• No results found

Page 1. Description

N/A
N/A
Protected

Academic year: 2021

Share "Page 1. Description"

Copied!
7
0
0

Loading.... (view fulltext now)

Full text

(1)

Description Tectron Surf

for flushing cistern GD 2 concealed installation CE-approved

front plate 156 x 197 mm infra-red control

servo motor

transformer for external installation operating voltage 230 V AC adjustable flow time

with function check lamps

adjustable by infra-red control 36 206

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(2)

Dimensional drawing

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(3)

Exploded drawing

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(4)

Part list

Pos. Description Order-No.: Unit

1 Tectron Surf wall plate 42193 000 1

2 control unit for servomotor 43279 000 1

3 Mounting frame 42736 000 1 4 Fixing set 42158 00M 4 5 transformer 42278 000 1 6 transformer-connecting box 42279 000 1 7 Pipe riser 43281 000 1 7.1 Support device 42246 000 1

7.2 Motor support device 43617 000 1

8 Mounting set 43306 000 1

9 Mounting set 43307 000 1

10 Extention cable 36221 000 1

Special accessories:

11 Infra-red remote control 36206 000 1

12 Extention cable 36222 000 1

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(5)

Maintenance instructions Shut off water supply!

Please perform disassembly in specified order. Transformer

1. Switch off voltage supply.

2. Disconnect extension cable from headpart and lever off existing transformer headpart. 3. Attach a new headpart.

4. Connect headpart and extension cable. 5. Switch on voltage supply.

Servo motor

1. Loosen locking screw.

2. Remove plate upwards from frame.

3. Remove holder with servo motor from crossrail, detaching lift rod from the lever.

4. Disconnect plug-in connection between electronic module and servo motor.

5. Calibrating new servo motor, see Calibrating the servo motor.

6. Installing new servo motor, see Installing the servo motor. Wall plate with electronics

1. Same procedure as for cartridge maintenance, points 1 - 3. 2. Loosen screws and remove holder.

3. Replace old electronic module and install new electronic module on plate

in reverse order.

4. Remove holder with servo motor from crossrail, detaching lift rod from the lever.

5. Calibrating servo motor, see Calibrating the servo motor. 6. Installing servo motor, see Installing the servo motor. Setting the waste valve to 9 l flow volume

1. Same procedure as for cartridge maintenance, points 1 - 3. 2. Lift waste valve, rotate by 180° and re-engage

so that overflow 9 l shows. Adjusting the float

1. Same procedure as for cartridge maintenance, points 1 - 2. 2. Adjusting the float body:

- Turn upwards: max. capacity - Turn downwards: min. capacity Assemble in reverse order.

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(6)

Calibrating the servo motor

Caution: The servo motor must be calibrated outside the cistern.

1. For this purpose, the voltage supply of the electronic module must be disconnected and reconnected without the servo motor being connected. The LED in the electronics begins to flash.

2. Connect servo motor to electronic module. The LED in the electronics ceases to flash, and adjustment automatically starts once the servo motor has been connected to the electronics. The servo motor moves to the adjustment positions. Caution: Ensure that the movement is not disrupted by obstacles. To prevent falsification of the servo motor

adjustment, the lever must not be disassembled. Calibration has been completed when the lever is in the centre position.

Caution: Do not detach the connection between the servo motor and the electronic module after calibration. 3. Disconnect the voltage supply: Disconnect connection between electronic module and extension cable. Installing the servo motor

Note: Installation is also possible on the opposite side. If the water connection is attached on the right-hand side, the servo motor must be mounted on the left and the lever must be attached to the lift rod from behind.

1. Place servo motor in the cistern, attaching the lever of servo motor in lift rid from front. 2. Engage servo motor in crossrail in cistern.

3. Connect the voltage supply: Connect electronic module with the extension cable. Setting mode is activated.

Setting mode

The flow volume can be checked and changed in setting mode (see Setting the flow volume).

The detection zone of the fitting can be checked. The indicator lamp in the sensor system of the fitting illuminates in setting mode when the detection zone of the fitting is reached by an approaching user.

It is possible to set the detection zone via the optional remote control. Flushing is immediately triggered when the detection zone is

exited again. The minimum delay time of 7s

is not available in setting mode. To activate setting mode, proceed as follows:

Disconnect the power supply to the electronics and reconnect after 5s. The plug connection between the servo motor and the electronics must not be detached!

Setting mode is activated.

Setting mode is automatically terminated after 3 min.

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

(7)

Setting the flow volume

The factory-set flow volume corresponds to the waste valve position (6 or 9litres).

Flow volumes in excess of 6 l are only possible if the waste valve is set to 9 litres, see Setting the waste valve to 9 l flow volume if applicable, and the cistern has an appropriate capacity.

The flow volume can be changed as follows: 1. Activate setting mode (see above).

2. Hold hand at a distance of approx. 5 - 10cm in front of the sensor system in the fitting. The indicator lamp in the sensor system of the fitting flashes quickly.

3. The indicator lamp extinguishes automatically after approx. 5 s. 4. Remove hand from the detection zone (at least 90cm).

5. Again hold hand at a distance of approx. 5 - 10cm in front of

the sensor system. The flow volumes are indicated via the indicator lamp in the sensor system by groups of flashing signals separated by a pause.

6. Flow volumes and display:

The number of flashing signals of the consecutive groups corresponds to the following flow volumes:

- 3 = flow volume 3 litres - Pause

- 4 = flow volume 4 litres - Pause

- 5 = flow volume 5 litres - Pause

- 6 = flow volume 6 litres (even with waste set to 9 litres) - Pause

- 7 = flow volume 6 or 9 litres (depending on the waste valve position) = factory setting

- Pause

After the group with 7 flashing signals, the routine starts from the beginning. 7. Selecting the flow volume

The flow volume is selected by removing the hand from the detection zone (at least 90cm) in the pause after a group of flashing signals. Once the hand is removed, the fitting immediately flushes with the selected flow volume (the

corresponding flashing signals are displayed again during flushing).

8. The flow volume can be readjusted within the next 20 s if necessary by again holding the hand at a distance of 5 -10cm in front of the sensor system (see point 5).

The selected flow volume is accepted as the new setting and setting mode is automatically terminated if there is no hand in front of the sensor system within 20 s of flushing. The area directly in front of the sensor system must be kept free from objects for these 20 s as otherwise the flow

volume will be unintentionally adjusted once more.

GROME MARKETING (CYPRUS) LTD. | TEL: + (357) 22 465 200 | email: [email protected] | www.grome.com | 195 B, Old Nicosia-Limassol Road, Dhali Industrial Zone,CY-2550 Nicosia

References

Related documents

In this study, it is aimed to develop the Science Education Peer Comparison Scale (SEPCS) in order to measure the comparison of Science Education students'

In a study into the relation between perceptions of the school psychological environment and school-related beliefs, affect and achievement, Roeser, Midgley and Urdan (1996)

[r]

This study reveals some significant points: (1) The pattern of interaction between the family of former terrorists convict and surrounding communities can be

Quality: We measure quality (Q in our formal model) by observing the average number of citations received by a scientist for all the papers he or she published in a given

The information published is compiled from several sources that include local Maritime Associations, Pilot Logs, Terminal Line-Ups, EIA Data, US Customs, Port and Trade

This standard contains the essential welding variables for carbon steel plate and pipe in the thickness range of 16 through3/4 in., using manual shielded metal arc welding. It cites

4 www.cpsc.gov HOME ELECTRICAL SAfETy CHECkLIST KITCHEN BA THROOMS OTHERS OUTDOORS BEDROOMS CONTENTS PUBLICA TIONS 5 ALL ROOMS In ALL Rooms Check Lights.. Check each light in the