GABLE SIDING, GABLE VENT TO BE
INSTALLED AT SITE BY OTHERS.
*
FRONT ELEVATION
REAR ELEVATION
LEFT ELEVATION
RIGHT ELEVATION
BY OTHERS AT SITE.
FIELD NOTES
* INDICATES ITEMS INSTALLED
2020 MODEL:
DATE: DRAWN BY: REVISION BOX
WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406
CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
ELEVATIONS
PULSE PRODUCT
MDKUTILITY
32
32
24
OPT
F
24
GFILIVING ROOM
BEDROOM 2
KITCHEN
DINING
MASTER BEDROOM
11'-4"
11'-4"
BATH #2
BEDROOM 3
FAMILY ROOM
22'-8"
56'-0"
SHEAR WALL "A" SHEAR WALL "B"
LAUN. SHELF
W
D
3660E
3660
3660
3660
3660E
3660E
3660
3660
3242
13'-8"
CLEARSPAN
42
60
71 WS
71 WS
60
MASTER
BATH
ES
W/HRAG
61 1/2 WS
(4)-46 1/4 PS
PANTRY
DESK
OPTIONAL
STORAGE BENCH
3'-11"
CLEARSPAN
32
24
32
24
32
24
OPT
10'-2"
5'-0"
9'-1"
16'-4 3/4"
4 1/4
3 7/8
3 1/4
3 1/4
3 7/8
10'-5 7/8"
15'-10 1/8"
25'-2 3/8"
41'-10 3/8"
13'-6 1/2"
3 1/4
14'-11 3/4"
10'-5 1/2"
16'-1 1/4"
3 7/8
3 7/8
15'-3 5/8"
25'-9 1/8"
41'-10 3/8"
13'-6 1/2"
3 1/4
DWR
OPT DW
36x80
36x80
OPT IS-2.0
30x51 ISLAND
27'-658" OPT DOMER C.L.
11'-4
5 8"
15'-3
5 8"
25'-9
3 4"
39'-5
3 4"
43'-8
1 8"
45'-10
1 8"
49'-10
1 8"
52'-8
1 8"
FURN
2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
FLOOR PLAN
PULSE PRODUCT
MDK736RE
2/8/2017UTILITY
LIVING ROOM
BEDROOM 2
KITCHEN
DINING
MASTER BEDROOM
BATH #2
BEDROOM 3
FAMILY ROOM
5" x 14" x 48'-6" HEAT DUCT
40'-8"
10'-1
1 2"
11'-2
1 4"
24'-10"
26'-2"
41'-6"
42'-6"
77
1 2
43'-4"
66
LAUN. SHELF
W
D
50'-0"
65
5" x 14" x 42'-0" HEAT DUCT
6'-2"
MASTER
BATH
95
7 8
PANTRY
DESK
79" X-OVER
49 1 8" X-OVER79" X-OVER
49 1 8" X-OVER 16x8 HIGH 16x8 LOW 16x8 HIGH 16x8 LOWNOTES:
1. ALUMINUM HEAT DUCTS
2. IN-FLOOR ALUMINUM X-OVER DUCTS
3. 4x10 REGISTERS
4. INLINE REGISTER STANDARD
5. 6" BRANCH DUCTS
39'-5"
68
24'-8"
12'-8"
3'-4"
5
5
5
8
8
8
51'-4"
2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
HVAC LAYOUT
PULSE PRODUCT
MDKUTILITY
5 GFI WP HTR ES 5 WP 4 WP 13 12 2 2 GFI T 8 GFI 1LIVING ROOM
BEDROOM 2
KITCHEN
DINING
MASTER BEDROOM
BATH #2
BEDROOM 3
FAMILY ROOM
LAUN. SHELF W D 4 4 4 6 6 5 8 16 4 OPT 8 GFI 4 5 5 5 5 5 6 6 6 6 6 6 6 6 4 4 4 2 4 6 5 1 GFI 2 GFI 1 GFI 1 GFI 5 W 14 15 10 11F 4 PV 19 OPT 1 GFI opt 2MASTER
BATH
5 6 PANTRY DESK 9 SD 9 SD 9 SD 9 SD 9 SD 4 4 4 4 opt opt 5 4 C 4 C 4C 4 C W/OPT ISLAND C P 3 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
ELECTRICAL LAYOUT
PULSE PRODUCT
MDKMAIN DRAIN LAV 1 1 2" P-TRAP WASHER 1 1/2" STAND PIPE K/S 1 1/2" P-TRAP STOOL STOOL LAV 1 1 2" P-TRAP VTR TUB 1 1 2" P-TRAP 1 1 2" 1 1 2" 1 2"1 45° ELL 1 1 2" 1 1 2" 8 1 1 2" 1 1 2" DBL WYE W/C.O. 1 1 2" 2" 3" 3" 3" DBL LTTY XLTL SANTEE DBL SANTEE 3 LTTY 1 2 3 4 5 6 WYE 7 DBL ELL 9 1 1 1 1 1 4 4 4 4 5 4 4 5 6 CO 6 CO 6 CO 45 5/8" 38" 56" 26" 44 1/8" 10" 41"
1
3" SANTEE
3" PIPE
3" C/O W/PLUG
20'
1
QUANTITY
SHIP LOOSE
3" LTTY
DESCRIPTION
1
NOTE:1. ALL PIPE AND FITTINGS ARE ABS SCHEDULE 40.
2. ASSEMBLY OF PIPE AND FITTINGS PER CONTAINER OF GLUE AND SOLVENT.
3. MATERIAL, PIPE, AND FITTINGS BY MANUFACTURE.
4. PIPING TO BE SUPPORTED AT 4'-0" AND 1/4" PER FOOT SLOPE MAINTAINED.
5. CUT PIPE TO LENGTH, COUPLERS ARE PROVIDED.
6. DASHED LINES INDICATE FIELD INSTALLED PIPE.
7. A COPY OF THIS LAYOUT TO ACCOMPANY UNIT AS PART OF THE INSTALLATION INSTRUCTIONS.
4 3" VTR TUB 1 1 2" P-TRAP 1 1 2" 2" 1 1 3" 21" 3 4 2" 13'-2"3" 2" 13" 3 6 3" 3 3/8" 3 13-10 7/8" 3 3" 3" 3" 3" C.O. 2" 2" 1 1 2" 80 5/8" 3" 126" 74" 4 4 28" 3" 4 5 3 12" 1 12" 1 1 2" 6 3/8" 4
3" COUPLING
1
53"
AUTO VENT OPT GAS FURNACE 5 5 3 107" 19" 14" 1 1 2" 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
PLUMBING DWV LAYOUT
PULSE PRODUCT
MDKWASHER STOOL TUB D/W KITCHEN SINK
X-OVER
SHUT-OFF VALVE
STOOLCOLD
HOT
W/H 3/4" INLET TUB LAV LAV 3/4" 3/4" 3/4" 3/4" 3/4"NOTES:
1. ALL PIPING IS TUFF-PEX
2. ALL FITTINGS ARE LISTED FOR USE WITH TUFF-PEX
3. ALL LINES 1/2" UNLESS OTHERWISE SPECIFIED
4. MAIN SHUT-OFF INSTALLED AT INLET. ALL OTHER SHUT-OFFS ARE OPTIONAL.
5. WATER HEATER TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS.
3/4" OPT. ICE OPT 3/4" 3/4" FAUCET 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406
CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
PLUMBING SUPPLY LAYOUT
PULSE PRODUCT
MDK3/4" INLET
DRYER
FURNACE
RANGE
40,000 BTUH
54,000 BTUH
30,000 BTUH
3/4"
W/H
42,000 BTUH
3/4"
2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.
PLUMBING GAS LINE LAYOUT
PULSE PRODUCT
MDK18 1 4 99 1 2 18 1 4 WATER ELECTRIC GAS 2'-0" 2'-0" 56'-0" 22'-8" 10 71 18 1 4 99 1 2 18 1 4 63 DWV DWV 49 25'-934" 39'-534" 42'-8" 29'-6" 46'-2" 51'-45 8" 29'-6"
1. THIS PRINT IS PROVIDED TO SHOW THE REQUIRED PIER LOCATION THAT ARE NOT MODIFIED BY THE SITE SOIL CLASSIFICATIONS
2. REFERENCE THE CLAYTON HOMES HUD INSTALLATION MANUAL FOR ALL LAYOUT AND DESIGN INFORMATION
3. THIS STRUCTURE HAS NOT BEEN DESIGNED TO BE LOCATED WITHIN FLOOD HAZARD LOCATIONS, WHEN SITE IS LOCATED, AUTHORITY HAVING
JURISDICTION OR FLOOD HAZARD MAPS, THE UNIT SHALL HAVE LOWEST FLOOR ELEVATED ABOVE THE DESIGNED FLOOD ELEVATION
4. THE DESIGN WIDTH IS NOMINAL AND DOES NOT TAKE INTO ACCOUNT THE OSB, SIDING, OR GAPS IN THE MATELINE AREA. A SITE INSTALLER
SHOULD CONFIRM ALL MEASUREMENTS WITH THE FINISHED STRUCTURE.
5. PERMITER BLOCKING SHOWN MAY BE OMITTED DUE TO ADDITIONAL FLOOR JOISTS PER THE SET UP MANUAL ADDENDUM SU-ADD-177.0.
1.
Wind Speed: Wind Zone 1
2. Maximum Roof Load: 30psf
3. Seismic Design Category: C
4. Max Sidewall Overhang: 12"
Perimeter blocking not Required
1. DESIGNED FOR ________ PSF ALLOWABLE SOIL IN ACCORDANCE WITH (PAGE 17 & 18) [3285.202] 2. FROST DEPTH IS _______ INCHES PER (FIGURE 5A) OR FROM LAHJ.
3. FROST PROTECTION WILL BE PROVIDED BY (Check one) : ___NA ; ___PLACING FOOTERS BELOW GRADE ; ___FROST PROTECTED DESIGN PAGE ________ ; ___FROST FREE DESIGN PAGE ___________ [3285.312(b)] 4. SPACE FRAME PIERS AT 2' FROM EACH END AND ____FT.-_____ INCHES ON CENTER BETWEEN.
5. LOAD AT EACH FRAME PIER WILL BE ________LBS. PER (TABLE 6__) without perimeter blocking OR (TABLE 7__ ) with perimeter blocking AT SPACING ABOVE.
6. SINGLE or DOUBLE (circle one) DRY or MORTARED(circle one) STACK CONCRETE BLOCKS WILL BE USED FOR ALL FRAME PIERS WHICH HAS CAPACITY OF _______ LBS PER MAX. & PIER HEIGHT IS __________ INCHES OR LESS (TABLE 9) (PAGE 31) [3285.306] 7. FRAME PIER FOOTING AREA WILL BE _______SQ. INCHES WHICH WILL BE ______INCHES (SQUARE OR DIAMETER) (circle one) (TABLE 10)
8. FOOTERS WILL BE POURED/ PRECAST/ OTHER:___________ (circle one or fill in) WITH MINIMUM DEPTH OF _______ INCHES (TABLE 10A)
9. LOAD AT SIDEWALL OPENINGS IS ________LBS. (TABLE 6d). FOOTING AREA WILL BE _______SQ. INCHES WHICH WILL BE ______INCHES (SQUARE OR DIAMETER) (circle one) (TABLE 10)
10. MATING WALL COLUMN PIERS: SPAN: ______FT.; LOAD:______LBS.; FOOTER SIZE: ______INCHES (SQUARE OR DIAMETER) (circle one); PIER CONF: ________ STACKED; (PER TABLE 5__; TABLE 10;TABLE 9)
(Reference to Clayton Homes DAPIA approved Installation manual) [Reference to Federal Statutes 24 CFR Part 3280, 3285 or 3286]
52'-0" (SEE CLAYTON INSTALLTION MANUAL FOR PIER / FOOTER LAYOUT & DESIGN INFORMATION)
2020 MODEL:
DATE: DRAWN BY: REVISION BOX
WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406
CLAYTON WAKARUSA
Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.