Security module CG2
User manual
This manual is furnished to help You understand Your security system and become proficient in its
operation. All users of Your security system should read and follow the instructions and precautions in
this booklet. Failure to do so could result in the security system not working properly.
This booklet should be kept in an accessible location for the life of the security system.
If You do not understand any part of this manual You should notify Your installing company and ask
for that section of the manual to be explained fully.
Fill the tables on pages 7 and 8.
Remember, read the entire manual and, if is possible practice on the keypad and mobile phone
control while Your professional installer is at Your building. If You have any questions ask Your
installing company.
Please keep in mind that the level of security You will obtain with this system relates specifically with
two major factors:
1. The quantity, quality, and placement of security devices attached to this system.
2. The knowledge You have of the security system and how that knowledge is utilized in a weekly
test of the complete system.
You should be aware of the following facts when preparing a safety/security plan for Your
home/business.
1. Your security system is an electronic device and is subject to failure or malfunction. Do not rely
on it as Your single source of security.
2. Your system should be tested weekly.
3. Your system will not work without power.
4. Warning devices will need to be loud enough, wired correctly, and properly placed to provide
notification of an alarm event.
5. Smoke and heat detectors may not detect heat and smoke in all situations.
6. Use qualified security professionals to select, install, and maintain Your security system.
7. It may be possible to arm the security system without the backup battery connected.
Your periodic test should be done with A.C. Power removed to verify the battery is connected and
adequately charged.
8. Care should be taken to plug in and properly restrain the A.C. Transformer after testing.
Please read this entire booklet carefully before operating Your security system. If You do not
understand any portion of this manual, or if You have any questions about Your system, contact the
installing company listed on page 8 of this booklet.
Main features
Security system can be armed/disarmed:
1. By free of charge phone call. Up to 40 User phone numbers can be entered into module’s
phonebook, by which security system can be armed/disarmed and/or change state of
PGM established to operate as DIAL remotely.
2. By changing the state of input established to function as control zone ON/OFF with
devices that have switching contacts (keypad SZW-02, Access board, switch and etc).
3. By Paradox
®keypad K636, MG10LEDV, MG10LEDH or MG32LED.
Security module sends messages:
-
SMS messages to two User telephones. User can be additionally informed about the
sending of SMS messages by a free of charge call.
and/or
Control of security system by using keypad
1. Changing [Master code]. This code is possible to change not delete.
+[Master code] Press the key. Enter the 4-digit password (default is 1234). Key starts flashing and key [1] shining.
[0]+[1] Enter the 2-digit rank number of Master code (default is [0]+[1]). [New Master code] Enter a new 4-digit Master code.
[New Master code] Repeat the entered Master code.
[ENTER] Press key [ENTER].
[CLEAR] Press key [CLEAR] to finish programming mode.
2. Entering a new [User code].
+[Master code]
Press the key. Enter the 4-digit password (default is 1234). Key starts flashing and key [1] shining. Other flashing buttons mean that corresponding User codes have already been entered.
[0]+[4] Enter the 2-digit rank number of User code (e.g. [0]+[4]). [New User code] Enter the new 4-digit User code
[New User code] Repeat the entered User code.
[ENTER] Press key [ENTER].
Other User codes are entered in a similar way, only changing the User’s rank number.
[CLEAR] Press key [CLEAR] to finish programming mode.
3. Deleting a [User code].
+[Master code]
Press the key. Enter the 4-digit Master code (default is 1234). ). Key starts flashing and key [1] shining. Other flashing buttons mean that corresponding User codes have already been entered.
[0]+[4] Enter the 2-digit rank number of User code (e.g. [0]+[4]) which You want to delete.
[SLEEP] Press key [SLEEP]. Sound signal will be heard and button showing corresponding User code will switch off. Code is deleted.
Other User codes are deleted in a similar way, only changing the User’s rank number.
[CLEAR] Press key [CLEAR] to finish programming mode.
4. Press key [CLEAR] to finish programming mode, delete or modify wrong command.
5. Arming security system.
Close all zones in desired partition (e.g. close windows, doors).
If zones are disturbed, security system will not arm.
Zones are in desired partition when keys [1], ..., [6] are switched off.
[User code]
Enter Your 4-digit User code. The system starts calculating exit delay time, during which indicator ARM is flashing. Open external door. When system is armed indicator ARM is shining.
If Bell squawk function is turned on, siren will squawk once upon arming. Leave the premises and
close external door.
How much time You have to leave premises see value written in row “Exit delay time” on page 8.
6. Disarming security system.
Enter in Your premises The system starts calculating entry delay time.
[User code]
How much time You have to enter 4-digit User code see value written in row “Entry delay time” on page 8.
Indicator OFF is shining when system disarms.
If Bell squawk function is turned on, siren will squawk twice upon disarming.
7. Arming security system in STAY. I way (when entering the premises, entry delay time
countdown will start).
Close all zones in desired partition (e.g. close windows, doors).
If zones are disturbed, security system will not arm.
Emergency alarms
Security system arming/disarming by changing a state of zone named ON/OFF
Ask Your installer what is way to arm/disarm security system by devices having switching contacts
(keypad SZW-02, keyswitch TM1 etc).
Arming/Disarming security system by free of charge call.
Modules phonebook stows up to 40 phone numbers of Users who can remotely arm/disarm security
system by free of charge call.
8. Arming security system in STAY. II way (entry to premises is impossible without security
system alarm).
Close all zones in desired partition (e.g. close windows, doors).
If zones are disturbed, security system will not arm.
Zones are in desired partition when keys [1], ..., [6] are switched off.
[STAY] Press key [STAY]
[User code]
Enter Your 4-digit User code. Open the door and leave the premises. System arms in STAY mode. During STAY arming indicator ARM is shining, STAY is flashing.
Enter Your 4-digit User code to disarm system
9. Turning a siren OFF.
[User code] Enter Your 4-digit User code to turn siren off.
10. Bypassing a zone.
[BYP] Press key [BYP].
[User code] Enter Your 4-digit User code. Key [BYP] will start flashing.
[0]+[2]
Enter a 2-digit number of a zone You want to bypass (e.g. [0]+[2]). If it is necessary to bypass more zones, enter all numbers of zones You want to bypass (e.g. [0]+[2]+[0]+[3]).
[ENTER] Enter key [ENTER]. Key [BYP] and buttons of bypassed zones numbers will start shining. Zones are bypassed only for one arming.
Arm security system System is ready to be armed. Follow the arming schedule written in 5, 6, 7 chapters.
1. PANIC signal to send message “call the police”.
[1]+[3] Press buttons [1]+[3] and hold for at least 2 seconds to generate alarm signal (e.g. siren or bell) and transfer panic message.
2. PANIC signal to inform send message “call the medic”.
[4]+[6] Press buttons [4]+[6] and hold for at least 2 seconds to generate medical alarm signal (e.g. siren or bell) and transfer panic message.
3. FIRE signal to inform about fire.
[7]+[9] Press buttons [7]+[9] and hold for at least 2 seconds to generate fire alarm signal (e.g. siren or bell) and transfer fire alarm message.
1. Arming security system by free of charge call.
Leave Your premises.Don’t forget to close all zones in desired partition (e.g. close windows, doors).
If zones are disturbed, security system will not arm.
[call to module]
Being outside call to module by telephone number of its SIM card. Module will reject Your call when it arms the security system.
If Bell squawk function is turned on, siren will squawk once upon arming. Module sends confirmations of command execution.
2. Disarming security system by free of charge call.
[call to module]
Being near Your premises call to module by telephone number of its SIM card. Module will reject Your call when it disarms the security system.
Keypad K636
Keys [1], ..., [6] are shining – zones are disturbed.
Key [ARM]:
- Is shining. Security system is armed.
- Is flashing. Is calculating exit delay.
Key [STAY]:
- It’s shining together with the key [ARM]. System is armed in STAY mode (fully armed
premises perimeter but is allowed to freely roam inside). It’s possible to disarm the
security system through an entry delay.
- Is flashing. Security system is disarmed while staying inside.
Key [OFF] is shining. Security system is disarmed.
Power supply key [~]:
- Is shining. Control panel is powered from AC main.
- Is flashing – Is powered from the backup battery.
- Turned off. No power supply.
Key
is shining. User code programming mode.
Keys [1], ..., [9] are shining. Number of codes are shining are entered.
Key [TBL] is shining. Not communicate keypad to control panel.
Electrical engineering remote control
Ask Your installer what is way to control connected electrical engineering devices (EED)
remotely. If EED is controlled by phone call, ring to module by SIM card number. If EED is
controlled by SMS, send an SMS by SIM card number. SMS structure:
Task
SMS text
Change 4
thoutput state to [1].
PSW123456_54_1
Change 4
thoutput state to [0].
PSW123456_54_0
Reverse 4
thoutput state.
PSW123456_50_4
Remote configuration and requests
Task
SMS text
Change the password
PSW123456_98_654321
Install phone number of User who will arm/disarm the
security system.
PSW654321_03_37012312345#
Install phone number of first User who will receive
information sent by security system.
PSW654321_04_37012312345#
Install phone number of second User who will receive
information sent by security system.
PSW654321_05_37012354321#
Activate GSM communicator to transfer SMS messages
to users above.
PSW654321_09_00001100
Request about outputs state*
PSW123456_97_3
Request about arming of security system, power supply* PSW123456_97_4
Request about GSM level and IMEI*
PSW123456_97_5
*Module will replay to sender’s telephone.
If the primary (default) password is not changed, module's user list can be manipulated.
This means, that one can enter his telephone number to control the security system
without an assent from the owner.
In SMS examples:
PSW – initial command,
6 digits password (default – 123456).
underscore „_” means space in SMS text,
03, 04, 05, 09, 50, 54, 00001100 – commands codes,
37012312345 – International telephone number (without +, up to 16 digits),
# - end symbol of the telephone number (required in the text).
For info
Status event report Enable
Periodical test
GSM level
Open
Close
System Reset
Remote Open
Remote Close
Armed STAY
Medical
Fire
Panic
Output ID Output Definition
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
Zone ID Alarm message Restore message ZoneBYPASS Zone Definition Input TYPE