Catalog

Data Center Solutions

Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision and storage. A lot of servers and data storage devices are needed to cover all required applications and it makes sense for big corporate or public organizations to concentrate all required equipment in one place as a Data Center. Moreover IT Service Providers (IT SP’s) and Storage Service Providers (SSG’s) host equipment centralized for several companies as outsourced service, what also requires high performance Data Centers.

But owing to this concentration of all services to one location, the reliability and availability of the data center becomes very important. Just imagine if a centralized service fails, the whole company or organization is missing this service, what can lead to a serious business downtimes and related huge costs. For this reason the passive infrastructure (the data center cabling system) is a very important objective as it has to provide high speed and long term reliable links between all involved equipment. The international standards for cabling solutions have

addressed all those trends and developed a new part of the cabling standard (EN 50173-5) for data center solutions.

Most important cabling related objectives are:

Highest Quality and Reliability

As in case of Structured Cabling Systems for LAN’s, the passive infrastructure plays an important role for the overall reliability of a Data Center. Only high quality solutions are the basis for lowest possible downtimes and service outages.

High Performance to support various kinds of services

Data Centers have to serve a wide variety of services what need to be supported by the cabling infrastructure. It is important to consider not only the required applications of today, but also those which are coming in future as well.

Shortest deployment time for Moves, Adds and Changes

The initial setup time for servers and data storage equipment is an important operational cost factor in Data Centers. Moreover any required time for later Moves, Adds and Changes need to be kept as short as possible as this means an interruption of services.

Highest Density

Data Centers are implemented in environmentally controlled areas what makes any required space expensive. Higher density options reduce the amount of floor space, rack space, and the associated costs.

Integration into the Infrastructure Management

Intelligent Cabling Solutions gives the advantage to be integrated into the overall infrastructure management. This provides enhanced control about all assets and increases the reliability and availability of the data center drastically.

AMP NETCONNECT has the complete solution for you! Beside of the classical cabling systems, AMP

NETCONNECT developed the MPO Fiber Optic and MRJ 21 Copper Connectivity Solutions, which provide the necessary components for a quick and easy installation of high performance Data Center and Storage Area Network cabling infrastructures. All solutions can be integrated into the AMPTRAC Intelligent Infrastructure

Management System (IIMS).

AMP NETCONNECT

(2)

Catalog

Data Center Solutions

The MPO Fiber Solution terminates 12 fibers in one MPO

connector, which is similar in size to one SC simplex connector. Modular cassettes transition the 12 fibers of the MPO connector to MT-RJ, MT-RJ SECURE, LC or SC type interfaces.

The MRJ 21 Copper System terminates high-performance Powersum 25-pair cable to one MRJ 21 connector, which replaces up to 12 RJ45 connectors. Cassettes break out the cabling to standards-based wiring to support technologies like PoE and VoIP while providing easy migration to Gigabit Ethernet.

The AMPTRAC Intelligent Infrastructure Management System optimizes data center port utilization by accurately tracking and documenting changes as they occur, enabling proactive monitoring, preventing costly errors and downtime and increasing productivity. The easy-to-implement hardware and AMPTRAC/iTRACS cutting-edge software can be integrated into any new or existing network.

Data Center Structure:

Entrance Room - Entrance Facility (EF)

- Access provider demarcation point and service equipment

Main Distribution Area (MDA)

- Central Connection point for the entire Datacenter - Location of Main Cross-Connect (MC)

Horizontal Distribution Area (HDA) - Distribution point for the cabling that serves the equipment areas

Equipment Distribution Area (EDA) - Houses Electronics equipment like Servers, Switches, Telecom Equipments

Zone Distribution Area (ZDA) - Like Consolidation Point (CP)

Backbone Cabling

- Includes cabling from MDA to EF, HDA, TR

Horizontal Cabling

- Defined as cabling from Horizontal

Cross-Connect (HC) to the Equipment Distribution - Star topology with termination on HC in HDA or MDA

There is no general rule, which type of cabling solution has to be implemented where. It is important to perform an detailed analyses about today’s and possible future requirements and services in the data center and afterwards to prepare a careful and future proof design. Making the right decisions and investment will initially save time, money, and frustration in the near term and minimize disruptive upgrades in the future.

As a guideline, it can be assumed that the Main Distribution Area (MDA) and the cabling between MDA and HDA (in fact the data center backbone) have to be designed with highest possible performance (OM3 Fiber Solutions or Category 6 Shielded Twisted Pair to support 10GigaBit applications).

The cabling between HDA and EDA (which includes also the ZDA) is the more application oriented part and the area with most moves, adds and changes. Flexibility, shortest deployment time and highest density are here the main objective and plug-and-play solutions like MPO Fiber and MRJ21 Copper systems are a cost effective alternative to classical cabling systems.

HDA EDA ZDA MDA HC HC HC MC Primary Entrance Room HC Scondary Entrance Room Access Providers Access Providers Access Providers

Offices, Operations Center Support Rooms Telecom Room Interconnect Active Equip. Storage Area Devices etc. Interconnect Active Equipment Interconnect Active Equipment Active Equipment Interconnect Backbone Cabling Backbone Cabling Backbone Cabling Horizontal Cabling Horizontal Cabling Horizontal Cabling

(3)

Catalog

Data Center Solutions

Part Number Description

0-1777052-1 48 Port 1000Base-T Panel, 1U, angled

0-1777053-1 48 Port 1000Base-T Panel, 1U, angled, AMPTRAC 0-1777029-1 24 Port 1000Base-T Panel, 1U, straight

0-1777029-2 24 Port 1000Base-T Panel, 1U, straight, AMPTRAC 0-1435971-1 48 Port 1000Base-T Panel, 1U, straight

0-1777041-1 48 Port 1000Base-T Panel, 1U, straight, AMPTRAC 0-1435965-1 48 Port 100Base-T Panel, 1U, straight

0-1777042-1 48 Port 100Base-T Panel, 1U, straight, AMPTRAC 0-1479459-1 6 Port 1000Base-T Snap-in Cassette

0-1479452-1 12 Port 1000Base-T Snap-in Cassette 0-1479451-1 19” Frontplate Panel, 1U, for up to 3 Cassettes

Part Number Description

x-1499515-x MRJ-21 to MRJ-21, 180° cable exit x-1499510-x MRJ-21 to MRJ-21, 45° cable exit x-1499516-x MRJ-21 to RJ-21 (Telco), 180° cable exit x-1499520-x MRJ-21 to 6xRJ-45 (1000Base-T) x-1499521-x MRJ-21 to 12xRJ-45 (100Base-T) x denotes length: 0-…-1: 1m 1-…-0: 10m 0-…-2: 2m 2-…-0 20m 0-…-3: 3m 3-…-0: 30m 0-…-5: 5m 5-…-0: 50 m

(other lengths available upon request)

MRJ-21/MRJ21 MRJ-21/RJ-21 (Telco) MRJ-21/ RJ-45 Fanout Assembly

AMP NETCONNECT

MRJ-21 Cabling Solution

The “plug&go” MRJ-21 Cabling System was developed especially for data centers and other environments, where high port density with flexible use of rack space is required. The new designed MRJ-21 Connector is optimized for high speed data transmissions like GigaBit Ethernet. The 48 position interface is factory pre-terminated to multipair power-sum cables in different lengths. For the installation in data centers, those pre-terminated and pre-tested trunk cable assemblies only need to be plugged into the rear side of a patch panel.

The corresponding Patch Panels and Snap-in Modules provide sure transmission of 6 times GigaBit Ethernet (4-pairs) or 12 times Fast Ethernet (2-pairs) via just one MRJ-21 Connector. Highest density with up to 48 RJ-45 1000Base-T Ports is provided, which are contacted by 8 MRJ-21 Connectors to the rear side. “Service

Presentation Panels” are created by use of hybrid fan-out cable assemblies with 6 or 12 RJ-45 Plugs to one

MRJ-21 Module. AMPTRAC enabled Patch Panels are also available for a later easy integration of the solution into the Infrastructure Management.

AMP NETCONNECT warrants the sure transmission of: PBX, X.21, V.11, S0 (ISDN), Up0, CSMA-CD 10/100/1000 (Ethernet), Token Ring (4-100Mbit/s), ATM LAN 155Mbit/s.

MRJ-21 Patch Panels and Snap-in Modules

All MRJ-21 Patch Panels feature high-density RJ45 Ports to the front and MRJ-21 Connectors to the rear.

The range of 1U panels are available in different designs:

• 48 Port Angled

(eliminates the need of horizontal cable management)

• 24 or 48 Port Straight

• Modular MRJ-21 Snap-in Cassettes • Classical or AMPTRAC enabled

MRJ-21 Trunk & Fan-out Cable Assemblies

MRJ-21 Cables Assemblies are highest quality factory terminated and 100% tested before shipment, what provides guaranteed performance after fast and easy installation.

(4)

Catalog

Data Center Solutions

Pre-terminated MPO Trunk Cable

Part Number Description

x-1391976-x Multimode, 50/125µ OM2 x-1695135-x Multimode, 50/125µ OM3 XG x-1391977-x Singlemode, 9/125µ OS1

MPO Snap-in Cassettes – Part Numbers:

MPO/MT-RJ 24 Fibers MPO/SC Duplex 12 Fibers MPO/LC Duplex 24 Fibers

Fiber Type

Pairs flipped Pairs straight Pairs flipped Pairs straight Pairs flipped Pairs straight

50/125µ OM2 0-1391922-1 0-1391928-1 0-1391934-1 0-1391940-1 0-1695355-4 0-1695355-3

50/125µ OM3 0-1391931-1 1-1391931-1 1-1695133-1 0-1695133-1 0-1695355-8 0-1695355-7

9 /125µ OS1 0-1391924-1 0-1391930-1 0-1391936-1 0-1391942-1 0-1695355-2 0-1695355-1

Patch Panel, 1U for up to 3 MPO Cassettes

Part Number: 0-1348876-4

MPO Fanout Assemblies (5m):

Part Number Description

0-1391954-5 MPO/12xSC, 50/125µ OM2 0-1695460-5 MPO/12xSC, 50/125µ OM3 (XG) 0-1391957-5 MPO/6xMT-RJ, 50/125µ OM2 0-1695461-5 MPO/6xMT-RJ, 50/125µ OM3 (XG) 0-1391958-5 MPO/6xMT-RJ, 9/125µ OS1 0-1695195-5 MPO/12xLC, 50/125µ OM2 0-1695464-5 MPO/12xLC, 50/125µ OM3 (XG) 0-1695463-5 MPO/12xSC, 9/125µ OS1

Other Lengths or 62.5/125 MM Fibers upon request

MPO Cassettes:

MPO/MT-RJ 12 Fibers MPO/SC Duplex 12 Fibers

Fiber Type

Pairs flipped Pairs straight Pairs flipped Pairs straight

50/125µ OM3 0-1435594-2 0-1435594-1 0-1435688-2 0-1435688-1

9 /125µ OS1 0-1435672-2 0-1435672-1 0-1435689-2 0-1435689-1

Other configurations available upon request

x denotes length:

0-…-1 10m 0-…-5 50m 0-…-2 20m 0-…-9 90m 0-…-3 30m

(other length up to 300m or 62.5/125µ Multimode Fibers available upon request)

MPO Fiber Optic Cabling Solution

Whether the distances between devices are just a few or hundreds of meters, or whether the data rates are 100 Mbit/s, 1 Gbit/s or even 10 Gbit/s, the MPO optical fiber solution is an excellent choice. Standard, basic, modular components are the key to fast deployment, simple installation, capital-effectiveness and network flexibility. Pre-terminated trunk cables, breakout cassettes, and cable assemblies are the basic modular components needed for a complete network.

Trunk cables are pre-terminated at the factory in standard high-density MPO connectors and 100% tested prior to shipment. Each push-pull MPO terminates 12 optical fibers in a single connector similar in size to one SC simplex connector. Once in place, the cable can be connected into patch panels, twelve fibers at a ‘click’.

A wide range of MPO Fiber Cassettes are available in order to provide the transition to other industry standard interfaces like SC, MT-RJ or LC Connectors.

Each cassette is available with flipped or straight pairs.

(please see illustration for correct channel configuration right hand)

TX RX TX RX Standard Patchcord Flipped Standard Patchcord Flipped

MPO Trunk Cable

Straight MPO Cassette Flipped MPO Cassette Straight

(5)

Catalog

Data Center Solutions

Intelligent Infrastructure Management System

Manage your Data Center with highest reliability!

Today’s corporate communication infrastructures as well as those of data centers are continuously becoming more and more complex. This means that Network Management needs to provide additional features with regard to more accurate and reliable information in order to reduce downtimes to a minimum and optimize asset management to a maximum. Those higher level requirements can only be realized if the physical layer (the cabling system) of the network is included into the overall management.

AMPTRAC is the solution. Each port of any type of patch panel

or active equipment are connected to an AMPTRAC Analyzer, which exactly traces automatically all connections in the data center and updates continuously a corresponding data base located on a server. The AMPTRAC IM

(Infrastructure Management) Software provides full control about the whole data center, which eliminates long and expensive downtimes.

Both, the MPO Fiber as well as the MRJ-21 Cabling Solutions are completely prepared for the integration into an AMPTRAC Solution. Just by implementation of the AMPTRAC enabled Patch Panel solutions, the data center will be prepared for a later full upgrade to AMPTRAC.

And finally consider the warranty for your cabling system!

Some suppliers provide you a cable. Some other suppliers provide you connectors and connecting hardware.

AMP NETCONNECT provides you a complete cabling infrastructure based on a more than 60 years experience in interconnection systems. This means that all components of the AMP NETCONNECT Data

Center Solutions are designed together and perform together at the highest possible performance and reliability!

And for that reason, AMP NETCONNECT provides to you as the end user a

25 years warranty for the complete cabling system, because we are sure that it

performs within all specifications over that period of time.

Contact our competent AMP NETCONNECT Partners or your next AMP NETCONNECT Sales Office. We will support you any time!

The IM Software gives a lot of valuable features: • Full visual trace for each link & channel

in the data center

• Virtual wiring closet (full graphic interface for each rack showing all links)

• Graphic interface for all floor plans • Navigation through the whole data center

structure

• Full description for each item (passive&active) in the data center

• Complete change management including creation of work orders.

References

Related documents

The AMP NETCONNECT AMPINNERGY Modular Power Distribution System can be used to deliver power to workstations in raised floor installations through AMP NETCONNECT Access

To meet these increasing demands for bandwidth in the data center, 10 Gb/s applications over balanced twisted-pair cabling, twinax cabling and optical fiber cabling are growing..

ADC's copper and fiber cable, connectivity, and cable management solutions come together to provide a comprehensive data center infrastructure solution that lowers total cost

It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved. Service valves Bronze circulator

Specifically, this study explored whether the perceived risk of intimate partner homicide and gun violence, benefits to engaging in gun confiscation, barriers to gun confiscation,

Siemon offers the broadest range of copper and fiber high speed interconnect assemblies, category cabling and cable management solutions. For more information on Siemon

As mentioned in 2.3.1, the minimum performance class requirement defined by the data center cabling standard for copper cabling systems is Class E A which is backward compatible

H igaonna K anryo Sensei trained his disc ipl es so hard and severely that even Miyag i Choj un Sensei though t more than once abou t quilling.. Sometimes Miyagi