Product Data Sheet

www.moteck.com

Double Motor-Twinmat

TW41/TW61

TW41/TW61 double motor is a one-piece design,

combining double motor and control, the installation steps are simple and fast, which can save labor for installing the bed frame. In addition, the complete shell protection can achieve basic dust and waterproof effects. Suitable for adjustable furniture and medical beds.

Features and Options

Main applications: Furniture, Home care Standard features:

● Max. load: 2 x 4500N (TW41) / 2 x 6000N (TW61) ● Typical speed at no load: 5mm/sec

● Stroke: 29 ~ 87mm

● Input voltage: 100V AC ~ 240V AC, 60/50Hz ● Output voltage: 29V DC

● Power supply: Internal SMPS, 29V/2A (58W) ● Max. number of controls: 1 channel

● Max. number of additional actuators: 2 channels (24V DC) ● Electric shock protection level: Class II

● Power cord: Refer to AC Power Cord ● Noise level: ≦55dB

● IP Level: IP43 ● Color: Black

● Duty cycle: 10%, max. 2 min. continuous operation in 20 min.

● Emergency lowering against power outage, to retract double motor with 9V batteries (not included) ● Operating ambient temperature: -20°C ~ +65°C

● Certified: CE marking, EMC Directive 2014/30/EU and LVD Directive 2014/35/EU (version 1 only)

Options:

● Position memory with Hall effect sensors ● IP Level: IP54

(2)

Dimensions

366 2-Ø25.2 167.5 93.3 77 581 732 11 7 Bore diameter Unit: mm

I/O Introduction

Without memory function (standard)

With memory function (option)

Hand control External actuator 2

External actuator 1

AC Power cord 9V DC batteries x 2 Protecting cap (foot side)

Driving Axis of bedframe (foot side)

Protecting cap (back side)

Driving Axis of bedframe (back side)

(3)

Compatibility

Compatible requirement Product

Without memory function (standard)

TBA3 bluetooth adapter

Compatible requirement Product

With memory function (option)

Hand control HI, H3N, H4N • Moteck control category S1• With Moteck A-type DIN plug

TBA4 bluetooth adapter RF receiver adapter: TXA5

RF control: TXH4, TXT10, TX2T, TXZ

Wireless

option • Moteck control category S1• With Moteck A-type DIN plug • Moteck control category S1 • With Moteck A-type DIN plug

Hand control HC, HD, HF, HI, HJ, HM, H2N, H3N, H3NT, HT, H3T, H4N, H2Z

RF control: TXH3, TXT7, TX2T, TXZ

RF receiver adapter: TXA4

Wireless option

Actuator FD60, FD61, MK33

• Moteck control category P1 • With Moteck A-type DIN plug

• 24V DC, max. 3A current

• With Moteck A2-type DIN 41529 plug • Moteck control category P1

• With Moteck A-type DIN plug

• 24V DC, max. 3A current

• With Moteck A2-type DIN 41529 plug

Model

(4)

Socket

A-type plug (GND) LED Data (GND) Data +5V LED

5-pin socket 5-pin plug

+5V

Hand control socket (for Moteck A-type DIN plug)

● Without memory function (Moteck control category P1) - 4 drives model

- 3 drives model

- 2 drives model

● With memory function (Moteck control category S1)

M2 Down M2 Up Vin M3 Down M3 Up M1 Down 8-pin socket M1 Down Vin M3 Up M2 Down M2 Up M3 Down 8-pin plug M4 Down M1 Up M4 Up M1 Up M4 Up M1 Up M2 Down M2 Up Vin M3 Down M3 Up M1 Down 8-pin socket M1 Up M1 Down Vin M3 Up M2 Down M2 Up M3 Down 7-pin plug (GND) M1 Up M2 Down M2 Up Vin M1 Down M1 Up M1 Down Vin M2 Down M2 Up

5-pin socket 5-pin plug

(GND) (GND)

(GND)

(5)

• AC power cord length: 3000mm straight • Color: Black or RAL7035

EU Plug

Plug type

AC Power cord

Note

Certifications

The TW41/TW61 double motor is compliant with the following regulations. ● EMC Directive 2014/30/EU

● LVD Directive 2014/35/EU EN 55014-2:2015 Catagory II IEC 61000-4-2:2008 IEC 61000-4-4:2012 IEC 61000-4-5:2014 IEC 61000-4-6:2013 IEC 61000-4-11:2004 EN 55014-1:2017 IEC 61000-3-2:2014 IEC 61000-3-3:2013 Emission Immunity EN 60335-1:2012+A11:2014+A13:2017 Standard

(6)

Ordering Key

4: 4500N 6: 6000N Max. load

54

3

2

1

TW 6 1-

ISW1

- 87 .

69

- 1 -

2

-Stroke for leg

Stroke for back 29 ~ 87mm

Socket for control 1: 1 socket

29 ~ 87mm

Number of drive 2: 2 motors3: 2 motors + 1 additional socket 4: 2 motors + 2 additional sockets

IP Level Blank: None54: IP54

Cable 3: 3000mm straight

Bore diameter 2: 25.2mm (standard)6: 25.6mm

Battery 0: None1: With 9V DC battery x 2

Input voltage ISW1: Internal SMPS (100 ~ 240V AC)

(7)

Ordering Key

4: 4500N 6: 6000N Max. load

54

3

2

1

TW 6 1-

ISW1

- 87 .

69

- 1 -

2

- HS

Stroke for leg

Stroke for back 29 ~ 87mm

Socket for control 1: 1 socket

29 ~ 87mm

Number of drive 2: 2 motors

IP Level Blank: None54: IP54

Cable 3: 3000mm straight

Bore diameter 2: 25.2mm (standard)6: 25.6mm

Battery 0: None1: With 9V DC battery x 2

HS: Position memory with Hall effect sensors Memory function

Input voltage ISW1: Internal SMPS (100 ~ 240V AC)

-www.moteck.com Terms of Use

The user is responsible for application suitability of Moteck products. As ongoing improvement process continues, products listed on the Moteck website are subject to change without prior notice. Moteck reserves the right to terminate the sales or remove any product displayed on the website, or listed in its catalogues.

References

Related documents

The performance involves the participation of the king of Ataoja of osogbo, Arugba (votary mad) Aworo Osun , Iya Osun (chief priest and priestess), and the entire  people

The project was a joint venture by Kellogg Community College and the Miller Foundation to develop an upper division private college allowing students to have a seamless

You understand that Atlantic Broadband reserves the right to act immediately and without notice to you to terminate or suspend the Service and/or to remove from the Service

The lift to drag ratio increases as the angle of attack increased on both wings, for rear wing the lift to drag ratio is reduced when compared to that of front wing due to

relevance to physical theatre and/or actor training have been Movement Training for the Modern Actor by Simon Murray (2003) Actor Training (2000) and Twentieth Century Actor

The emerging cosmo- politan constitutionalism is based upon three ideas: first, the exercise of state authority must also be legitimate from the perspective of those who are

Under Local Law 87, the Association of Energy Engineers' Certified Building Commissioning Firm, Certified Building Commissioning Professional, and Existing

The main objective is to find out the major difficulties returnees face in reintegrating into their societies of origin after being forced to return home and