• No results found

PULSE PRODUCT ELEVATIONS

N/A
N/A
Protected

Academic year: 2021

Share "PULSE PRODUCT ELEVATIONS"

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

(1)

GABLE SIDING, GABLE VENT TO BE

INSTALLED AT SITE BY OTHERS.

*

FRONT ELEVATION

REAR ELEVATION

LEFT ELEVATION

RIGHT ELEVATION

BY OTHERS AT SITE.

FIELD NOTES

* INDICATES ITEMS INSTALLED

2020 MODEL:

DATE: DRAWN BY: REVISION BOX

WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

ELEVATIONS

PULSE PRODUCT

MDK

(2)

UTILITY

32

32

24

OPT

F

24

GFI

LIVING ROOM

BEDROOM 2

KITCHEN

DINING

MASTER BEDROOM

11'-4"

11'-4"

BATH #2

BEDROOM 3

FAMILY ROOM

22'-8"

56'-0"

SHEAR WALL "A" SHEAR WALL "B"

LAUN. SHELF

W

D

3660E

3660

3660

3660

3660E

3660E

3660

3660

3242

13'-8"

CLEARSPAN

42

60

71 WS

71 WS

60

MASTER

BATH

ES

W/H

RAG

61 1/2 WS

(4)-46 1/4 PS

PANTRY

DESK

OPTIONAL

STORAGE BENCH

3'-11"

CLEARSPAN

32

24

32

24

32

24

OPT

10'-2"

5'-0"

9'-1"

16'-4 3/4"

4 1/4

3 7/8

3 1/4

3 1/4

3 7/8

10'-5 7/8"

15'-10 1/8"

25'-2 3/8"

41'-10 3/8"

13'-6 1/2"

3 1/4

14'-11 3/4"

10'-5 1/2"

16'-1 1/4"

3 7/8

3 7/8

15'-3 5/8"

25'-9 1/8"

41'-10 3/8"

13'-6 1/2"

3 1/4

DWR

OPT DW

36x80

36x80

OPT IS-2.0

30x51 ISLAND

27'-658" OPT DOMER C.L.

11'-4

5 8"

15'-3

5 8"

25'-9

3 4"

39'-5

3 4"

43'-8

1 8"

45'-10

1 8"

49'-10

1 8"

52'-8

1 8"

FURN

2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

FLOOR PLAN

PULSE PRODUCT

MDK

736RE

2/8/2017

(3)

UTILITY

LIVING ROOM

BEDROOM 2

KITCHEN

DINING

MASTER BEDROOM

BATH #2

BEDROOM 3

FAMILY ROOM

5" x 14" x 48'-6" HEAT DUCT

40'-8"

10'-1

1 2"

11'-2

1 4"

24'-10"

26'-2"

41'-6"

42'-6"

77

1 2

43'-4"

66

LAUN. SHELF

W

D

50'-0"

65

5" x 14" x 42'-0" HEAT DUCT

6'-2"

MASTER

BATH

95

7 8

PANTRY

DESK

79" X-OVER

49 1 8" X-OVER

79" X-OVER

49 1 8" X-OVER 16x8 HIGH 16x8 LOW 16x8 HIGH 16x8 LOW

NOTES:

1. ALUMINUM HEAT DUCTS

2. IN-FLOOR ALUMINUM X-OVER DUCTS

3. 4x10 REGISTERS

4. INLINE REGISTER STANDARD

5. 6" BRANCH DUCTS

39'-5"

68

24'-8"

12'-8"

3'-4"

5

5

5

8

8

8

51'-4"

2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

HVAC LAYOUT

PULSE PRODUCT

MDK

(4)

UTILITY

5 GFI WP HTR ES 5 WP 4 WP 13 12 2 2 GFI T 8 GFI 1

LIVING ROOM

BEDROOM 2

KITCHEN

DINING

MASTER BEDROOM

BATH #2

BEDROOM 3

FAMILY ROOM

LAUN. SHELF W D 4 4 4 6 6 5 8 16 4 OPT 8 GFI 4 5 5 5 5 5 6 6 6 6 6 6 6 6 4 4 4 2 4 6 5 1 GFI 2 GFI 1 GFI 1 GFI 5 W 14 15 10 11F 4 PV 19 OPT 1 GFI opt 2

MASTER

BATH

5 6 PANTRY DESK 9 SD 9 SD 9 SD 9 SD 9 SD 4 4 4 4 opt opt 5 4 C 4 C 4C 4 C W/OPT ISLAND C P 3 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

ELECTRICAL LAYOUT

PULSE PRODUCT

MDK

(5)

MAIN DRAIN LAV 1 1 2" P-TRAP WASHER 1 1/2" STAND PIPE K/S 1 1/2" P-TRAP STOOL STOOL LAV 1 1 2" P-TRAP VTR TUB 1 1 2" P-TRAP 1 1 2" 1 1 2" 1 2"1 45° ELL 1 1 2" 1 1 2" 8 1 1 2" 1 1 2" DBL WYE W/C.O. 1 1 2" 2" 3" 3" 3" DBL LTTY XLTL SANTEE DBL SANTEE 3 LTTY 1 2 3 4 5 6 WYE 7 DBL ELL 9 1 1 1 1 1 4 4 4 4 5 4 4 5 6 CO 6 CO 6 CO 45 5/8" 38" 56" 26" 44 1/8" 10" 41"

1

3" SANTEE

3" PIPE

3" C/O W/PLUG

20'

1

QUANTITY

SHIP LOOSE

3" LTTY

DESCRIPTION

1

NOTE:

1. ALL PIPE AND FITTINGS ARE ABS SCHEDULE 40.

2. ASSEMBLY OF PIPE AND FITTINGS PER CONTAINER OF GLUE AND SOLVENT.

3. MATERIAL, PIPE, AND FITTINGS BY MANUFACTURE.

4. PIPING TO BE SUPPORTED AT 4'-0" AND 1/4" PER FOOT SLOPE MAINTAINED.

5. CUT PIPE TO LENGTH, COUPLERS ARE PROVIDED.

6. DASHED LINES INDICATE FIELD INSTALLED PIPE.

7. A COPY OF THIS LAYOUT TO ACCOMPANY UNIT AS PART OF THE INSTALLATION INSTRUCTIONS.

4 3" VTR TUB 1 1 2" P-TRAP 1 1 2" 2" 1 1 3" 21" 3 4 2" 13'-2"3" 2" 13" 3 6 3" 3 3/8" 3 13-10 7/8" 3 3" 3" 3" 3" C.O. 2" 2" 1 1 2" 80 5/8" 3" 126" 74" 4 4 28" 3" 4 5 3 12" 1 12" 1 1 2" 6 3/8" 4

3" COUPLING

1

5

3"

AUTO VENT OPT GAS FURNACE 5 5 3 107" 19" 14" 1 1 2" 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

PLUMBING DWV LAYOUT

PULSE PRODUCT

MDK

(6)

WASHER STOOL TUB D/W KITCHEN SINK

X-OVER

SHUT-OFF VALVE

STOOL

COLD

HOT

W/H 3/4" INLET TUB LAV LAV 3/4" 3/4" 3/4" 3/4" 3/4"

NOTES:

1. ALL PIPING IS TUFF-PEX

2. ALL FITTINGS ARE LISTED FOR USE WITH TUFF-PEX

3. ALL LINES 1/2" UNLESS OTHERWISE SPECIFIED

4. MAIN SHUT-OFF INSTALLED AT INLET. ALL OTHER SHUT-OFFS ARE OPTIONAL.

5. WATER HEATER TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS.

3/4" OPT. ICE OPT 3/4" 3/4" FAUCET 2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

PLUMBING SUPPLY LAYOUT

PULSE PRODUCT

MDK

(7)

3/4" INLET

DRYER

FURNACE

RANGE

40,000 BTUH

54,000 BTUH

30,000 BTUH

3/4"

W/H

42,000 BTUH

3/4"

2020 MODEL: DATE: DRAWN BY: REVISION BOX WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

PLUMBING GAS LINE LAYOUT

PULSE PRODUCT

MDK

(8)

18 1 4 99 1 2 18 1 4 WATER ELECTRIC GAS 2'-0" 2'-0" 56'-0" 22'-8" 10 71 18 1 4 99 1 2 18 1 4 63 DWV DWV 49 25'-934" 39'-534" 42'-8" 29'-6" 46'-2" 51'-45 8" 29'-6"

1. THIS PRINT IS PROVIDED TO SHOW THE REQUIRED PIER LOCATION THAT ARE NOT MODIFIED BY THE SITE SOIL CLASSIFICATIONS

2. REFERENCE THE CLAYTON HOMES HUD INSTALLATION MANUAL FOR ALL LAYOUT AND DESIGN INFORMATION

3. THIS STRUCTURE HAS NOT BEEN DESIGNED TO BE LOCATED WITHIN FLOOD HAZARD LOCATIONS, WHEN SITE IS LOCATED, AUTHORITY HAVING

JURISDICTION OR FLOOD HAZARD MAPS, THE UNIT SHALL HAVE LOWEST FLOOR ELEVATED ABOVE THE DESIGNED FLOOD ELEVATION

4. THE DESIGN WIDTH IS NOMINAL AND DOES NOT TAKE INTO ACCOUNT THE OSB, SIDING, OR GAPS IN THE MATELINE AREA. A SITE INSTALLER

SHOULD CONFIRM ALL MEASUREMENTS WITH THE FINISHED STRUCTURE.

5. PERMITER BLOCKING SHOWN MAY BE OMITTED DUE TO ADDITIONAL FLOOR JOISTS PER THE SET UP MANUAL ADDENDUM SU-ADD-177.0.

1.

Wind Speed: Wind Zone 1

2. Maximum Roof Load: 30psf

3. Seismic Design Category: C

4. Max Sidewall Overhang: 12"

Perimeter blocking not Required

1. DESIGNED FOR ________ PSF ALLOWABLE SOIL IN ACCORDANCE WITH (PAGE 17 & 18) [3285.202] 2. FROST DEPTH IS _______ INCHES PER (FIGURE 5A) OR FROM LAHJ.

3. FROST PROTECTION WILL BE PROVIDED BY (Check one) : ___NA ; ___PLACING FOOTERS BELOW GRADE ; ___FROST PROTECTED DESIGN PAGE ________ ; ___FROST FREE DESIGN PAGE ___________ [3285.312(b)] 4. SPACE FRAME PIERS AT 2' FROM EACH END AND ____FT.-_____ INCHES ON CENTER BETWEEN.

5. LOAD AT EACH FRAME PIER WILL BE ________LBS. PER (TABLE 6__) without perimeter blocking OR (TABLE 7__ ) with perimeter blocking AT SPACING ABOVE.

6. SINGLE or DOUBLE (circle one) DRY or MORTARED(circle one) STACK CONCRETE BLOCKS WILL BE USED FOR ALL FRAME PIERS WHICH HAS CAPACITY OF _______ LBS PER MAX. & PIER HEIGHT IS __________ INCHES OR LESS (TABLE 9) (PAGE 31) [3285.306] 7. FRAME PIER FOOTING AREA WILL BE _______SQ. INCHES WHICH WILL BE ______INCHES (SQUARE OR DIAMETER) (circle one) (TABLE 10)

8. FOOTERS WILL BE POURED/ PRECAST/ OTHER:___________ (circle one or fill in) WITH MINIMUM DEPTH OF _______ INCHES (TABLE 10A)

9. LOAD AT SIDEWALL OPENINGS IS ________LBS. (TABLE 6d). FOOTING AREA WILL BE _______SQ. INCHES WHICH WILL BE ______INCHES (SQUARE OR DIAMETER) (circle one) (TABLE 10)

10. MATING WALL COLUMN PIERS: SPAN: ______FT.; LOAD:______LBS.; FOOTER SIZE: ______INCHES (SQUARE OR DIAMETER) (circle one); PIER CONF: ________ STACKED; (PER TABLE 5__; TABLE 10;TABLE 9)

(Reference to Clayton Homes DAPIA approved Installation manual) [Reference to Federal Statutes 24 CFR Part 3280, 3285 or 3286]

52'-0" (SEE CLAYTON INSTALLTION MANUAL FOR PIER / FOOTER LAYOUT & DESIGN INFORMATION)

2020 MODEL:

DATE: DRAWN BY: REVISION BOX

WAKARUSA, INDIANA 46573 66700 STATE ROAD 19 P.O. BOX 406

CLAYTON WAKARUSA

Div. of CMH Manufacturing West Inc. Div. of CMH Manufacturing West Inc.

FOUNDATION LAYOUT 20#

PULSE PRODUCT

MDK

736RE

References

Related documents

(4) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the

(3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest

New construction or substantial improvements of structures, including manufactured homes, shall have the lowest floor, including basement, elevated to or above the base

The total number of certified and registered commercial buildings in Europe as per May 2011, excluding local figures (i.e. excluding the total number of BREEAM projects in the UK

At depths predicted on the Hazard Maps, for 2115, the Environment Agency prefer floor levels to be raised by 1.0m, and flood resilience to be incorporated 300mm above predicted

We leverage our extensive GIS data capabilities together with geological and exploration domain expertise to address various data requirements such as geological data

SFHAs are the areas delineated on FEMA Flood Maps referred to as Flood Hazard Base Maps (FHBMs), and Flood Insurance Rate Maps (FIRMs).. These maps serve several purposes,

1) All subdivision proposals shall identify the flood hazard area and the elevation of the base flood and be consistent with the need to minimize flood damage. 2) All