(1)

M/V “VSLNAME”

IMO No: 9999999

DAMAGE CONTROL

BOOKLET

(2)

TOTAL THIRTY (30) SHEETS WITH COVER

SAMPLE

(3)

TABLE OF CONTENTS

PAGE 1. SCOPE... 4 2. GENERAL PARTICULARS ... 5 2.1. GENERAL ... 5 2.2. PRINCIPAL DIMENSIONS... 5 2.3. FRAME SPACING... 5 3. GENERAL INSTRUCTIONS... 6

4. DAMAGE CONTROL PLAN INFORMATION ... 7

4.1. GENERAL ... 7

4.2. INTERNAL WATERTIGHT CLOSING APPLIANCES ... 9

4.3. EXTERNAL WATERTIGHT CLOSING APPLIANCES ... 11

4.4. WEATHERTIGHT CLOSING APPLIANCES... 12

4.5. NON-WATERTIGHT OPENINGS ... 16

4.6. NON-WEATHERTIGHT OPENINGS ... 16

5. ADDITIONAL INFORMATION... 17

5.1. SOUNDING DEVICES, TANK VENTS & OVERFLOWS ... 17

5.2. BILGE & BALLAST PUMPS... 17

5.3. INSTRUCTIONS FOR OPERATING CROSS-FLOODING SYSTEMS... 18

5.4. MEANS OF ACCESSING AND ESCAPING FROM WATERTIGHT COMPARTMENTS BELOW BHD DECK (UPPER DECK) ... 18

5.5. SOUNDING PIPES ... 21

5.6. TANK VENTS & OVERFLOWS WHICH DO NOT EXTEND ABOVE THE WEATHER DECK ... 21

5.7. DE-WATERING SYSTEM FOR FORE SPACES ... 21

5.8. WATER INGRESS DETECTION SYSTEM... 22

5.9. DAMAGE STABILITY CALCULATIONS SUMMARY ... 23

5.10. CONTACT PROCEDURES AND DETAILS IN THE EVENT OF DAMAGE... 26

APPENDIX

1. Damage Control & Watertight Integrity Plan

(4)

1. SCOPE

This Booklet has been prepared in accordance with MSC / Circ. 919 (Guidelines for Damage Control Plans). It is intended to provide the ship's officers with clear information on the ship's watertight compartmentation and equipment related to maintaining the boundaries and effectiveness of the compartmentation so that, in the event of damage to the ship causing flooding, proper precautions can be taken to prevent progressive flooding through openings therein and effective action can be taken quickly to mitigate and, where possible, recover the ship's loss of stability.

(5)

2. GENERAL

PARTICULARS

2.1. GENERAL

Ship’s Name: VSLNAME

Ship’s Type: Flag: Port of Registry: Call Sign: IMO Number: 9999999 Classification: Built by: Year Built: Complement: 2.2. PRINCIPAL DIMENSIONS Length O.A.: Length B.P.: Breadth (mld.):

Depth to Main Deck (mld.): Summer Load Draught (extr.): Freeboard Type:

2.3. FRAME SPACING

A.E. – Frame 16: Frame 16 – 61: Frame 61 – 107:

(6)

3. GENERAL

INSTRUCTIONS

(7)

4. DAMAGE CONTROL PLAN INFORMATION

4.1. GENERAL

COMPARTMENT BOUNDARIES

(8)

COMPARTMENT BOUNDARIES

(9)

4.2. INTERNAL WATERTIGHT CLOSING APPLIANCES NO. LOCATION CLEAR OPENING [mmxmm] DESCRIPTION

SAMPLE

(10)

NO. LOCATION CLEAR OPENING [mmxmm] DESCRIPTION

SAMPLE

(11)

4.3. EXTERNAL WATERTIGHT CLOSING APPLIANCES

NO. QUAN.

CLEAR OPENING

[mmxmm]

LOCATION DESCRIPTION / TYPE / MATERIAL

(12)

4.4. WEATHERTIGHT CLOSING APPLIANCES a) Hatches NO. QUAN. CLEAR OPENING [mmxmm]

LOCATION DESCRIPTION / TYPE / MATERIAL

(13)

b) Doorways

NO. QUAN.

CLEAR OPENING

[mmxmm]

LOCATION DESCRIPTION / TYPE / MATERIAL

(14)

c) Air Pipes

NO. QUAN.

NOMINAL DIAMETER

[mm]

LOCATION DESCRIPTION / TYPE /

MATERIAL

(15)

d) Ventilation Openings

NO. QUAN.

NOMINAL DIAMETER

[mm]

LOCATION DESCRIPTION / TYPE /

MATERIAL

(16)

4.5. NON-WATERTIGHT OPENINGS

NO. QUAN.

CLEAR OPENING

[mmxmm]

LOCATION DESCRIPTION / TYPE /

MATERIAL 4.6. NON-WEATHERTIGHT OPENINGS NO. QUAN. CLEAR OPENING [mmxmm]

LOCATION DESCRIPTION / TYPE /

MATERIAL

SAMPLE

(17)

5. ADDITIONAL

INFORMATION

5.1. SOUNDING DEVICES, TANK VENTS & OVERFLOWS

5.2. BILGE & BALLAST PUMPS

NO. LOCATION DESCRIPTION CAPACITY

(18)

5.3. INSTRUCTIONS FOR OPERATING CROSS-FLOODING SYSTEMS

5.4. MEANS OF ACCESSING AND ESCAPING FROM WATERTIGHT COMPARTMENTS BELOW BHD DECK (UPPER DECK)

No.1 Void Tank (C):

NO. LOCATION DESCRIPTION

01

02

03, 04

05, 06

No.2 Void Tank (C):

NO. LOCATION DESCRIPTION

01

02

(19)

No.3 Void Tank (C):

NO. LOCATION DESCRIPTION

01

02

03, 04

05, 06

No.4 Void Tank (C):

NO. LOCATION DESCRIPTION

01

02

03, 04

05, 06

No.5 Void Tank (C):

NO. LOCATION DESCRIPTION

01

(20)

No.6 Void Tank (C):

NO. LOCATION DESCRIPTION

01

02

03, 04

05, 06

Engine Room:

NO. LOCATION DESCRIPTION

01 02 03 04 05 06 07

SAMPLE

(21)

5.5. SOUNDING PIPES

5.6. TANK VENTS & OVERFLOWS WHICH DO NOT EXTEND ABOVE THE WEATHER DECK

5.7. DE-WATERING SYSTEM FOR FORE SPACES

(22)

5.8. WATER INGRESS DETECTION SYSTEM

(23)

5.9. DAMAGE STABILITY CALCULATIONS SUMMARY

DAMAGE CASES:

(24)

(25)

---

INITIAL CONDITION LLCON Dmid = m Trim = m Disp = MT Trim is Positive By Stern VCG = m GM = m

---

Damage Stage Dmid Trim Heel FRB MaxGZ ARea PosRange VCG GM Critical VCGreq GMreq Range Range

Case (m) (m) deg (m) (m) m*rad (deg) (m) (m) Criterio (m) (m)

INTACT CRITICAL VCGreq GMreq Draft Mid Trim Damage Case (m) (m) (m) (m)

(26)

5.10. CONTACT PROCEDURES AND DETAILS IN THE EVENT OF DAMAGE

In the event of damage, the Master should alert the relevant parties, as appropriate, according to the lists below:

LIST OF SHIP INTEREST CONTACTS

Owners - Operators: Address: Telephone: Facsimile: Administration: Address: Telephone: Facsimile: Classification Address: Telephone: Facsimile:

SAMPLE

(27)

LIST OF SHIP MANAGEMENT INTEREST CONTACTS

POSITION NAME TELEPHONE MOBILE

(28)

APPENDIX

References

Related documents