• No results found

Safety Nonstop for airports. Seamless safety throughout all areas

N/A
N/A
Protected

Academic year: 2021

Share "Safety Nonstop for airports. Seamless safety throughout all areas"

Copied!
8
0
0

Loading.... (view fulltext now)

Full text

(1)

Safety Nonstop for airports

Seamless safety throughout all areas

(2)

Safety Nonstop for airports

40 years experience in safety technology

HIMA safety systems protect the assets of the world’s major oil and gas, chemical, pharmaceutical and energy-producing companies as well as systems in the fi elds of logistics, machine safety and rail traffi c. We have applied this know-how and our broad experience to the development of safe and proven solutions for a wide variety of airport areas. Our highly qualifi ed engineers have extensive experience with airport applications.

Permanent safety and profi tability

All HIMA airport solutions are based on proven HIMA safety controllers, featuring intuitive programming and the capacity to be networked and integrated with cross-manufacturer communication interfaces. The result: HIMA solutions are always a perfect fi t in any technical environment, whether it involves a conversion project or new investment. As with all HIMA solutions, the foundation of the company’s solu-tions is the ‘Safety. Nonstop.’ principle. They not only create permanent safety, but they also prevent unnecessary stops and help to achieve uninterrupted and profi table system/ plant operations.

HIMA LIFECYCLE SERVICES

The operators of airport systems, like all HIMA customers, ben-efi t from the comprehensive and versatile services we provide.

HIMA Lifecycle Services offers an overview of all functional safety requirements and consistently supports the right decision at the right time.

More information at: www.hima.com/Lifecycle_Services efi t from the comprehensive and versatile services we provide.

HIMA Lifecycle Services offers an overview of all functional

HIMA. Safety. Nonstop.

It’s a philosophy more than 100 years in the making. It’s built on HIMA’s singular focus on safety and is proven by decades of technology breakthroughs. It represents our commitment to providing maximum safety and uninterrupted plant operations. Our goal isn’t just to design the world’s best safety systems. It’s to help keep your business safe and running. No shutdowns. No failures. Maximum uptime. Maximum profi tability.

(3)

In the airport safety sector, HIMA offers solutions for nearly all safety-critical applications. Whether refuelling systems, baggage handling systems or terminals: HIMA offers seamless safety throughout all areas. Based on its proven safety technol-ogy, HIMA provides innovative solutions, powerful products and extensive services. The advantages for the airport operator: Maximum safety, fl exibility and profi tability.

Seamless safety throughout all areas

Safety

Independent safety networks

Uncritical compound of safety-related and non-safety-related data

Safety-related data transmission with safeethernet

Redundancy

Fastest response times

Detailed diagnosis

Alarms via systems such as panels, SMS, PDA, etc.

Processing of complex data

Flexibility

Modular structure allows changes and extensions at any point in time in accordance with the individual needs

A broad range of network topologies are supported

Optimal adaptability to the local plant structure thanks

to a comprehensive hardware portfolio, open interfaces and numerous communication options

Media-independent data transfer

Simple integration in existing machinery, process and building control systems

Profi tability

Standard Ethernet technology

Higher plant availability thanks to distributed intelligence

Centralized and decentralized PES structures

No costly and error-prone interfaces

Offl ine logic simulation

Single-channel design of safety loops

Reduced installation efforts

High degree of planning and investment fl exibility thanks to open systems

(4)

Airport safety often depends on responses within frac-tions of a second. HIMA solufrac-tions are as quick as a fl ash. Featuring very short response times of up to 5 ms, our HIMatrix® series safety-related controllers and remote

I/Os are among the fastest of their type in the world.

Combining the HIMatrix safety-related systems with the safety bus safeethernet, the high-availability HIMax®

sys-tem and guaranteed redundant communications, HIMA is able to provide the perfect safety solutions for airports.

Fast reaction and high availability

HIMatrix safety controllers

Compact and modular safety controllers as well as remote I/O modules

Proven HIMA safety technology

Certifi ed for use up to SIL 3 in accordance with IEC 61508 50128 and up to PL e in accordance with EN 13849

Response times of 5 ms possible

Communication: Ethernet TCP/UDP, RS485, RS422, RS232

Communication via safeethernet and numerous industrial

protocols such as PROFINET, PROFIsafe via PROFINET, Modbus TCP. Proprietary protocols can be created by the user

If necessary, the high-availability safety system can

be integrated into the network

Four scenarios exemplify how HIMA safety systems work

Scenario 1: Leak in the kerosene pipeline to the tank farm

There is an extremely high risk of fi re and explosion. HIMA's emergency shutdown (ESD) system detects and locates the leak. The affected pipeline area is shut down immediately. The integration of the HIMA sys-tem into the airport control syssys-tem ensures that the emergency scenarios for the nearby parking garage run according to plan.

Scenario 2: Fire in the terminal

Due to a short-circuit, a coffee machine in a terminal service room catches fi re. The fi re detection system alerts the HIMatrix system. All corresponding safety functions are triggered quickly and reliably. HIMA's in-telligent evacuation management initiates evacuation in the affected part of the building. A mixing of people in restricted und unrestricted areas is avoided; impact on airport traffi c is insignifi cant.

Scenario 3: Accident in the baggage conveyor system

Maintenance work is progressing on the baggage con-veyor system. Suddenly, someone screams. A worker is pulled by the hand into the conveyor system. But thanks to HIMA's networked safety system, another staff member can activate the emergency stop from a distance and shut down the plant in a split second.

Scenario 4: Explosion on the airport apron

A plane waiting on the airport apron is losing oil from its engine. It catches fi re, and the jet engine explodes. The refuelling plant is safely shut down through the network of remote HIMatrix systems, the airport fi re department is informed and the evacuation of the neighbouring departure terminal is initiated. The re-dundant ring structure for communication guarantees the maximum availability of all systems.

If necessary, the safety network can be structured redundantly

HIMatrix – HIMax, redundant network via safeethernet

(5)

HIMA's safety solutions control and regulate dynamic scenarios. The safety-related programmable logic controllers (PLCs) serve as superordinate management systems and reliably connect the broadest variety of different protection-relevant

areas with one another. All components and I/O extensions (RIOs) are integrated into the overall signalling concept of the airport. The connection to the existing airport control system is established via a protocol such as Modbus TCP.

Fully integration capable

An engineering tool for all the functions

SILworX® is the fully integrated confi guration, programming

and diagnostic tool from HIMA. The intuitive user interface with graphical drag and drop programming reduces application errors and speeds up the engineering process. A range of user levels, the display of all status and diagnostic information, and comprehensive validation tools guarantee quick planning and commissioning.

Flexible programming using function block diagrams, sequential function charts

IEC 61131-3 compliant, supporting all functions and variable types for safety-related programming

Seamless control throughout all levels

safeethernet solutions are based on standard Ethernet technology (IEEE 802.3) and offer:

TÜV-certifi ed up to PL e, Cat. 4, and SIL 3

Data transfer at 100 Mbit/s

Very short reaction times ensured within the required safety time

No restrictions in terms of physical distance

Up to 128 systems per Ethernet segment can be networked

Intelligent, diversifi ed redundancy concepts

Integration of safety-related and non-safety-related data into existing standard Ethernet networks – without impairing safety

Transfer media: copper, ISDN/DSL, fi bre optic cables, satellites and wireless applications

Line, tree, start and ring structures

References I For more information, refer to our website www.hima.com

Baggage conveyor system at the Frankfurt am Main Airport

Refuelling system at the OT Tambo International Airport (JNB), Johannes b.

Jet A1 pipeline Hannover Airport Emergency power supply at the Munich Airport

(6)

Eine detaillierte Liste aller Niederlassungen und Vertretungen fi nden Sie unter: www.hima.de/kontakt

96 9000513 0911 V01

© 2011 HIMA Paul Hildebrandt GmbH + Co KG

HIMax, HIMatrix and SILworX are registered trademarks of HIMA Paul Hildebrandt GmbH + Co KG

Specifi cations are subject to change.

HIMA Paul Hildebrandt GmbH + Co KG

Albert-Bassermann-Str. 28 68782 Brühl, Germany Phone +49 6202 709-0 Fax +49 6202 709-107 info@hima.com www.hima.com

For a detailed list of all our subsidiaries and representatives, please visit our website: www.hima.com/contact

(7)

Safety Nonstop for airports

40 years experience in safety technology

HIMA safety systems protect the assets of the world’s major oil and gas, chemical, pharmaceutical and energy-producing companies as well as systems in the fi elds of logistics, machine safety and rail traffi c. We have applied this know-how and our broad experience to the development of safe and proven solutions for a wide variety of airport areas. Our highly qualifi ed engineers have extensive experience with airport applications.

Permanent safety and profi tability

All HIMA airport solutions are based on proven HIMA safety controllers, featuring intuitive programming and the capacity to be networked and integrated with cross-manufacturer communication interfaces. The result: HIMA solutions are always a perfect fi t in any technical environment, whether it involves a conversion project or new investment. As with all HIMA solutions, the foundation of the company’s solu-tions is the ‘Safety. Nonstop.’ principle. They not only create permanent safety, but they also prevent unnecessary stops and help to achieve uninterrupted and profi table system/ plant operations.

HIMA LIFECYCLE SERVICES

The operators of airport systems, like all HIMA customers, ben-efi t from the comprehensive and versatile services we provide.

HIMA Lifecycle Services offers an overview of all functional safety requirements and consistently supports the right decision at the right time.

More information at: www.hima.com/Lifecycle_Services

Safety Nonstop for airports

Seamless safety throughout all areas

Eine detaillierte Liste aller Niederlassungen und Vertretungen fi nden Sie unter: www.hima.de/kontakt

efi t from the comprehensive and versatile services we provide.

HIMA Lifecycle Services offers an overview of all functional

HIMA. Safety. Nonstop.

It’s a philosophy more than 100 years in the making. It’s built on HIMA’s singular focus on safety and is proven by decades of technology breakthroughs. It represents our commitment to providing maximum safety and uninterrupted plant operations. Our goal isn’t just to design the world’s best safety systems. It’s to help keep your business safe and running. No shutdowns. No failures. Maximum uptime. Maximum profi tability.

96 9000513 0911 V01

© 2011 HIMA Paul Hildebrandt GmbH + Co KG

HIMax, HIMatrix and SILworX are registered trademarks of HIMA Paul Hildebrandt GmbH + Co KG

Specifi cations are subject to change.

HIMA Paul Hildebrandt GmbH + Co KG

Albert-Bassermann-Str. 28 68782 Brühl, Germany Phone +49 6202 709-0 Fax +49 6202 709-107 info@hima.com www.hima.com

For a detailed list of all our subsidiaries and representatives, please visit our website: www.hima.com/contact

(8)

In the airport safety sector, HIMA offers solutions for nearly all safety-critical applications. Whether refuelling systems, baggage handling systems or terminals: HIMA offers seamless safety throughout all areas. Based on its proven safety technol-ogy, HIMA provides innovative solutions, powerful products and extensive services. The advantages for the airport operator: Maximum safety, fl exibility and profi tability.

Airport safety often depends on responses within frac-tions of a second. HIMA solufrac-tions are as quick as a fl ash. Featuring very short response times of up to 5 ms, our HIMatrix® series safety-related controllers and remote

I/Os are among the fastest of their type in the world.

HIMA's safety solutions control and regulate dynamic scenarios. The safety-related programmable logic controllers (PLCs) serve as superordinate management systems and reliably connect the broadest variety of different protection-relevant Combining the HIMatrix safety-related systems with the

safety bus safeethernet, the high-availability HIMax®

sys-tem and guaranteed redundant communications, HIMA is able to provide the perfect safety solutions for airports.

areas with one another. All components and I/O extensions (RIOs) are integrated into the overall signalling concept of the airport. The connection to the existing airport control system is established via a protocol such as Modbus TCP.

Fast reaction and high availability

Fully integration capable

Seamless safety throughout all areas

An engineering tool for all the functions

SILworX® is the fully integrated confi guration, programming

and diagnostic tool from HIMA. The intuitive user interface with graphical drag and drop programming reduces application errors and speeds up the engineering process. A range of user levels, the display of all status and diagnostic information, and comprehensive validation tools guarantee quick planning and commissioning.

Flexible programming using function block diagrams, sequential function charts

IEC 61131-3 compliant, supporting all functions and variable types for safety-related programming

HIMatrix safety controllers

Compact and modular safety controllers as well as remote I/O modules

Proven HIMA safety technology

Certifi ed for use up to SIL 3 in accordance with IEC 61508 50128 and up to PL e in accordance with EN 13849

Response times of 5 ms possible

Communication: Ethernet TCP/UDP, RS485, RS422, RS232

Communication via safeethernet and numerous industrial

protocols such as PROFINET, PROFIsafe via PROFINET, Modbus TCP. Proprietary protocols can be created by the user

If necessary, the high-availability safety system can

be integrated into the network

Four scenarios exemplify how HIMA safety systems work

Seamless control throughout all levels

Safety

Independent safety networks

Uncritical compound of safety-related and non-safety-related data

Safety-related data transmission with safeethernet

Redundancy

Fastest response times

Detailed diagnosis

Alarms via systems such as panels, SMS, PDA, etc.

Processing of complex data

Flexibility

Modular structure allows changes and extensions at any point in time in accordance with the individual needs

A broad range of network topologies are supported

Optimal adaptability to the local plant structure thanks

to a comprehensive hardware portfolio, open interfaces and numerous communication options

Media-independent data transfer

Simple integration in existing machinery, process and building control systems

Profi tability

Standard Ethernet technology

Higher plant availability thanks to distributed intelligence

Centralized and decentralized PES structures

No costly and error-prone interfaces

Offl ine logic simulation

Single-channel design of safety loops

Reduced installation efforts

High degree of planning and investment fl exibility thanks to open systems

safeethernet solutions are based on standard Ethernet technology (IEEE 802.3) and offer:

TÜV-certifi ed up to PL e, Cat. 4, and SIL 3

Data transfer at 100 Mbit/s

Very short reaction times ensured within the required safety time

No restrictions in terms of physical distance

Up to 128 systems per Ethernet segment can be networked

Intelligent, diversifi ed redundancy concepts

Integration of safety-related and non-safety-related data into existing standard Ethernet networks – without impairing safety

Transfer media: copper, ISDN/DSL, fi bre optic cables, satellites and wireless applications

Line, tree, start and ring structures

Scenario 1: Leak in the kerosene pipeline to the tank farm

There is an extremely high risk of fi re and explosion. HIMA's emergency shutdown (ESD) system detects and locates the leak. The affected pipeline area is shut down immediately. The integration of the HIMA sys-tem into the airport control syssys-tem ensures that the emergency scenarios for the nearby parking garage run according to plan.

Scenario 2: Fire in the terminal

Due to a short-circuit, a coffee machine in a terminal service room catches fi re. The fi re detection system alerts the HIMatrix system. All corresponding safety functions are triggered quickly and reliably. HIMA's in-telligent evacuation management initiates evacuation in the affected part of the building. A mixing of people in restricted und unrestricted areas is avoided; impact on airport traffi c is insignifi cant.

Scenario 3: Accident in the baggage conveyor system

Maintenance work is progressing on the baggage con-veyor system. Suddenly, someone screams. A worker is pulled by the hand into the conveyor system. But thanks to HIMA's networked safety system, another staff member can activate the emergency stop from a distance and shut down the plant in a split second.

Scenario 4: Explosion on the airport apron

A plane waiting on the airport apron is losing oil from its engine. It catches fi re, and the jet engine explodes. The refuelling plant is safely shut down through the network of remote HIMatrix systems, the airport fi re department is informed and the evacuation of the neighbouring departure terminal is initiated. The re-dundant ring structure for communication guarantees the maximum availability of all systems.

If necessary, the safety network can be structured redundantly

HIMatrix – HIMax, redundant network via safeethernet

References I For more information, refer to our website www.hima.com

Baggage conveyor system at the Frankfurt am Main Airport

Refuelling system at the OT Tambo International Airport (JNB), Johannes b.

Jet A1 pipeline Hannover Airport Emergency power supply at the Munich Airport

References

Related documents

It has been asked to companies who participated to the 2011 market research study to evaluate their technology usage level by using 1 to 5 point scale; 1 means minimum involvement and

Some recommendations along with dna replication practice answer key will open in the classic edition of your dna replication work answers to pair with student worksheet was a

Do we make sure that Health & Safety Representatives or Joint Health & Safety Committee members receive the required training.. (E.g. In Ontario, selected Joint Health

Evidence for the FRYL - SH2D1A fusion showing the validated fusion boundary (vertical red line). a) Validation evidence using a FISH come together assay, with fusion probes circled

addition, the estimates for A 3 show that no lagged yield factor affects significantly any current macro factor; while, in A 2 , the inflation rate has a positive and

In addition, NCGAS staff have managed and updated a total of 52 bioinformatics and genome analysis software packages on a variety of computing resources available to US

INFORMATION ABOUT: The behaviors that exemplary leaders practice to lead their organizations through conversation using the four elements of conversational leadership:.

Standard Advanced 24/7/365 Support • • Unlimited support cases and authorized contacts • • Software downloads, updates and maintenance • • Phone, email and web-based