• No results found

Remote Control Station Via Telephone

N/A
N/A
Protected

Academic year: 2021

Share "Remote Control Station Via Telephone"

Copied!
5
0
0

Loading.... (view fulltext now)

Full text

(1)

LIELBA -

AD40

Remote Control Station Via Telephone

Technical Teaching Equipment

ELEMENTS ALLOCATION

ALI02 VAR05 CTR01

www.edibon.com

Products Products range Units 4.-Electricity Modules:

(2)

SPECIFICATIONS

Page 2 www.edibon.com

Application, in metallic box, including the following modules: ALI02. Main Power Supply:

Single-phase plug. 2 lamps.

Terminals: L (line), N (neutral) and GND (ground). Security mushroom.

Removable Key with two positions (ON and OFF) that works as the main switch. CTR01. Basic Control Module:

Input Voltage: 2 terminals of 230 Vac. Frequency: 50Hz.

5 input terminals.

5 relay outputs (20 terminals). 1 input for an internal telephone line. 1 input for an external telephone line.

The use of this module is made through the telephone (VAR05 module). The system can be personalized for each user programming 4 numbers phone as a maximum for outside calls, selecting the languages of the spoken messages (English, Spanish or German) or using the A and B services to manage an automatic device.

VAR05. Tones dialing telephone:

This module includes a tones dialing telephone.

Two-pole automatic differential switch and two-pole automatic thermal-magnetic switch for the security of the elements. Cables and Accessories, for normal operation.

Manuals: This unit is supplied with the following manuals: Required Service, Assembly and Installation, Starting-up, Safety, Maintenance and Practices Manuals.

EXERCISES AND PRACTICAL POSSIBILITIES

1.- Checking the Main Power Supply (ALI02). 5.- Presence detector simulation control through Basic Control Module (CTR01).

2.- Basic Control Module (CTR01) configuration.

3.- Flooding detector simulation control through Basic Control Module (CTR01).

4.- Gas detector simulation control through Basic Control Module (CTR01).

DIMENSIONS & WEIGHT

REQUIRED SERVICES

-Electrical supply: single-phase, 220V./50 Hz or 110V./60 Hz. -Dimensions: 490 x 450 x 470 mm. approx.

(19.29 x 17.72 x 18.50 inch. approx.).

-Weight: 10 Kg. approx.

(3)

Examples of the Software screens

CAI. Computer Aided Instruction Software System

With no physical connection between the application and computer, this complete package consists on an Instructor Software (INS/SOF) totally integrated with the Student/Application Software. Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. These, on the other hand, get a virtual instructor who helps them to deal with all the information on the subject of study.

INS/SOF. Classroom Management Software Package (Instructor Software). The Instructor has a whole range of options, among them:

- Organize Students by Classes and Groups.

- Create easily new entries or delete them.

- Create data bases with student information.

- Analyze results and make statistical comparisons.

- Print reports.

- Develop own examinations.

- Detect student ’s progress and difficulties.

...and many other facilities.

This Instructor Software working in network configuration allows controlling all the students in the classroom.

A.../SOF Computer Aided Instruction Software (Student/Application Software). It explains how to use the application, run the experiments and what to do at any moment.

- The options are presented by pull-down menus and pop-up windows.

- This software contains:

Theory: that gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood.

Guided Practices: presents several practices to be done with the application, showing how to complete the exercises and practices.

Application

+

Instructor

Software ApplicationStudent/ Software

Additional and optional:

Instructor Software

(4)

Software Main Screen

1.- Voltage channels section 2.- Current channels section 3.- Power spectrum section 4.- General control panel section

MUAD. Electric Power Data Acquisition System

Cables to interface Connections points 1 2 3 4 “n” Application Electric power interface box

(EPIB) Studentpost Data acquisition software (MUAD/SOF) Data acquisition board Cable to computer (D AB)

MUAD is the perfect link between the application and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process.

MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope.

We easily connect the Electric Power Interface Box (EPIB) to the application with the supplied cables (there are several connection points placed for it). The EPIB is connected to the PC through the Data Acquisition Board (DAB), and by using the Data Acquisition software with virtual instrumentation, the student can get results from the undertaken experiment/practice, see them on the screen and work with them.

MUAD System includes EPIB + DAB + MUAD/SOF: 1)Hardware:

1.1) EPIB. Electric power interface box ( dimensions: 300 x 180 x 120 mm. approx.):

Interface that carries out the conditioning of the diverse signals that can be acquired in a process, for their later treatment and visualisation.

In the front panel, the elements are separated in two parts: left-hand part for VOLTAGE sensors, and right-hand part for CURRENT sensors.

8 analog input channels.

Sampling range: 250KSPS (Kilo samples per second). 4 Tension sensors AC/DC, 400V.

4 Current sensors.

1.2) DAB. Data acquisition board:

Analog output: PCI Data acquisition board (National Instruments) to

Number of channels=2. be placed in a computer slot.

Resolution=16 bits, 1 in 65536. Bus PCI.

Maximum output rate up to: 833 KS/s. Analog input:

Output range(V)= 10V. Number of channels= 16 single-ended or 8

Data transfers=DMA, interrupts, differential.

programmed I/0. Resolution=16 bits, 1 in 65536.

Digital Input/Output: Sampling rate up to: 250 KSPS (Kilo samples

Number channels=24inputs/outputs. per second). D0 or DI Sample Clock frequency: 0 to 1 Input range (V)= 10V. MHz.

Data transfers=DMA, interrupts, programmed I/0. Timing: Counter/timers=2.

Number of DMA channels=6. Resolution: Counter/timers: 32 bits.

±

±

2) MUAD/SOF. Data acquisition software:

Data Acquisition Software with Graphic Representation: Friendly graphical frame.

Compatible with actual Windows operating systems.

Configurable software allowing the representation of temporal evolution of the different signals. Visualization of a tension of the circuits on the computer screen.

Sampling velocity up to 250 KSPS. (Kilo samples per second).

Page 4 www.edibon.com

EPIB

DAB

(5)

1) CAI + MUAD working possibility(complete EDIBON system) Some working possibilities:

+

+

CAI.

Computer Aided Instruction Software System Electric Power Data Acquisition SystemMUAD

4) Simplest working possibility EPIB.Electric Power Interface Box

MUAD/SOF.Data Acquisition Software DAB. Data Acquisition Board

+ +

+

INS/SOF. Instructor Software

A.../SOF. Student/Application Software

2) MUAD working possibility

3) CAI working possibility

+

MUAD

Electric Power Data Acquisition System

EPIB.Electric Power Interface Box

MUAD/SOF.Data Acquisition Software DAB. Data Acquisition Board

+ +

+

CAI.

Computer Aided Instruction Software System +

INS/SOF. Instructor Software

A.../SOF. Student/Application Software

*

Specifications subject to change without previous notice, due to the convenience of improvements of the product.

REPRESENTATIVE:

Application (AD40)

Application (AD40)

Application (AD40)

References

Related documents

It is common practice in the balance-of-payments constrained growth literature to estimate export and import functions using vector error correction models (VECMs), while

In a second phase, it identifies what has been the authorities' role in the climate change adaptation process carried out by ski area operation companies by looking specifically

Thus reframed, classic and contemporary socialist literature in school textbooks and pioneer magazines did not only provide knowledge of major historical events

Distribution of non- aureus staphylococci (NAS) species intramammary infection from bovine milk in Canadian dairy herds and intraclass correlation (ICC) of quarters within cow,

Though students and families are borrowing more to cope with the ever-growing cost of college, the loans that they are taking out may actually be a cause, as well as a result, of

CONTRACT OF SALE, CONDOMINIUM UNIT, PRE-SELLING (SAMPLE

(Notes) Target 2018/19 Actual 2018/19 Target met(√) /not met 7 Increase BBBEE expenditure in relation to operational projects Spend increased and increased new entrants