The Prevention and Control of

Electrostatic Discharge (ESD)

(AN-40-005)

An Introduction to ESD

We experience occurrences of static electricity everyday. For example, walking along a carpeted floor in a heated room during winter generates sufficient static electricity to give us a rather shocking experience when we touch the door knob. While this sudden discharge of static electricity does not result in any harm to the human body, it can be very damaging to electronic devices which are

sensitive to electrostatic discharge (ESD). It is possible for electronic devices to be damaged by ESD that is imperceptible to the human body. This document is intended to shed some light on the sources of ESD and provides guidelines on the prevention and control of ESD.

Object or process Material or activity _ Work surfaces Waxed, painted or plastic surfaces.

Floors Waxed, common vinyl tiles, sealed concrete

Clothes Common smocks, non-conductive shoes,

synthetic materials (e.g. nylon) Chairs Vinyl, fiber-glass, finished wood

Packaging Common plastic bags, foam, trays, tote boxes Assembly area Spray cleaners, heat guns, blowers,

plastic tools (e.g. solder suckers, brushes) cathode ray tubes.

What are the common sources of static electricity?

The following table shows a sample list of sources of static electricity.

What are typical examples of static charge inducing situations? Does humidity have any effect on the induced static charge?

The following table shows some typical situations. Please note that humidity has a significant effect on the induced charge. It is not recommended to have

relative humidity (RH) that is too low, say, below 30%. ESD control becomes especially challenging at low RH levels. A relative humidity between 40% to 60% is recommended for the typical assembly area.

Means of static generation RH 10-20% RH 65-90%

Walking across a carpet 35,000 V 1,500 V

Walking on a vinyl tile floor 12,000 V 250 V Vinyl envelopes for work instructions 7,000 V 600 V

(2)

When a statically-charged person or object touches an electrostatic discharge sensitive (ESDS) device, there is a possibility that the electrostatic charge could be drained through sensitive circuitry in the device. If the electrostatic discharge possesses sufficient energy, damage could occur in the device due to localized overheating. Generally, devices with finer geometries are more susceptible to damage from ESD. The modes in which ESD damage occurs are:

(a) Discharge to the device

(b) Discharge from the device

(c) Field-induced discharge.

What damage does ESD cause in an electronic device? There are basically two categories of damage from ESD:

(a) Catastrophic damage – the electronic device is rendered inoperable

immediately after the ESD event. A semiconductor junction or a connecting metallization could have been damaged by the electrostatic discharge.

(b) Latent damage – the electronic device appears to be working fine following the

ESD event. However, the sensitive circuitry has been damaged and could fail to operate properly at some time in the future.

What are the classifications of ESD sensitivity?

Electrostatic discharge sensitive (ESDS) parts are commonly characterized to three defined models:

• Human Body Model (HBM)

• Machine Model (MM)

• Charged Device Model (CDM)

Based on the models used, the ESDS parts can be classified in accordance with the following table (per MIL-STD-1686C, with HBM subgroups per ESD STM5.1-2001). It should be noted that the HBM, MM and CDM voltage levels do not correlate with each other.

ESD Model ESD Classification Voltage Range

Human Body Model (HBM) 0

1A 1B 1C 2 3A 3B 0V – 249V 250V – 499V 500V – 1999V 1000 – 1999V 2000 – 3999V 4000 – 7999V >= 8000V Machine Model (MM) M1 M2 M3 M4 M5 0V – 100V 101V – 200V 201V – 400V 401V – 800V >800V

Charged Device Model (CDM) C1

C2 C3 C4 C5 C6 C7 0V – 124V 125V – 249V 250V – 499V 500V – 999V 1,000V – 1,499V 1,500V – 2,999V >= 3,000V

(3)

Application Note

Detection of static charges in the work area.

A commonly used tool for the detection of static charges is the electrostatic field meter. This tool, when used in conjunction with regular audits on the production floor, is very effective in detecting the presence and magnitude of static

charges. Care should be exercised to ensure adherence to the measurement distance as the meter is calibrated to specific distances from the measuring plane. Please consult the user’s guide on the correct measuring distance for the specific electrostatic field meter model that is being used.

Protection for Electrostatic Discharge Sensitive (ESDS) devices. (A) Work area:

1. It is essential to handle ESDS devices at static-safe workstations. This will prevent yield loss (through catastrophic damage) or, worse,

potential reliability failures in the field (through latent damage).

2. Where it is impractical or impossible to use antistatic wrist-straps or remove items that are composed of insulative materials at a static-safe workstation, use an air ionizer designed to neutralize electrostatic charges or apply topical antistats to control generation and

accumulation of static charges.

3. When an air ionizer is utilized, it is vital that maintenance procedures and schedules are adhered to in order to ensure that ions generated by the ionizer are sufficiently balanced.

4. Avoid bringing sources of static electricity (as shown in page 1) within 1 meter of a static-safe work bench.

5. Where it is necessary to use air-guns, use special models that do not generate static charges in the air stream.

(B) Personnel:

1. Any accumulated charge on the body of the human operator should be discharged first before opening the protective container with ESDS devices inside. The discharge can be accomplished by putting a hand on a grounded surface or, ideally, by wearing a grounded antistatic wrist-strap.

2. The use of an antistatic smock for each worker is highly recommended.

3. Education and training on ESD preventive measures is invaluable.

4. A regular audit is also helpful in supporting an ESD program.

(C) Packaging and Transportation:

• ESDS devices should be contained in a static protective bag or container at all times during storage or transportation.

The Prevention and Control of Electrostatic Discharge (ESD)

(4)

Application Note

What materials are suitable for dissipating static electricity?

It is recommended that static dissipative materials are used as the medium (e.g. mats, containers) for discharging static charge to ground. These materials have the following properties:

Surface resistivity: 1 x 105 to 1 x 1012 ohms/sq

Volume resistivity: 1 x 104 to 1 x 1011 ohm-cm

Cautionary note: Materials which are conductive (e.g. stainless steel surfaces)

are not recommended for use as a static-safe work surface; the low electrical resistance could result in a transient-like (surge) discharge of static electricity. A rapid discharge is far more damaging to the electronic device than a gradually paced discharge through a static dissipative material.

Static-safe work bench.

The diagram below shows a typical static-safe work bench. The table top is covered by a static dissipative mat which is grounded through a 1 Meg-ohm resistor. This resistor is required in order to protect the users of the static-safe work bench – in the event that the ground becomes electrically live, the resistor will prevent electrical shock at the work bench. The same safety requirement holds true for the antistatic wrist-strap as well.

The Prevention and Control of Electrostatic Discharge (ESD)

Static dissipativetable top

ESD protective floor mat Ground

Point

Monitor Unit

ESD protective wrist strap

(5)

Application Note

An example of a static-safe work bench (at Electrical Test).

The picture below shows an example of a static-safe work bench. It is vitally important that the wrist-strap and the table mat are securely grounded (through the 1 Meg-ohm safety resistor). In addition, all other materials with which the products come into contact must also be static-safe. The use of an antistatic floor further enhances the protective capabilities of a static-safe work

environment. The worker should also wear an antistatic smock.

Antistatic finger cots Antistatic tweezers

Antistatic carrier tape Antistatic bag

Grounded wrist-strap Antistatic table mat Antistatic floor tiles

The Prevention and Control of Electrostatic Discharge (ESD)

(6)

An example of a Static Control Test Station.

The picture shows an example of a test station used to determine whether antistatic wrist-straps or antistatic shoes are working properly.

A green test indicator light means the wrist-strap is worn properly and is working as intended. This picture shows the configuration for testing wrist-straps. The test station can also be configured to test antistatic footwear.

Antistatic footwear.

Where a wrist-strap is impractical, e.g. the job requires the worker to walk from one location to another, it is recommended that antistatic footwear such as antistatic shoes or heel- straps are worn. The picture on the right shows an example of an antistatic heel-strap with the grounding cord running into the socks to make contact with the skin. It is also

necessary to use an antistatic floor

(e.g. conductive floor tiles) to work together with the antistatic footwear.

(7)

Application Note

References

ANSI/ESD S8.1-1993

“ESD Awareness Symbols” ANSI/ESD S20.20

“ESD Association Standard for the Development of an Electrostatic Discharge Control Program”

ESD STM5.1-2001

“Electrostatic Discharge Sensitivity Testing -- Human Body Model (HBM) Component Level”

MIL-HDBK-263

“Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (excluding electrically-initiated explosive devices)”

MIL-STD-1686C

“Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (excluding electrically-initiated explosive devices)”

JESD625-A

“Requirements for Handling Electrostatic-Discharge-Sensitive (ESDS) Devices.”

Labels to identify electrostatic discharge sensitive (ESDS) devices. The following labels are commonly used on containers and packaging to alert anyone who handles the ESDS devices on the need to use static-safe

procedures before handling the devices. The one on the left is preferred.

The Prevention and Control of Electrostatic Discharge (ESD)

The following verbiage should be placed beside the label: CAUTION

Contains parts and

assemblies susceptible to damage by Electrostatic Discharge (ESD)

(8)

IMPORTANT NOTICE © 2015 Mini-Circuits

This document is provided as an accommodation to Mini-Circuits customers in connection with Mini-Circuits parts only. In that regard, this document is for informational and guideline purposes only. Mini-Circuits assumes no responsibility for errors or omissions in this document or for any information contained herein.

Mini-Circuits may change this document or the Mini-Circuits parts referenced herein (collectively, the “Materials”) from time to time, without notice. Mini-Circuits makes no commitment to update or correct any of the Materials, and Mini-Circuits shall have no responsibility whatsoever on account of any updates or corrections to the Materials or Mini-Circuits’ failure to do so. Mini-Circuits customers are solely responsible for the products, systems, and applications in which Mini-Circuits parts are incorporated or used. In that regard, customers are responsible for consulting with their own engineers and other appropriate professionals who are familiar with the specific products and systems into which Mini-Circuits’ parts are to be incorporated or used so that the proper selection, installation/integration, use and safeguards are made. Accordingly, Mini- Circuits assumes no liability therefor.

In addition, your use of this document and the information contained herein is subject to Mini-Circuits’ standard terms of use, which are available at Mini-Circuits’ website at www.minicircuits.com/homepage/terms_of_use.html.

Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation d/b/a Mini-Circuits. All other third-party trademarks are the property of their respective owners. A reference to any third-party trademark does not constitute or imply any endorsement, affiliation, sponsorship, or recommendation: (i) by Mini-Circuits of such third-party’s products, services, processes, or other information; or (ii) by any such third-party of Mini-Circuits or its products, services, processes, or other information.

References

Related documents

Since the functors for stream systems and automata are polynomial, as a special case of Theorem 7.2 we obtain that a stream function, or a function on languages, is causal if and

This type of routing protocol maintains routing information from each node to every other node. Every node maintains one or more routing table to store routing information.

Although OLSR and OTRP reduce overheads by selecting which nodes can forward control packets, OTRP outperforms OLSR in high traffic load and dense network. Note although OLSR uses

(1) Single exposure: Color images with interpolated color quality, lower image resolution in all color channels. (2) Co-site sampling: Color quality comparable to a 3-chip CCD

The JAZ AP and SP with its solid back and simple Aluminum frame design along with the addition of the Harmony Backrest and the Stainless Steel electro-polished frame of the RAZ

Catalog Number Description where Used 001270BIF UltraLite Plus headband only UltraLite Plus 001290BIF UltraLite Sweatband only UltraLite Sweatband 001370LX UltraLite Pro headband

Other readings (not required): Pearson, Neil D., 2002, Risk Budgeting: Portfolio Problem Solving With Value-at-Risk (New York: John Wiley & Sons), Chapters 11, 12, and 13;

• Designed to withstand electrostatic discharge (ESD) of 15 kV to the optical port • Significantly reduces effect of electromagnetic interference (EMI) on receiver sensitivity •