• No results found

Data Sheet Examples

N/A
N/A
Protected

Academic year: 2021

Share "Data Sheet Examples"

Copied!
23
0
0

Loading.... (view fulltext now)

Full text

(1)

J J

TECHNICAL DATA SHEET

TECHNICAL DATA SHEET NozzlesNozzles 01.01.200701.01.2007

NOZZLE

NOZZLE DK

DK 6

6 –

 – 04

04 –

 – A57°C

 A57°C (-

(- T)

T)

Page 1 of 1Page 1 of 1Version 1Version 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Bran

 © FOGTEC Brandschutz dschutz GmbH & Co. KG GmbH & Co. KG ● Schanzen● Schanzenstr. 19A ● 51063 Kstr. 19A ● 51063 Köln ● Germanyöln ● Germany [email protected]

[email protected] ●● www.fogtec.comwww.fogtec.com ● Tel.: +49● Tel.: +49-(0)-221 96 22 30-(0)-221 96 22 30

Description

Description

This nozzle is used for automatic systems (wet pipe, dry pipe and pre-action). It

This nozzle is used for automatic systems (wet pipe, dry pipe and pre-action). It

requires no additional detection system (except pre – action system). In stand-by mode,

requires no additional detection system (except pre – action system). In stand-by mode,

the water is blocked by a piston inside the nozzle. As result of heat, the glass bulb

the water is blocked by a piston inside the nozzle. As result of heat, the glass bulb

bursts and the piston is pushed downwards by a spring. This opens the water way and

bursts and the piston is pushed downwards by a spring. This opens the water way and

water is discharged.

water is discharged.

Optional protective Teflon caps prevent passing contamination inside the nozzle.

Optional protective Teflon caps prevent passing contamination inside the nozzle.

General Properties

General Properties

K – Fa

K – Factorctor :: 1,2001,200

Flow r

Flow r ate (at 10ate (at 100 bar):0 bar): 12,00 l/min12,00 l/min Glass bulb:

Glass bulb: Fast Response 57°CFast Response 57°C Ma

Material nozzle body terial nozzle body and cage:and cage: Stainless steelStainless steel Ma

Material micterial mic ro ro – nozzles:– nozzles: Stainless steel with brass swirling deviceStainless steel with brass swirling device Ma

Material micro terial micro – filter:– filter: Stainless steel with copper sealStainless steel with copper seal Ma

Material O – ring:terial O – ring: NBR*NBR* Ma

Material pistonterial piston :: BrassBrass Material spring:

Material spring: Stainless SteelStainless Steel Ma

Material protectiterial protecti ve cap:ve cap: TeflonTeflon Weight:

Weight: 0,200 kg0,200 kg

* O – ring is recommended to be changed every 10 years * O – ring is recommended to be changed every 10 years

Pa

Part

rt Number

Number

De

Descripscrip tion tion PaPart rt NumberNumber

DK

DK 6 6 – – 04 04 – – A57°C A57°C 3300091833000918 DK

(2)

J J

TECHNICAL DATA SHEET

TECHNICAL DATA SHEET NozzlesNozzles 01.01.200701.01.2007

NOZZLE

NOZZLE DK

DK 5

5 –

 – 11

11  –

 – O

O (-

(- T)

T)

Page 1 of 1Page 1 of 1Version 1Version 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Bran

 © FOGTEC Brandschutz dschutz GmbH & Co. KG GmbH & Co. KG ● Schanzen● Schanzenstr. 19A ● 51063 Kstr. 19A ● 51063 Köln ● Germanyöln ● Germany [email protected]

[email protected] ●● www.fogtec.comwww.fogtec.com ● Tel.: +49● Tel.: +49-(0)-221 96 22 30-(0)-221 96 22 30

Description

Description

This nozzle is used for deluge systems. It requires a system with manual, electric or

This nozzle is used for deluge systems. It requires a system with manual, electric or

pneumatic activation

pneumatic activation. As

. As soon as the system

soon as the system is activated, water mist

is activated, water mist is discharged.

is discharged.

Optional protective Teflon caps prevent passing contamination inside the nozzle.

Optional protective Teflon caps prevent passing contamination inside the nozzle.

General Properties

General Properties

K – Fa

K – Factorctor :: 0,2900,290

Flow r

Flow r ate (at 10ate (at 100 bar):0 bar): 2,90 l/min2,90 l/min Ma

Material nozzle body:terial nozzle body: Stainless steelStainless steel Ma

Material micterial mic ro ro – nozzles:– nozzles: Stainless steel with brass swirling deviceStainless steel with brass swirling device Ma

Material micro terial micro – filter:– filter: Stainless steel with copper sealStainless steel with copper seal Ma

Material O – ring:terial O – ring: NBR*NBR* Ma

Material protectiterial protecti ve cap:ve cap: TeflonTeflon Weight:

Weight: 0,200 kg0,200 kg

* O – ring is recommended to be changed every 10 years * O – ring is recommended to be changed every 10 years

Pa

Part

rt Number

Number

De

Descripscrip tion tion PaPart rt NumberNumber

DK

DK 5 5 – – 11 11 – – O O 3300008033000080

DK

(3)

TECHNICAL DATA SHEET Sockets 01.01.2007

INDUSTRIAL SOCKET OT L12

Page 1 of 1Version 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandsch utz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

Socket is to be used only with FOGTEC nozzles. Socket has one pipe connection in

addition to nozzle inlet. Cutting ring and nut are included to socket assembly.

General Properties

Material (socket and nut s): Stainless steel Material (cutting rin g): Stainless steel

Pipe tolerances: 12mm (ø12x1,0 DIN2391)

Max pr essure: 200 bar

Weight: 0,160 kg

Part Number

Descrip tion Part Number

(4)

TECHNICAL DATA SHEET Sockets 01.01.2007

T-SOCKET OT L12

Page 1 of 1Version 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandsch utz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

Socket is to be used only with FOGTEC nozzles. Socket has two pipe connections in

addition to nozzle inlet. Cutting rings and nuts are included to socket assembly.

General Properties

Material (socket and nut s): Stainless steel Material (cutting rin g): Stainless steel

Pipe tolerances: 12mm (ø12x1,0 DIN2391)

Max pr essure: 200 bar

Weight: 0,340 kg

Part Number

Descrip tion Part Number

(5)

TECHNICAL DATA SHEET Wall Cabinets 01.01.2007

W

 ALL

C

 ABINET

B

 WITH

FOGGUN 2

Version 1 Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

The FOGGUN wall cabinet system is designed for manual fire fighting. It can be either stand-alone or be part of a FOGTEC fixed installation with automatic or open nozzles. The FOGGUN wall cabinet system includes the wall cabinet and the FOGGUN 2 fire fighting gun. The FOGGUN 2 has two different spray pattern settings which can be chosen. The first set-ting creates a very effective fine droplet water mist, so even fluid or dust fires normally can be put out without splashing. The fine mist can be used in conjunction with a centrally locat-ed jet that creates a coarse mist. The central jet is uslocat-ed to achieve greater reach or to ena-ble the use of mist on deep seated fires by using higher momentum of the droplets. The FOGGUN also produces lateral jets which protect the fire fighter from radiated heat.

General Properties

Material of box: Carbon steel and corrosion resistant painting

Colour: Red (RAL3000)

Fire fighting gun: FOGGUN 2:

- Flow 25l/min @ 100 bar - Maximum pressure 120 bar

- 12 side nozzles and 1 center nozzle

Hose: DN12, 35 or 70 meters, stainless steel fittings

Connection t o the system: Stainless steel fitting for pipe L15 (DIN2391)

Part Number

Descrip tion Hose Length Part Number

Wall Cabinet B with FOGGUN 2 30 m 34000051

(6)

J

TECHNICAL DATA SHEET Section Valves 01.01.2007

S

ECTION

V

 ALVE

 – S

OLENOID

G 1“ (DN25)

Version 1 Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected]www.fogtec.com● Tel.: +49-(0)-221 96 22 30

Description

The section valve is meant to be used with deluge system and open nozzles. The pressure range of valve is designed for pump systems.

The section valve is a 2/2 – way solenoid valve that is controlled by an external fire detection system. They can be installed in different locations or they can be centralized in a valve station with a separate supply pipe to each section, or decentralized at each distribution point from the main high pressure sup-ply pipe to the individual sections.

The test connection is used for air/water bleeding and testing the function of the solenoid section valve.

General Properties

Materials (contact to water): Stainless Steel

Connections: BSP - ISO 1719-1

Valve operation : Normally Closed

Maximum operating pressure: 150 bar

Solenoids: 24V(1,9A), 110V(0,42A), 230V(0,2A)

Part Number

Descrip tion Part Number

SECTION VALVE - SOLENOID G1”(150bar) – 24V 35000074 SECTION VALVE - SOLENOID G1”(150bar) – 110V 35000095 SECTION VALVE - SOLENOID G1”(150bar) – 230V 35000025

(7)

J

TECHNICAL DATA SHEET Section Valves 01.10.2008

S

ECTION

V

 ALVE

 – OH G 1“ (DN25)

Version 1 Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected]www.fogtec.com● Tel.: +49-(0)-221 96 22 30

Description

Valve is meant for automatic systems where the main pipes are wet until automatic nozzles. The section valve is especially design for Ordinary Hazard Group 1 applications. The section valve groups nozzles to separate zones. The section valve has several functions which are following:

 A. Detection of activated zone and giving an alarm signal B. Closing section manually

C. Test connection for regular operation tests without activating nozzle

D. Check valve function allowing drainage of main pipes without draining section piping E. Pressure gauge for visual pressure level check

The section valve can be equipped on request with limit switch to control the portion of manual closing valve. The section valve will be delivered without fittings.

General Properties

Materials (contact to w ater): Stainless Steel / Brass

Connections: ISO 1719-1

Maximum operating pressure: 140 bar

Pressure loss: 3.5bar @ 150l/min

Flow switch: Max 200V, 1A, 20VA

Pressure gauge: 0-250bar

Part Number 

Descrip tion Part Number

SECTION V ALVE– OH G1 (140bar) Standard 35000255 SECTION V ALVE– OH G1 (140bar) with limit switch on request

(8)

J

TECHNICAL DATA SHEET Section Valves 01.01.2007

S

ECTION

V

 ALVE

 – P

NEUMATIC

G 1“ (DN25)

Version 1

Page 1 of 1

Fogtec Brandschut z GmbH & Co. KG Schanzenstr. 19 A D–51063 Köln (Cologne) Tel: +49-221-96223-0 Fax: +49-221-96223-30 [email protected] www.fogtec.com

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. The document is protected under copyright law. All rights with regard to the contents are reserved. These documents are to be treated confidentially. They may not be copied and third parties may not be allowed access to them without written consent. They are to be returned to us on request. These documents may not be translated, microfilmed nor stored or further processed in electronic systems without written consent. In the case of contravention of our rights legal action will be taken. Any rights to claim compensation are reserved

Description

This valve is meant for deluge systems where the main pipes are wet until section valves. Section piping is dry and only open nozzles are used.

The valve combines following parts.

 A. Manual service valve, B. Testing connection and C. pneumatic driven main valve.

General Properties

Materials: Stainless Steel

Connections: BSP - ISO 1719-1

Valve operation: Normally Closed

Maximum operating pressure: 120 bar

 Ai r s up pl y: 6 bar

Power supply: 24 V, DC

Part Number

Descrip tion Part Number

(9)

J

TECHNICAL DATA SHEET Section Valves 01.01.2007

S

ECTION

V

 ALVE

 – P

RE

-

 ACTION

G 1“ (DN25)

Version 1

Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected]www.fogtec.com● Tel.: +49-(0)-221 96 22 30

Description

This valve is to be used in water mist systems with automatic nozzles and wet pipe work until the section valve, where the pipework after section valve shall be under pressurized air in stand-by situation.

The valve combines following parts.

 A. Manual service valve, B. Two pressure gauges, C. Pressure sensor, D. Testing connection and E. Pneumatic driven main valve.

General Properties

Materials: Stainless Steel

Connections: BSP - ISO 1719-1

Valve operation: Normally Closed

Maximum operating pressure: 120 bar

 Ai r s up pl y: 6 bar

Power supply: 24 V, DC

Part Number

Descrip tion Part Number

(10)

TECHNICAL DATA SHEET Cylinder systems 01.01.2007

80-

LITRE

M

 ASTER

M

ODULE

E

LECTRIC

R

ELEASE

/D

RY

P

IPE

S

YSTEM

Version 1 Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected]www.fogtec.com● Tel.: +49-(0)-221 96 22 30

Description

The activation is triggered by an electric signal. The nitrogen cylinder valve is a solenoid op-erated valve with manual override for safety reasons in case of electric failure. After activa-tion the nitrogen is released to the slave module which will pressurize the pipe work and the nozzles starts the extinguishing. A pressure switch in the water manifold of the slave module gives a message of activated system.

General Properties

Nitrogen cy linder : 1 x 80 litre (pressure 200 bar at 20°C)

Release method: Solenoid valve (electric signal or manual override) Compatible Slave Modules: 31100380, 31100381, 31100382, 31100383,

31100384, 31100385 Connections:

Slave port Stainless steel fitting for pipe L12 (DIN2391)

N2 filling port W21,8x1/14” (DIN477)

Electric components:

Solenoid 24V (10W) available also in 230V on request

Pressure switch 230V (max. 6A), set value 30bar

Part Number

Descrip tion Part Number

(11)

TECHNICAL DATA SHEET Cylinder systems 01.01.2007

80-

LITRE

S

LAVE

M

ODULE

6

 X

80

L

D

RY

P

IPE

S

YSTEM

Version 1 Page 1 of 1

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.

 © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected]www.fogtec.com● Tel.: +49-(0)-221 96 22 30

Description

The activation is triggered by pressure increase caused by activation of the master cylinder.  After activation the nitrogen is released to the water cylinder which will pressurize the pipe

work and the nozzles starts the extinguishing. A pressure switch in the water manifold gives a message of activated system. This module shall only used in combination with dry pipe system master modules.

General Properties

Water cylind er: 4 x 80 litre

Nitrogen cylinder: 1 x 80 litre (pressure 200 bar at 20°C)

Release method:  Activated by Dry Pipe System Master Module

Compatible Master Modul es: 31100311, 31100316 Connections:

Water port Stainless steel fitting for pipe L12 (DIN2391)

N2 filling port W21,8x1/14” (DIN477)

Part Number

Descrip tion Part Number

(12)

TECHNICAL DATA SHEET Pump systems 00.00.2007

P

UMP

U

NIT

2

X

120 L/MIN

 A

UTOMATIC

Version 1 Page 1 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

This 2x120 l/min pump unit is designed to be used in automatic systems. The pump unit is built modular and with reduced number of components. The jockey pump is meant to keep the pre-pressure of approx. 20bar in wet pipes. The high-pressure pump type used is a triplex plunger high-pressure pump with the maximum flow rate of 120l/min at maximum pressure of 120bar. Both pumps in the pump unit assembly have individual electric motors, couplings and safety valves. Other main components are connected to the suction and high-pressure manifolds that are shown in the dimension drawing.

Dimensions and main components

Specifications

Materials (contact to water): Stainless Steel / Brass

Suction connection: DN80

Discharge connection: DN32

Maximum operating pressure: 120 bar

Maximum f low rate: 2x120 l/min

Jockey pump unit Frame Suction manifold

Electric motor Housing and coupling

High-pressure pump High-pressure manifold

(13)

TECHNICAL DATA SHEET Pump systems 00.00.2007

P

UMP

U

NIT

2

X

120 L/MIN

 A

UTOMATIC

Version 1 Page 2 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Safety valve: One per pump

Strainer / filt er: One per pump

Electric motor: 2x30kW (400V, 50Hz)

Weight: 1060kg

Part numbers and arrangement

The pump unit is available in two versions. The standard version has all pipe connections to the right side of the pump unit. The mirrored version has all pipe connections to the left side.

2x120 l/min Aut omati c, Standard (30100835) 2x120 l/min Aut omati c, Mirro red (30100857)

Descript ion Version Part number

2 x 120l/min Automatic Standard 30100835

2 x 120l/min Automatic Mirrored 30100857

Compatibility

Pump unit can be connected to the following tank, suction line / filling units and return line.(See technical data sheets of tank units in order to see the different layout possibilities with different tank and pump unit combinations)

2x120 l/min Aut omati c, Standard (30100835):

2x120 l/min Automatic, Mirrored (30100857):

Tank unit / Suction line Part Number Return line (optional) Compressor (optional)

500L, DN80 30000729Standard 30000716DN50  All suitable 1000L, DN80 Standard 30000735 DN50 30000716  All suitable 3000L, DN80 Standard 30000745 DN50 30000716  All suitable 4000L (On request) - -

-Tank unit / Suction line Part Number Return line (optional) Compressor (optional)

500L, DN80 Mirrored 30000732

DN50

30000716  All suitable 1000L, DN80 30000740Mirrored 30000716DN50  All suitable 3000L, DN80 30000750Mirrored 30000716DN50  All suitable

(14)

-TECHNICAL DATA SHEET Pump systems 13.04.2007

P

UMP

U

NIT

2

X

120 L/MIN

D

ELUGE

Version 1 Page 1 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

This 2x120 l/min pump unit is designed to be used in deluge systems. The pump unit is built modular and with reduced number of components. The pump type used is a triplex plunger high-pressure pump with the maximum flow rate of 120l/min at maximum pressure of 120bar. Both pumps in the pump unit as-sembly have individual electric motors, couplings and safety valves. Other main components are con-nected to the suction and high-pressure manifolds that are shown in the dimension drawing.

Dimensions and main components

Specifications

Materials (contact to water): Stainless Steel / Brass

Suction connection: DN80

Discharge connection: DN32

Maximum operating pressure: 120 bar

Maximum f low rate: 2x120 l/min

Safety valve: One per pump

Strainer / filt er: One per pump

Electric motor: 30kW (400V, 50Hz)

Weight: 1060kg

Frame Suction manifold

Electric motor Housing and coupling

High-pressure pump High-pressure manifold

(15)

TECHNICAL DATA SHEET Pump systems 13.04.2007

P

UMP

U

NIT

2

X

120 L/MIN

D

ELUGE

Version 1 Page 2 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Part numbers and arrangement

The pump unit is available in two versions. The standard version has all pipe connections to the right side of the pump unit. The mirrored version has all pipe connections to the left side.

2x120 l/min Deluge, Standard (30100856) 2x120 l/min Deluge, Mirro red (30100858)

Descript ion Version Part number 2 x 120l/min Deluge Standard 30100856 2 x 120l/min Deluge Mirrored 30100858

Compatibility

Pump unit can be connected to the following tank, suction line / filling units and return line. (See technical data sheets of tank units in order to see the different layout possibilities with different tank and pump unit combinations)

2x120 l/min Deluge, Standard (30100856):

2x120 l/min Delug e, Mirro red (30100858):

Tank unit / Suction line Pump unit Return line (optional) Compressor (optional) 500L, DN80 Standard 30000729 DN50 30000716  All suitable 1000L, DN80 Standard 30000735 DN50 30000716  All suitable 3000L, DN80 Standard 30000745 DN50 30000716  All suitable 4000L (On request) - -

-Tank unit / Suction line Pump unit Return line (optional) Compressor (optional) 500L, DN80 Mirrored 30000732 DN50 30000716  All suitable 1000L, DN80 Mirrored 30000740 DN50 30000716  All suitable 3000L, DN80 Mirrored 30000750 DN50 30000716  All suitable 4000L (On request) - -

(16)

-TECHNICAL DATA SHEET Pump systems 17.04.2007

C

OMPRESSOR

Version 1 Page 1 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

The compressor produces compressed air that is needed in pre-action and dry pipe systems for filling the pipes or using pneumatic operated valves in deluge systems. The compressor for all systems is the same, but there are two different mounting versions. The compressor with wall mounting kit can be used with all pump units. The compressor with pump unit mounting kit is available only with 2 and 3 x 120 l/min pump systems.

Types and Dimensions

Part numbers and Compatibility

Part number Type Compatibility

30100855 Standard compressor with wall

mounting kit  All pump units

30100834 Standard compressor with pump

mounting kit 2x120l/min Deluge (30100856, 30100858) 2x120l/min Automatic (30100835, 30100857) 3x120l/min Deluge (30100860, 30100862) 3x120l/min Automatic (30100859, 30100861) COMPRESSOR WITH WALL

MOUNTING KIT

COMPRESSOR WITH PUMP MOUNTING KIT

(17)

TECHNICAL DATA SHEET Pump systems 17.04.2007

C

OMPRESSOR

Version 1 Page 2 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification. © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Specifications

Pressure connection: ¼“ connection, equipped with quick

coupling for DN6 hose

Capacity: 150l/min @ 6bar

Maximum pressure 10bar

Volume of tank: 24 litres

(18)

TECHNICAL DATA SHEET Tank Unit 00.00.2007

1000 L

ITRE

T

 ANK

U

NIT

Version 1 Page 1 of 4

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

The 1000 litre tank unit can be used with all standard pump units. The tank unit can work as total volume storage or as break tank where water is supplied from a tank to the pumps. The tank is simultaneously filled with fresh water from an external water supply in brake tank arrangement. The main water supply must assure the minimum flow rate of the pump system within a pressure range of 1,5 to 6 bar to tank filling. Tanks should be placed generally close to the pump unit, but the tank pump orientation can be changed to different layouts.

The standard tank is made of black polyethylene*. The tank frame is galvanized carbon steel. The filling unit and suction line assemblies are part of the tank unit, but depended on the used pump configuration. The available suction line and filling unit assemblies are available in different sizes. The return line as-sembly can optionally be installed. The tank overflow is used to protect the tank against overfilling. The tank overflow should always be connected to water drain.

 A level measurement is mounted to the side wall of the tank. This level measurement optically indicates the water level in the tank. It also includes switches, giving opening signals via the PLC control to the tank filling valve as well as a minimum alarm if the water level in the tank reaches the lowest level.

Dimensions and main components**

* 1000 litre stainless steel tank unit is also available on request, please contact FOGTEC Fire Protection. ** Notice! Dimensions might change slightly depending on chosen filling unit and suction line assembly

Main filter Frame Overflow Return line Suction connection Filling valve

(19)

TECHNICAL DATA SHEET Tank Unit 00.00.2007

1000 L

ITRE

T

 ANK

U

NIT

Version 1 Page 2 of 4

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Specifications

Tank material: Polyethylene (black)

Suction lin e size: DN40, DN50, DN80, DN100 and DN125

Filling unit assemblies: DN25, DN40 and DN50

Overflow connection: DN80

Return l ine assembly (option al): DN25 and DN50

Filtration rate (water): 100µm (abs.)

Filtration r ate (air): 10 µm (abs.)

Versions

Pump unit is available in two versions, standard and mirrored. The standard version has always all pipe connections to the left side of the tank unit, which means that it can be connected to standard pump unit versions. The mirrored version means connections to the right side and only mirrored pump units. The main dimensions of standard and mirrored pump units are exactly same.

(20)

TECHNICAL DATA SHEET Tank Unit 00.00.2007

1000 L

ITRE

T

 ANK

U

NIT

Version 1 Page 3 of 4

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Possible layout arrangements

The connections between tank unit and pump units are flexible, which enables changing of the layout easily. The following drawing shows approximate areas where tank unit can be positioned. The drawing shows standard pump and tank units, but this can be mirrored with mirrored pump and tank units.

Possible tank unit installation area with standard supply components

There is minimum distance between tank and pump unit that varies depending on the pump unit configu-ration. The normal minimum distance is 1.5 metre. This can be reduced to 0.7 metre if the pump unit configurations of 1-2 times 50l/min pumps or 1 time 120l/min pump units are used.

Part n umbers and compatibility

The part numbers of different pump unit configurations are shown in the following table. The tank unit includes always the suction line and filling unit assembly. These have to be dimensioned according to pump unit configuration. All compatibilities between different pump units and 1000 litre tank unit are ex-plained in the table. The return line assembly is an optional selection with the different part number. Notice! 1x50l/min and 1x120l/min standard pump units can be used with both tank designs.

(21)

You're Reading a Preview

Unlock full access with a free trial.

(22)

TECHNICAL DATA SHEET Pump systems 16.04.2007

C

ONTROL

C

 ABINETS

F

OR

120

L

/

MIN

P

UMP

U

NITS

Version 1 Page 1 of 2

FOGTEC reserves the right to improve and revise the products and recommended system configurations without notification.  © FOGTEC Brandschutz GmbH & Co. KG ● Schanzenstr. 19A ● 51063 Köln ● Germany

[email protected] ● www.fogtec.com ● Tel.: +49-(0)-221 96 22 30

Description

The control cabinet controls and monitors all electrical components in the pump system according the FOGTEC software that is installed to the PLC. Control cabinet controls both tank unit and pump unit. The electrical connections to tank unit are standard independent which tank unit is used, but they differ de-pending on the pump concept. All pump units will have a different control cabinet dede-pending on the num-ber of pumps and used system type (deluge/automatic). Control cabinets are available with two possible mounting possibilities depending on the size. Smaller systems with 1 to 2 pumps use cabinets with wall mounting. Larger pump systems are built to self standing cabinets.

Notice! Control cabinets have different sizes depending on mounting method and number of controlled pumps.

 All control cabinets have several self-diagnostic functions and failures are detected automatically. Control cabinets have different programs for service runs. Pumps can also be manually operated and tested with push buttons on the door of control cabinet.

Specifications

Power supply: 400V 50Hz (L1,L2,L3,PEN-4 wires)

Power requir ement: 1x120 l/min = 30kW (main fuses 80A)

2x120 l/min = 60kW (main fuses 125A) 3x120 l/min = 90kW (main fuses 200A) 4x120 l/min = 120kW (main fuses 250A)

IP class: 54

Potential free contacts :  A. Common failure

B. System running

C. Start signal (only deluge systems)

Colour: RAL7035

(23)

You're Reading a Preview

Unlock full access with a free trial.

References

Related documents

Philips Semiconductors reserves the right to change the specification without notice, in order to improve the design and supply the best possible product... This data sheet

FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION, OR DESIGN. TO OBTAIN THE LATEST,

Meru Networks reserves the right to change, modify, transfer, or otherwise revise this publication

ARRIS reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such

Philips Semiconductors reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Data

LEDiL Oy reserves the right to undertake technical changes of its products without further notification which could lead to changes in the provided data. LEDiL Oy assumes no

LEDiL Oy reserves the right to undertake technical changes of its products without further notification which could lead to changes in the provided data. LEDiL Oy assumes no

This study aimed to find out the adaptation mechanism of jabon (Anthocephalus cadamba Roxb) seedlings to excessive lead level based on the tolerance index of growth performance