• No results found

Security module CG2 User manual

N/A
N/A
Protected

Academic year: 2021

Share "Security module CG2 User manual"

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

(1)

Security module CG2

User manual

(2)

This manual is furnished to help You understand Your security system and become proficient in its

operation. All users of Your security system should read and follow the instructions and precautions in

this booklet. Failure to do so could result in the security system not working properly.

This booklet should be kept in an accessible location for the life of the security system.

If You do not understand any part of this manual You should notify Your installing company and ask

for that section of the manual to be explained fully.

Fill the tables on pages 7 and 8.

Remember, read the entire manual and, if is possible practice on the keypad and mobile phone

control while Your professional installer is at Your building. If You have any questions ask Your

installing company.

Please keep in mind that the level of security You will obtain with this system relates specifically with

two major factors:

1. The quantity, quality, and placement of security devices attached to this system.

2. The knowledge You have of the security system and how that knowledge is utilized in a weekly

test of the complete system.

You should be aware of the following facts when preparing a safety/security plan for Your

home/business.

1. Your security system is an electronic device and is subject to failure or malfunction. Do not rely

on it as Your single source of security.

2. Your system should be tested weekly.

3. Your system will not work without power.

4. Warning devices will need to be loud enough, wired correctly, and properly placed to provide

notification of an alarm event.

5. Smoke and heat detectors may not detect heat and smoke in all situations.

6. Use qualified security professionals to select, install, and maintain Your security system.

7. It may be possible to arm the security system without the backup battery connected.

Your periodic test should be done with A.C. Power removed to verify the battery is connected and

adequately charged.

8. Care should be taken to plug in and properly restrain the A.C. Transformer after testing.

Please read this entire booklet carefully before operating Your security system. If You do not

understand any portion of this manual, or if You have any questions about Your system, contact the

installing company listed on page 8 of this booklet.

Main features

Security system can be armed/disarmed:

1. By free of charge phone call. Up to 40 User phone numbers can be entered into module’s

phonebook, by which security system can be armed/disarmed and/or change state of

PGM established to operate as DIAL remotely.

2. By changing the state of input established to function as control zone ON/OFF with

devices that have switching contacts (keypad SZW-02, Access board, switch and etc).

3. By Paradox

®

keypad K636, MG10LEDV, MG10LEDH or MG32LED.

Security module sends messages:

-

SMS messages to two User telephones. User can be additionally informed about the

sending of SMS messages by a free of charge call.

and/or

(3)

Control of security system by using keypad

1. Changing [Master code]. This code is possible to change not delete.

+[Master code] Press the key. Enter the 4-digit password (default is 1234). Key starts flashing and key [1] shining.

[0]+[1] Enter the 2-digit rank number of Master code (default is [0]+[1]). [New Master code] Enter a new 4-digit Master code.

[New Master code] Repeat the entered Master code.

[ENTER] Press key [ENTER].

[CLEAR] Press key [CLEAR] to finish programming mode.

2. Entering a new [User code].

+[Master code]

Press the key. Enter the 4-digit password (default is 1234). Key starts flashing and key [1] shining. Other flashing buttons mean that corresponding User codes have already been entered.

[0]+[4] Enter the 2-digit rank number of User code (e.g. [0]+[4]). [New User code] Enter the new 4-digit User code

[New User code] Repeat the entered User code.

[ENTER] Press key [ENTER].

Other User codes are entered in a similar way, only changing the User’s rank number.

[CLEAR] Press key [CLEAR] to finish programming mode.

3. Deleting a [User code].

+[Master code]

Press the key. Enter the 4-digit Master code (default is 1234). ). Key starts flashing and key [1] shining. Other flashing buttons mean that corresponding User codes have already been entered.

[0]+[4] Enter the 2-digit rank number of User code (e.g. [0]+[4]) which You want to delete.

[SLEEP] Press key [SLEEP]. Sound signal will be heard and button showing corresponding User code will switch off. Code is deleted.

Other User codes are deleted in a similar way, only changing the User’s rank number.

[CLEAR] Press key [CLEAR] to finish programming mode.

4. Press key [CLEAR] to finish programming mode, delete or modify wrong command.

5. Arming security system.

Close all zones in desired partition (e.g. close windows, doors).

If zones are disturbed, security system will not arm.

Zones are in desired partition when keys [1], ..., [6] are switched off.

[User code]

Enter Your 4-digit User code. The system starts calculating exit delay time, during which indicator ARM is flashing. Open external door. When system is armed indicator ARM is shining.

If Bell squawk function is turned on, siren will squawk once upon arming. Leave the premises and

close external door.

How much time You have to leave premises see value written in row “Exit delay time” on page 8.

6. Disarming security system.

Enter in Your premises The system starts calculating entry delay time.

[User code]

How much time You have to enter 4-digit User code see value written in row “Entry delay time” on page 8.

Indicator OFF is shining when system disarms.

If Bell squawk function is turned on, siren will squawk twice upon disarming.

7. Arming security system in STAY. I way (when entering the premises, entry delay time

countdown will start).

Close all zones in desired partition (e.g. close windows, doors).

If zones are disturbed, security system will not arm.

(4)

Emergency alarms

Security system arming/disarming by changing a state of zone named ON/OFF

Ask Your installer what is way to arm/disarm security system by devices having switching contacts

(keypad SZW-02, keyswitch TM1 etc).

Arming/Disarming security system by free of charge call.

Modules phonebook stows up to 40 phone numbers of Users who can remotely arm/disarm security

system by free of charge call.

8. Arming security system in STAY. II way (entry to premises is impossible without security

system alarm).

Close all zones in desired partition (e.g. close windows, doors).

If zones are disturbed, security system will not arm.

Zones are in desired partition when keys [1], ..., [6] are switched off.

[STAY] Press key [STAY]

[User code]

Enter Your 4-digit User code. Open the door and leave the premises. System arms in STAY mode. During STAY arming indicator ARM is shining, STAY is flashing.

Enter Your 4-digit User code to disarm system

9. Turning a siren OFF.

[User code] Enter Your 4-digit User code to turn siren off.

10. Bypassing a zone.

[BYP] Press key [BYP].

[User code] Enter Your 4-digit User code. Key [BYP] will start flashing.

[0]+[2]

Enter a 2-digit number of a zone You want to bypass (e.g. [0]+[2]). If it is necessary to bypass more zones, enter all numbers of zones You want to bypass (e.g. [0]+[2]+[0]+[3]).

[ENTER] Enter key [ENTER]. Key [BYP] and buttons of bypassed zones numbers will start shining. Zones are bypassed only for one arming.

Arm security system System is ready to be armed. Follow the arming schedule written in 5, 6, 7 chapters.

1. PANIC signal to send message “call the police”.

[1]+[3] Press buttons [1]+[3] and hold for at least 2 seconds to generate alarm signal (e.g. siren or bell) and transfer panic message.

2. PANIC signal to inform send message “call the medic”.

[4]+[6] Press buttons [4]+[6] and hold for at least 2 seconds to generate medical alarm signal (e.g. siren or bell) and transfer panic message.

3. FIRE signal to inform about fire.

[7]+[9] Press buttons [7]+[9] and hold for at least 2 seconds to generate fire alarm signal (e.g. siren or bell) and transfer fire alarm message.

1. Arming security system by free of charge call.

Leave Your premises.

Don’t forget to close all zones in desired partition (e.g. close windows, doors).

If zones are disturbed, security system will not arm.

[call to module]

Being outside call to module by telephone number of its SIM card. Module will reject Your call when it arms the security system.

If Bell squawk function is turned on, siren will squawk once upon arming. Module sends confirmations of command execution.

2. Disarming security system by free of charge call.

[call to module]

Being near Your premises call to module by telephone number of its SIM card. Module will reject Your call when it disarms the security system.

(5)

Keypad K636

Keys [1], ..., [6] are shining – zones are disturbed.

Key [ARM]:

- Is shining. Security system is armed.

- Is flashing. Is calculating exit delay.

Key [STAY]:

- It’s shining together with the key [ARM]. System is armed in STAY mode (fully armed

premises perimeter but is allowed to freely roam inside). It’s possible to disarm the

security system through an entry delay.

- Is flashing. Security system is disarmed while staying inside.

Key [OFF] is shining. Security system is disarmed.

Power supply key [~]:

- Is shining. Control panel is powered from AC main.

- Is flashing – Is powered from the backup battery.

- Turned off. No power supply.

Key

is shining. User code programming mode.

Keys [1], ..., [9] are shining. Number of codes are shining are entered.

Key [TBL] is shining. Not communicate keypad to control panel.

(6)

Electrical engineering remote control

Ask Your installer what is way to control connected electrical engineering devices (EED)

remotely. If EED is controlled by phone call, ring to module by SIM card number. If EED is

controlled by SMS, send an SMS by SIM card number. SMS structure:

Task

SMS text

Change 4

th

output state to [1].

PSW123456_54_1

Change 4

th

output state to [0].

PSW123456_54_0

Reverse 4

th

output state.

PSW123456_50_4

Remote configuration and requests

Task

SMS text

Change the password

PSW123456_98_654321

Install phone number of User who will arm/disarm the

security system.

PSW654321_03_37012312345#

Install phone number of first User who will receive

information sent by security system.

PSW654321_04_37012312345#

Install phone number of second User who will receive

information sent by security system.

PSW654321_05_37012354321#

Activate GSM communicator to transfer SMS messages

to users above.

PSW654321_09_00001100

Request about outputs state*

PSW123456_97_3

Request about arming of security system, power supply* PSW123456_97_4

Request about GSM level and IMEI*

PSW123456_97_5

*Module will replay to sender’s telephone.

If the primary (default) password is not changed, module's user list can be manipulated.

This means, that one can enter his telephone number to control the security system

without an assent from the owner.

In SMS examples:

PSW – initial command,

6 digits password (default – 123456).

underscore „_” means space in SMS text,

03, 04, 05, 09, 50, 54, 00001100 – commands codes,

37012312345 – International telephone number (without +, up to 16 digits),

# - end symbol of the telephone number (required in the text).

(7)

For info

Status event report Enable

Periodical test

GSM level

Open

Close

System Reset

Remote Open

Remote Close

Armed STAY

Medical

Fire

Panic

Output ID Output Definition

OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

Zone ID Alarm message Restore message Zone

BYPASS Zone Definition Input TYPE

(8)

Installing company

Phones

Service company

Phones

For service call

Account Number

Entry delay time

Exit delay time

Time of siren operation

Periodicity of Test

Operation mode of control zone ON/OFF

Auto ARM

Phone number 1 of User who receives SMS

messages (SMS to USER1)

Phone number 2 of User who receives SMS

messages (SMS to USER2)

Phone number 1 of User who will be informed

about alarm by a call (DIAL to USER1)

References

Related documents

Using the Label Dispenser Open Door Switch On the Label Taken Sensor Remove Several Labels Push Liner Through Slot Close Door Close Top Cover and Press Feed Button MOVIE.1.

When you enter your security code to arm the system, or press the "Stay" button on the keypad, and do not exit the premises through a designated Exit/Entry door, the system

If you arm your system, exit, and accidentally leave the door open, then when the exit delay time expires, the police alarm will sound and the central monitoring station will

• Patented Key Light display (button illuminates to indicate an open zone) • Arm, Sleep, Stay and Off keys illuminate to indicate partition status • Adjustable backlight. •

Windows Doors & Arm Sensors Motion Arm Status System Bypass Time Lights Sensor Lights Off Lights On Lights + Access Code Disarm Motion Sensors Arm Sensors

This parameter stores the maximum time period to wait door lock closed after a door close signal is sent.. The data is displayed

The Geometry API provides methods to access geometry objects like doors, rooms, and measurement regions.. In addition, methods are provided to open and