Web Interface User’s Guide

Version 0.3

(2)

- ii -

Tables Of Content

1. INTRODUCTION... 1

1.1 MAIN FEATURES... 2

2. YOUR ANALOG TELEPHONE ADAPTOR (ATA) AT A GLANCE... 3

2.1 PORTS AND BUTTONS... 3

2.2 LED DESCRIPTION... 3

3. INSTALLING YOUR ATA ... 4

3.1 FOR SINGLE-USER CONNECTION... 4

3.2 FOR MULTIPLE-USERS CONNECTION... 5

3.3 FOR COMPANY NETWORK CONNECTION... 6

4. SETTING UP YOUR V300ATA ROUTER FUNCTIONALITY VIA GUI ... 7

4.1 ACCESS TO V300ATA GUI. ... 7

4.2 SETUP MODE... 7 5 BASIC MODE... 8 5.1 OVERALL STATUS... 9 5.2 LAN STATUS... 10 5.3 DHCP CLIENT STATUS... 11 5.4 PPP STATUS... 12 5.5 TCP STATUS... 13 5.6 SYSTEM LOG... 14 6 BASIC CONFIGURATIONS ... 15 6.1 WAN CONFIGURATION... 15

6.2 LAN & DHCP CONFIGURATION... 18

6.3 NAT CONFIGURATION... 20

6.4 PORT FORWARDING CONFIGURATION... 22

6.5 BRIDGE FILTERING... 23

6.6 DNS CONFIGURATION... 24

6.7 SAVE SETTINGS / REBOOT... 25

7. ADVANCED MODE ... 27

7.1 ATA CONFIGURATION... 27

7.2 SIP SERVICE PROVIDER CONFIGURATION... 28

7.2.1 SIP Service Provider... 28

7.3 ATA LOGIN ACCOUNT CONFIGURATION... 30

7.4 ATA TIMER CONFIGURATION... 32

7.5 COUNTRY SPECIFIC RING & TONES CONFIGURATION... 33

7.6 ATA MISC CONFIGURATION... 35

(3)

- iii -

8.1 ROUTE TABLE... 38

8.1.2 Route Configuration... 39

8.2 BRIDGE MAC TABLE... 40

8.3 RIP SYSTEM WIDE CONFIGURATION... 40

8.4 DMZ CONFIGURATION... 43

8.5 SNTP CONFIGURATION... 44

8.6 MISCELLANEOUS CONFIGURATION... 45

8.7 ADMIN USERNAME / PASSWORD CONFIGURATION... 47

8.8 RESET TO DEFAULT... 47

8.9 FIRMWARE UPDATE... 48

(4)

- 1 -

1. Introduction

Thank you on your purchase of the VoIP V300ATA

The V300ATA VoIP Analog Telephone Adaptor (ATA) products are standards-based communication devices that deliver true, next-generation voice-over-IP (VoIP) terminations to residences worldwide. Internet telephony employs a variety of protocols, including Real-time Transport Protocol (RTP) for transport of mulReal-timedia data and Session Initiation Protocol (SIP) for call signaling and control.

The V300ATA series are mixed-environment adaptors that interface legacy analog telephones, fax machines, analog conference telephones and other analog devices to IP based telephony networks thereby allowing users and ISPs to protect prior investments in analog phones, fax machines, and speakerphones, and migrate to IP at their own pace. These products address the needs of small-office environments, and the emerging VoIP voice services whereby ISPs value add their ADSL or Cable Modem offering with VoIP services by turning their analog devices into IP devices.

The V300ATA is installed at the subscriber's premises and supports one voice ports with a POTS bypass for using the existing POTS primary line. The V300ATA supports 2 10/100BaseT Ethernet ports. This adaptor can make use of existing broadband pipes such as digital subscriber line (DSL), fixed wireless and cable modem deployments. In addition, the V300ATA has an internal Ethernet switch with routing capability, which allows for a direct connection to another 10/100BASE-T Ethernet network via an RJ-45 interface, with single LAN connectivity for both the V300ATA and a co-located PC or other Ethernet-based device.

By turning any analog telephone into an IP telephone, the V300ATAs address the needs of the emerging market of "second-line" residential voice-over-IP (VoIP) services. Broadband service providers can now deploy voice services quickly to grow revenues and facilitate the development of new services.

(5)

- 2 - 1.1 Main Features

• Call Out & Call In

• Voice over IP c all (through Gatekeeper) • PSTN phone call (bypass I )

• IP address calling (Future Firmware Upgrade)

• Conference call (Ad Hoc Conference Call) (Up to Three Participants) • Call features

• Call Waiting • Call Hold • Call Forward • Call ID

• Setup & Configuration

• Auto (remote) Software Upgrade • Web Based Configuration

• Password Protection for Web Configuration • Audio Codec Feature

• Supports G.711, G.723,G.726,G.729a • Voice Activity Detection

• Silence Compression • Comfort Noise Generation • Echo Cancellation

• Jitter Provisioning • Protocols

• SIP (Default)

• T.38 Fax over IP support • DHCP client

• DNS client • Static IP • FTP

• HTTP Server for Web Management (Firmware Upgrade)

(6)

- 3 -

2. Your Analog Telephone Adaptor (ATA) at a glance

The V300ATA may have different ports and LEDs. Let’s take a look at the different options. Depending upon your model, it may have some or all of the features listed below

2.1 Ports and buttons

12V Power is where you connect the power. Make sure to observe the proper power requirements. The require power is 12 volts.

Modem: 10/100 Base-T RJ-45 socket which is to be connected to your ADSL or Cable modem.

Ethernet: 10/100 Base-T RJ-45 socket which is to be connected to your PC or to a hub/switch if you want multiple PC access.

Reset and Restore to Factory Defaults: The restore to factory defaults feature will set the V300ATA to its factory default configuration by resetting the V300ATA. You may need to place the V300ATA into its factory defaults if the configuration is changed, you will lose the ability to interface to the V300ATA via the web interface, or following a software upgrade,. To reset the V300ATA, simply press the reset button for about ~ 8 seconds. The V300ATA will be reset to its factory defaults and after about 30 ~ 40 seconds the V300ATA will become operational again.

Phone: RJ-11 telephone socket, which is to be connected to an PSTN analog phone.

Line: RJ-11 telephone socket, which is to be connected to telephone wall socket. In by-pass mode, the PSTN signal will be send to the analog phone

2.2 LED description

IN USE: Lights up when the device is powered up and the telephone handset is off-hook

READY: Lights up when VoIP service is in operational mode.

ETH: Lights up when Ethernet link is detected and blinks according to LAN Ethernet traffic.

WAN: Lights up when WAN link is detected and blinks according to WAN traffic.

PWR: Lights up when device is power on.

(7)

- 4 -

3. Installing your ATA

3.1 For Single-User Connection

The following shows a typical single-user connection. You need to have a ADSL modem or

Cable modem before you can connect to the ATA. It can be placed behind router or straight

from the moem. Check if your Computer/Notebook has an Ethernet Port. The Telephone set is connected to the RJ-11 3.1.1 ADSL Connection www ADSL Modem / Router Computer/Network with Ethernet Network Card

Telephone Set

internet Telephone V300ATA

Wall Socket

POTS Splitter

Figure 3-1: Connection via ADSL for single User

3.1.2 Cable Connection

w w w

Cable

Modem Computer/Network withEthernet Network Card Telephone Set internet Telephone Wall Socket Cable Point Cable/DSL Router V300ATA

(8)

- 5 - 3.2 For Multiple-Users Connection

If you want to connect more than a one Computers/Notebooks connection, you may connect the ATA to a switch/hub; the switch/hub will then be connected to the other Computers/Notebook. The diagram below shows multiple-users connection using ADSL. Cable users connection is similar to the ADSL, by using an Ethernet (RJ-45) cable, connect it from V300ATA to a Hub/Switch.

Hub/Switch w w w Computer/ Network with Ethernet Network Card Telephone Set internet Telephone Wall Socket POTS Splitter Computer/ Network with Ethernet Network Card ADSL Modem / Router V300ATA

Figure 3-3: Connection via ADSL /Cable or multiple users

For details on the connection and types of Ethernet Network cable to use with the Ethernet Hub/Switch, please refer to the user guide that comes with your Ethernet Hub/Switch.

(9)

- 6 - 3.3 For Company Network Connection

Please seek advise from your company’s Network Administrator, to open ports 5000,5060 for the VoIP functions.

w w w

Computer/Network with Ethernet Network Card

Telephone Set internet Telephone Wall Socket Company Network

(10)

- 7 -

4. Setting up your V300ATA router functionality via GUI

4.1 Access to V300ATA GUI.

To configure your V300ATA, you need to login to the device using a web browser. i) Connect the V300ATA as shown in the Section 3.

ii) Launch your web browser.

iii) Type in 10.0.0.99 at the Address bar and press Enter key. (Note: 10.0.0.99 is the default IP address for Router).

4.2 Setup Mode.

Upon successfully logging in, the Setup mode screen as shown below is displayed. Note :

Please refer the Easy Start Manual, ”Step 5 VoIP Configuration Setup” for the details

(11)

- 8 -

5 Basic

Mode

It provides a brief outline of the router function of individual hyper links on the left menu.

(12)

- 9 - 5.1 Overall Status

It summaries all the information regarding the WAN and LAN of the V300ATA Firmware Version: This section displays the current version of ATA Firmware.

WAN Connection Type: It shows the type of connection that is currently used. It will show Connected when it get connected to ISP.

WAN Statistic: This shows the WAN interface IP address assigned to your router.

LAN Statistic: This shows the number of computers connected to the router. It also shows the LAN interface IP addresses assigned to the computers.

(13)

- 10 - 5.2 LAN Status

It fields display the IP address, Subnet Mask and MAC address for the LAN interface.

Figure: 5-2: LAN Status

Total Number of LAN Interfaces: This field displays the total number of available interfaces for the LAN interface. The total number of available interfaces is the amount of

computers that are able to hook up to the DHCP Server.

Number of Ethernet Devices Connected to the DHCP Server: These fields display the DHCP client table with the assigned IP addresses and MAC addresses.

Note: If there are no devices connected to the DHCP server, then a table will not appear, otherwise a table (Table Headings: IP Address, MAC Address) listing all devices connected to DHCP server will appear on the bottom of the page.

(14)

- 11 - 5.3 DHCP Client Status

This page displays the WAN IP address which is assigned by the ISP. • Select Release or Renew in the list box

Press Execute to Renew or Release the WAN connection.

(15)

- 12 - 5.4 PPP Status

This page displays the status of each PPP session for each PPP interface. This page contains information that is dynamic and will refresh every 8 seconds.

To Connect/Disconnect PPP connection:

1. Type the connection number you want to Connect/Disconnect in the text field 2. Select Connect or Disconnect in the list box

3. Press Execute to Connect or Disconnect the selected PPP connection. (Note: For cable modem users, you are not able to connect using this option.)

Figure: 5-4: PPP Status

PPP (Point-to-Point Protocol): The table displays the following fields:

• Connection Name: This is user defined. User defined connections for PPP can be created in PPP Configuration page.

• Interface: States the interface that is being used (PVC0 ... PVC7). • Mode: There are two available modes for the connection:

PPP over Ethernet (PPPoE)

• Status: States whether PPP connection is Connected or Not Connected. • Packets Sent: Number of packets sent by a particular PPP Connection.

• Packets Received: Number of packets received by a particular PPP Connection. • Bytes Sent: Number of bytes sent by a particular PPP Connection.

• Bytes Received: Number bytes received by a particular PPP Connection.

Connect and Disconnect: This field allows you to manually connect/disconnect the PPP connection for each PPP interface. In other words, each PPP session can be connected and disconnected individually.

(16)

- 13 -

• Connect/Disconnect Execute: Press this button to either connect or disconnect. Connection status dialog will be displayed below the Execute button after it is pressed. Sample dialog with explanation:

• PPP X: Connecting... This is displayed while the PPP session is attempting connect to the ISP.

• PPP X: Connect ERROR This is displayed when a connection cannot be made due to an error.

• PPP X: is currently not connected This is displayed when a disconnect attempt is made on a session that is not currently connected.

PPP X: does not exist! This is displayed when a connect or disconnect attempt is made on a session number that does not exist.

5.5 TCP Status

This page displays all the relevant TCP packets and data information. You can reset the counters to clear all the attributes.

Figure: 5-5: TCP Status

Reset Counters: This button allows user to reset the TCP Status counter.

General: Total Packets, Data Packets, Data Bytes, Out of Order Packets, Out of Order Bytes Discarded Packets: Bad Checksum, Bad Offset Header, Too Short

(17)

- 14 - 5.6 System Log

The System Log page shows the events triggered by the system.

This page contains information that is dynamic and will refresh every 5 seconds.

Figure: 5-6: System Log

Clear Log: This field allows you to clear the current contents of the System Log.

Save Log: This field allows you to save the current contents of the System Log by right click HERE and select “Save Target As” to save it into a text file.

(18)

- 15 -

6 Basic Configurations

6.1 WAN Configuration

This page let you configure the WAN settings.

Figure 6-1 WAN Configuration

Bridge: Enable to connect the LAN to the WAN (bridge the two connections). This is available in Bridge Mode only. Default is Disabled.

IGMP: IGMP (Internet Group Management Protocol) relay/proxy specification and environment, default is Disabled. IGMP is available in all modes and all encapsulations. Support IGMP proxy/relay function for ADSL Bridge/Router, based on the following requirement and cases:

• On CO side, there must be at least one IGMP querier (router) present. IGMP querier will send IGMP query packet. The ADSL Bridge/Router is responsible to relay these IGMP queries to Ethernet.

• End-user multicast application device sends IGMP report while receiving IGMP query or being activated by the user. The ADSL Bridge/Router should be responsible to proxy (that is, change source IP to ADSL Bridge/Router’s WAN IP) the IGMP report to ADSL WAN side, including all PVCs. The same case is for IGMP leave packet.

• Not necessary to relay multicast routing between two ADSL PVCs or two interfaces in LAN side.

(19)

- 16 -

• Special purpose multicast packet (such as RIP 2 packet) should run without Interference.

Static IP Settings are for users who have a Static IP Address (WAN side) from their ISP. IP Address: This is the static IP Address given by the ISP.

Range for IP Address is x.x.x.y, where 0 ≤ x≤ 255 and 1 ≤ y≤ 254, default is 192.168.241.101.

Subnet Mask: This is the subnet mask given by the ISP.

Range for Subnet Mask is x.x.x.x, where 0 ≤ x≤ 255, default is 255.255.255.0

Gateway: This is the Gateway given by the ISP.

Range for Gateway is x.x.x.y, where 0 ≤ x≤ 255 and 1 ≤ y≤ 254, default is 0.0.0.0.

Gateway: This is the Gateway IP address provided by your ISP

DHCP Client: This is to enable or disable (default) the ADSL Bridge/Router WAN as a DHCP client, where the ISP would be the DHCP server. DHCP Client is generally used in the following encapsulations: 1483 Bridged IP LLC, 1483 Routed IP LLC, 1483 Bridged IP VC-MUX, 1483 Routed IP VC-Mux, and Classical IP over ATM. This option is for non-static (dynamic) IP addresses.

Host Name: When DHCP Client is Enabled, copy the ISP recognized Host Name here. The Host Name can be up to 19 characters.

MAC Spoofing: Enable MAC Spoofing to make a different MAC Address appear on the WAN side. This is also used to solve the scenario where the ISP only recognizes one MAC Address.

Default is Disabled.

MAC Address: When MAC Spoofing is enabled, copy the ISP-recognized MAC address here. Format for MAC address is six pairs of hexadecimal numbers (0-9, A-F) separated by colons.

Default is 00:00:00:00:00:00.

PPP: Default is unchecking, check to enable.

User Name: Enter the PPP user name (provided by the ISP). The User Name can be up to 127 characters.

Password: Enter the PPP password (provided by the ISP). The Password is not needed to delete or modify the account. The Password can be up to 127 characters.

PPP Account Configuration Status table will be displayed at the bottom of this page to show all the accounts (Table headings: Account Name and User Name). The status table does not display the password.

(20)

- 17 -

MRU: The MRU (Maximum Receive Unit) field indicates the maximum size IP packet that the peer of PPP connection (this device) can receive. During the PPP negotiation, the peer of the PPP connection will indicate its MRU and will accept any value up to that size. The actual MTU of the PPP connection will be set to the smaller of the two (MTU and the peer’s MRU). In the normal negotiation, the peer will accept this MRU and will not send packet with information field larger than this value.

Range for MRU field is 0-32767, default value is 1492.

MTU: Maximum Transmission Unit (MTU) is the largest size packet that can be sent by the modem. If the network stack of any packet is larger than the MTU value, then the packet will be fragmented before the transmission. During the PPP negotiation, the peer of the PPP connection will indicate its MRU and will accept any value up to that size.

The actual MTU of the PPP connection will be set to the smaller of the two (MTU and the peer’s MRU).

Range for MTU field is 0-32767, default value is 1492.

MSS: Maximum Segment Size is the largest size of data that TCP will send in a single, unfragmented IP packet. The LAN client and the WAN host will indicate their MSS during the TCP connection handshake.

Range for MSS field is 0-32767, default value is 1432.

Authentication: The different types of available authentications are:

• Auto: When auto is selected, PAP mode will run by default. However, if PAP fails, then CHAP will run as the secondary protocol. This is the default setting.

• PAP: Password Authentication Procedure. Authentication is done through username and password.

• CHAP: Challenge-Handshake Authentication Protocol. Typically more secure than PAP, CHAP uses username and password in combination with a randomly generated challenge

(21)

- 18 - 6.2 LAN & DHCP Configuration

This page let you configure your Local Area Network and DHCP server.

Figure 6-2 LAN & DHCP Configuration To setup the LAN and DHCP settings, please do the following:

1. LAN Setting (Router Configuration): This is where you assign a local IP address to your router. The factory default value is 10.0.0.99 with a subnet mask of 255.255.255.0.

(Note: When you change the LAN Setting of the Router, you need to reset/renew the Local computer IP address.)

2. Enable DHCP Server: Tick to enable DHCP (Dynamic Host Configuration Protocol). When enabled, router will provide IP address to the computers connected to the router.

3. DHCP address pool selection, System Allocated: If this is selected, router will assigns IP address automatically from 10.0.0.4 to 10.0.0.15.

4. DHCP address pool selection, User Defined: If this is selected, router will assigns IP address automatically from the DHCP address pool (For User Defined only). User can set up to 253 IP addresses in the address pool.

(22)

- 19 -

User Defined Start Address: This is the starting IP address of the DHCP pool for User Defined DHCP Address Pool Selection.

Range for User Defined Start Address is x.x.x.x, where 0 ≤ x≤ 255, default value is 10.0.0.4.

User Defined End Address: This is the last IP address in the DHCP pool. User Defined DHCP Address Pool Selection.

Range for User Defined End Address is x.x.x.x, where 0 ≤ x≤ 255, default value is 10.0.0.15.

DHCP Gateway Selection: The default setting for the DHCP Gateway Selection is Automatic. You can select User Defined and specify User Defined Gateway Address. The DHCP server will issue the User Defined Gateway Address to the LAN DHCP clients. User Defined Gateway Address: The purpose for the User Defined Gateway Address is to have two gateway addresses, as the LAN IP Address at the top of the LAN

Configuration page is also a gateway address.

Lease time: The Lease time is the amount of time a network user will be allowed to connect with DHCP server. If all fields are 0, the allocated IP addresses will be effective forever.

Ranges for Lease Time fields: Days 0-36500, Hours 0-23, Minutes 0-59, Seconds 0- 59, default value is 1 days 0 hours 0 minutes 0 seconds

DHCP Relay: If it is enabled, the DHCP requests from local PCs will forward to the DHCP server runs on WAN side. To have this function working properly, please disable the NAT to run on router mode only, disable the DHCP server on the LAN port, and make sure the routing table has the correct routing entry.

DHCP Relay Target IP: If DHCP Relay is enabled, DHCP requests are relayed to DHCP Target IP on the WAN side.

(23)

- 20 - 6.3 NAT Configuration

The NAT Configuration page allows you to set the configuration for the Network Address Translation. The NAT module provides Dynamic Network Address and Port Translation (Dynamic NAPT) capability between LAN and multiple WAN connections, and the LAN traffic is routed to appropriate WAN connections based on the destination IP addresses and the Route Table. This eliminates the need for the static NAT session configuration between multiple LAN clients and multiple WAN connections. When Dynamic NAPT is chosen (default), there is no need to configure the NAT Session and NAT Session Name Configuration.

(24)

- 21 -

Figure 6-4 Advanced NAT Configuration

Session Name: This field allows you to enter a Session Name to help distinguish different NAT Sessions for different interfaces among different PPP sessions and PVCs. The Session Name can be up to 31 characters, and there can be up to 16 different NAT session names. Interface: This field allows you to choose specific WAN Interfaces (PVC or PPP Session) for NAT Session. The options for this field are PVC0 ... PVC7 and any PPP session that was created by the user.

NAT Session Name Status: This table is displayed at the bottom of this page to show all the NAT Session Names with their corresponding WAN Interfaces.

Number of NAT Configurations: This field displays the total number of NAT Sessions entered.

Note: NAT allows only one entry (User IP) per session, while NAPT allows many entries (User IPs) per session.

NAT: Use this field to Enable/Disable NAT. Default is Enable. Mode: Options for the NAT dropdown menu are:

• NAT: Static peer-to-peer mode (1x1).

• NAPT: Static multiple mapping mode (1xN).

• Dynamic NAPT: Dynamic multiple mapping mode (NxN). This is the default setting. Session Name: This field allows you to select the session from the configured NAT Session Name Configuration.

(25)

- 22 -

User’s IP: This field allows you to assign the IP address to map the corresponding NAT/NAPT sessions.

Session Name Status: This table will be displayed at the middle of the page to show the Session Name with its corresponding IP Address.

Number of NAT Configurations: This field displays the total number of NAT Sessions entered.

Available Sessions: This table will be displayed at the bottom of the page to show all the available Session Names with their corresponding WAN Interface.

Number of Sessions: This field displays the total number of NAT Sessions entered.

6.4 Port Forwarding Configuration

This features are used for port forwarding from the WAN to LAN networks.

The Port Forwarding Configuration page allows you to set the configuration of the Virtual Server. All UDP/TCP ports are protected from intrusion. If any specific local PCs need to be mapped to the UDP/TCP port on WAN side, please input the mappings here.

There can be up to 20 different Port Forwarding Configurations.

Figure 6-5 Port Forwarding Configuration

ID: This is the ID number corresponding to the Virtual Server configuration.

Public Port - Start: This field allows you to enter the port number of the Public Network (WAN or external network). If you are entering a range of ports, this is the first port.

Public Port - End: This field represents the last port number in a port range. If you only want one port number (no port range), simply enter the same number here as in the

(26)

- 23 - Public Port – Start field.

The maximum number of the mapped Port is 20.

Private Port: This field allows you to enter the port number of the Private Network (LAN or internal network). In most cases, the private port number is same as public port number. This port number cannot be seen from the WAN side.

Host IP Address: This field allows you to enter the private network IP address for the particular server.

6.5 Bridge Filtering

Bridge Filtering allows packets to be forwarded or blocked, depending on the MAC address. This page let you configure MAC filtering. There can be up to 4 different Bridge Filtering configurations.

Figure 6-6 Bride Filtering

Bridge Filtering allows packets to be forwarded or blocked, depending on the MAC address. The Bridge Filtering configuration page allows you to set the configuration of MAC filtering.

There can be up to 4 different Bridge Filtering configurations.

Source MAC: This is the Source MAC to block or from which to forward. See the next page for instructions on how to configure this. The Source MAC must consist of 12 hexadecimal characters.

Destination MAC: This is the Destination MAC to block or to forward to. See the next page for instructions on how to configure this. The Destination MAC must consist of 12 hexadecimal characters.

(27)

- 24 -

Type: Enter the hexadecimal number for the Ethernet type field in Ethernet II packets. For example, 0800 is for IP protocol. The Type must consist of 4 hexadecimal characters. Block: When block is selected, everything from the Source MAC with destination Destination MAC will be blocked.

Forward: When forward is selected, everything from the Source MAC will be forwarded to the Destination MAC.

Q1: How do I forward packets with MAC address 000002fa6fab to destination MAC 000003dc8faa through IP protocol?

A: First go to the Bridge Filtering page under Configuration. Then type 000002fa6fab in the ID Source MAC field, 000003dc8faa in the Destination MAC field, and 0800 in the Type field. If bridge filtering is not already enabled, select Yes under the Enable Bridge Filtering field. Then select Forward and click Submit.

Q2: How do I block packets from MAC address 000002fa6fab through IP protocol?

A: First go to the Bridge Filtering page under Configuration. Then type 000002fa6fab in the ID Source MAC field and 0800 in the Type field. If bridge filtering is not already enabled, select Yes under the Enable Bridge Filtering field. Then select Block and click Submit.

Q3: How do I block incoming packets with destination MAC address 000003dc8faa through IP protocol?

A: First go to the Bridge Filtering page under Configuration. Then type 000003dc8faa in the Destination MAC field, and 0800 in the Type field. If bridge filtering is not already enabled, select Yes under the Enable Bridge Filtering field. Then select Block and click Submit.

6.6 DNS Configuration

The DNS Configuration page allows you to set the configuration of the DNS proxy. For the DHCP requests from local PCs, the DHCP server will set the LAN port IP as the default DNS server. Thus, all DNS query messages will come into LAN port first. The DNS proxy on the ADSL Bridge/Router records the available DNS servers and forwards DNS query messages to one of DNS servers.

(28)

- 25 -

Figure 6-7 DNS Configuration

DNS Proxy Enable/Disable: When the DNS Proxy is Disabled, the LAN port does not process the DNS query message. For the DHCP requests from local PCs, the DHCP server will set the user-configured DNS server as the DNS server. Then all DNS query messages will be directly sent to the DNS servers. DNS Proxy is enabled by default.

Auto Discovered: When enabled (default), the DNS proxy will store the DNS server IP addresses obtained from DHCP client or PPP into the table. All DNS query messages will be sent to the dynamically obtained DNS server. Select this option when the DNS Server address is unknown but provided (automatically) by the ISP.

User Configured: When enabled, the DNS proxy will use the user-configured DNS server. All DNS query messages will be sent to the DNS server. Enter the DNS IP in the DNS Server field. Select this option when the DNS Server address assigned by the ISP is known. User Configured is disabled by default.

DNS Server: This is the user defined DNS server URL name and IP. Default is Disabled. • URL Name (Add/Delete): This is the URL name for the DNS server. This can be up

to 255 characters.

• Host IP (Add Only): This is the IP address of the DNS Server. DNS Proxy Setting: This is a table of all DNS server IP addresses. DNS Server Setting: This is a table of all DNS sever URL names.

Save Configuration: Clicking this will link the user to the Save Settings / Reboot page.

6.7 Save Settings / Reboot

(29)

- 26 -

Figure 6-8 Save Settings / Reboot Save & Reboot: Click this to apply all changes.

Reboot Only: Do this to discard all changes since last save. After either one of these buttons are clicked, the ADSL Bridge/Router will do the following:

• Save & Reboot: Two pages will appear after pressing this button. The first one states: “Your settings are being saved and the modem being rebooted. Save reboot in progress, please wait….” Followed by “Your settings have been saved and the modem has rebooted. Done”

Figure 6-9 Save Settings

Reboot Only: Two pages will appear after pressing this button. The first one states: “The V300ATA is being rebooted. Reboot in progress, please wait….” Followed by “The modem is being rebooted. Done.”

(30)

- 27 -

7. Advanced Mode

It provides a brief outline of the advanced features of individual hyper links on the left menu.

Figure 7-1 Advanced Mode 7.1 ATA Configuration

The ATA Configuration page allows you to set different parameters of the VoIP application.

(31)

- 28 -

Version details: This section displays the current version of ATA application and the PTM module.

Service Provider To Use: This parameter holds the service provider selected to work with the ATA for the above chosen Line. Different service provider specific details can be configured by clicking the link Update Service Provider. When a different service provider is chosen from the Drop-down list, the Login Account To Use drop-down list is updated to reflect the login details available and configured for the selected service provider.

Login Account To Use: This parameter holds the Login Account selected to work with the ATA for the above chosen Line and the Service Provider. Different Login Account details can be configured by clicking the link Update User Login Account. This permits multiple logins to be created per service provider. Further, SIP protocol also allows the same login to be used for registration from multiple locations. So the same login under the same service provider can be used from multiple lines.

Current Registration Status: This field displays the current registration status of this line. If the line is registered it shows the status as REGISTERED else it shows UNREGISTERED. Dial Tone is NOT played when WAN interface is DOWN or REGISTRATION is FAILED.

7.2 SIP Service Provider Configuration

7.2.1 SIP Service Provider

The ATA SIP Service Provider Configuration page allows the user to set the configuration related to the SIP service provider.

(32)

- 29 -

Service Provider List: This selection is a drop-down box, which allows the user to select the Service Provider for which the configuration needs to be done. When a service provider is selected from this dynamic list, the respective parameters are automatically displayed.

A DEFAULT set of parameters is provided for every new service provider added. This can be edited accordingly. New service providers can be defined and added manually by the user. An existing service provider can be edited or even deleted.

New Service Provider: New Service Provider is a text-field where the user can enter the name of the new service provider to be added, or a new string to rename an existing service provider. The service provider edited will be the one chosen from the Working Service Provider field.

Registration Interval: This parameter specifies the re-registration interval in seconds.

Registrar Address: This parameter gives the IP address of the registrar with which the ATA must register in order to receive incoming calls.

Proxy Address: This parameter is the IP address of the SIP proxy server.

OutboundProxy Address: This parameter is the IP address of the Outbound proxy server. This is useful in cases where the ATA is behind a NAT.

Authentication Method: This parameter indicates the authentication method. Currently, only MD5 is supported.

• AUTH_NONE: Disable any authentication method • AUTH_MD5: Use MD5 authentication method.

Registrar Port: This parameter informs the port of the registrar on which it will listen for Register requests from the ATA. (5000-65535)

Note: Range for Registrar port address is between 5000 and 65535. The default port is 5060.

Proxy Port: This parameter is the port on which the SIP proxy server will listen for messages.

OutboundProxy Port: This parameter is the port on which the outbound proxy server listens for messages from the ATA.

Service Provider Action: The ATA provides a drop-down option (Display, Add, or Edit or Delete) for the user to manipulate the various SIP and dial plan parameters for working service provider. Parameters for a service provider can be displayed, added, and edited.

• Display: This is the default option; selection of this option will display the selected service provider in the Working Service Provider field after clicking on the Submit button.

(33)

- 30 -

• Add: Selection of the Add option adds a new service provider after clicking on the Submit button according to the value that appears in the Working Service Provider field (which must not be empty).

• Edit: Selection of edit option will overwrite the selected service provider’s (according the Working Service provider field) parameters with the current parameters displayed on the web page. The New Service Provider field is optional and it needs to be filled only when the service provider name also has to be changed. • Delete: Selection of Delete option will delete the selected Working Service

Provider from the Service Provider list.

7.3 ATA Login Account Configuration

The ATA Login Account Configuration page allows the user to set and configure login accounts for the service provider chosen in the index webpage, i.e., for the currently selected service provider in the main webpage.

Figure 7-4 ATA Login Account Configuration

User Profile List: This selection is a drop-down box, which allows the user to select the login account for which the configuration needs to be done. When a login account is selected from this dynamic list, the respective parameters are automatically displayed. A DEFAULT set of parameters is provided for every new login added. This can be edited accordingly. New logins can be defined and added manually by the user. An existing login account can also be edited or even deleted.

(34)

- 31 -

New User Name: New User Name is a text-field where the user can enter the name of the new login account to be added, or a new string to rename an existing login account. The login account edited will be the one chosen from the Service Provider List field.

User Name: This parameter holds the registration Id of the user with the registrar. Password: This parameter holds the Password used for authentication with the registrar. Display Name: This parameter holds the Display Name, as it should appear on the Caller-Id. Login Action: The ATA provides a drop-down option (Display, Add, or Edit or Delete) for the user to manipulate the various login parameters for login account chosen in the Login Account List. Parameters for a login account can be displayed, added, and edited.

• Display: This is the default option; selection of this option will display the selected login details after clicking on the Submit button.

• Add: Selection of the Add option adds a new login account after clicking on the Submit button according to the value that appears in the New Account Name field (which must not be empty).

• Edit: Selection of edit option will overwrite the selected login’s (in the Login List field) parameters with the current parameters displayed on the web page. The New Login field is optional and it needs to be filled only when the login account name also has to be changed.

• Delete: Selection of Delete option will delete the selected Login Account from the Login Account List.

Submit Changes: Clicking on this button will save settings to the board RAM. In order to save changes permanently to the firmware and to make them effective, the setting should be saved by going to the Save Settings/Reboot web.

Note: The above parameters are Service Provider specific and are reflected for the Service Provider that was shown as selected in the ATA index webpage before arriving through the link Update User Login Account Configuration.

Note: The maximum number of login accounts you can add is 4 per service provider and there must be at least 1 login account per service provider available.

(35)

- 32 - 7.4 ATA Timer Configuration

The ATA Timer Configuration page provides a number of timers used at the system level, which can be configured through the web interface. The timer values have to be given in seconds only. This section explains the various timers available for configuration.

Figure 7-5 ATA Timer Configuration

Predial Timeout: dial timer indicates the time period through which the dial tone is heard once the phone has been lifted off the hook. At the end of this period, if no digits have been pressed, the ATA will start playing the fast-busy tone.

Alert Timeout: Alert Timer indicates the time for which the ATA will play the Ring when an incoming call has arrived and the phone is on-hook. After this timer period the ATA will automatically stop the ring and reject the call.

Disconnect Timeout: Disconnect Timer indicates the time for which the fast-busy tone is played once a call has been disconnected by the remote-end. At the end of this time, the Warble tone will be played until the user hangs up the phone.

RingBack Timeout: RingBack Timer indicates the time period for which the ATA will wait while the RingBack tone is being played for the final response from the other end point once an outgoing call has been made and the initial response has been received.

Call Progress Timeout: CallProgress Timer indicates the time period for which the ATA will wait for the initial response from the other end point once an outgoing call has been made.

Call Waiting Timeout: CallWaiting Timer indicates the period for which the call-waiting tone will be played when an incoming call arrives in the connected state. The Call Waiting tone is played at an interval of 10 sec. It is configurable using the Call Waiting tone parameters.

(36)

- 33 -

Call Fwd No Ans Timeout: CallFwdNoAns Timer indicates the time after which the call will be forwarded when not answered by anyone. This timer is applicable when Call Forwarding on No Answer is enabled.

Submit Changes: Clicking on this button will save settings to the board RAM. In order to save changes permanently to the firmware and to make them effective, the setting must be saved by going to the Save Settings/Reboot web page

7.5 Country Specific Ring & Tones Configuration

The Country Specific Ring & Tones Configuration page is used to define the parameters for the various tones (ring, dial, busy, ring back etc.) that are generated by the ATA application.

ATA provides default Ring-Tone Parameters configured for various Countries. Flexibility is provided to change the existing ring-tone parameters and add new countries and also edit/delete existing countries.

Figure 7-6 Country Specific Ring & Tones

Working Country: This selection is a drop-down box, which allows the user to select the country for which the ATA configuration must work. Currently, it is applicable for the ring-tone parameters only. When a country is selected from this dynamic list, the country parameters are automatically displayed.

(37)

- 34 - · USA, Singapore, Hong Kong,Australia

New countries can be defined and added manually by the user.

New Country: New Country is a text-field where the user can enter the country name to be added or a new string to edit an existing country. The country edited will be the one chosen from the Working Country field

Ring Parameters: The Ring Parameters are defined by five fields: Frequency, OnTime1, OffTime1, OnTime2, and OffTime2. Time values are in milliseconds. Frequency is given in hertz.

Normal Dial Tone: The dial tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

RingBack tone: The ring back tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

Alerting Tone: The alerting tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

Recall Tone: The recall tone parameters are defined by five fields: Freq1, Freq2, OnTime1, OffTime1 and Duration.

Busy Tone: The busy tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

Call waiting tone: The call waiting tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

Congestion Tone: The congestion tone parameters are defined by six fields: Freq1, Freq2, OnTime1, OffTime1, OnTime2, and OffTime2.

Stutter Dial Tone: The stutter dial tone parameters are defined by five fields: Freq1, Freq2, OnTime1, OffTime1 and Duration.

VMI Dial Tone: The stutter dial tone parameters are defined by five fields: Freq1, Freq2, OnTime1, OffTime1 and stutter Duration. This plays a distinctive stutter dial tone on Off Hook when there are Voice Mails waiting on the phone.

Ring Tone Action: The ATA provides a drop-down option (Display, Add, or Edit or Delete) for the user to manipulate the ring-tone parameters for the working country. Ring-tone parameters for a country can be displayed, added, and edited.

• Display: This is the default option. Selection of this option will display the selected country in the Working Country field after clicking on the Submit button.

(38)

- 35 -

• Add: Selection of the Add option adds a new country after clicking on the Submit button according to the value that appears in the Working Country field. This field must not be empty.

• Edit: Selection of edit option will overwrite the selected country’s (according the Working Country field) parameters with the current parameters displayed on the web page. The New Country field is optional and needs to be filled only when the country name also has to be changed.

• Delete: Selection of the Delete option will delete the selected Working Country from the country list.

Submit Changes: Clicking on this button will save settings to the board RAM. In order to save changes permanently to the firmware and to make them effective, the setting should be saved by going to the Save Settings/Reboot web page

7.6 ATA Misc Configuration

(39)

- 36 -

• Local SIP Port: Provides the local SIP port on which ATA should listen for messages. It is indicated through this parameter.

Note: Range for Local SIP Port is between 1 and 65535. The default port is 5060. • Media Base Port: Also known as RTP port, this parameter provides the base value

from the media (RTP) ports that are assigned for various lines and the different call sessions that may exist within an end-point.

Note: Range for Media Base Port is between 5000 and 65535. The default port is 5000.

STUN Support Parameters: This section allows the user to configure for STUN supporting in the ATA.

• STUN Enable: This radio buttons determine if the ATA applications will use STUN for NAT traversal.

Yes: Use STUN. Enable STUN if the ATA is behind a NAT enabled rouer and the router has no ALG for SIP. Please note that STUN does not support Symmetric NATs.

No: This is the default. Do not use STUN

• STUN Server Address: This pareameter is the IP address or Domain Name of the STUN Server.

• STUN Server Port: This parameter allows the user to specify the port number on which the STUN server listens for requests from the STUN Client on ATA. The default is 3478

Codec Preference: The Codec Preference determines the order with which all supported codecs shall be placed in a call setup message sent to any destination line. It will also help determine the Selected Codec when a message indication for an incoming call is received from the Remote end with codec preference information.

• G711U: This parameter holds the priority to be assigned to G711U codec. (1-3). 1: Priority 1.

2: Priority 2. 3: Priority 3.

• G711A: This parameter holds the priority to be assigned to G711A codec. (1-3). 1: Priority 1.

2: Priority 2. 3: Priority 3.

• G729A: This parameter holds the priority to be assigned to G729A codec. (1-3). 1: Priority 1.

(40)

- 37 - 3: Priority 3.

Note: Codec priority is selected using a drop-down box. If two codec types are assigned the same priority, then the priority is assigned in the order as G729> G711A > G711U in the decreasing order of priority. For example, if the user selects 1, 2, 2, for G711U, G711A, and G729A respectively, the application will assign priority as 1, 2, and 3 for G711U, G711A, and G729A respectively.

Submit Changes: Clicking on this button will save settings to the board RAM. In order to save changes permanently to the firmware and to make them effective, the setting should be saved by going to the Save Settings/Reboot web page

(41)

- 38 -

8. Admin Privilege

8.1 Route Table

The Route Table page displays the routing table and allows you to manually enter a routing entry. The routing table will display the routing status of Destination, Netmask, Gateway, and Interface. The interface lo0 indicates the loop back interface; ppp1 indicates the PPP interface. The Gateway is the learned Gateway

Figure 8-1 Route Table

System Default Gateway Configuration: The system Default Gateway now provides four options: None, Auto, Select Interface and Specify IP.

None: This field allows the user to choose to have no Default Gateway in the router. Auto: This field allows the user to select the router to automatically decide the

Default Gateway. (System Default)

Select Interface: This field allows user to select a Network Interface from a list. This option lets the user to associate the system default gateway to a network interface, static or dynamic, and provides a way to fix the Default Gateway to a dynamic Network Interface before the interface is established.

(42)

- 39 - 8.1.2 Route Configuration

Figure 8-2 Route Configuration

Destination: This field allows the user to enter the remote network or host IP address for the static routing.

Netmask: This field allows the user to enter the subnet mask for the static routing. Gateway: This field allows the user to enter the IP address of the gateway device that

allows the router to contact the remote network or the host for Specified IP or select an Interface for the Gateway.

Manually Configured Routes: This field displays the static route entries by the user. Ensure to click Submit and Save Settings for your configuration to take effect.

Route Configuration

Destination: This field allows you to enter the remote network or host IP address for the static routing.

Netmask: This field allows you to enter the Subnet Mask for the static routing.

Gateway: This field allows you to enter the IP address of the gateway device that allows the router to contact the remote network or the host for Specified IP or select an Interface for the Gateway.

Manually Configured Routes: This field displays the static route entries entered by the user.

(43)

- 40 - 8.2 Bridge MAC Table

Network bridges operate at the physical network layer. The purpose of a bridge is to connect two or more networks and enable packet sharing between them. Bridges are different from routers because they forward packets based on physical addresses, whereas routers use IP address to forward packets. Bridges must learn all the physical (MAC) addresses of the devices so it can forward the packets reliably. The purpose of the Learned MAC Table is to store and display these bridge-recognized MAC addresses. The Learned MAC Table page shows the current learned Bridge MAC table. This page contains information that is dynamic and will refresh every 8 seconds.

Figure 8-3 Bridge MAC Table

Aging Timeout: This field allows you to enter the update period for the MAC table. Have this number lower if you want a more frequent refresh rate.

Range for Aging Timeout field is 0 – 32767, default is 100.

8.3 RIP System Wide Configuration

RIP (Routing Information Protocol) is a management protocol that ensures that all hosts in a particular network share the same information about routing paths. In a RIP, a host computer will send its entire routing table to another host computer every X seconds, where X is the supply interval. The receiving host computer will in turn repeat the same process by sending the same information to another host computer. The process is repeated until all host computers in a given network share the same routing knowledge.

There are several components to RIP, including the authenticator, supplier, and listener. Authenticator: Authentication is only available for RIPv2. When it is disabled, RIPv2 messages containing authentication entries are discarded. When it is enabled, all RIPv2 messages must have proper authentication entries, and all RIPv2 messages without verified authentication entries and all RIPv1 messages are automatically rejected.

(44)

- 41 - Supplier: The RIP Supplier has two functions:

• It transmits route updates over every RIP Supplier interface at the interval specified by Supply Interval (see below).

• It transmits route updates in response to specific requests from other routers.

Listener: The RIP Listener listens and processes all RIP messages it receives from other RIP routers and updates the host routing tables accordingly. The RIP Listener is always enabled when RIP is enabled. By default, RIP is disabled.

The announcement messages RIP sends are based on two configuration parameters: RIP Version number and Multicast:

Figure 8-4 RIP System Wide Configuration Version Multicast Announcements Sent

1 OFF V1

2 ON V1

2 OFF V2-BC

2 ON V2-MC

The RIP messages that can be received and processed are based on two configuration parameters: RIP Version number and Multicast :

Version Multicast Announcements Sent

1 OFF V1

2 ON V1

2 OFF V2-BC

(45)

- 42 -

RIP: This field allows you to Enable or Disable the RIP session. The resulting RIP session will monitor all network interfaces that are currently available for messages from other RIP routers. RIP is disabled by default.

Border Gateway: RIP implements Border Gateway as specified in RFC 1058 and RFC 1723. This limits all subnet routes and host routes to routers within that same network. Updates sent outside that network will only include a single entry representing the entire network, including all subnets and host-specific routes. The Border Gateway is enabled by default.

Supplier Interval: This field allows you to enter the Supplier Interval timer in seconds. This timer specifies how often the RIP sends announcements as a RIP Supplier.

Range for Supplier Interval field is 0 – 2147483647, default value is 30.

Expire Timeout: This field allows you to enter the Expire Timeout in seconds. This timer specifies the expiration time of a route. When a route has not been updated for more than the “expire” period of time, it is removed from the Route Table. This route isthen invalidated and remains in the internal RIP Route Table. It will be included in the RIP announcements to let other routers know the changes.

Range for Expire Timeout field is 0 – 2147483647, default is 180.

Garbage Timeout: This field allows you to enter the Garbage timer in seconds. This timer specifies how long the expired and invalidated routes are kept in the Internal RIP Route Table before they are removed from it.

Range for Garbage Timeout field is 0 – 2147483647, default is 120.

(46)

- 43 -

Interface: This field allows you to choose the Interface (PVCs, PPP Sessions, USB and LAN), for the RIP to be configured. The available selections are: IP Ethernet 0, IP USB 0, IP PVC0...IP PVC7, IP BridgeMux 0, and any PPP user defined sessions (maximum of 16): Enable: This field allows you to Enable (Yes) or Disable (No) the specified interface for RIP.

Supplier: This field allows you to select the Supplier Mode (RIP Transmit). • Disabled: The supplier transmit is disabled.

• V1 BC: The supplier transmits in RIPv1 Broadcast. • V2 BC: The supplier transmits in RIPv2 Broadcast. • V2 MC: The supplier transmits in RIPv2 Multicast.

Listener: This field allows you to select the Listener Mode (RIP Receive) • V1: The listener receives the RIPv1 only.

• V2: The listener receives the RIPv2 only.

• V1+V2: This listener receives the both RIPv1 and RIPv2.

Current RIP Settings: This field displays the each interface’s RIP status.

8.4 DMZ Configuration

The DMZ (De-Militarized Zone) Configuration page let you map a local computer to this zone. DMZ is added between a protected network and an external network, in order to provide an additional layer of security. When there is a suspected packet coming from WAN, the firewall will forward this packet to the DMZ host..

Figure 8-6 DMZ Configuration

DMZ: Select Enabled to enable DMZ or Select Disabled to disable DMZ.

DMZ Host IP: The IP address of the DMZ host viewable at the WAN (external) side. Ensure to click Apply and Save Settings for your configuration to take effect

(47)

- 44 -

8.5 SNTP Configuration

This page allows you to set the Simple Network Time Protocol.

Figure 8-7 SNTP Configuration

SNTP: Simple Network Time Protocol is a efficient method of obtaining the time from a Time Server.

Time Zone: This specifies the time zone (geographical location).

Daylight Saving Time: Select to enable or disable Daylight Saving Option.

User Defined Time Server: Specified the IP address of your preferred SNTP server

(Note: When the V300ATA is successfully connected to the SNTP server, the system log will reflect the updated time such as the example as shown below.)

(48)

- 45 - 8.6 Miscellaneous Configuration

This page allows you to configure the miscellaneous configurations such as HTTP, FTP, Command Line Interface, IGMP.

(49)

- 46 -

HTTP Server Access: This field allows you to configure where these Web pages can be accessed from.

• All: When this field is checked, it allows both WAN and LAN access to the Web pages. This is the system default.

• Restricted LAN: This field allows the Web pages access from LAN side.

• Restricted WAN Specified IP & Subnet Mask: This field allows the Web access from WAN side with a specify IP and subnet mask.

HTTP Server Port: This field allows you to specify the port of the Web access. . For example, when it is changed to 8080, the HTTP server address for the LAN side is

http://10.0.0.99:8080.

Range for HTTP Server port is 0 – 32767, default value is 80.

HTTP Password Protection: This field allows you to enable or disable the HTTP authentication, default is set to disable.

FTP server: This field allows you to enable or disable the FTP server connection. System default is Enabled.

• Disable WAN side FTP access: This will disable WAN side access to the FTP server, default is Disabled.

TFTP server: This field allows you to enable or disable the TFTP connection. System default is Disabled.

DHCP

• NONE: This will disable the DHCP server. Note that this setting will override the DHCP Server Enable/Disable on the LAN configuration page.

• DHCP Server (default): Select this to activate the DHCP server.

IGMP Proxy: This is the global setting for IGMP Proxy. If it is enabled, then the enabled IGMP Proxy on WAN PVCs will be working. Otherwise, no WAN PVC can have IGMP Proxy working on it. System default is Disabled.

PPP Half Bridge: When PPP Half Bridge is enabled, only one PC is able to access the Internet, and the DHCP server will duplicate the WAN IP address from the ISP to the local client PC. Only the PC with the WAN IP address can access the Internet. System default is Disabled.

PPP reconnect on WAN access: If enabled, the PPP session will automatically establish a connection when a packet tries to access the WAN. System default is Disabled.

Connect PPP when ADSL link is up: If this option is enabled, the bridge/router will connect the PPP session whenever an ADSL connection is established. If this option is disabled, the PPP session will not connect whenever the ADSL Showtime is reached. System default is Enabled.

(50)

- 47 - 8.7 Admin Username / Password Configuration

This page allows you to change password for the administrator.

Figure 8-10 Admin Username / Password Configuration

Enter the password in both of the text fields. Make sure that the password is at least 8 characters long and do not contain '&'. (note: Please ensure to enter password for FTP to work.)

Ensure to click Submit and Save Settings for your configuration to take effect.

8.8 Reset to Default

This page allows you to reset the ATA to original factory default configuration.

Figure 8-11 Restore Settings Click on Restore button to restore the settings.

(51)

- 48 - 8.9 Firmware Update

This page allows the user to upgrade the firmware via web interface.

Figure 8-12 Firmware Update

• Upon clicking the “Firmware Update” button, the V300ATA will perform a restart. The message as shown below will be displayed.

• After restarting, if you are not able to seen the screen below, please refresh your webpage.

Current firmware Version: This shows the current firmware version of the V300ATA. To upgrade the firmware:

• Enter the path of the file in the text box or click Browse to select the file. “Example: firmware.dlf ”

• Click Upload to start the upgrading process. • Please wait and do not turn off the router.

(Note: Do not upgrade the firmware unnecessarily.)

(52)

- 49 - 8.10 Save / Reboot

This page allows you to save the new configurations to the flash and reboot the ATA or simply reboot the ATA without saving changes.

Figure 8-12 Save / Reboot Save & Reboot: Click this to apply all changes.

Reboot Only: Do this to discard all changes since last save. After either one of these buttons are clicked, the ADSL Bridge/Router will do the following:

• Save & Reboot: Two pages will appear after pressing this button. The first one states: “Your settings are being saved and the modem being rebooted. Savereboot in progress, please wait….” Followed by “Your settings have been saved and the modem has rebooted. Done”

• Reboot Only: Two pages will appear after pressing this button. The first one states: “The modem is being rebooted. Reboot in progress, please wait….” Followed by “The modem is being rebooted. Done.”

References

Related documents

(b) Is there a change in endorsements on autobiographical memories between those participants self-reporting vulnerability or non-vulnerability and in those self-reporting

For Address, enter the gateway IP Address (directly connected device) for the destination network. This will be different for each similarly load shared route. For Interface,

In the Network Interface 0 screen, enter the IP address of the eth0 interface, the network facing interface of the LoadMaster, in the Interface Address input field.. Click on the

• A default IP address pool is created, named pool0, with the specified IP address range, the gateway, the optional SmartConnect zone name, and the initial external interface with

Enable Static Route in Route Setup of TCP/IP page and then enter IP Address of Network 3、Subnet Mask and IP Address of Router (R1) in Default Gateway field final click Apply

This page allows you to change network settings of the device including IP address, subnet mask, gateway IP address and SNMP information of GW51C- MAXI.. Please notice that any

Workshop on Strategic Executive Leadership International Bank of Qatar 5/20/2010 12/20/2010 Business & Management Training of Medical Services Director Qatar Petroleum

Headquarters IP Phones Router AudioCodes SAS Media Gateway Remote Office IP Phones Router AudioCodes SAS Media Gateway Service Provider IP network IP Centrex/IP-PBX AudioCodes