• No results found

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

N/A
N/A
Protected

Academic year: 2021

Share "Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2"

Copied!
15
0
0

Loading.... (view fulltext now)

Full text

(1)

Tipos de Máquinas

 X550M2

1. Overview - 7946 x3550 M2

IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized, multiprocessor server system. The x3550M2 is scalable in cost, configuration, performance and availability. The two dual-core and quad-core processor sockets, DDR3 memory technology (with Chipkill support), memory mirroring, Standard Serial Attached SCSI (SAS) host controller, embedded two 1Gig-bit Ethernet controllers, PCI Express Gen2 slots, hot swap redundant power supplies, Integrated Management Module – (IMM) & hot swap fans provide redundant and high availability features.

Fig 1 - IBM System x3550 M2

Features

Microprocessor:

Supports up to two Intel® Xeon™ microprocessors (one installed), dual-core (two cores per microprocessor with 4 MB shared among cores) or quad-core (four cores per microprocessor with 8 MB shared among cores)

Level-2 cache

QuickPath Interconnect (QPI) links speed up to 6.4 GT per second

Support for Intel Extended Memory 64 Technology (EM64T) Note:

Use the Setup utility program to determine the type and speed of the microprocessors.

For a list of supported microprocessors, see

http://www.ibm.com/servers/eserver/serverproven/compat/us/ .

Memory:

Sixteen DIMM connectors (eight per microprocessor)

Minimum: 1 GB per microprocessor

Maximum: 128 GB with two processors installed (when 8 GB DIMMS are available)

Type: PC3-10600R-999 (single-rank or dual-rank), 800, 1067, and 1333 MHz, ECC, DDR3 registered SDRAM DIMMs only

(2)

Sizes: 1 GB, 2 GB, 4 GB, and 8 GB (when available) DIMMs SATA optical drives (depending on your model):

CD-RW/DVD-ROM combo (on standard models)

DVD-ROM (optional)

Multi-burner (optional)

Hard disk drive expansion bays (depending on the model):

Six 2.5-inch hot-swap SAS or hot-swap SATA hard disk drive bays

PCI Expansion Slots Supports two PCI riser slots:

Slot 1 supports low-profile cards (PCI Express Gen2 x16 or PCI-X 1.0a 64- bit/133 MHz).

Slot 2 supports half-length, full-height cards (PCI Express Gen2 x16 or PCI-X 1.0a 64-bit/133 MHz).

Hot-swap Power supplies:

One power supply standard

Maximum of two 675-watt ac (110 or 220 V ac auto-sensing) hot-swap power supplies for redundancy support

Hot-swap fans:

Six dual motor hot-swap fans (40 x 40 x 56 mm) Dimensions x3550 (7946)- 1U

Height: 43 mm (1.69 inches)

Depth: 711 mm (28 inches)

Width: 440 mm (17.3 inches)

Maximum weight: 15.4 kg (34 lb) when fully configured Integrated functions:

Integrated Management Module (IMM), which provides service processor control and monitoring functions, video controller, and (when the optional virtual media key is installed) remote keyboard, video, mouse, and remote hard disk drive capabilities

Dedicated or shared management network connections

Five Universal Serial Bus (USB) 2.0 ports (two front and two rear of the chassis, and one on the SAS/SATA RAID riser card in which the optional USB Flash device with embedded hypervisor software is installed)

(3)

Four Ethernet ports (two on system board and two additional ports when the optional IBM Dual-Port 1 Gb Ethernet Daughter Card is installed)

Broadcom BCM5709 Gb Ethernet controller with TCP/IP Offload Engine (TOE) and Wake on LAN® support. Jumbo frames (9KB) supported

One System Management RJ-45 on the rear to connect to a systems management network. This system management connector is dedicated to the IMM functions.

This connector is active with or without the optional IBM Virtual Media Key installed.

One serial port RAID controllers:

A ServeRAID-BR10i SAS/SATA adapter that provides RAID levels 0, 1, and 1E (comes standard on some hot-swap SAS and hot-swap SATA models).

An optional ServeRAID-MR10i SAS/SATA adapter that provides RAID levels 0, 1, 5, 6, 10, 50, and 60 can also be ordered.

Acoustical noise emissions:

Sound power, idling: 6.1 bels maximum

Sound power, operating: 6.1 bels maximum Environment:

Air temperature:

o Server on: 10°C to 35°C (50.0°F to 95.0°F); altitude: 0 to 914 m (2998.7 ft)

o Server off: -40°C to 60°C (-104°F to 140°F); maximum altitude: 2133 m (6998.0 ft)

Humidity:

Server on: 8% to 80%

Server off: 8% to 80%

Heat output:

Approximate heat output:

Minimum configuration: 662 Btu per hour (194 watts)

Maximum configuration: 2302 Btu per hour (675 watts) Electrical input:

Sine Waave Input (47-63 Hz) required

Input voltage low range:

o Minimum: 100 V ac

o Maximum: 127 V ac

Input voltage high range:

o Minimum: 200 V ac

o Maximum: 240 V ac

(4)

Input kilovolt-amperes (kVA), approximately:

o Minimum: 0.194 kVA

o Maximum: 0.700 kVA Video controller (ntegrated into IMM):

Matrox G200 (two analog ports – one front and one rear that can be connected at the same time)

Note: The maximum video resolution is 1280 x 1024 at 75 Hz.

SVGA compatible video controller

DDR2 250 MHz SDRAM video memory controller

Avocent Digital Video Compression

Video memory is not expandable Notes:

1. Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.

2. The sound levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The noise emission level stated in the declared (upper limit) sound-power level, in bels, for a random sample of system.

(5)

2. Front View

Fig 1 - Front View

Fig 2 - Front Locations

Figure 2 provides feature identification for the front view

Fig 3 - Light Path Diagnostic Panel

Figure 4 provides detailed identification for the operator information panel view of the Light Path Diagnostics pad

(6)

Fig 4- Operator Panel LED Information

Fig 5 - Light Path Panel Release

(7)

3. Rear View

Fig 1 - Rear View

Fig 2 - Rear Features

(8)

4. Inside View

Fig 1 - Planar View

(9)

Fig 2 - Planar Jumpers Locations

(10)

5. System Architecture

Fig 1 - System Architecture Processor

The x3550 M2 and x3650 M2 systems implement the Intel Xeon 5500 (Nehalem-EP) dual and quad core processors. The Intel Nehalem-EP processors with quick path processor includes up to four processor cores, larger shared cache and an integrated Memory Controller (IMC) that resides within the processor package.

Processor Related Notes

The server supports up to two Intel Xeon® dual-core or quad-core microprocessors. See

(11)

http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of supported microprocessors.

Do not mix dual-core and quad-core microprocessors in the same server.

Memory

The memory handling for the x3550 M2 and x3650 M2 may be different from many previous server models implementing Intel processors. This section highlights several areas to help you understand the memory configuration and operation. Also, single DIMM failures can be identified on this system. See details in the problem

determination section.

Memory Related Notes

The server supports only industry-standard double-data-rate 3 (DDR3), 800, 1066, or 1333 MHz, PC3-10600R-999 (single-rank or dual-rank), registered, synchronous dynamic random-access memory (SDRAM) dual inline memory modules (DIMMs) with error correcting code (ECC). See

http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a list of supported memory modules for the server. See Troubleshooting memory on IBM System x and BladeCenter Servers for more information on performing memory problem determination

Memory Mirroring

The x3550 M2 and x3650 M2 servers support memory mirroring (mirroring mode).

Memory-mirroring mode replicates and stores data on two pairs of DIMMs within two channels simultaneously. If a failure occurs, the memory controller switches from the primary pair of memory DIMMs to the backup pair of DIMMs.

To enable memory mirroring through the Setup utility, select System Settings → Memory. For more information, see "Using the Setup utility" section in the Installation and User’s Guide.

Memory Mirroring Related Notes

Memory DIMMs must be installed in pairs when using memory mirroring mode. The pair of DIMMs must match in size type, rank and organization but speed can be different. (The memory speed will run at the slowest speed of any DIMM installed)

Technologies and Features

The servers use the following features and technologies:

Integrated Management Module

The Integrated Management module (IMM) combines service processor functions, video controller, and (when an optional virtual media key is installed) remote presence

(12)

function in a single chip. The IMM provides advanced service-processor control, monitoring, and alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM also provides a virtual presence capability for remote server management capabilities.

The IMM provides remote server management through the following industry-standard interfaces:

Intelligent Platform Management Interface (IPMI) version 2.0

Simple Network Management Protocol (SNMP) version 3

Common Information Model (CIM)

Web browser

UEFI-compliant Server Firmware

The IBM System x Server Firmware offers several features, including Unified Extensible Firmware Interface (UEFI) version 2.1 compliance, Active Energy

Management (AEM) technology, enhanced reliability, availability, and serviceability (RAS) capabilities, and basic input/output system (BIOS) compatibility support. UEFI replaces the legacy BIOS. UEFI defines a standard interface between the operating system, platform firmware and external devices, and offers capabilities that far exceeds that of the legacy BIOS. The server design combines the UEFI capabilities and features with legacy BIOS compatibility. The server is capable of booting UEFI-compliant operating systems, BIOS-based operating systems, and BIOS-based adapters as well as UEFI-compliant adapters.

Note: The server does not support DOS (Disk Operating System).

IBM Dynamic Systems Analysis Preboot Diagnostic Programs

The Dynamic System Analysis (DSA) Preboot diagnostics programs are stored on the integrated USB memory. It collects and analyzes system information to aid in

diagnosing server problems. The diagnostic programs collect the following information about the server:

System configuration

Network interfaces and settings

Installed hardware

Light path diagnostics status

Service processor status and configuration

Vital product data, firmware, and UEFI (formerly BIOS) configuration

Hard disk drive health

RAID controller configuration

Event logs for ServeRAID controllers and service processors

The diagnostic programs create a merged log that includes events from all collected logs. The information is collected into a file that you can send to IBM service and support. Additionally, you can view the information locally through a generated text

(13)

report file. You can also copy the log to a removable media and view the log from a Web browser.

For additional information about DSA Preboot diagnostics, see the Problem Determination and Service Guide on the IBM System x Documentation CD

IBM X-Architecture Technology

IBM X-Architecture technology combines proven, innovative IBM designs to make your Intel-processor-based server powerful, scalable, and reliable. For more

information, see

http://www.ibm.com/servers/eserver/xseries/xarchitecture/enterprise/index.html .

VMware ESXi Embedded Hypervisor

The VMware ESXi Embedded Hypervisor is available on some server models.

Hypervisor is virtualization software that enables multiple operating systems to run on a host system at the same time. The VMware ESXi embedded hypervisor software is provided on USB flash device (Figure 1) that is installed in the USB connector on the SAS/SATA RAID riser card (Figure 1). See “Using the embedded hypervisor” section of the Installation and User’s Guide

Fig 1 - Optional Hypervisor Key

Remote presence capability and blue-screen capture

(14)

The remote presence and blue-screen capture features are integrated functions of the Integrated Management Module (IMM) and are available with the purchase of the optional IBM Virtual Media Key (Figure 2). A virtual media key is required to enable the remote presence and blue-screen capture features.

Fig 2 - Optional Virtual Media Key installed (Blue Key)

(15)

Fig 3 - Planar LED Locatons

References

Related documents

The Cisco T3/E3 Service Module provides the performance requirements to deploy advanced voice, video, and data applications over the WAN and supports key Cisco IOS Software

GMSA Corporate Marketing will be allowed to place ads advertising the availability of credit with offers that apply to all GMSA Retailers based on the fact that GMSA

As a dsDNA phage, it also requires holin (T, the product of gene t), cytoplasmic endolysin (E, product of e), and spanin (PseT.3 - PseT.2 complex, products of pseT.3 and pseT.2)

Being taken care will mtnl telephone wire has been using the phone numbers for the cheque will be forced to complain about mtnl support for disturbance?. Trouble for my name can

Spectral Distribution of Extraterrestrial Radiation • In addition to the total energy in the solar spectrum (i.e. the solar constant), it is useful to know the

Whether one's choice is direct cremation or immediate burial — the least expensive funeral options — costs on a sampling of funeral homes' price lists start with basic services,

Key Features Key Benefits • Easy-to-Use Interface • Powerful, Fast Processor • Unified Search Across all Evidence • Integrated Smartphone and Tablet Module • Automated External

 Also, some androgens are active on the skin leading to increased metabolic activity in acne- leading to increased metabolic activity in acne- prone areas of the skin..  Patient