 

 

275

  

 

400

  

433

CONSUMPTION     kWh  /  year 

240

 

328

 

452

 

668

 

1100

 

1732

 

COST      €  / year 

40,8

 

55,76

 

76,84

 

113,56

 

187

 

294,44

 

SAVING

 

WITH

  

PROGRAM:

 

2324

 ‐ 

7

 

7

 

h

   

reduction

   (

 ≈  

2350

 

h

 

/

 

year

 

)

    

    CONSUMPTION     kWh  /  year 

191

 

260

 

360

 

527

 

839

 

1330

 

  1650h  x 60W   +   2350h x 39W 

 

1650h  x 82W  +   2350h x 53W  1650h  x 113W +   2350h x 74W  1650h  x 167W  +   2350h x 107W  1650h  x 275W   +   2350h x 164W 

 

1650h  x 433W +   2350h x 262W         €  / year 

32,47

 

44,2

 

61,2

 

89,59

 

142,63

 

226,1

 

SAVING      kWh  / year 

49

 

68

 

92

 

141

 

261

 

402

 

€  / year 

8,33

 

11,56

 

15,64

 

23,97

 

44,37

 

68,34

 

% 

20,4

 

20,7

 

20,4

 

21,1

 

23,8

 

23,2

 

      Kg.   CO2  / year 

24,5

 

34

 

46

 

70,5

 

130,5

 

201

 

SAVING

 

PROGRAM

 

Max.

    

Maximum

     

reduction

    

(

 ≈  

2930

 

h

 

/

 

anno

 

)

     

Start

 

Energy

 

Saving

 

h

 

22

  ‐  

NO

 

STOP

 

CONSUMPTION     kWh  /  year 

176

 

243

 

338

 

492

 

775

 

1231

 

  1070h  x 60W   +   2930h x 39W 

 

1070h  x 82W  +   2930h x 53W  1070h  x 113W +   2930h x 74W  1070h  x 167W  +   2930h x 107W  1070h  x 275W   +   2930h x 164W 

 

1070h  x 433W +   2930h x 262W         €  / year 

29,92

 

41,31

 

57,46

 

83,64

 

131,75

 

209,27

 

SAVING      kWh  / year 

64

 

85

 

114

 

176

 

325

 

501

 

€  / year 

10,88

 

14,45

 

19,38

 

29,92

 

55,25

 

85,17

 

% 

26,7

 

25,9

 

25,2

 

26,3

 

29,5

 

28,9

 

      Kg.   CO2  / year 

32

 

42,5

 

57

 

88

 

162,5

 

250,5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Pag. 2 

(4)

 

50

 

 

400W

  

BI

LEVEL

  

HYBRID

  

RANGE

 

Energy

  

Saving

  

Program

    ‐ 

Mains

  

230V

 

±

 

10%

 

50Hz

 

 

  BI‐LEVEL  PROGRAMMABLE WITH DIP‐SWITCH

 

BI‐LEVEL   NO PROGRAMMABLE 

 

      IP20  class I 

+

  Superimposed  Ignitor 

+

  Electromagnetic Ballast 

+

  HPF Capacitor 

 

PRA  

   

70

 ‐  

400W

 

          Pag. 5 ‐ 7                        IP20  class I 

      ( 0 / 1 fuse )   

Inside  Superimposed  Ignitor  Timed Digital system  3,5 ‐ 4,5kV  /  200pF 

+

  Electromagnetic Ballast 

+

  HPF Capacitor   

IPS

  

   

       

70

 ‐ 

400W

            Pag. 6 ‐ 7                          IP20  class I 

      ( 0 / 1 fuse )   

Inside  Superimposed  Ignitor  Timed Digital system  3,5 ‐ 4,5kV  /  200pF  Inside  Electromagnetic  Ballast  tw130 °C   Conform to  the  ErP – EUP Directive 

+

  HPF Capacitor   

PAK

 

 

     

50

  ‐  

150W

        Pag.8                      IP40  class II 

      ( 0 / 1 /2 fuse )    

Inside  Superimposed  Ignitor  Timed Digital system  3,5 ‐ 4,5kV  /  200pF  Inside  Electromagnetic  Ballast  tw130 °C   Conform to  the  ErP – EUP Directive  Inside  HPF Capacitor  cos  > 0,90       

MB

 

QUICK

  

 

50

  ‐  

150W

    Pag. 9           

MB

   

TB

   

 

50

  ‐  

150W

    Pag. 10           

MB

 

GF

 

QUICK

  

 

250

  ‐  

400W

    Pag. 11      IP66  class II 

       ( 0 / 1  fuse ) 

Inside  Superimposed  Ignitor  Timed Digital system  3,5 ‐ 4,5kV  /  200pF  Inside  Electromagnetic  Ballast  tw130 °C   Conform to  the  ErP – EUP Directive  Inside  HPF Capacitor  cos  > 0,90       

MP

 

FAST

 

 

50

  ‐  

150W

    Pag. 12           

BF

 

PRA

 

  

250

  ‐  

400W

    Pag. 13         

Time       Start h: 23      Stop  h: 06       

%

 

100           80           60           40           Time       h: 22/23/00/01       h: 05/06/07 /NO stop       

%

 

100           80           60           40           Start       Stop      

(5)

50 ‐ 400 W 

HPSV

   

MH

  

Lamps

 

 

 

 

220

 

/

 

240V

  

50/60Hz

 

ta

 

°C

  ‐

30

 

+80

 

 

I

 

Sistemi

 

Intelligent

 

Power

 

Switch

  

sono

 

abbinabili

 

ad

 

Alimentatori

 

elettromagnetici

    

(

 

Hybrid

 

system

 

)

       

e

 

sono

 

inseriti

 

nei

 

sistemi

     

IP40

 

 

PR

 

A

 

400

 

PR

 

A

 

1

 

400

 

Intelligent

 

Power

 

Switch

 

ENERGY

  

SAVING

 

SYSTEM

 

 

 

           ON MAY 2011 THE SYSTEM HAD A RECOGNITION AT ECOHITECH AWARD 2011. IT IS THE MOST IMPORTANT  RECOGNITION AWARD ANNUALLY TO COMPANIES THAT HAVE ACHIEVED SIGNIFICANT RESULTS IN TERMS OF  ENVIRONMENTALLY FRIENDLY EXPLOITING INNOVATION TECHNOLOGIES.                         

AUTOMATIC   PROGRAMMABLE  POWER  REDUCTION System

:   

PRA

 

400

      

Cod.  580000PRA

 

+ Esclusione di ritorno a piena potenza  + Energy Saving  Stop per impostazione a potenza fissa ( max/min )  + Remote control       

+ Exclusion of return to full power + Energy Saving  Stop to set at fix power ( max/min ) + Remote control 

           Peso / weigth:  0,18 Kg                                                          h  ( +/‐20 min )  ≈   h 

start  stop  anno 

22  05  2350  06  2750  07  2850  23  05  2000  06  2350  07  2450  00  05  1620  06  1980  07  2080  01  05  1260  06  1620  07  1720  Factory setting  000000:       start 22h  /  NO stop      

 

AUTOMATIC    POWER  REDUCTION System

:   

PRA

 

1

 

400

      

Cod.  58000PRA1    +   Remote control

 

           Peso / weigth:  0,18 Kg         

2324

7

   

 

Energy

 

Saving

 

start:

  23 h ( 00  legal hour  )  

+/

20

 

min

 

    Energy

 

Saving stop

 after  max. 7 hours 

  

Standard

 

program

 

 ≈  

2350

 

h

 

/

 

year

 

Energy

 

Saving

      

2223

8

   

 

Energy

 

Saving

 

start:

  22 h ( 23 legal hour  )  

+/

20

 

min

 

    Energy

 

Saving stop

 after  max. 8 hours 

(

 

on

 

requeste

 

)

 

 ≈  

2750

 

h

 

/

 

year

 

Energy

 

Saving

      

 

(6)

 

   

70

  ‐  

400W

 

 

HPSV

  

MH

    

Lamps

 

 

 

 

230V

  

50Hz

 

tc

 ‐

30

 

+80°C

 

 

     

IP

 

20

   

class

 

I

 

IPS

  

Power

 

Reduction

 

+

 

Ignition

 

Built

in

 

High

 

performance

  

electronic

 

kit

 

For

 

HID

 

lamps

 

 

      

REFERENCE  STANDARD      

Safety:        EN 61347‐1    /    EN 61347‐2‐1  Performance:    EN 60927  R.F.I. Emissions:  EN 55015  Immunity:  61547                              General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Commutatore  automatico       series  PRA…      Automatic Power Switch ‐ ‐ Accenditore  digitale temporizzato di sicurezza               3,5…4,5 kV    200 pF      Safety  Timed  Digital IGNITOR ‐ ‐ Connettore sezionabile a vite       0,5… 2,5mm²                         Separating  screw  terminal ‐ ‐ Fusibile  sostituibile  a richiesta       Ø 5 x 20mm   10A  250V  T       Replaceable fuse on request ‐

Production

 

range

 

 

Programmable

 

Kit

 

NO

 

Programmable

 

Lamps  W  Type / cod.  Type / cod. Kg.

70

 

/

 

400

 

IPS

 

400

 

580000IPS

 

IPS

 

1

 

400

 

580007IPS

  0,18 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     Vedi  tabella:       pag :4       See table : 

 

 

 

 

 

        + Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa      ( max/min )       

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min ) 

           

 

      Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year )   

 

+  Remote Control   

Lamps  W  Reference APF  Electromagnetic ballast Reference  HPF capacitor > 0,90 250Vl 

    µF ( ±10% ) A ( in )

70

  

 

(0,98A) 

SAPIM

 

VST

 

70/50.3

 

11  0,42 

100

  

(1,20A)

 

SAPIM

 

VT

 

100/70.3

 

12,5  0,53 

150

  

 

(1,80A)

 

SAPIM

 

VST

 

150/100.3

 

TP

 

18  0,78 

250

  

 

(3,00A)

 

SAPIM

 

250/150.3

 

TP

 

32  1,35 

400

  

 

(4,40A)

 

SAPIM

 

400/250.3

 

TP

 

45  2,10   

(7)

70

  

  

400W

 

HPSV

 

/

 

MH

    

Lamps

 

 

Hybrid

   

System

 

230V

   

50Hz

 

IP

 

20

 

Class

 

 

I

 

  

70

  

/

    50W

 

100

  /

    

70W

 

150

  /

  

100W

 

250

  /

  

150W

 

400

  /

  

250W

 

HIBRID

    

Bi

Level

  

HID

 

Energy

  

Saving

 

 

SERIE

 

DA

 

INCORPORARE

       BUILT

IN

 

TYPE

 

       REFERENCE  STANDARD  EN 61347‐1  Safety        EN 61347‐2‐9          EN 60923  Performance    EN 61000‐3‐2  Harmonic Limits    R.F.I. Emissions    Immunity    Flicker       

Lampade

 

Caratteristiche

 

generali

 

Abbinabile a commutatore:                    Coupling with Power Switch :

 

      Automatici Programmabili      PRA 400  /   IPS 400      Automatic  Programmable 

 

      Automatici  fissi      PRA  1  400  /   IPS 1 400       Automatic  fix  

 

‐ Alimentatore a basse perdite      ( tw 130 °C  )      Low losses Ballast, conform to the ‐   conforme alla Direttiva ErP ‐ EUP             to ErP – EUP Directive,  ‐ Abbinabile ad  accenditori a sovrapposizione      F400  /  E400  /  PWE400        Coupling with Superimposed IGNITOR ‐ ‐ Connettore a vite      0,75 to 2,5mm²      Screw  terminals ‐ 

 

 

Control

 

Gear

 

Range

 

Control

 

Gear

 

Characteristics

 

HPF Cap. 

Nominale

 

ridotto 

Type

 

Cod:

 

Δt  Losses 

λ 

appr.

  cos > 0,90 

W

 

A

 

W

 

 

 

K  W*      pF +10%  A in 

70

 

0,98

 

50

 

SAPIM

 

VST

 

70/50.3

 

457535V29

 

75/60  13‐9  0,36‐0,34    11       0,42 

100

 

1,20

 

70

 

SAPIM

 

VT

 

100/70.3

 

451735V00

 

70/55  13‐9  0,41‐0,39    12,5       0,53 

150

 

1,80

 

100

 

SAPIM

 

VST

 

150/100.3

 

TP

 

451135V60

 

75/60  17,5‐13  0,40‐0,38    18       0,78 

250

 

3,00

 

150

 

SAPIM

 

250/150.3

 

TP

 

402135000

 

70/55  25‐19  0,40‐0,38    32     1,35 

400

 

4,40

 

250

 

SAPIM

 

400/250.3

 

TP

 

404235000

 

75/65  33‐22  0,45‐0,43    45     2,10   

Schema di collegamento e dimensioni      Drawing and dimensions

Schema con:      PRA 400 / PRA 1 400      Drawing. with:     Schema con:       IPS 400  ‐  IPS 1 400      Drawing. With:                                           W  L  L1  Kg          W  L  L1  Kg  70  90  61  1,25    250  100  80  3,20  100  90  61  1,25    400  125  110  4,40  150  122  92  2,07                      Pag. 6 

(8)

    

50

   

70

   

100

   

150W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

 

     

IP

 

20

   

class

 

I

 

 

50

  /

  

35W

 

70

  /

  

50W

 

100

  /

  

70W

 

150

  /

  

100W

 

PAK

 

Power

 

Reduction

 

+

 

Ignition

 

+

 

Ballast

 

Built

in

 

Hybrid

 

High

 

performance

  

Control

 

Gear

 

For

 

HID

 

lamps

 

 

      

REFERENCE  STANDARD      

Safety:     EN 61347‐1    /    EN 61347‐2‐9      /    EN 61347‐2‐1  Performance:  EN 60923  /    EN 60927  Harmonic Limits.    EN 61000‐3‐2 

R.F.I. Emissions:  EN 55015  Immunity:  61547                                    General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP       tw 130 °C                   Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Connettore sezionabile a vite             0,5… 2,5mm²                               Separating  screw  terminal ‐ ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

Programmable

 

Kit

 

NO

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Vedi  tabella:       pag :4       See table:

 

+ Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa ( max/min )      

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min )

 

  Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  +  Remote Control 

Production

 

range

 

for

 

Lamps

 

HPSV

  

with

 

Internal

 

Ignitor

 

Lamps  W    Kg.

50

 

/

 

35

 

PAKAP

   

50

 

/

 

35.3

 

/

 

EF

         

455335PAE

 

PAKBT

   

50

 

/

 

35.3

 

/

 

EF

      

455335PKE

 

1,25 

70

 

/

 

50

 

PAKAP

   

70

 

/

 

50.3

 

/

 

EF

      

457535PAE

 

PAKBT

   

70

 

/

 

50.3

 

/

 

EF

      

457535PKE

 

1,35 

Production

 

range

 

for

 

Lamps

 

required

  

Ignitor

 

‐ Accenditore  digitale temporizzato di sicurezza      3,5…4,5 kV    200 pF   ( 1,8…2, 3 kV for 50W Lamps )       Safety  Timed  Digital IGNITOR ‐

Lamps  W

 

      Type / cod. 

Type / cod. Kg. 

50

 

/

 

35

 

PAKAP

   

50

 

/

 

35.3

 

/

 

F

      

455335PAP

 

PAKBT

   

50

 

/

 

35.3

 

/

 

F

      

455335PAK

 

1,25 

70

 

/

 

50

 

PAKAP

   

70

 

/

 

50.3

 

/

 

F

      

457535PAP

 

PAKBT

   

70

 

/

 

50.3

 

/

 

F

      

457535PAK

 

1,35 

100

 

/

 

70  

PAKAP

 

100

 

/

 

70.3

 

/

 

F

      

451735PAP

 

PAKBT

 

100

 

/

 

70.3

 

/

 

F

      

451735PAK

 

1,55 

150

 

/

 

100 

 

PAKAP

 

150

 

/

 

100.3

 

/

 

F

         

451135PAP

 

PAKBT

 

150

 

/

 

100.3

 

/

 

F

      

451135PAK

 

2,40 

       

      PENDING APPROVAL   

Lamps  W  Nominal lamp  Reduced lamp  Saving Δt   K λ L L1 HPF capacitor > 0,90 250Vl

  W        W ( t )  W       W ( t )  W µF ( ±10% )  A ( in )

50

  

(0,53A)

 

50      60  35      39  21  65/45  0,33 – 0,34  140  62  9  0,30 

70

  

(0,98A)

 

70      82  50      53  29  75/60  0,36 – 0,34  140  62  11  0,42 

100

 

(1,20A)

 

100      113  70      74  39  70/55  0,41 – 0,39  140  62  12,5  0,53 

150

 

(1,80A)

 

150      167  100      107  60  75/60  0,40 – 0,38  160  78  18  0,78   

(9)

50

   

70

   

100

   

150W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

ta

 ‐

30

 

+60°C

 

 

      

IP

 

40

 

  

50

  /

  

35W

 

  

70

  /

  

50W

       

100

  /

  

70W

 

 

150

  /

  

100W

 

QUICK

 

MINI

 

BASYC

  

Energy

  

Saving

      

Independent

 

Hybrid

 

High

 

performance

  

Control

 

Gear

 

For

 

HID

 

lamps

 

 

       

REFERENCE  STANDARD      

Safety:        EN 60922     /     EN 61347‐1    /     EN 61347‐2‐9  /    EN 61347‐2‐1    /     EN 60598‐1   /    EN 60598‐2‐1       Performance:        EN 60923  /    EN 60927 

Harmonic Limits:   EN 61000‐3‐2  Immunity:  61547  R.F.I. Emissions:  EN 55015  Flicker:   EN 61000‐3‐3                            General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP              tw 130 °C                Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Condensatore di rifasamento               HPF   cosφ > 0,90                High Power Factor Capacitor ‐ ‐ Accenditore  digitale temporizzato di sicurezza       3,5…4,5 kV    200 pF  ( 1,8…2, 3 kV for 50W Lamps                Safety  Timed  Digital IGNITOR ‐ ‐ Connettore sezionabile a vite        1… 4,0mm²   ( cable 9 – 11mm )       Separating  screw  terminal ‐ ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

Programmable

 

Kit

 

NO

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Vedi  tabella:       pag :4       See table:  

+ Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa ( max/min )      

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min )

 

  Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  +  Remote Control     

Production

 

range

 

 

Programmable

 

connector*

  Type / cod. 

NO

 

Programmable

 

Type / cod.  Lamps  W  Kg.

50

 

/

 

35

 

In 0,30A 

MB

 

APC

 

50.3

 

Q

 

/

 

F

     

 

205330APC

 

MB

 

PRA

 

50.3

 

Q

 

/

 

F

       

20533000A

   2,00 

70

 

/

 

50

 

In 0,41A 

MB

 

APC

 

70.3

 

Q

 

/

 

F

     

 

207530APC

 

MB

 

PRA

 

70.3

 

Q

 

/

 

F

       

20753000A

   2,10 

100

 

/

 

70 

In 0,53A 

MB

 

APC

 

100.3

 

Q

 

/

 

F

   

  

201730APC

 

MB

 

PRA

 

100.3

 

Q

 

/

 

F

     

 

20173000A

  2,15 

150

 

/

 

100 

In 0,78A 

MB

 

APC

 

150.3

 

Q

 

/

 

F

   

 

201130APC

 

MB

 

PRA

 

150.3

 

Q

 

/

 

F

       

20113000A

   2,75          PENDING APPROVAL    * Patented Programmable  connector:  Il connettore consente la sostituzione del sistema mantenendo la programmazione di prima installazione o riprogrammazione The connector allow the replacement of the control gear ( hybrid or electronic ) while maintaining the original programming or changing

          Pag.8   

(10)

 

50

   

70

   

100

   

150W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

ta

 ‐

30

 

+60°C

 

 

      

IP

 

40

 

  

50

  /

  

35W

 

  

70

  /

  

50W

       

100

  /

  

70W

 

 

150

  /

  

100W

 

TB

  

MINI

 

BASYC

  

Energy

  

Saving

       

Independent

 

Hybrid

 

High

 

performance

  

Control

 

Gear

 

For

 

HID

 

lamps

 

 

       

REFERENCE  STANDARD      

Safety:       EN 61347‐1    /     EN 61347‐2‐9  /    EN 61347‐2‐1    /     EN 60598‐1   /    EN 60598‐2‐1       Performance:        EN 60923  /    EN 60927 

Harmonic Limits:   EN 61000‐3‐2  Immunity:  61547  R.F.I. Emissions:  EN 55015  Flicker:   EN 61000‐3‐3                            General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP      tw 130 °C                Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Condensatore di rifasamento               HPF   cosφ > 0,90                High Power Factor Capacitor ‐ ‐ Accenditore  digitale temporizzato di sicurezza       3,5…4,5 kV    200 pF  ( 1,8…2, 3 kV for 50W Lamps                Safety  Timed  Digital IGNITOR ‐ ‐ Connettore a  vite      1… 2,5mm²   ( cable 7 ‐9mm )       Screw  terminal‐ ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

Programmable

 

Kit

 

NO

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Vedi  tabella:       pag :4       See table:  

+ Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa ( max/min )      

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min )

 

  Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  +  Remote Control     

Production

 

range

 

 

Programmable

 

connector*

 

Type / cod. 

NO

 

Programmable

Type / cod. 

 

Lamps  W  Kg.

50

 

/

 

35

 

In 0,30A 

MB

 

AP

 

50.3

 

TB

 

/

 

F

      

  

2053320AP

 

MB

 

PRA

 

50.3

 

TB

 

/

 

F

  

     

20533200A

   2,00 

70

 

/

 

50

 

In 0,41A 

MB

 

AP

 

70.3

 

TB

 

/

 

F

      

  

2075320AP

 

MB

 

PRA

 

70.3

 

TB

 

/

 

F

  

     

20753200A

   2,10 

100

 

/

 

70 

In 0,53A 

MB

 

AP

 

100.3

 

TB

 

/

 

F

 

     

2017320AP

 

MB

 

PRA

 

100.3

 

TB

 

/

 

F

   

   

20173200A

  2,15 

150

 

/

 

100 

In 0,78A 

MB

 

AP

 

150.3

 

TB

 

/

 

F

   

  

2011320AP

 

MB

 

PRA

 

150.3

 

TB

 

/

 

F

    

   

20113200A

   2,75                     

(11)

    

250

   

400W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

ta

 ‐

30

 

+60°C

 

 

      

IP

 

40

 

 

250

  /

  

150W

 

400

  /

  

250W

 

 

MINI

 

BASYC

  

GF

  

Energy

  

Saving

 

Independent

 

Hybrid

 

High

 

performance

  

Control

 

Gear

  

For

 

HID

 

lamps

 

 

       

REFERENCE  STANDARD      

Safety:         EN 61347‐1    /     EN 61347‐2‐9  /    EN 61347‐2‐1    /     EN 60598‐1   /    EN 60598‐2‐1       Performance:        EN 60923  /    EN 60927 

Harmonic Limits:   EN 61000‐3‐2  Immunity:  61547  R.F.I. Emissions:  EN 55015  Flicker:   EN 61000‐3‐3            Dim.  L L1         250W  197 95         400W  222 120                           General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP      tw 130 °C                Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Condensatore di rifasamento               HPF   cosφ > 0,90                High Power Factor Capacitor ‐ ‐ Accenditore  digitale temporizzato di sicurezza       3,5…4,5 kV    200 pF  ( 1,8…2, 3 kV for 50W Lamps                Safety  Timed  Digital IGNITOR ‐ ‐ Connettore sezionabile a vite      1… 4,0mm²   ( cable 9 – 11mm )       Separating  screw  terminal‐ ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

Programmable

 

Kit

 

NO

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Vedi  tabella:       pag :4       See table:  

+ Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa ( max/min )      

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min )

 

  Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  +  Remote Control     

Production

 

range

 

 

Programmable

 

connector*

 

Type / cod. 

NO

 

Programmable

Type / cod. 

 

Lamps  W  Kg.

250

 

/

 

150

 

In 1,35A 

MB

 

GF

 

APC

 

250.3

 

Q

 

/

 

F

 

202130APC

 

MB

 

GF

 

A

 

250.3

 

Q

 

/

 

F

 

2021300GA

   3,80 

400

 

/

 

250 

In 2,10A 

MB

 

GF

 

APC

 

400.3

 

Q

 

/

 

F

 

204230APC

 

MB

 

GF

 

A

 

400.3

 

Q

 

/

 

F

 

2042300GA

  5,10                        * Patented Programmable  connector:  Il connettore consente la sostituzione del sistema mantenendo la programmazione di prima installazione o riprogrammazione The connector allow the replacement of the control gear ( hybrid or electronic ) while maintaining the original programming or changing  

(12)

50

  

70

   

100

   

150W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

ta

 ‐

30

 

+45°C

 

 

      

IP

 

66

 

  

50

  /

  

35W

 

  

70

  /

  

50W

       

100

  /

  

70W

 

 

150

  /

  

100W

 

MINI

 

PLUS

 

FAST

  

Energy

  

Saving

      

Independent

 

Hybrid

 

High

 

performance

  

Control

 

Gear

 

For

 

HID

 

lamps

 

 

       

REFERENCE  STANDARD      

Safety:       EN 61347‐1    /     EN 61347‐2‐9  /    EN 61347‐2‐1    /     EN 60598‐1   /    EN 60598‐2‐1       Performance:        EN 60923  /    EN 60927 

Harmonic Limits:   EN 61000‐3‐2  Immunity:  61547  R.F.I. Emissions:  EN 55015  Flicker:   EN 61000‐3‐3                                General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP      tw 130 °C                Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Condensatore di rifasamento               HPF   cosφ > 0,90                High Power Factor Capacitor ‐ ‐ Accenditore  digitale temporizzato di sicurezza       3,5…4,5 kV    200 pF  ( 1,8…2, 3 kV for 50W Lamps                Safety  Timed  Digital IGNITOR ‐ ‐ Connettore ad innesto rapido       1… 2,5mm²      Patented fast connection             Screwless  terminal ‐ ‐ Pressacavi per cavi:      Ø  mm 10…14   type H07 RN‐F    ( or similar )       Cable gland for cable:  ‐  ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

Programmable

 

Kit

 

NO

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Vedi  tabella:       pag :4       See table:  

+ Esclusione di ritorno a piena Potenza       +  Energy Saving   Stop   per impostazione a   potenza fissa ( max/min )      

+ Exclusion of return to full power 

+ Energy Saving  Stop to set at fix power   ( max/min )

 

  Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  +  Remote Control     

Production

 

range

 

 

Programmable

 

connector*

  Type / cod. 

NO

 

Programmable

 

Type / cod.  Lamps  W  Kg.

50

 

/

 

35

 

In 0,30A 

MPF

 

AP

 

50.3

 

/

 

F

      

1553300AP

 

MPF

 

PRA

 

50.3

 

/

 

F

  

15533000A

  1,60 

70

 

/

 

50

 

In 0,41A 

MPF

 

AP

 

70.3

 

/

 

F

      

1575300AP

 

MPF

 

PRA

 

70.3

 

/

 

F

  

15753000A

  1,65 

100

 

/

 

70 

In 0,53A 

MPF

 

AP

 

100.3

 

/

 

F

 

1517300AP

 

MPF

 

PRA

 

100.3

 

/

 

F

   

15173000A

  1,75 

150

 

/

 

100 

In 0,78A 

MPF

 

AP

 

150.3

 

/

 

F

   

1511300AP

 

MPF

 

PRA

 

150.3

  

/

 

F

    

15113000A

  2,70         

(13)

   

250

   

400W

 

HPSV

  

MH

    

Lamps

 

 

 

230V

  

50Hz

 

ta

 ‐

30

 

+45°C

 

 

      

IP

 

66

 

 

250

  /

  

150W

 

400

  /

  

250W

 

 

BF

 

PRA

   

Energy

  

Saving

       

Independent

 

Hybrid

 

High

 

performance

  

Control

 

Gear

 

For

 

HID

 

lamps

 

 

       

REFERENCE  STANDARD      

Safety:       EN 61347‐1    /     EN 61347‐2‐9  /    EN 61347‐2‐1    /     EN 60598‐1   /    EN 60598‐2‐1       Performance:        EN 60923  /    EN 60927 

Harmonic Limits:   EN 61000‐3‐2  Immunity:  61547  R.F.I. Emissions:  EN 55015  Flicker:   EN 61000‐3‐3                                General Characteristics  Hybrid System ( Electromechanical ballast )

‐ Alimentatore a basse perdite conforme alla Direttiva ErP – EUP      tw 130 °C                Low losses  Ballast, conform  to ErP – EUP Directive ‐ ‐ Condensatore di rifasamento               HPF   cosφ > 0,90                High Power Factor Capacitor ‐ ‐ Accenditore  digitale temporizzato di sicurezza       3,5…4,5 kV    200 pF  ( 1,8…2, 3 kV for 50W Lamps                Safety  Timed  Digital IGNITOR ‐ ‐ Connettore ad innesto rapido       1… 2,5mm²      Patented fast connection             Screwless  terminal ‐ ‐ Pressacavi per cavi:      Ø  mm 10…14   type H07 RN‐F    ( or similar )       Cable gland for cable:  ‐  ‐ Fusibile  sostituibile          Ø 5 x 20mm   10A  250V  T                       Replaceable fuse ‐ ‐ Commutatore  automatico      series  PRA…       Automatic Power Switch ‐

 

NO

 

Programmable

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                Standard Program 2324‐7  Start 23 h   ‐  Stop after max. 7 h       Energy Saving ( ≈  2350 h/year ) 

 

  +  Remote Control  

Production

 

range

 

 

Programmable

 

connector*

  Type / cod. 

NO

 

Programmable

 

Type / cod.  Lamps  W  Kg.

250

 

/

 

150 

In 1,35A 

BF

 

PRA

 

250.3

 

302530PRA

 

4,60 

250

 

/

 

150 

In 1,35A 

400

 

/

 

250 

In 2,10A 

BF

 

PRA

 

400.3

 

304030PRA

  5,90 

400

 

/

 

250 

In 2,10A        Pag. 12 

(14)

 

MULTI

 

LEVEL

     

ELECTRONIC

  

BALLAST

   

RANGE

    

  

Energy

  

Saving

  

Program

     

70

  ‐ 

150W

  

HPSV

 

LAMPS

     

/

       

60

  ‐ 

140W

  

Cosmopolis

 

Lamps

 

  BI‐LEVEL  PROGRAMMABLE WITH  DIP‐SWITCH  TRI‐LEVEL  PROGRAMMABLE  WITH  DIP‐SWITCH  BI‐LEVEL  NO PROGRAMMABLE           

BI

LEVEL

  

PROGRAMMABLE

 

RANGE

 

( La potenza minima è in funzione del tipo di ballast         

The minimun wattage working depending of  ballast type )

TRI

LEVEL

 

PROGRAMMABLE

  

RANGE

 

( La potenza minima è in funzione del tipo di ballast         

The minimun wattage working depending of  ballast type ) 

+ Energy Saving  Stop per impostazione a   potenza fissa ( max/min ) + Energy Saving  Stop per impostazione a   potenza fissa ( max/min )

+ Energy Saving  Stop to set at fix power   ( max/min )

+  Remote Control 

+ Energy Saving  Stop to set at fix power   ( max/min )

+  Remote Control  Programmable  IP20  class I   PR

 

EL

 

400

   

Programmable  IP20  class I   Built‐in    PR

 

EL

 

1

10V

   

PR EL 400 PR EL 1‐10V 580000PRE 58000PR10  

+

+

SWITCHED  Electronic Ballast  IP40  class II   

(

 

pag

 

16

 

HPSV

 

/

 

18

 

COSMOPOLIS

 

)

1‐10V   Electronic  Ballast  IP40  class II  

 

(

 

pag

 

16

 

HPSV

 

/

 

18

 

COSMOPOLIS

 

)

Ballast con linea pilota Ballast con linea pilota Funzionamento anche senza PREL400 Funzionamento anche senza PREL1‐10V

Ballast with pilote line Ballast with pilote line

Working also without PREL 400 Working also without PREL 1‐10

Programmable  IP40  class II  ( 0/1/2 Fuse )  MB

 

GFE

 

DIM

  

(

 

pag

 

16

 

HPSV

 

/

 

18

 

COSMOPOLIS

 

)

Programmable  IP40  class II ( 0/1/2 Fuse ) MB

 

GFE

 

1

10V

 

(

 

pag

 

16

 

HPSV

 

/

 

18

 

COSMOPOLIS

 

)

  Programmable Connector Programmable Connector            

NO

 

Programmable

   

BI

LEVEL

  

RANGE

   ‐    

(

 

pag

 

17

 

HPSV

 

/

 

19

 

COSMOPOLIS

 

)

 

Program CG 24 – 06  Start 24h Stop after max.  6 h EB EXT DIM…CG 24h‐6h Program CG 22 – 06  Start 24h Stop after max.  8 h EB EXT DIM…CG 22h‐6h  

Time       h: 22/23/00/01       h: 05/06/07 /NO stop       

%

 

100           80           60           40          

Start       Stop       Start       Start MIN      Stop MIN     Stop     

Time        h: 22/23      h:00/01       h: 05/06     07/NO stop       

%

 

100           80           60           40          

Time       Start h: 23      Stop  h: 06       

%

 

100           80           60           40          

References

Related documents

The analysis of HF power supply characteristics for RLVD allows you to select the following main advantages: 1) Saving of materials is most significant for HF devices with

While the turnover and sheer number of House members makes a fine- grained analysis of legislator motivations difficult, the smaller size of the Senate can provide some insight

In this section, we use the generalized powerset construction and show how one can determinize arbitrary labelled transition systems obtaining particular in- stances of Moore

While MultiInstance pattern introduced in the previous paragraph implements the ability to create more instances from one node, this pattern focuses on the data aspects of this

Considering that digital storytelling is a powerful pedagogical tool for young children, in this paper, we design an immersive storytelling environment which allows

This thesis focuses on three projects aimed towards improving MST in the waters of the Grand Strand: (1) a cross comparison study between the Escherichia coli

2 Understand the principles and construction of helicopter main and tail rotor transmission systems 3 Know about helicopter structures and their assembly methods and