High-resolution bio-imaging

with

liquid-metal-jet x-ray sources

Hans Hertz

Dept. of Applied Physics

Royal Inst. of Technol. (KTH), Stockholm and

KTH: Ulf Lundström, Daniel Larsson, Anna Burvall, Tunhe Zou, Jakob Larsson

Karolinska Inst.: Marie Henriksson, Ulrika Westermark, Hjalmar Brismar; Lena Scott Excillum AB: Björn Hansson, Oscar Hemberg, Tomi Tuohimaa, Mikael Otendal, Per

(2)

Image quality is source limited

(3)

Electron-Impact X-Ray Sources

Rotating-anode source (1929)

100 kW/mm2

Classic x-ray tube (1895)

1 kW/mm2

Liquid-metal-jet-target source (2003)

>10 MW/mm2

Regenerative, high speed

Hemberg et al, APL (2003); Hemberg et al, Opt. Eng. (2004)

TUBEs 1900 20 60 2000 YEAR

X-Ray Brightness History: Electron-impact sources

E-beam power density  brightness Thermally limited

(4)

The liquid-metal-jet x-ray source:

Choice of anode material

E-Beam Power Density Capacity = vρ(∆Tcp + Evap)

FOM = Z√

(

Tcp+Evap) 0 200 400 600 800 1000 1200 1400 1600 1800 Gallium Germanium Silver Indium Tin Mercury Lead Bismuth Plutonium FOM [const·J/(kg1/2m3/2)] Melting point [°C] FOM [J/(kg1/2m3/2)] Melting point [°C]

Hemberg et al, Opt. Eng. (2004)

__

25 keV

(5)

Early results (<2008):

The liquid-(metal)-jet x-ray source

Power: 50-300 W Power density: >2 MW/mm2 (cf. ~10-100 kW/mm2 existing sources) Jet diameter: 15-200 µm Jet speed: 10-100 m/s Source size: >5 µm

Present data:

Power scalability: >100× Power dens. scal.: >10×

Gallium

Kα Kβ

Tin

Kα Kβ

Future:

Otendal et al, Exp. Fluids (2005); Otendal et al JAP (2007); Otendal et al RSI (2008); Touhimaa et al. APL (2008)

Theory Exp

(6)

Present status:

Liquid-Metal-Jet Microfocus Sources

• GaInSn

• Room temp liquid metal alloy • Metal circulation system

• 5-30 µm spot size • 50-300 W power • 2000 h

• Max: 15 MW/mm2 short term

66 cm

Commercialized by:

0 10 20 30 40 50

Photon Energy [keV]

Brightness

[a.u.] 69% Ga

21% In 10% Sn

(7)

Spot size, stability and brightness

Comparison brightness 50 W/5 m: 1x1011 ph/s×mm2×mrad2×line NEXT: 15 MW/mm2 @ 8 µm for 2000 h Spot size x = 0.07 µm y = 0.09 µm Spot stability 24 h Munich, Oct 2013

(8)

Applications: XRD and SAXS

1.71

S-SAD XRD

Theumatin

Crystal: 0.18×0.20×0.22 mm

Exp. time: 4 hours Resol: 1.7 Å

Data cut off at 2.6Å

SAXS

Rat tail tendon (67 nm period)

LMJ source with

(9)

In/Ga anode

for higher energy and thick-object imaging

Larsson et al, RSI (2011)

• Higher In content (65%) → more 24 keV emission

→ better penetration through e.g., mouse

• Al filtering for reduced dose •Elevated temp operation

(10)

X-ray in-line phase-contrast imaging

with liquid-metal-jet sources

• Simple: no optics, no gratings

• Variations in density cause refraction • Refraction cause edge enhancement • Good at high spatial frequencies

• Requires:

– small x-ray spot

– a high-resolution detector Abs 200 m Phase, M=1.3x More phase, M=4.5x

Test object

Experimental arrangement

(11)

Phase-contrast for enhanced

CO

2

micro-angiography

Phase contrast image Projected density

Burvall et al, Opt. Express (2011)

Data: 360x14 sec Power: 40 W Dose: 160 mGy Observe: 50 m vessles Tomography Phase retrieval

Rat kidney vasculature

SNR2 = 25 for 50 µm vessel in rat kidney

12 mGy

(12)

Quantitative detectability

Ideal observer signal-to-noise ratio (SNR):

u: spatial frequency

∆G : Fourier transform of the signal difference

W : noise power spectrum.

SNR2 = 25 is required to detect

a vessel

Adjust dose to give SNR2 = 25

Lundström et al, PMB (2012a)

How?

Munich, Oct 2013 <8 µm diam vessles! Mouse ear

(13)

Tumours:

Natural-contrast tumour demarcation in mouse

Larsson et al, Med Phys (2013)

Natural contrast Absorption vs phase-contrast Phase-contrast 19 mGy Absorption CT 1.3 Gy

Phase-const Abs contr

(14)

Phase-contrast CO2 microangio:

Limitations

Gas filling

• Depends on gas pressure • Required pressure is P = 4γ/D, D = diameter of vessels γ = surface tension

Photon noise

• Depends on – Exposure time – Radiation dose – Imaging distances

– X-ray source and detector

(15)

Summary & Future

• Liquid-metal-jet sources promise 100× higher brightness

– High-spatial resolution imaging

– Spatial coherence for strong in-line phase contrast

• Phase-contrast imaging

– Micro vasculature imaging with CO

2

– Single-cell-size detail

– Dose levels acceptable for small-animal studies.

• Next

– Source:

• Higher power, higher brightness, shorter exposure times

– In-line CO

2

micro angiography:

• Tumor angiogenesis studies • Plaque

– Comparison between propagation-based and grating-based

phase-contrast imaging

(16)

Biomedical & X-Ray Physics group

Thanks!

Ultrasonics & -fluidics:

Bio-analytics and cell biol.

Optics:

Peripheral vision

Teaching & technical Soft x-rays:

Sources, optics, & microscopy

Hard x-rays:

Sources, optics & imaging

References

Related documents

Governance is bundled by principal component analysis, namely: (i) political governance from political stability and ‘voice and accountability’; (ii) economic

Shortage of Finance: Financeisa principal challenge to micro and small scale enterprises in Ethiopia; finance for MSEs is provided by Micro Financial Institutions followed

Matched sample (paired comparison) of exchange rate growth rate changes prior and post of each event, assuming both series are normally distributed. The Bank of Japan and the

The government of Mongolia had expressed gratitude to the Soviet government for is assistance in constructing the Ulan-Ude to Ulan-Bator track (Petrov 1056:

Buddhism, often described as an austere reli- gion that condemns desire, promotes denial, and idealizes the contemplative life, actually has a thriving leisure culture in

In contrast, macaque AD0516, with serum NAbs and productive virus infection in the lungs, displayed a significantly enhanced proinflammatory macrophage response and

Limited or no published studies, limited multicentre laboratory review, limited data or questionable DST reproducibility (and therefore reliability), instability of drug powder

Another valuable characteristic of computer technology as applied to distance education is the possibility it offers for search on the World Wide Web (WWW). This means that