Reply to On-Line Pre- Bid Meeting Queries
PointNo
Query Response
1 As per clause#4 of Annexure-X, we want to know the
estimated cost of the work, so that we can calculate
average annual financial turnover required as
qualification criteria
An annual financial turnover criterion has been removed from the tender.
2
Sr.No. 42 of BoQ (Section-C, Technical specifications),
specification for excavation of trench - to be mentioned
Tech specification for Item No
42 may be given as below: Digging and Excavation of trenches including Road and concrete cutting for Laying OFC cable should be at least 3 Ft. Below soil surface (Clamping and labeling at every 10 meter as per EIC instructions)
3
With reference to Sr# 8 of page# 116 of Section-D, we would like to request you to review the delivery period and extend it to 60 days as
a) various materials from different manufacturers need
to be organised from different parts of India and other countries
b) Cabling work including civil work like digging, cable
laying etc is involved
Duration of the contract may be extended up to 65 days
4
With reference to Sr# 8 of page# 116 of Section-D, kindly
share the details of drawings required to be submitted and days required from your end to get approval
Delivery period has been revised upto 65 Days instead of 30 Days. Hence, all the activities shall be completed within 65 Days. All documents related to installation shall be
submitted after work
completion. This shall include installation procedure & as built details. No drawing approval is required during the work.
5
As per clause#5.6.1 - we understand that the payment term as
a. 90% of the materials along with taxes in full will be
paid on pro-rata basis on receipt at stores
b. balance 10% of materials and erection & commissioning charges, taxes in full will be released
after commissioning and final acceptance.
Kindly share the details of acceptance procedure for releasing 90% of material cost on receipt of materials at stores on pro-rata basis. Kindly share the details of Final acceptance procedure for releasing balance 10% of material value and 100% of I&C charges
Tender Terms & conditions shall prevail. i.e., as per 1.7 of Special Condition of Contract. (Acceptance of “Terms of
Payment”: 100% payment
shall be released within 30 days after receipt, inspection, installation, commissioning &
final acceptance of the
materials at Kaiga).
6
Warranty period - for how many months? Warranty period will be
minimum 12 months which is already mentioned in technical specification of the tender.
7
We would like to visit your plant to understand and assess the scope of work. Kindly confirm
Yes, you can visit the plant site with prior intimation & by
furnishing the details of
visitors.
8
Operating Temp. for NVR (-10 to 55 degree C) is not supported in commercial grade NVR. Whether 0 to 50 degree support is acceptable?
OK
9
Warranty period - for how many months? 12 months
10
Can we have the complete route layout for OFC and other cables and the Camera locations for both the parts namely:
a. P art-A: CCTV NETWORK ALONG THE BIFURCATION FEN CING BETWEEN KGS: 1-4 AND KAIGA 5&6 AT KAIGA SITE
b. Part-B: FIBRE CABLE LAYING BETWEEN KGS 3&4 CBS GATE, KGS3&4 CAS GATE AND KAIG A 5&6 TIME OFFICE
Already described in Scope of Work document and network diagram as well.
11
Are there any Radioactive area where we have to execute the work?
Non radioactive area.
12
Who will supply the Camera mounting poles OR is it to be fixed on existing poles?
All cameras are to be installed
on existing poles using
mounting frame. Mounting frames are to be provided by supplier.
13
How the 3 core x 2.5 sq.mm, 1 100V grade, PVC insulated, PVC sheathed, multistrand, flexible cable is to be laid? It is not advisable to lay both OFC & this cable in the same duct.
As per our requirement.
14
UTP quantity is 305 x 15 = 4575 metres, whereas 20 mm HDPE is only 3000 metres.
It will be used to cover angles, obstacles & spare.
15
HDPE pipes are not PLB? Even the sizes 32/28 and 20/16 are non-standard for PLB.
As per tender specifications.
16
The Mounting brackets for above camera models should be of OEM make. This clause is not desirable and is highly restrictive.
Suitable make can be used.
17
OUTDOOR RACK 6U is required with UL certification--- can we with RoHS /ISO certificates instead of UL
As per our Specification
18
Is EMD exemption documents to be submitted in hardcopy
EMD is not applicable.
19
Power supply will be provided by NPCIL at single point in ground floor-- but required power cable is 3000 mtr, we will need additional power source at regular interval which NPCIL only can provide
Will be provided along the fencing at maximum possible extent.
20
In BOQ laying of HDPE and OFC are on existing U clamps on existing poles so there is no scope of laying underground- Kindly confirm
Comprising some portion
underground laying.
21
In Boq sr. 39 -Fixing and termination of 24 port UTP Jack panel is mentioned but not supply of the said item. kindly confirm
Its includes supply and
installation.
22
Sr.no 42. Digging and Excavation of trenches including Road and concrete cutting for Laying OFC cable- 400 mtr-- kindly confirm the road size and do we need any permission from other authorities- also confirm the depth size
Depth size is 3 meter and work is within the NPCIL site boundary.
23
In specification of 32CH NVR- The offered NVR should support minimum 32 channels of recording. Redundant recording, holiday recording and capture schedule
configuration.-- kindly confirm REDUNDANT RECORDING feature because in NVR single recording can be done redundant recording if required can be done if we have separate workstation. OR do we need integrated Redundant power unit for NVR
24
Outdoor 6U rack do we need with exact given dimension or as per the requirement at site to house the IT equipments with proper ventilation
As per our requirement
25
Model no. Bullet camera for hikvision is same of PTZ so kindly provide exact model no. of Bullet camera for quoting proper housing.
Model no. of PART-A item no. 21 is DS-2CD2643G0-IZS and item no. 20 is Hikvision DS-2DE4A320IWDE
26
OUTDOOR 6U rack-UL certificate is it mandatory or ISO, RoHS, Crisil rated product will be allowed.
As per our Specification
27
Depth of Digging of Trench and preparation of trench kindly be desired.
Depth size is 3 meter and work is within the NPCIL site
boundary.
28
You are planning to install chinese cameras that is hikvision which has being banned by the govt
We have already purchased the camera.
29
You are going to install hikvision camera which is banned and having security breach
We have already purchased the camera and these are in a isolated secure system.
30
No Brand of Industrial grade switches is mentioned As per our technical
specification requirement.
31
Switches Brand is not Mentioned any third party brand is ok?
As per our requirement
32
We understand that In tender work asked is for Two groups. Please confirm from the boq, which is Part A and which is part B.
Item No. 1 - 24 are for Part-A and item No. 25 - 44 are for Part-B.
33
As per drawing doc , " NETWORK DIAGRAM for C CTV Network, NETWORK DIAGRAM for Time Office Set-up" there is two architecture is mention . We understand that these two are Part A and Part B. Please confirm our understanding.
Yes
34
As per technical doc, we understand that annexure 18-21 is Part B. Please confirm our understanding.
35
In second architecture OF "NETWORK DIAGRAM for Time Office Set-up", connection is between Kaiga 5&6 to Kaiga 3&4 via OFC Cable. As per diagram we understand that we need to provide only 2 no. of layer 2 access switches for Kaiga 3&4 site. Please confirm.
Yes
36
But as per BOQ Qty of layer 2 access switch asked is 4 no. We understand that rest will be for spare. Please confirm our understanding.
2 switches will be used for LAN.
37
Regarding LIU 12 PORT Rack mount, Size get contradicts. Specification is asking for 1 u where as boq is asking for 1.5u. Please confirm the requirement.
1U
38
Dimension of liu asked si 12 PORT FULLY LOAD E RACK MOUNT LIU:- Dimension: 42*410*310 mm (H*W*D) .The dimension of liu may vary OEM to OEM. Request you to accept it as per OEM dimension. Please confirm.
As per our requirement
39
As per specification of 15u and 12u rack, requirement is for 1 year warranty for 15U and 12U Rack. IN Rack warranty is not coming. Request you to remove this line.
As per our requirement
40
For outdoor rack, annexure 8, IP 42 Rating is enough. As it will increase the costing twice. Request you to accept as IP42/ IP55 Rating.
As per our requirement
41
Regarding layer 2 switch, annexure 3, Request you to accept as 8K / 16K Mac address.
As per our requirement
42
Regarding 12 port fiber rack mount LIU, Annexure 7, Can we quote ABS Plastic 64321 - Splice Tray, 24F. As most of the vendor is having Splice tray as Plastic.
As per our requirement
43
We understand that OFC Cable and power cable will lay in single 32 MM HDPE Pipe. And cat 6 cable will lay in 20mm HDPE PIPE. Please confirm our understanding.
This shall be instructed by Engineer in Charge at the time of installation of system.
44
Do we need to provide the camera bracket of the same OEM?
As per our requirement
45
Please confirm the camera mounting type - pole/ wall mount bracket for both camera?
pole
46
We understand that camera installation will be in bidder scope. Please confirm the mounting structure for camera. Is it existing/ we have to provide structure?
Cameras to be mounted on
existing structure of
bifurcation fencing poles.
47
As per BOQ, S.NO. 2, We understand that requirement is for cat 6 UTP Unarmored cable. Please confirm.
48
As per technical specification OF "Supply of Mounting Bracket for 4 MP Network Camera to Suit Model (HIKVISION DS-2DE4425I W- DEUHK) of OEM”, we understand that existing bullet camera is 70 no. But requirement of mounting bracket is only 68 no. we understand that res t of the mounting bracket is existing / in M/ S Npcil scope. Please confirm.
As per our requirement
49
Do we have to integrate all the existing 75 n o. of camera to NEW 32 CHANNEL OF NVR?
All cameras will be configured with 3 NVRs
50
"Qty of NVR is 3 no. How the connection is going to be done. Is all three NVR will get integrated? Or all three will be stand alone a s the distribution switch asked is 1 no. only. Is all NVR will be in same control room? "
Technical configuration of
devices will be discussed and executed by the qualified engineer of contractor with the instructions and planning by engineer in charge of NPCIL at the time of Installation. All NVRs will be in same room.
51
If all 3 NVR are stand alone Then please con firm the no. of camera going to connect in each NVR.
Technical configuration of
devices will be discussed and executed by the qualified engineer of contractor with the instructions and planning by engineer in charge of NPCIL at the time of Installation.
52
"As per boq s.no. 2 and 4 , We understand that 15 no. of cat 6 cable is required i.e. 15*3 05=4575 mtrs . But HDPE required is 3000 mtrs only. As per s.no.19, laying of cat 6 cable qty is also 3000 mtrs . We understand that only 3000 mtrs of cat 6 cable will get utilize and rest will be in spare part. Please confirm our understanding."
As per our requirement
53
We understand that 12 core ofc cable of S.NO. 25 is asked for PART B, .Please confirm our understanding.
Yes
54
We understand that OFC CABLE AS PER S.NO. 25, is required for connecting kaiga 3&4 to kaiga 5&6. Please confirm our understanding.
Yes
55
As per architecture diagram of connection, distance is 1000 mtrs only but as per BOQ Requirement is for 1500 mtrs. We understand that rest 500 mtrs asked is for spare parts only. Please confirm ur understanding.
Yes It will be used to cover angles and obstacles.
56
Do we have to give cable route marker? Please confirm the distance, if required.
Yes. As per instructions of engineer in charge and as actual required at the time of installation.
57
Please confirm the HDPE pipe required for laying of OFC , power and cat 6 cable will lay underground/ on the wall using saddle for PART A. Please confirm.
Both
58
If HDPE will lay underground please confirm the type of soil- hard / soft soil?
Mix
59
We understand that HDPE Sl.no. 26, is required for PART B- HDPE will lay underground. If yes, Please confirm the type of soil- hard/ soft soil?
Mix
60
Do we have to provide GI Pipe for underground (road and concrete cutting) laying of cable?
If required for successful completion of works, yes.
61
We understand that as per BOQ, Requirement is for Parallel mode UPS. I.e. we need to provide parallet UPS qty will be 2 no. As ked qty in boq is 1 no. only. Please confirm our understanding.
In parallel mode 2 UPS systems work as single unit.
62
Please confirm if we are offering 6kVA UPS with inbuilt isolation for parallel mode.
As per our requirement
63
Request you to extend this case for at least 1 week. Due date has been extended
upto 21.09.2020.
64
Respected Sir, Pls. Share Your Direct Email Address & Mob No. So we can send our query in proper excel sheet.
Pls. note our e-Mail ID given in
tender. i.e.,
cmm_kgs@npcil.co.in and
contact No. 08382 - 264141. You can send your detailed query on this e-Mail ID.
65
PLS CONFIRM EMD EXEMPTION CERTIFICATE AND ANY OTHER TENDER DOCUMENTS TO BE SUBMITTED IN HARD COPY.
EMD is not applicable. All the documents shall be uploaded on e-Portal only.
Note: The above clarification shall form a part of Tender Document.
With the above all the bidder queries as on date have been addressed, in case if any queries remain unaddressed, same may please be brought to notice immediately.