LG AIR CONDITIONING
We always pursue highly advanced technologies to improve the quality of your life.
Enjoy a clean, quiet & comfortable life with LG Air Conditioners.
.lgeair
con.com
LG Electronics Air Conditioning Marketing
20 Yeouido-dong, Yeongdeungpo-gu, Seoul 150-721, Korea
Phone: 82-2-3777-1114 E-Mail : [email protected]
http://www.lge.com
For continual product development, LG reserves the right to change specifications without notice.
Contents
LG Electronics,
The World’s Best Seller
06
Single Packaged Type
14
Ducted Split Type
20
Fan Coil Unit
24
MULTI M & M DX
36
Ceiling Concealed Duct
Models Line up
The World’s Number 1 Choice in Air Conditioners!
Single Packaged Type
Ducted Split Type
Btu/h
3~6tons
3~6tons
7.5~30tons
3~5tons
7.5~12.5tons
15~20tons
7,000
9,000
12,000
18,000
22,000
24,000
26,000
30,000
36,000
42,000
48,000
60,000
72,000
80,000
100,000
150,000
Ceiling Concealed Duct Type
Fan Coil Unit Type
* The exact appearance of products may vary from the images shown here.
Single Split Wall Mounted Type
Ceiling Cassette Type
Floor Standing Type
Ceiling and Floor Type
18,000
7,000
Ceiling Concealed Duct Type
06
07
Ceiling Concealed Duct Type
L G A I R C O N D I T I O N E R S 2 0 0 9
Ceiling Concealed Duct Type
Hidden in the ceiling, this model is designed for buildings that require floor
level air conditioning for many individual rooms or large areas, like
restaurants, concert halls and hotels. Installation is not restricted by lighting
fixtures or the building layout, and interior renovation is made easy by
installing ventilation diffusers.
The air volume and sound level is kept constant as designed
regardless of changes in E.S.P.(External Static Pressure)
E.S.P. technology
- Optimizes Duct Installation
- Keeps Capacity & Sound Levels within desired ranges
- Reduces the number of models
Phase control motor technology reduces installation costs. The
desired air flow is obtained by adjusting the phase motor during
installation of the product, giving you more flexibility when
setting up your duct system. The E.S.P can be adjusted linearly
from 0 to 10mmAq.
*E.S.P: External Static Pressure
The integrated PLASMA Air Purifying System removes
microscopic contaminants and dust, eliminates offensive odors
and prevents allergic reactions. It can also be used as an
air-purifying unit only, without running the air conditioner.
Evaluated by CSIRO Australia (DBCE Doc 98/204)
Tested by Korean Food Research Institute and Japanese Environmental Centre and Yonsei Univ. College of Medicine. (Allergy Research Lab.)
PLASMA Air Purifying System (Accessory)
Respirable particles from 5 cigarettes in a sealed room removed by the LG Plasma Air Purifying System.
LG's Plasma Air Purifying unit effectively removes high concentrations of tobacco odors (Confirmed in sensory tests carried out in Korea and Japan.)
In clinical tests, the LG Plasma Air Purifying System reached a satisfaction level of 82% .
• Dust Reduction
• Deodorization
Ceiling Concealed Duct Type
08
09
1) Basic Operation
- With a temperature sensor controlling every diffuser, the
temperature for each zone can be monitored and adjusted
automatically.
2) Control Features
- If every damper is closed, the compressor and outer fan are
turned off, to protect the compressor.
1) Basic Operation
- Linking several units, one Central Control Unit can manage
and turn off several units individually or as a group.
2) Control Features
- Each indoor unit is connected to a Central Control Unit via a
data communication cable and can be operated or turned off
individually or together with a group of units with the central
controller.
- The Central Control Unit can manage up to 8 * 16 indoor
units.
Ceiling Concealed Duct Type
L G A I R C O N D I T I O N E R S 2 0 0 9
Zone Controller (Accessory)
- Eliminates waste of electricity in standby mode.
- Electricity is wasted when an appliance is connected to an
outlet, even though the appliance is turned off.
- Development of a super power-saving SMPS
(Swiching Mode Power Supply)
- Minimal standby power consumption
(90% reduction of standby power).
- No need to pull the main power plug when the appliance is not
in use.
Zero standby power consumption
Central Controller (Accessory)
LG Air Conditioners (Cassette and Duct-type models) can be
installed at long distances (max 50m) and high height
differences (30m) from the outdoor unit.
Plz refer to the picture below.
Ceiling Concealed Duct Type
L G A I R C O N D I T I O N E R S 2 0 0 9
Long Distance Piping High Elevation
Need not control on each times at big diurnal range areas.
Auto Changeover
The dual thermistor control regulates the difference between
the indoor temperature and the temperature of the conditioned
air by monitoring both temperatures, to ensure a uniform room
Two Thermistor Control
If desired, you can set operation times for up to one week in
advance.
Timer-controlled Operation
The High Head Drain Pump pumps water up to 700mm high for
smooth drainage.
High Head Drain Pump (Accessory)
50m
30m
Heating Dehumidifying Cooling Micro Processor Analyze 3 Temperature Measure Periodically Target Temperature Outdoor Temperature Indoor TemperatureLCD Wired Remote Controller
• 24-Hour ON/ OFF Timer with 1 hour intervals • TEST RUN Mode
• Self-Diagnosis feature • 3-Step Fan Speed selection • Operation Indicator • Room Temperature Display • Only 20mm thick
Option
Wireless Remote controller
Pipe fixture Flexible Drain Hose Drain pump Wall Drain pipe 700mm Zone A Zone C Zone D Zone B OnOff 1234 5678 9101112 13141516 1 2 16 Controller #1 OnOff Controller#2 1234 5678 9101112 13141516 Controller #8 OnOff 1234 5678 9101112 13141516 1 2 16
1) Basic Operation
- Linking several units, one Group Control Unit can manage a
number of indoor units.
2) Control Features
- Through a data cable connected to each indoor unit, a group
of units can be managed from the group controller.
- The Group Control function is enabled by cutting an optional
jump wire in the wired remote control, which prevents data
collision.
- One Group Control Unit can control up to 16 indoor units.
Ceiling Concealed Duct Type
L G A I R C O N D I T I O N E R S 2 0 0 9
Group Control
LG’s Outdoor Heat Exchanger is coated with a gold-colored
anti-corrosive epoxy treatment on the aluminum coil, to
prevent corrosion. This maintainsexcellent heat transfer
properties of the coil for an extended time, whereas non-Gold
Fin¢‚ coils progressively lose efficiency due to surface
corrosion. Gold Fin™‚ fin is perfect for areas with high pollution
or locations exposed to saltwater spray from the sea.
Gold Fin™‚ Anti Corrosion
• Long Distance, High Elevation • Weekly Program • Standby Power Zero • Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TB-H246HSS0 24,000 24,000 1, 220~240,50 2,700 / 2,700 12.0 / 12.0 8.89 2.61 18/16.5/14 2.7 37/35/33 55 6 3*2.5 5*0.75*220 880*260*450 870*800*320 35/60 44/85 6.35/15.88 LB-C246HSS1 24,000 -1, 220~240,50 2,750 / 12 / -8.73 -18/16.5/14 2.7 37/35/33 55 6 3*2.5 4*0.75*220 880*260*450 870*800*320 35/60 44/85 6.35/15.88 TB-H186HSS0 18,000 18,000 1, 220~240,50 2,020 / 2,020 9.5 / 9.5 8.91 2.90 16/14.5/13 1.5 36/34/32 55 6 3*2.5 5*0.75*220 880*260*450 870*655*320 35/55 52/107 6.35/15.88 LB-C186HSS1 18,000 -1, 220~240,50 2,020 / 9.5 / -8.91 -16/14.5/13 1.5 36/34/32 55 6 3*2.5 4*0.75*220 880*260*450 870*655*320 35/55 52/107 6.35/15.88
Ceiling Concealed Duct Type
LB-C186HSS1
TB-H186HSS0
LB-C246HSS1
TB-H246HSS0
10
11
2 ... 16
...
Gold Coated Aluminum Uncoated Aluminum
LG Gold Fin™
Corrosion Free
Conventional
Starting to corrode
After 15 Days After 15 Days
• Long Distance, High Elevation • Weekly Program • Standby Power Zero• Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TB-H366GSS0 36,000 36,000 1, 220~240,50 4,100 / 4,100 18.8 / 18.8 8.78 2.57 32/29/26.5 3.5 43/42/40 58 8 3*5.5 5*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88 LB-C366GSS1 36,000 -1, 220~240,50 4,100 / 18.8 / -8.78 -32/29/26.5 3.5 43/42/40 58 8 3*5.5 4*0.75*220 1,180x298x450 870x800x320 38/70 31/69 9.52/15.88 TB-H306GSS0 30,000 30,000 1, 220~240,50 3,400 / 3,400 15 / 15 8.82 2.59 28/26/24 3 43/42/40 56 8 3*3.5 5*0.75*220 1,180x298x450 870x800x320 38/65 31/69 6.35/15.88 LB-C306GSS1 30,000 -1, 220~240,50 3,600 / 17.0 / -8.33 -28/26/24 3 43/42/40 56 8 3*3.5 4*0.75*220 1,180x298x450 870x800x320 38/65 31/69 6.35/15.88
• Long Distance, High Elevation • Weekly Program • Standby Power Zero • Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TB-H428GSS0 42,000 42,000 3, 380~415, 50 5,100 / 5,400 8 / 8.5 8.24 2.41 32/29/26.5 4.5 43/42/40 59 8 5*2.5 5*0.75*220 1,180x298x450 900x1,165x370 38/95 27/55 9.52/19.05 LB-C428GSS1 42,000 -3, 380~415, 50 5,000 / 7.8 / -8.40 -32/29/26.5 4.5 43/42/40 59 8 5*2.5 4*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 9.52/19.05 TB-H368GSS0 36,000 36,000 3, 380~415, 50 4,100 / 4,100 6.3 / 6.3 8.78 2.57 32/29/26.5 3.5 43/42/40 58 8 5*2.5 5*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88 LB-C368GSS1 36,000 -3, 380~415, 50 4,100 / 6.3 / -8.78 -32/29/26.5 3.5 43/42/40 58 8 5*2.5 4*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88
Ceiling Concealed Duct Type
LB-C306GSS1
TB-H306GSS0
LB-C366GSS1
TB-H366GSS0
Ceiling Concealed Duct Type
LB-C368GSS1
TB-H368GSS0
LB-C428GSS1
TB-H428GSS0
• Long Distance, High Elevation • Weekly Program • Standby Power Zero • Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TB-H608RSS0 56,000 58,000 3, 380~415, 50 6,800 / 6,250 10.5 / 9.8 8.24 2.72 50/45/40 5.5 49/47/45 60 10 5*3.5 5*1.25*220 1,230x380x590 900x1,165x370 52/105 24/48 12.7/19.05 LB-C608RSS1 56,000 -3, 380~415, 50 6,800 / 10.5 / -8.24 -50/45/40 5.5 49/47/45 60 10 5*3.5 4*1.25*220 1,230x380x590 900x1,165x370 52/105 24/48 12.7/19.05 TB-H488RSS0 48,000 48,000 3, 380~415, 50 5,600 / 5,000 8.7 / 7.7 8.57 2.81 40/35/30 5 46/44/42 59 10 5*3.5 5*1.25*220 1,230x380x590 900x1,165x370 52/95 24/48 9.52/19.05 LB-C488RSS1 48,000 -3, 380~415, 50 5,750 / 9 / -8.35 -40/35/30 5 46/44/42 59 10 5*3.5 4*1.25*220 1,230x380x590 900x1,165x370 52/95 24/48 9.52/19.05
• Long Distance, High Elevation • Weekly Program • Standby Power Zero • Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
14
15
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
LB-C246HSA4 24,000 -1, 220~240, 50 2,880 / 13 / -8.6 -18/16.5/14 2.50 37/35/33 57 6 3*3.5 4*0.75 880x260x450 870x655x320 35/55 52/106 6.35/15.88 LB-C186HSA4 18,000 -1, 220~240, 50 2,000 / 9.2 / -9.0 -16/14.5/13 2.0 36/34/32 55 6 3*3.5 4*0.75 880x260x450 801x555x262 35/50 63/134 6.35/15.88
Ceiling Concealed Duct Type
LB-C488RSS1
TB-H488RSS0
LB-C608RSS1
TB-H608RSS0
Ceiling Concealed Duct Type
• Long Distance, High Elevation • Weekly Program • Standby Power Zero • Two Thermistor Control • Group Control
• Child Lock Function • Auto Restart • EZ Tuning • Zone Control(Accessory) • High Head Drain Pump(Accessory)
• Wireless Remote Controller(Accessory) • Gold Fin Anti Corrosion(Optional) • PLASMA Air Purifying system(Accessory)
• Central ControllerI(Accessory)
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
LB-C428GSA0 42,000 -3, 380~415, 50 5,000 / 7.8 / -8.4 -32/29/26 4.5 42/40/38 60 8 4*2.5 4*0.25 1,180x298x450 870x1,038x320 38/78 34/73 9.52/15.88 LB-C366GSA0 36,000 -1, 220~240, 50 4,500 / 20.0 / -8 -32/29/26 3.50 42/40//38 59 8 3*5.5 4*0.75 1,180x298x450 870x800x320 38/70 34/73 9.52/15.88 LB-C306GSA0 30,000 -1, 220~240, 50 3,500 / 16.0 / -8.6 -28/26/24 3.00 42/40/38 60 8 3*3.5 4*0.75 1,180x298x450 870x800x320 38/60 34/73 6.35/15.88
• Gold Fin Anti Corrosion • et CoolTM • Auto Cleaning • Auto Restart • Natural Wind By CHAOS Swing
• Wireless Remote Controller • Quiet Operation • Sleep Mode Auto Operation • One-Touch Air Filter(Anti-Bacteria)
• Healthy Dehumidification • 24-Hour ON/OFF Setting Timer
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzPower Input Cooling / Heating W
Running Current Cooling / Heating A Performance
EER Cooling Btu/hr.W
COP Heating W/W
Air Circulation Indoor(H/M/L) CMM
Moisture Removal l /hr
Noise Level Indoor(H/M/L) dB(A)±3
Outdoor Max dB(A)±3
External Static Pressure mmAq
Cable Main No.*(mm2)*Max L.(m)
Conneting No.*(mm2)*Max L.(m)
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD) Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40ft
Service Valve Liquid/Gas ø(mm)
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
LB-C608RSA0 60,000 -3, 380~415, 50 6,500 / 10.2 / -9.2 -50/45/40 5.50 46/44/42 61 10 4*3.5 4*1.25 1,230x380x590 900x1,165x370 52/105 24/49 12.7/19.05 LB-C488RSA0 48,000 -3, 380~415, 50 5,100 / 8.0 / -9.4 -40/35/30 5.00 44/42/40 62 10 4*3.5 4*1.25 1,230x380x590 900x1,165x370 52/95 24/49 9.52/15.88
Ceiling Concealed Duct Type
LB-C306GSA0
LB-C366GSA0
LB-C428GSA0
Ceiling Concealed Duct Type
Single Packaged Type
18
19
Single Packaged Type
L G A I R C O N D I T I O N E R S 2 0 0 9
Single Packaged Type
Economical and user-friendly model, designed for medium-sized houses
and shops. Features include a number of operation modes, auto restart and
a washable anti-bacterial filter.
The unit can be installed outdoors to save valuable indoor
space, or in locations where no ceiling space is available.
Ground or roof installation options provide total flexibility
according to your requirements.
Easy Installation
The all-in-one design, with all access panels located on one
side of the unit and color-coded wiring, greatly facilitates
maintenance and service.
Easy Maintenance & Service
All units are designed for reverse-cycle operation, which means
electric heating functions can be added by specialized dealers.
This model also allows complete control over fresh air intake,
ratio of air purification, as well as monitoring and automatic
zone control (additional features available from specialized
dealers), through the powerful LG control system.
Additional functions available with duct
system
Selecting an air conditioner with the right capacity is very
important. A unit that is too small or too big will not only affect
your comfort, but may also unnecessarily increase your initial
purchasing cost and operational expenses. The LG cooling load
calculation program helps you choose the right system for your
specific needs.
LG’s Cooling Load Calculation Program
A duct system allows you to freely control air-circulation.
Free & Easy Air-Circulation
➊ Roof Jack Installation ➋ Roof Curb Installation ❸ Slab-on-Ground Installation Typical Installation
❸
• Compact & Lightweight Design • U-shape Air Flow • Safety Condenser Fin Guard • Forklift Base rail • Easy access Panel
• Time Delay Relay is Standard Component • Low Pressure Switch is Standard Component • Durable Painted Steel Cabinet
• Scroll Compressor with internal high-pressure & Over-current Protector • Factory Charged Refrigerant
• Direct-drive multi-speed PSC Blower Motor • Direct-drive PSC Condenser Fan Motor • Phase reversal Protection
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzM.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TK-C0608HA0 59,900 -3, 380~415,50 21.6 6,400 56.7 8.0 1,111x824x734 140 30/64/96 TK-C0488HA0 48,400 -3, 380~415,50 17 4,900 45.3 7.9 1,111x824x734 120 30/64/96 TK-C0368HA0 35,700 -3, 380~415,50 13.2 4,000 34 7.7 1,111x824x734 110 30/64/96
• Wired LCD Remote Controller • Easy Installation • Auto Restart • Low Noise Level
• Easy Maintenance & Service • Additional Functions Available with Duct System
Features
Model
Capacity Cooling Btu/hr Heating Btu/hr Electrical Data Power Supply ø,V,HzM.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TK-C0908H00 96,000 -3, 380~415,50 24.7 9,500 81.3 8.5 1,784x1,147x1,202 310 8/18/18 TK-C0728H00 72,000 -3, 380~415,50 22.8 8,600 73.1 7.6 1,784x1,147x1,202 260 8/18/18
Single Packaged Type
TK-C0368HA0
TK-C0488HA0
TK-C0608HA0
Single Packaged Type
TK-C0728H00
TK-C0908H00
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Oversized moter (Accessory) • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Auto Restart
Features
Model
CapacityCooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Power Supply ø,V,Hz
M.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TK-C1508H00 129,600 -3, 380~415,50 33 15,600 155 8.6 2,110x1,250x1,280 400 4/9/18 TK-C1208H00 112,600 -3, 380~415,50 24.9 13,500 104 8.5 2,110x1,250x1,280 400 4/9/18
• Washable Anti-bacteria Filter • Wired LCD Remote Controller • Easy Installation
• Oversized moter (Accessory) • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Auto Restart
Features
22
23
Model
CapacityCooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Power Supply ø,V,Hz
M.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions (WxHxD) mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
GK-C3608H00 360,000 -3, 380~415,50 86.4 33,000 311 10 2,688x1,720x2,220 1,070 2/4/4 GK-C1808C00 175,000 -3, 380~415,50 52.7 18,000 165 9.2 2,230x1,244x1,540 550 3/7/14 GK-C2108C00 197,000 -3, 380~415,50 57 20,500 198 9.2 2,230x1,244x1,540 600 3/7/14 GK-C2408C00 238,900 -3, 380~415,50 68.4 25,000 226 9.2 2,893x1,250x2,200 870 1/4/8 GK-C3008C00 280,400 -3, 380~415,50 80.1 28,500 280.0283 9.2 2,893x1,250x2,200 870 1/4/8
Single Packaged Type
TK-C1208H00
TK-C1508H00
Single Packaged Type
GK-C1808C00
GK-C2108C00
GK-C2408C00
GK-C3008C00
GK-C3608H00
Ducted Split Type
Economical and user-friendly model, designed for medium-sized houses
and shops. Features include a number of operation modes, auto restart and
a washable anti-bacterial filter.
• 4way Convertibility-horizontal(Left & right), up-flow, down-flow • Plastic drain Pan • High efficient Evaporator Coil
• Galvanized Steel with painting • Washable and Anti-fungus Filter • Multi-speed blower • Time delay PCB
• 220V primary & 24V secondary transformer • Defrost sensor • Hi-Reliability Compressor • Factory supplied charge of R-22
• Compressor internal overload protection • Internal pressure relief valve provides high pressure protection for compressor
• Outside pressure taps for refrigerant system check.
Features
Model
CapacityCooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Power Supply ø,V,Hz
M.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD)
Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TN-C0368SA0 37,000 -3, 380~415,50 9.7 4,100 21.6 6 470x1,014x480 870x800x320 59/65 32/66/66 TN-C0488SA0 49,500 -3, 380~415,50 13.9 5,000 50.9 6.2 600x1,135x500 900x1,135x370 63/100 12/26/26 TN-C0608SA0 60,000 -3, 380~415,50 16.5 5,800 53.8 6.2 600x1,135x500 900x1,135x370 65/115 12/26/26
Ducted Split Type
TN-C0368SA0
TN-C0488SA0
TN-C0608SA0
LED Wired Remote Controller
Air Filter Guide
Blower Housing Assembly
‘A’ Type Indoor Coil
• Compact Size • Quick and Easy Service Panels • Anti-fungus, Hygienic and Easy-to-Clean filter
• Convertible lnstallation • Safety Condenser Fin Guard • High/Low Static Driver Kit, Over Sized Motor(Accessory)
• LCD Wired Remote Control
Features
Model
CapacityCooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Power Supply ø,V,Hz
M.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD)
Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TN-C1208T00 111,200 -3, 380~415,50 30 11,800 102 6.3 1,760x890x840 1,330x1,570x740 190/300 6/15/19 TN-C0908T00 80,900 -3, 380~415,50 20 8,100 76.4 6.0 1,760x890x840 855x1,570x740 190/175 6/15/22
• Compact Size • Quick and Easy Service Panels • Anti-fungus, Hygienic and Easy-to-Clean filter
• Convertible lnstallation • Safety Condenser Fin Guard • High/Low Static Driver Kit, Over Sized Motor(Accessory)
• LCD Wired Remote Control
Features
26
27
Model
CapacityCooling (Gross) Btu/hr
Heating Btu/hr
Electrical Data
Power Supply ø,V,Hz
M.C.A(with standard motor)Cooling / Heating Amps
Power Input Cooling / Heating W
Performance
Air Circulation Indoor CMM
Sound Rating bell
Installation & Stuffing
Net Dimensions Indoor mm
(WxHxD)
Outdoor mm
Net Weight Indoor/Outdoor Kg
Stuffing Quantity Without S/Parts 20/40/40ft Hi
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
TN-C1508T00 135,200 -3, 380~415,50 35 13,200 125 8.0 1,760x890x840 1,130x1,180x1,100 190/250 7/14/19 TN-C1808T00 179,700 -3, 380~415,50 57.2 20,400 150 8.0 2,065x680x1,160 1,640x1,130x880 200/280 7/14/19 TN-C2408T00 240,000 -3, 380~415,50 76.2 27,200 200 8.0 1,870x980x1,230 1,840x1,130x970 230/340 7/14/19
Ducted Split Type
TN-C0908T00
TN-C1208T00
Ducted Split Type
TN-C1508T00
TN-C1808T00
TN-C2408T00
Fan Coil Unit
28
29
Fan Coil Unit
L G A I R C O N D I T I O N E R S 2 0 0 9
Fan Coil Unit
The FCU (Fan Coil Unit) is supplied with cold or hot water by the control
center and circulates indoor air through the cooling and heating coils.
The structures using CAD & CAE technology helps users reduce
installation spaces.
Slim and compact design based on CAD/CAE systems enables
user to reduce installation space.
Slim & Compact Size
PCM Fin coated with anti corrosive & hydrophilic layers
prevents corrosion and make itself remains as like initial
condition, therefore it saves power & maintenance cost.
Heat Exchanger fins are coated with anticorrosive & hydrophilic
layers. It prevents the corrosion of heat exchanger. Fins remain
as new even after long time of operation and maintains
efficiency of heat exchanger constant.
Durable & Energy Saving PCM Fin
Easily removable motor & blower and removable panels help
users maintain units more conveniently.
Each unit is designed to occupy a minimum space. This feature,
along with convenient
Easy Maintenance
230
230 260260
LG (WxHxD): 1,090x230x524
The other companies (WxHxD): 1,020x260x515
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • District Cooling / Low Static
Features
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h
Water Flow Rate GPM(US)
Water Pressure Drop kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNC146GCA0 1,422/1,195/948 38,150/35,280/28,217 4,840 30,330 / 9,948 38 / 43 / 48 3 / 8 (9.52) 4R 8C 11FPI 0.345 1.95 3 B 1 / 50 / 220~240 280 5 3.352 1 YBNC036ACA0 416/354/283 10,130/9,144/6,960 1,320 3,740 / 1,227 32 / 35 / 40 3 / 8 (9.52) 4R 8C 11FPI 0.122 1.61 1 B 1 / 50 / 220~240 67 2 1.183 1 YBNC046BCA0 508/424/341 14,252/11,874/9,519 1,850 7,590 / 2,490 28 / 34 / 40 3 / 8 (9.52) 4R 8C 11FPI 0.142 1.69 1 B 1 / 50 / 220~240 75 2 1.381 1 YBNC066CCA0 640/512/430 17,783/15,968/12,590 2,270 11,540 / 3,785 35 / 40 / 43 3 / 8 (9.52) 4R 8C 11FPI 0.189 1.60 1 B 1 / 50 / 220~240 102 2 1.834 1 YBNC086DCA0 869/736/577 24,921/22,656/17,640 3,190 12,050 / 3,952 35 / 40 / 44 3 / 8 (9.52) 4R 8C 11FPI 0.244 1.68 2 B 1 / 50 / 220~240 152 3 2.366 1 YBNC106ECA0 1,100/924/742 28,893/25,999/21,530 3,650 13,920 / 4,566 35 / 40 / 44 3 / 8 (9.52) 4R 8C 11FPI 0.284 1.83 2 B 1 / 50 / 220~240 188 4 2.761 1 YBNC126FCA0 1,242/1,048/848 35,089/31,970/25,624 4,460 17,550 / 5,756 37 / 41 / 45 3 / 8 (9.52) 4R 8C 11FPI 0.325 1.80 2 B 1 / 50 / 220~240 198 4 3.155 1
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • District Cooling / HighStatic
Features
30
31
Fan Coil Unit
YBNC036ACA0
YBNC046BCA0
YBNC066CCA0
YBNC086DCA0
YBNC106ECA0
YBNC126FCA0
YBNC146GCA0
Fan Coil Unit
YBNC126HDA0 YBNC146JDA0
YBNC166KDA0 YBNC186KDA0
YBNC206DLA0
4 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
Synthetic Nylon (optional Aluminum)
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h Water Flow Rate (Middle) GPM(US) Water Pressure Drop (Middle) kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input (Middle) watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNC126HDA0 1,348 / 1,115 / 1,051 37,028 / 31,455 / 28,123 3,800 7,200 / 2,361 50 / 53 / 59 3 / 8 (9.52) 4R 12C 13FPI 0.237 2.39 2 B 1 / 50 / 220~240 330 2 2.66 1 YBNC146JDA0 1,513 / 1,338 / 1,196 43,099 / 36,650 / 32,745 4,520 9,400 / 3,082 51 / 55 / 60 3 / 8 (9.52) 4R 12C 13FPI 0.274 2.41 2 B 1 / 50 / 220~240 440 2 3.01 1 YBNC166KDA0 1,702 / 1,562 / 1,296 47,219 / 41,558 / 37,474 5,120 11,000 / 3,607 49 / 55 / 59 3 / 8 (9.52) 4R 12C 13FPI 0.329 2.29 2 B 1 / 50 / 220~240 480 2 3.07 1 YBNC186KDA0 1,901 / 1,674 / 1,428 51,088 / 45,105 / 39,659 5,560 12,900 / 4,230 51 / 57 / 59 3 / 8 (9.52) 4R 12C 13FPI 0.329 2.59 2 B 1 / 50 / 220~240 550 2 3.07 1 YBNC206DLA0 2,089 / 1,928 / 1,638 55,530 / 47,889 / 41,737 5,900 14,400 / 4,623 53 / 58 / 62 3 / 8 (9.52) 4R 12C 13FPI 0.411 2.30 2 B 1 / 50 / 220~240 650 2 3.80 1
4 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Standard / Low Static
Features
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h
Water Flow Rate GPM(US)
Water Pressure Drop kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNB146GAA0 1,728/1,270/1,082 48,621/43,947/37,020 10,990 31,070 / 10,191 37 / 43 / 48 3 / 8 (9.52) 3R 8C 11FPI 0.345 1.97 3 B 1 / 50 / 220~240 250 5 2.514 1 YBNB036AAA0 306/253/200 12,249/11,294/8,803 2,780 4,950 / 1,624 32 / 35 / 40 3 / 8 (9.52) 3R 8C 11FPI 0.122 1.18 1 B 1 / 50 / 220~240 60 2 0.887 1 YBNB046BAA0 432/379/329 14,876/13,898/10,884 3,400 6,070 / 1,991 28 / 33 / 40 3 / 8 (9.52) 3R 8C 11FPI 0.142 1.47 1 B 1 / 50 / 220~240 70 2 1.036 1 YBNB066CAA0 686/570/484 21,905/19,790/15,968 5,000 16,300 / 5,346 35 / 39 / 42 3 / 8 (9.52) 3R 8C 11FPI 0.189 1.70 1 B 1 / 50 / 220~240 97 2 1.376 1 YBNB086DAA0 859/765/647 27,637/24,839/21,018 6,210 20,510 / 6,727 35 / 39 / 42 3 / 8 (9.52) 3R 8C 11FPI 0.244 1.69 2 B 1 / 50 / 220~240 148 3 1.775 1 YBNB106EAA0 1,059/946/812 31,049/28,490/24,566 7,040 26,630 / 8,735 35 / 40 / 44 3 / 8 (9.52) 3R 8C 11FPI 0.284 1.69 2 B 1 / 50 / 220~240 178 4 2.071 1 YBNB126FAA0 1,182/1,053/929 37,805/34,188/28,081 8,510 28,840 / 9,460 37 / 41 / 45 3 / 8 (9.52) 3R 8C 11FPI 0.325 1.80 2 B 1 / 50 / 220~240 182 4 2.366 1
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Standard / High Static
Features
Fan Coil Unit
YBNB036AAA0 YBNB046BAA0
YBNB066CAA0 YBNB086DAA0
YBNB106EAA0 YBNB126FAA0
YBNB146GAA0
Fan Coil Unit
YBNB126HBA0 YBNB146JBA0
YBNB166KBA0 YBNB186KBA0
YBNB206LBA0
3 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
Synthetic Nylon (optional Aluminum)
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h
Water Flow Rate GPM(US)
Water Pressure Drop kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNB126HBA0 1,238 / 1,052 / 941 38,385 / 33,642 / 29,173 8,640 21,920 / 7,190 44 / 48 / 52 3 / 8 (9.52) 3R 12C 13FPI 0.237 2.47 2 B 1 / 50 / 220~240 334 2 1.99 1 YBNB146JBA0 1,441 / 1,225 / 1,095 43,844 / 37,123 / 33,608 9,890 24,810 / 8,138 46 / 49 / 54 3 / 8 (9.52) 3R 12C 13FPI 0.274 2.48 2 B 1 / 50 / 220~240 396 2 2.18 1 YBNB166KBA0 1,594 / 1,403 / 1,265 47,086 / 41,285 / 37,941 10,700 28,040 / 9,197 47 / 52 / 56 3 / 8 (9.52) 3R 12C 13FPI 0.329 2.29 2 B 1 / 50 / 220~240 428 2 2.30 1 YBNB186KBA0 1,803 /1,591/ 1,400 49,815 / 43,674 / 38,556 11,400 34,040 / 11,165 49 / 54 / 57 3 / 8 (9.52) 3R 12C 13FPI 0.329 2.59 2 B 1 / 50 / 220~240 517 2 2.30 1 YBNB206LBA0 2,006 / 1,759 / 1,548 56,639 / 49,815 / 42,991 12,990 38,300 / 12,562 51 / 55 / 59 3 / 8 (9.52) 3R 12C 13FPI 0.411 2.30 2 B 1 / 50 / 220~240 710 2 2.85 1
4 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Standard / High Static
Features
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h Water Flow Rate (Middle) GPM(US) Water Pressure Drop (Middle) kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input (Middle) watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNC126HBA0 1,348 / 1,115 / 1,051 44,066 / 38,764 / 33,927 8,600 28,300 / 9,279 50 / 53 / 59 3/8 (9.52) 4R 12C 13FPI 0.237 2.39 2 B 1/50/220~240 330 2 2.66 1 YBNC146JBA0 1,513 / 1,338 / 1,196 53,022 / 46,645 / 40,842 10,340 30,000 / 9,836 51 / 55 / 60 3/8 (9.52) 4R 12C 13FPI 0.274 2.41 2 B 1/50/220~240 440 2 3.01 1 YBNC166KBA0 1,702 / 1,562 / 1,296 56,713 / 50,873 / 46,072 11,280 31,800 / 10,426 49 / 55 / 59 3/8 (9.52) 4R 12C 13FPI 0.274 2.41 2 B 1/50/220~240 480 2 3.01 1
• Washable Anti-bacteria Filter • Easy Installation
• Free Easy Air-Circulation • Low Noise Level • Easy Maintenance & Service
• Additional Functions Available with Duct System • Standard / High Static
Features
34
35
Fan Coil Unit
YBNC126HBA0 YBNC146JBA0
YBNC166KBA0
Fan Coil Unit
YBNC186KBA0 YBNC206LBA0
4 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
Synthetic Nylon (optional Aluminum)
Model
PerformanceNominial Air Flow H / M / L CFM
Nominial Total Capacity H / M / L Btu/h Water Flow Rate (Middle) GPM(US) Water Pressure Drop (Middle) kPa / ft.wg.
Indoor Noise Level
Noise Level L / M /H dB(A)
Coil
Tube Size inch(mm)
No. of Rows, Columns & FPI
Face Area sq.m Face Velocity m/s Motor Type No. of motor # Class Power Supply Ph/Hz/V
Total Rating Input (Middle) watt
Fan Material Type No. of Fans # Water Content 3 Rows Liter Drain Pan
Drain Pan (Material / Thickness) Insulator (Meterial / Thickness)
Filter
Material No. of Filter
Specification
Note :Due to our policy of innovation some specifications may be changed without notification.
YBNC186KBA0 1,901 / 1,674 / 1,428 63,412 / 54,814 / 47,326 12,160 36,500 / 11,967 51 / 57 / 59 3/8 (9.52) 4R 12C 13FPI 0.329 2.59 2 B 1/50/220~240 550 2 3.07 1 YBNC206LBA0 2,089 / 1,928 / 1,638 73,802 / 64,129 / 54,814 14,220 54,100 / 17,738 53 / 58 / 62 3/8 (9.52) 4R 12C 13FPI 0.411 2.30 2 B 1/50/220~240 650 2 3.80 1
4 Rows Coil
3 - Speed Permanent Split Capacitor Motor
Galvanized Steel Centrifugal Fan (Forward Curve)
Galvanized Steel / T0.8 PE / T5.0
MULTI
M
DX
36
37
L G A I R C O N D I T I O N E R S 2 0 0 9Multi Mdx are freely interchangeable multi systems with
MPS-controlled, constant speed compressors.
These systems are perfectly suited for tropical conditions.
Multi Mdx are freely interchangeable multi systems with MPS-controlled, constant speed
compressors. These systems are perfectly suited for tropical conditions.
MULTI
M
DX
38
39
L G A I R C O N D I T I O N E R S 2 0 0 9Tropical MPS Multi System Installation
Next Generation LG MPS Tropical Multi System
are freely interchangeable multi systems with MPS-controlled, constant speed
compressors. These systems are perfectly suited for tropical conditions.
Single Piping Type
“MPS Variable Control” is LG’s unique, energy-saving control technology,
which is applied in both the Multi MDX series.
* Made in Thailand
Type
Btu/h
Wall-Mounted
12K
18K
24K
30K
36K
48K
ARTCOOL Mirror
High Staic Duct
Low Staic Duct
4-Way Cassette
Color variable *Metal *Blue *White Wood *CherryOutdoor Unit Line-up
Indoor Unit Line-up
L4UC608FA2 L5UC728FA3 L6UH728FA2 L8UC1008FA3 L8UC1008FA2 L8UC1508FA1
MPS Variable System
- High efficiency
- High reliability
- Long piping & high elevation flexibility
- Max.8 indoor units by simple piping
- Low noise
MULTI
M
DX
40
41
L G A I R C O N D I T I O N E R S 2 0 0 9Tropical MPS Multi System Installation
Next Generation LG MPS Tropical Multi System
Tropical MPS Multi System Solutions
■ Small Office Building
For Commercial Sites
For Residential Sites
MULTI
M
DX
42
43
L G A I R C O N D I T I O N E R S 2 0 0 9Tropical MPS Multi System Installation
Next Generation LG MPS Tropical Multi System
Energy Saving with Tropical MPS Variable Control
Basic Principle of Tropical MPS Variable Control
Long Distance & High Elevation Piping
Simple & Cutting Edge Control System
Tropical Compressor Technology
The Tropical MPS (multi power system) control two or more constant speed compressors, a hot gas bypass circuit and an linear
expansion valve (LEV). With multiple compressors operating according to increasing cooling requirements, considerable amounts of
energy can be saved. In case of a low cooling load, only one compressor will operate. When the cooling load increases, both
compressors will operate and balance the load.
100%
Conventional system
(On/Off Operation)50%
50%
MPS Variable
Control
Power Consumption Comparison
MPS Variable Multi system opeates in one cycle with two compressors. Only one compressor or two compressors run together,
according to the load conditions.With small load. only one compressor completes the cycle. It saves power consumption at low
operation. This concept is explained in the picture below.
BLDC Fan
BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by
35%at full velocity. AC motor is operating at full velocity only, but BLDC Motor can change velocity according to load. Energy efficiency
levels at low velocities in particular have been improved by 65%.
The finely tuned refrigerant return ratio and special accumulator
allow piping lengths of up to 110m at a max. elevation of 45m. The
runback returns refrigerant to the compressor to maintain a safe
level of refrigerant at all times. It allows better flexibility for
installation under difficult structural conditions.
Long Distance &
High Elevation Piping:
Max. Pipe Length:
110m/cycle
- Please Refer to Page 64
The Tropical compressor is highly reliable, even under extreme
conditions (15~60°C average), sandstorms and 24 hour
operation. At extreme temperatures over 54°C only 1 large
compressor operates to protect the smaller compressors and to
prevent the indoor temperature from rising due to repeated OLP
triggering.
INCREASED RELIABILITY
- Overload Protector - High Torque Motor - Special Anti-Wear Coating - High Rigidity Crank Shaft
28
110
±10%
Standard
New Design -muffle -resonator
33
115
±15%
Tropical
Max Press.(kgf/cm
2)
Td (ºC)
Under voltage
Noise
MULTI
M
DX
44
45
L G A I R C O N D I T I O N E R S 2 0 0 9Tropical MPS Multi System Installation
Next Generation LG MPS Tropical Multi System
Flexible Design & Simple Piping
The MPS Variable multi system uses a simple refrigerant pipe to connect one outdoor unit with multiple indoor units.
It is easy to install and very economical.
Various distributors for flexible design
For 2 Room For 3 Room For 4 Room
Connecting distributor without brazing
Direct Connection Type
Various Combination
•Piping length : 50m(A), 50m(B) •Total system piping length : 100m(50+50)
(Please refer to PDB for detail piping spec.)
Installation of outdoor unit in an elevated position Installation of outdoor unit in a lower position
Outdoor Unit (L8UC1008FA3) Short Tube Indoor Unit Indoor Unit 45m Outdoor Unit (L8UC1008FA3) Indoor Unit Indoor Unit 45m A A B B
Distributor Type
The Tropical MPS Multi allows simple piping for easy installation by using branch distributors.
•Total main piping length : 50m(A), 50m(B) With L5UC728FA3, L8UC1008FA3, L8UC150FA1 •Total branch piping length : 60m(L1+L2+L3+L4), 60m(L5+L6+L7+L8)
•Maximum length of single branch piping: 15m(L1, L2, L3,L4, L5, L6, L7, L8) •Total system piping length: 220m = 110m(A+L1+L2+L3+L4)+110m(B+L5+L6+L7+L8)
Maximum elevation from outdoor unit to indoor unit : 45m with L5UC728FA3, L8UC1008FA3, L8UC150FA1
Installation of outdoor unit in lower position Installation of
the outdoor unit in an upper position Outdoor Unit (L8UC1008FA3) Outdoor Unit (L8UC1008FA3) Indoor Unit 45m 45m A B B A L1 L2 L3 L4 L1 L2 L3 L4 L5 L6 L7 L8 L5 L6 L7 L8 Branch Distributor
A,B : Main piping
L1,L2,L3,L4,L5,L6,L7,L8 : Branch piping The specifications above are only for two models, L8UC1008FA3/L8UC1508FA1.
Please refer to the Product Data Book for other models.
Branch Distributor Branch Distributor Branch Distributor Indoor Unit
Distributor
ForConnectable indoor Unit
Power Consumption (W)
Running Current Type (A) Net Dimensions (WxHxD) (mm)
Net Weight (kg)
Piping Connection (Outdoor Unit) Liquid / Gas (mm) Piping Connection (Indoor Unit) Liquid / Gas (mm)
2 indoors 1~2 10 0.05 300 x 150 x 250 4.8 9.52 / 19.05 6.35x2 / 12.7x2 3 indoors 1~3 10 0.05 300 x 150 x 250 4.9 9.52 / 19.05 6.35x3 / 12.7x3 4 indoors 1~4 10 0.05 300 x 150 x 250 5.0 9.52 / 19.05 6.35x4 / 12.7x4 PMBD5420L Unit PMBD5430L PMBD5440L
Notes: 1.BD unit ↔ BD unit, Indoor Unit ↔ Indoor Unit : Max. Height - 10m Set up the BD unit and Indoor Unit in 15m.
2. Piping connectors must fit the piping sizes of the indoor unit to be connected.(If required, use the connector which is included with the indoor unit.) 3. The BD unit should be installed inside the building.
Easy installation with various distributors
A variety of distributors makes installation on any site much easier.
4 Room Type
5~6 Room Type
8 Room Type
46
47
L4UC608FA2 / L5UC728FA3 / L6UH728FA2
Specification
HP
Nomal Capacity Cooling kW
(Min~Rating) Btu/h
Heating kW
Btu/h Nominal Input Cooling kW (Min~Rating) Heating kW Running Current Cooling A
Heating A
Starting Current Cooling/Heating A Power Supply ø, V, Hz Power Supply Cable (outdoor) No.*mm2
Power and transmission cable(outdoor to BD) No.*mm2
Power and transmission cable(BD to indoor) No.*mm2
Dimensions W*H*D mm(inch)
Net Weight kg(Ibs)
Max. Number of Connectable indoor Units Compressor Type
constant speed Qty x Model (A+B) Motor Type (MPS cycle 1) Oil Type
Oil Charge cc Compressor Type
constant speed Qty x Model (C or C+D) Motor Type (Single or MPS cycle 2) Oil Type
Oil Charge cc Refrigerant Charge (at 7.5m) g(oz)
Type
Control EEV
Short tube Heat Exchanger (Row x Column x FPI)*No.
Defrosting Method
Fan motor Capacitor μF/Vac Drive
Discharge direction Side/Top
Air Flow Rate x No.of fan CMM(cfm) Noise Level (H/L) Sound Pressure at 1m dB(A)+3 Piping connections Liquid(ø)(Circuit 1) mm(inch)
Gas(ø)(Circuit 1) Liquid(ø)(Circuit 2) Gas(ø)(Circuit 2)
Max.total Piping m Max. OD~BD Piping m
Max. total sum of BD~ID Piping m Max. OD~ID Piping m Max. OD~ID Piping m Max. Elevation Indoor Unit~Outdoor Unit m Difference Indoor Unit~Indoor Unit m
Multi MDx MPS BD Piping Direct Piping Single L6UH728FA2 3.5~21.1 12,000~72,000 3.5~21.1 12,000~72,000 2.2~7.3 2.8~7.2 4.9~14.7 4.8~14.5 24 3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 806*1,607*730(31.7*63.3*28.7) 190 (419) 6 Twin Rotary 2 x QPT425YAB 3 Phase Induction ATMOS M60/SUNISO 4GSI
1,200 Twin Rotary 1 x QP425YAB 3 Phase Induction ATMOS M60/SUNISO 4GSI
1,200
Cycle 1: 4000(141)/Cycle 2:2000(70.5)
R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit
(079 / - / 079), (085 / - / 096) (2Rx17Cx18)*2+(2Rx36Cx18)*2 Reverse cycle 10/450 Direct drive top 90 (3179) x 1 60 9.52 (3/8) 19.05 (3/4) 6.35 (1/4) 15.88 (5/8) Cycle1:60 / Cycle2:45 Cycle1:30 / Cycle2:30 Cycle1:30 / Cycle2:15 Cycle1:50 / Cycle2: - -30 10 L4UC608FA2 5.3~17.6 18,000~60,000 -2.9~5.7 -5.3~10.2 -24 3, 380~415, 50 5 * 50 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 900*1,165*370 (35.4*45.8*14.5) 104 (230) 4 Twin Rotary 2 x QPT525YAB 3 Phase Induction SUNISO NM56 1,200 -3,400 (120) R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit
-(2R x 26C x 18) * 2 -6/370~400 Direct drive side 80 (2,824) x 1 60 9.52 (3/8) 19.05 (3/4) -60 30 30 -30 10
Notes: 1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27ºC(80.6ºF) DB /19ºC(66.2ºF) WB - Outdoor Temperature 35ºC(95ºF) DB /24ºC(75.2ºF) WB Heating: - Indoor Temperature 20ºC(68ºF) DB /15ºC(59ºF) WB
- Outdoor Temperature 7ºC(44.6ºF) DB /6ºC(42.8ºF) WB Piping Length: - Interconnecting Piping Length 7.5m
- Level Difference of Zero. 2. At least two indoor units should be connected.
L5UC728FA3 3.5~21.1 12,000~72,000 -1.9~6.8 -3.8~12.3 -24 3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 806*1,607*730(31.7*63.3*28.7) 205 (452) 5 Rotary 2 x QPT425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
1,130 Rotary 1 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
1,130
Cycle 1: 4600(162.21)/Cycle 2:2300(81.1)
R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit
(079 / - / 079) (2Rx17Cx18)*2+(2Rx36Cx18)*2 -10/370 Direct drive top 90 (3,179) x 1 60 9.52 (3/8) 19.05 (3/4) 6.35 (1/4) 15.88 (5/8) 110 50 60 50 50 45 10
Specification
HPNomal Capacity Cooling kW
(Min~Rating) Btu/h
Heating kW
Btu/h Nominal Input Cooling kW (Min~Rating) Heating kW Running Current Cooling A
Heating A
Starting Current Cooling/Heating A Power Supply ø, V, Hz Power Supply Cable (outdoor) No.*mm2
Power and transmission cable(outdoor to BD) No.*mm2
Power and transmission cable(BD to indoor) No.*mm2
Dimensions W*H*D mm(inch)
Net Weight kg(Ibs)
Max. Number of Connectable indoor Units Compressor Type
constant speed Qty x Model (A+B) Motor Type (MPS cycle 1) Oil Type
Oil Charge cc Compressor Type
constant speed Qty x Model (C or C+D) Motor Type (Single or MPS cycle 2) Oil Type
Oil Charge cc Refrigerant Charge (at 7.5m) g(oz)
Type
Control EEV
Short tube Heat Exchanger (Row x Column x FPI)*No.
Defrosting Method
Fan motor Capacitor μF/Vac Drive
Discharge direction Side/Top
Air Flow Rate x No.of fan CMM(cfm) Noise Level (H/L) Sound Pressure at 1m dB(A)+3 Piping connections Liquid(ø)(Circuit 1) mm(inch)
Gas(ø)(Circuit 1) Liquid(ø)(Circuit 2) Gas(ø)(Circuit 2)
Max.total Piping m Max. OD~BD Piping m
Max. total sum of BD~ID Piping m Max. OD~ID Piping m Max. total Piping m Max. OD~ID Piping m Max. Elevation Indoor Unit~Outdoor Unit m Difference Indoor Unit~Indoor Unit m
Piping length spec. Multi MDx MPS BD Piping Direct Piping Multi M L8UC1508FA1 5.3~44.0 18,000~150,000 --3.5~16.3 --6.39~29.1 --3, 380~415, 50 5 * 8.4 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 320 (661) 8 Twin Rotary 3 x QPT525Y 3 Phase Induction SUNISO NM56 1200 Twin Rotary 2 x QPT525Y 3 Phase Induction SUNISO NM56 1200 Cycle1:7200(254)/Cycle2:4800(169) R22
2 MPS cycles EEV in BD unit -(2Rx14Cx18)*2+(2Rx30C x18)*1 +(3Rx30Cx18)*1 --10/370 Direct drive top 180 (6357) 60 12.7 (1/2) 25.4 (1) 9.52 (3/8) 19.05 (3/4) 110 50 60 --45 10 L8UC1008FA3 3.5~29.3 12,000~100,000 --1.6~9.9 --3.4~21.8 --3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 250 (551) 8 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
1130 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
1130 4000(141.1)
R22
2 MPS cycle EEV In BD unit (079 / - / 079), (085 / - / 096) (2R x 14C x 18)*2 + (1R x 30C x 18)*2 --10/370 Direct drive top 90 (3179) x 2 60 9.52 (3/8) 19.05 (3/4) 9.52 (3/8) 19.05 (3/4) 110 50 60 50 --45 10
Notes: 1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27ºC(80.6ºF) DB /19ºC(66.2ºF) WB - Outdoor Temperature 35ºC(95ºF) DB /24ºC(75.2ºF) WB Heating: - Indoor Temperature 20ºC(68ºF) DB /15ºC(59ºF) WB
- Outdoor Temperature 7ºC(44.6ºF) DB /6ºC(42.8ºF) WB Piping Length: - Interconnecting Piping Length 7.5m
- Level Difference of Zero. 2. At least two indoor units should be connected.
3. Wiring cable size must comply with the applicable local and national code.
4. The specification may be subject to change without prior notice for purpose of improvement.
L8UH1008FA2 3.5~29.3 12,000~100,000 3.5~29.3 12,000~100,000 1.6~9.9 2.3~9.0 3.4~21.8 4.2~16.0 --3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 250 (551) 8 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
700 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI
700 4000(141.1)
R22
2 MPS cycles EEV in BD unit (079 / - / 079), (085 / - / 096) (2R x 14C x 18)*2 + (1R x 30C x 18)*2 Reverse cycle 10/370 Direct drive top 90 (3179) x 2 60 9.52 (3/8) 19.05 (3/4) 9.52 (3/8) 19.05 (3/4) 60 30 30 50 --30 10
Combination of Indoor and Outdoor Unit
Model Type
Capacity
Wall Mounted
GeneralMirror 4 Way Hight Static Low Static
ARTCOOL
Ceiling Cassette
Ceiling Concealed
Duct
Index
12
18
24
12
18
24
12
18
24
30
36
48
18
24
30
36
48
12
18
24
Btu/h
12,000
18,000
24,000
12,000
18,500
24,000
12,000
18,000
24,000
30,000
36,000
48,000
18,000
24,000
30,000
36,000
48,000
12,000
18,000
24,000
kW
3.52
5.28
7.03
3.52
5.42
7.03
3.2
5.28
7.03
8.79
10.55
14.07
5.28
7.03
8.79
10.55
14.07
3.52
5.28
7.03
up to 4
-•
•
-•
•
-•
•
•
•
•
-•
•
up to 5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
up to 8
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
up to 6
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
up to 8
-•
•
-•
•
-•
•
•
•
•
•
•
•
•
•
-Indoor Units
Number of Connectible Indoor Units
L4UC608FA2 L5UC728FA3 L6UH728FA2 L8UC1008FA3 L8UH1008FA2
L8UC1508FA1
Outdoor Units
Notes:
1. The total capacity index of indoor units is the of capacity index of eachunits and shoul be within the maximum capacity index of the outdoor unit.
Combination Table
L4UC608FA2
L5UC728FA3
Current (A)
Input (W)
Operation
Unit
1 unit
2 units
3 units
4 units
Unit-A
18000 24000 30000 36000 48000 18000 18000 18000 18000 16000 24000 24000 20000 30000 28000 18000 18000 16000 15000 20000 15000Unit-B
-18000 24000 30000 36000 44000 30000 36000 40000 30000 34000 18000 18000 16000 15000 20000 15000Unit-C
-18000 23000 28000 30000 20000 15000Unit-D
-15000Total
18000 24000 30000 36000 48000 36000 42000 48000 54000 60000 54000 60000 60000 60000 62000 54000 59000 60000 60000 60000 60000 2850 2850 3000 5600 6050 5600 5600 6050 5800 6300 6300 6300 6300 6300 6300 5800 5700 6300 6300 5800 5900 5.3 5.3 5.5 9.0 9.2 9.0 9.2 9.6 9.6 9.8 9.6 9.6 10.2 9.6 9.6 10.2 10.2 9.6 9.6 10.2 10.6Combination of Indoor unit(k Btu/h)
Capacity (Btu/h)
Cooling
Notes:
1. Cooling Capacity is based on : indoor temp.27°C(80.6°F) DB, 19°C(66.2°F) WB; outdoor temp. 35°C(95°F) DB
2. The total capacity of indoor unit of "Circuit 1" is up to 36000 Btu/h (10.6kW). The total capacity of indoor unit of "Circuit 2" is up to 24000 Btu/h (7.1kW).
3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
Unit-A
18 24 30 36 48 18 18 18 18 18 24 24 24 30 30 18 18 18 18 24 18Unit-B
-18 24 30 36 48 30 36 48 30 36 18 18 18 18 24 18Unit-C
-18 24 30 36 24 18Unit-D
-18Total
18 24 30 36 48 36 42 48 54 66 54 60 72 60 66 54 60 66 72 72 72Current (A)
Input (W)
Operation
Unit
Circuit1
2
1 unit
1 unit
2 units
3 units
4 units
Unit-A
48000 12000 18000 18000 18000 16000 22000 24000 12000 12000 12000 11110 12000 11110 16670 12000 11000 24000Unit-B
-36000 18000 24000 30000 34000 28000 24000 12000 12000 12000 11110 18000 16670 16670 12000 11000-Unit-C
-12000 18000 24000 27780 18000 22220 16670 12000 11000-Unit-D
-12000 17000-Total
48000 48000 36000 42000 48000 50000 50000 48000 36000 42000 48000 50000 48000 50000 50000 48000 50000 24000 4600 4250 4250 4250 4600 4600 4600 4600 4100 4100 4250 4250 4250 4250 4250 4250 4250 2450 8.2 8.0 8.0 8.0 8.2 8.2 8.2 8.2 7.8 7.8 8.0 8.0 8.0 8.0 8.0 8.0 8.0 4.5Combination of Indoor units (k Btu/h)
Capacity (Btu/h)
Cooling
Notes:
1. Cooling Capacity is based on : indoor temp.27°C(80.6°F) DB, 19°C(66.2°F) WB; outdoor temp. 35°C(95°F) DB 2. The maximum capacity available for this model is 54k Btu/hr (15.8kW).
3. The capacity is based on standard length of interconnecting refrigerant line.
4. The number of indoor units that can be installed is from 2 to 4. Below 2 indoor units, installation is not possible.
5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor unit’s capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.