JothanRive-ra -Re: SSD review for new Model No. 7054, CertificateoNo.ONR-668-D-11-EP From: To: Date: Subject: <Terrill.Gariand @ kidde-fenwal.com> "Jonathan Rivera" <[email protected]> 4/7/05 3:25PM

Re: SSD review for new Model No. 7054, Certificate No. NR-668-D-1 01 -E

Jonathan,

As we discussed earlier today, here is the information on the Instrument that was used for the dose rate measurements:

Model: S-1 371A Maker: OKEN

http:llwww,oken.co.jp/h/pdVeng/sms/s4.html

Please let me know If you need any additional Information on this equipment. And as soon as I receive the environmental conditions, I will forward them to you.

As we also discussed, please have both the Model CPD-7054 and CPD-7054D added to the NRC Reg. Certificate and Exempt Distribution license. This additional Model CPD-7054D will be identical to the CPD-7054, except for the production sensitivity range, which will need to be electronically adjusted to meet the UL duct detector requirements.

Thank you for your cooperation in this matter. If you have any questions conceming this subject, please contact me.

Regards, Terry Garland

Manager, D&A Project Development Kidde-Fenwal, Inc.

Tel: (508) 881-2000 Ext. 2364 Fax: (508) 231-2015

e-mail: Terrill.Garland @ kldde-fenwal.com

"Jonathan

Rivera" To:

<JXR4 @ nrc.gov <Terrill.Garland @ kldde-fenwal.com cc: "John Jankovich"

04/07/2005 <[email protected]>

08:34 AM Subject: Re: SSD review for new Model No. 7054, Certificate No. NR-668-D-101-E

(2)

UiTnathan Rivera- He: SSD review for new Model No. 7054, Certificate[]No.ONR-668-D-101-E Page 21

.... hnRvr R:SDrve o nwMdlN.75, etfctf~.NR68D10 EPq 2

Good morning Terry,

Thank you for the Information. We have reviewed your comments. At this time, the only piece of Information that we need to complete the review is that stated under Item No. 4 of the attachement to my email to you on 3/18/05 - environmental conditions during dose rate measurements and instrument used (including type, window thickness, and sensitivity). Thank you.

Jonathan Rivera

Materials Safety & Inspection Branch U.S. Nuclear Regulatory Commission Phone: (301) 415-5810

Email: [email protected]

>>> <[email protected]> 03/25/05 03:33PM >>> Jonathan,

Here is our response to the Issues we discussed. I have added our comments In red on the attached list. Please let me know if this resolves all of

the outstanding issues, except for the two pieces of Info. I am waiting for from our manufacturer In Japan.

(See attached file: New dwgs for Alternate Assy.PDF)(See attached file: NRC Ltr 5-13-02.PDF) (See attached file: Kidde-Fenwal,

Deficlencles&Clarifications-Response.doc) Regards,

Terry Garland

Manager, D&A Project Development Kidde-Fenwal, Inc.

Tel: (508) 881-2000 Ext. 2364 Fax: (508) 231-2015

e-mail: Terrill.Garland@ kidde-fenwal.com

'Jonathan

Rivera" To:

<[email protected] <[email protected] cc: "John Jankovich"

03/24/2005 <[email protected]>

11:55 AM Subject: Re: SSD review for new Model No. 7054, Certificate No. NR-668-D-101-E

(3)

FJ~na~than*Rivera

-

Re: SSD review for new Model No. 7054, CertificateoN&o.NR-668-D-101-E_

Paae:31

Good Morning Terry,

Would like to check up on the status of the issues that we discussed in our conference call on 3/22, and also make sure that you received my fax with the OECD/NEA 1977 standard for smoke detectors.

Thanks,

Jonathan Rivera

Materials Safety & Inspection Branch U.S. Nuclear Regulatory Commission Phone: (301) 415-5810

Email: [email protected]

This email has been scanned by the MessageLabs Email Security System. For more information please visit http:llwww.messagelabs.com/email

The Information contained in this message or any of its attachments may be privileged and confidential and Intended for the exclusive use of the

addressee. Any views or opinions expressed in this e-mail are those of the individual and not necessarily of Kidde plc. If you are not the Intended recipient, any disclosure, reproduction, distribution or other

dissemination or use of this communications Is strictly prohibited. If you have received this transmission in error, please contact the IT Help Desk on +44 (0) 1753 766380.

This email has been scanned by the MessageLabs Email Security System. For more Information please visit http:/Awww.messagelabs.com/emall

The Information contained in this message or any of Its attachments may be privileged and confidential and Intended for the exclusive use of the

addressee. Any views or opinions expressed in this e-mail are those of the individual and not necessarily of Kidde plc. If you are not the intended recipient, any disclosure, reproduction, distribution or other

dissemination or use of this communications is strictly prohibited. If you have received this transmission in error, please contact the IT Help Desk on +44 (0) 1753 766380.

(4)

Riverat

"'ir-iRh:7SSDreview for newModel No. 7054,CertificateOI4o.NR"~i-668-D-101-E -- page 4

(5)

I c-'ýiýri;;ýrWI00001.Tmp Page 11I

cAtemD\GW~OOOO1 .TMP Paae 1 N

Mail Envelope Properties

(42558922.959: 23 : 59737)

Subject:

Creation Date:

From:

Re: SSD review for new Model No. 7054, Certificate

668-D-101-E

4/7/05 3:27PM

<[email protected]>

No.

NR-Created By:

TerriII.Garland@kidde-fenwal~com

Recipients nrc.gov twf4_po.TWFN_DO JPJ2 CC (John Jankovich) JXR4 (Jonathan Rivera) Post Office twf4_po.TWFN_DO

Route

nrc.gov

Files

MESSAGE

Mime.822

Options

Expiration Date:

Priority:

Reply Requested:

Return Notification:

Concealed Subject:

Security:

Size

5572 6368

Date & Time

04/07/05 03:27PM

None

Standard

No

None

No

Standard

(6)

-Survey Meter for the Low Energy 1251 y-ray S-1371A Page I of 2

__e__erfohEn_

yreY

1 : If.T 8j 13

37

1 A 125

1 Description]

1251 is widely used in the fields of medicine and biology for synthesizing the labeled

compounds and for Radioimmunoassay.

The Model S-1 371A is a survey meter to be used in industries or laboratories dealing with

1251. This survey meter can detect, with very high sensitivity, contaminations Including surface contaminations by nuclides with low energy "-ray.

In contrast to conventional survey meters which have 0.1% of counting efficiency against

1251 the Model S-1 371A has 24% of efficiency (240 times sensitive) and can detect as low as 10-4p Ci.

Also, the detector has an extension probe support and can easily check and detect the floor contaminations.

I Features ]

1 The counting efficiency against 1251 is 24% and 240 times sensitive than a GM counter. 2 An extension probe support Is provided for checking the floor contamination.

3 The detector has directivity (low sensitivity for Incident beams with an angle) and can detect the floor contamination under a high background.

4 Two Unit 2 batteries are used as the power source. They are very easy to replace. 5 Other than 1251, this model can be used for measurements of low energy radiations such

as i -ray Bremsstrahlung radiation or X-ray.

6 As the logic output signal is provided, outputting of the integrated data to scaler or a personal computer Is available.

[[ Survey Meter Series]]

Dew-free type a-ray Survey Meter SZS-201 *Dew-free type A -ray Survey Meter SPS-201 Dew-free type -r-ray Survey Meter SND-201 *12SSurvey Meter for the Low Energy 1251 7"-ray

S-1371A

(7)

Survey Meter for the Low Energy 1251 y-ray S-1371A

Page 2 of 2

. Survey Meter for the Low Energy 1251 y-ray S-137jA Page 2 of 2°

References

Related documents

Make  changes  to  section  on  agreements  to   reflect  emphasis  of  agreements  in  new

Most companies recruit for full-time and internship positions, but some indicate Co-Op as a recruiting priority, while not attending Professional Practice

$1000 and a complimentary letter to Mary Patten for her heroic work in bringing the fast sailing clipper ship safely around the dangerous Cape Horn?. When Mary and Captain

In the previous sections, we dis- cuss the expectation that a neural network exploiting the fractional convolution should perform slightly worse than a pure binary (1-bit weights

Political Parties approved by CNE to stand in at least some constituencies PLD – Partido de Liberdade e Desenvolvimento – Party of Freedom and Development ECOLOGISTA – MT –

The Master Fund is authorised in Luxembourg as a specialised investment fund and is managed by a management company, Ress Capital Fund Management SA, who acts

Following the contrastive learning framework (Chen et al., 2020), we can train the model to learn the representations of the ground truth sentence by contrasting the positive pairs

2 Percentage endorsement rates for items from the DISCO PDA measure stratified by group ( “substantial” PDA features, “some” PDA features and the rest of the sample).. N