KHJ-LED Explosion Proof Lighting

Sw

ord

fis

h S

eri

es

LED Explosion proof Floodlight

Ex Mark:Ex d eb op is ⅡB T6 Gb

(2)

INTRODUCTION

Features and benefits

1.Energy saving. Reduce the number of luminaires you need, providing excellent efficacy-more light

where you need it.

2.Anti-glare.reduces glare in applications where the user may have direct visual contact with the light source. 3.Shock- and vibration-resistant- tempered glass , reduces the risk of premature failure.

4.OSRAM LED source. High efficacy lumen output and high CRI.

5.Lifespan L-70 120,000 hours.>

6.Driver module assembly -High efficiency LED drivers are designed to provide reliable operation in even the harshest environments.

7.Copper -Free Aluminum enclosure, can endure 10J impact. IP66, can be used in marine and wet locations-robust

construction suitable for saltwater and corrosive applications. 8. Different installation methods.

9.Safety chain design. Prevent any fall-off. 10.High power factor,energy saving.

11.Ambient temperature from -20ºC to 55ºC.

Applications:

1.Petroleum Industry, Petrochemical Industry, Metallurgical Industry, Power Generation Industry, Power Transmission Industry, Machine Manufacturing. etc.

2.Drilling platform, single point moorings, oil tanks, workover platform, production platform, field tank, manifold center, pumping station, gasoline station, transformer station, coating plant ,warehouse .etc.

Executive standard:

·IEC 60079-0:2007 IEC 60079-1:2007 · IEC 60079-7:2006 · EN 60079-0:2009 · EN 60079-1:2007 ·

Division:

·ATEX Zone 1 & 21 and 2 & 22

Certifications & Ratings:

B T6 Gb ·Ex d eb op is Ⅱ ·Ex tb op is ⅢC T80℃ Db ATEX Compliant · ·IECEx Compliant ·ABS Compliant CE Compliant · ·EN 60079-7:2007 EN 60598-1:2008+A11:2009 · EN 55015:2013 · IEC 62321:2008 ·

(3)

Characteristic details

CHARACTERISTIC DETAILS

OSRAM LED source ,high efficacy and

lumen output.

LED clung to the enclosurewhich make heat dissipation fast.Lower the junction Temp.

Copper -Free Aluminum enclosure , anti-corrosion. Suitable for different application.

Industrial aluminium alloy enclosure, high performance of anti- impact. Can endure 10J impact.

(4)

PERFORMANCE PARAMETER

PERFORMANCE PARAMETER

Product Definition

Electrical Parameter:

SF-Swordfish H7V7-150°

Type Brand Series Power Input voltage Size(mm) Candela  CCT(K) Type Type Area Distribution K-KHJ 18-18W 36-36W 48-48W 56-56W 72-72W AC-100~277V A-AC/DC 24~48V B-DC 10~30V 600-600mm 1200-900mm WM-2700~3300K NH-3700~4300K CH-5400~7000K U-Update Ex- K SF XX XX XX XX  XX -U -H -E Ex-Explosion Proof

Product type voltage(VAC) Rated input voltage(VDC) Rated input current(A) Rated input Frequency (Hz)

Rated power

(W) LED input current (mA) PF THD Ex-KSF18600 100~277 0.18~0.07 50/60 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 18 60 >0.98 <10% <10% <10% <10% <10% <10% <10% Ex-KSF18A600 24~48 24~48 0.77~0.38 18 60 Ex-KSF18B600 10~30 1.84~0.61 18 60 Ex-KSF36600 100~277 0.37~0.13 50/60 36 60 >0.98 Ex-KSF36A600 24~48 24~48 1.53~0.77 36 60 Ex-KSF36B600 10~30 3.67~1.22 36 60 Ex-KSF48600 100~277 0.49~0.18 50/60 48 60 >0.98 Ex-KSF48A600 24~48 24~48 2.04~1.02 48 60 Ex-KSF48B600 10~30 4.9~1.63 48 60 Ex-KSF361200 100~277 0.37~0.13 50/60 36 60 >0.98 Ex-KSF36A1200 24~48 24~48 1.53~0.77 36 60 Ex-KSF36B1200 10~30 3.67~1.22 36 60 Ex-KSF481200 100~277 0.49~0.18 50/60 48 60 >0.98 Ex-KSF48A1200 24~48 24~48 2.04~1.02 48 60 Ex-KSF48B1200 10~30 4.9~1.63 48 60 Ex-KSF561200 100~277 0.57~0.21 50/60 56 65 >0.98 Ex-KSF56A1200 24~48 24~48 2.38~1.19 56 65 Ex-KSF56B1200 10~30 5.71~1.9 56 65 Ex-KSF721200 100~277 0.73~0.27 50/60 72 60 >0.98 Ex-KSF72A1200 24~48 24~48 3.06~1.53 72 60 Ex-KSF72B1200 10~30 7.35~2.45 72 60 H-High output E-English

(5)

PERFORMANCE PARAMETER

Performance Parameter

Other parameter

Product type P/N Color temp. CCT(K ) CRI Luminous flux(lm) Beam angle(°)

Ex-KSF18*600

Ex-KSF18*600H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF18*600H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF18*600H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF36*600

Ex-KSF36*600H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF36*600H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF36*600H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF48*600

Ex-KSF48*600H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF48*600H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF48*600H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF36*1200

Ex-KSF36*1200H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF36*1200H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF36*1200H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF48*1200

Ex-KSF48*1200H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF48*1200H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF48*1200H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF56*1200

Ex-KSF56*1200H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF56*1200H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF56*1200H7V7CH-U-H-E Cool white 5400~7000 80 150 Ex-KSF72*1200

Ex-KSF72*1200H7V7WM-U-H-E Warm white 2700~3300 80 150 Ex-KSF72*1200H7V7NH-U-H-E Natural white 3700~4300 80 150 Ex-KSF72*1200H7V7CH-U-H-E Cool white 5400~7000 80 150 Remarks: *Stands for Rated input voltage, including Default-AC-100~277V,A-AC/DC 24~48V,B-DC 10~30V.

Product type Size(mm) Weight(Kg)

Ambient temp (℃)

Max. surface temp.(test

in 25℃) Temp.classification Code IP Insulation

Ex-KSF18600*-U 600*136*85 6.4 -20~+55 33 T6 IP66 Ⅰ Ex-KSF36600*-U 600*136*85 6.4 -20~+55 37 T6 IP66 Ⅰ Ex-KSF48600*-U 600*136*85 6.4 -20~+55 48 T6 IP66 Ⅰ Ex-KSF361200*-U 900*136*85 8.7 -20~+55 37 T6 IP66 Ⅰ Ex-KSF481200*-U 900*136*85 8.7 -20~+55 39 T6 IP66 Ⅰ Ex-KSF561200*-U 900*136*85 8.7 -20~+55 42 T6 IP66 Ⅰ Ex-KSF721200*-U 900*136*85 8.7 -20~+55 46 T6 IP66 Ⅰ 1900 2376 2376 3801 4752 4752 5068 6336 6336 3801 4752 4752 5068 6336 6336 5913 7392 7392 7603 9504 9504

(6)

Unit: mm L(Max) L(Min) 0.6M 0.9M 550850 500500 L 104 146 Unit: mm 128 Unit: mm Unit: mm L Unit: mm L(Max) L(Min) 0.6M 0.9M 620920 570570 L T(Max) T(Min) 40 5 T L(Max) L(Min) 0.6M 0.9M 625925 575575 L 30 ° 180° L L(Max) L(Min) 0.6M 0.9M 292 257 L 550 500 500 850 Unit: mm Φ40~Φ60 L(Max) L(Min) 0.6M 0.9M 625925 575575 L(Max) L(Min) 0.6M 0.9M 550850 500500

INSTALLATION METHOD

Installation method

Stanchion mount

Clamp mount

Pipe clamp

Wall mount

Candela Distribution

400 600 cd/klm C0 - C180 C90 - C270 0° 15° 30° 45° 60° 75° 90° 105° 105° 90° 75° 60° 45° 30° 15°

(7)

ACCESSORIES

900 136 85 36W 48W 56W 72W 18W 36W 48W 600 85 136 Unit: mm Unit: mm

Size

Optional parts

Accessories

Loop Pipe Clamp Clamp mount

1 Q235 1.2 2 / 2 Q235 1.8 / 3 Q235 2.6 / 4 Q235 3.0 /

NO. Installation accessories Material Weight(Unit: kg) QTY Remarks

Loop Pipe Clamp Clamp mount 2 2 2 5 Q235 0.8 2 / Optional Parts Stanchion bracket Bracket Bracket Stanchion bracket

(8)

SERVICE

Package Check

1. Check the carton and all the components according to the packing list. 2.Make sure the product is in good conditions.

Installation and maintenance must be according to the instruction.

If customer can not deal with it by themselves ,please contact with sales department.

Please keep this product from heavy mechanical shock, exposure to strong sunshine, throwing, rolling and stress during transport

Caution

1.To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes.

2.To avoid electric shock:

Be certain electrical power is OFF before and during installation and maintenance. Luminaire must be supplied by a wiring system with an equipment grounding conductor. 3.To avoid burning hands:

Make sure lens and housing are cool when performing maintenance. 4.To avoid explosion:

1)Make sure the supply voltage is the same as the luminaire voltage.

2)Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous atmosphere.

3)Do not operate in ambient temperatures above those indicated on the luminaire nameplate. 4)All gasket seals must be clean.

5)Before opening, electrical power to the luminaire must be turned off. Keep tightly closed when in operation.

Transportation

Storage

Kept in dry,clean and well-ventilated ,non-corrosive medium warehouse,the ambient temperature should be -40℃ to 55℃.

After-sales service

Contact

Chin Power LTD.

---Address: 2/219-220 Phaholyothin Rd., Samsannai, Phayathai, Bangkok, Thailand 10400

Tel: +66-2615-0660

References

Related documents

Fleischman's research area is seismic resistant design and resilience of precast/prestressed concrete and steel structures with recent projects including the development of

The Affordable Care Act requires most people to have health care coverage that qualifies as “minimum essential coverage.” This plan or policy does provide minimum essential

meeting in Amsterdam on 22 April 2016, Member States underlined the critical importance of continuing and intensifying action in this field at national, EU and global level,

This research study examined the effectiveness of the Sistas Accessing HIV/AIDS Resources At a click (SAHARA) computer-based, behavioral prevention intervention with a population

• CCAR 2011, has been followed with CCAR 2012 and CCAR 2013 – in alignment with the Dodd Frank Act’s requirements for annual capital adequacy assessment and stress

However, other photographic sequences have shown that when a 2 mm diameter tungsten carbide sphere impacted a block of soda – lime glass at normal incidence at a velocity of 130

- When using the equipment in conjunction with explosion proof motor , a technician with electrical expertise should supervise the transport, installation, plumbing,

Exercise 1.3: Sketching using Rectangle and Circle (5 minutes) Create this sketch on the Front Plane using rectangle and circle, automatic relations and dimensions.. Exercise

TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES.. Failure to install the power supplies and/or

The disposer must be connected to a grounded, metal, permanent wiring system; or a disposer-grounding conductor must be run with the circuit conductors and connected to

If the University cancels the contract for breach, the University reserves the right to obtain the equipment, supplies, and/or services to be provided pursuant to the contract

Given the disease disparities and research rationale described above for AA populations, the projects conducted here sought to discover risk variants for overall and

· Electrical power shall be cut off during all cable and electrical equipment maintenance, and isolation, lockout/tagout and safety caution signs shall be used during all

Exercise is Medicine® Australia Locked Bag 102, Albion DC QLD 4010 Phone: 07 3862 4122 | Fax: 07 3862 3588 | Email: info@exerciseismedicine.org.au Role of an AEP The most

interpretation of electrical code rules, a general understanding of conductor sizing, wiring methods, and grounding is essential to PV system design..

Arithmetical means range from 3.64 to 4.38; item stating that &#34; Providing the scientific and practical knowledge specialized in the accounting information systems

Further study of the impact of autonomous systems on formal Navy mission sets, like Navy Tasks, should be conducted to identify the level of autonomy required for accomplishment

In this note, we report and dis- cuss this finding, which, together with the revision of the entomological collections of the Magyar Természettudományi Múzeum (Hungarian Natural

Before monitoring for contamination, portable instruments should be given operational checks as specified by the manufacturer (i.e. battery check, high-voltage check, response