HAVE CHANGED DUE TO REPRODUCTION. NOTE: THE SCALE OF THESE PLANS MAY
P.E. NO.: ENGINEER OF RECORD: PLANS PREPARED BY: SHEET DESCRIPTION SHEET NO. TO BE SUBMITTED TO: NO. SHEET YEAR FISCAL 12:16:59 PM T:\PROJECTS\OOCEA\Wekiva_203'\CADD\its\keyssp01.dgn USER: moze6236 5/27/2014 BEE LINE EXPRESSWAY FL OR I DA S TURN PIKE 10 PENSACOLA FORT WALTON BEACH PANAMA CITY CHIPLEY TALLAHASSEE 75 10 LAKE CITY 295 95 JACKSONVILLE ST AUGUSTINE GAINESVILLE
OCALA DAYTONA BEACH DELAND
4
NEW PORT RICHEY TAMPA 75 4 LAKELAND MELBOURNE -COCOA ORLANDO BARTOW ST PETERSBURG 275 SARASOTA -BRADENTON 75 95 FT PIERCE FT MYERS WEST PALM BEACH FT LAUDERDALE MIAMI 75 75 NAPLES KEY WEST
LOCATION OF PROJECT
EXPRESSWAY AUTHORITY MEMBERS ORLANDO-ORANGE COUNTY
14
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
OOCEA PROJECT NUMBER - 429-203
ORANGE COUNTY
N. OF PONKAN RD. TO N. OF KELLY PARK RD.
S.R. 429 (WEKIVA PARKWAY)
PLANS OF PROPOSED
54624FO-1
(407) 647-7275 ORLANDO, FL 32810 482 S. KELLER ROAD CERTIFICATE OF AUTHORIZATION #: 24 VENDOR #: 59-0896138.007 ORLANDO, FL 32810 482 S. KELLER ROAD ANDREW LUCYSHYN, P.E.FIBER OPTIC NETWORK PLANS
INDEX OF FIBER OPTIC NETWORK PLANS
FIBER OPTIC NETWORK SHOP DRAWINGS
FIBER OPTIC NETWORK PLANS
ANDREW J. LUCYSHYN, P.E., PTOE
DATE DESCRIPTION
KEY SHEET REVISIONS
http://www.dot.state.fl.us/rddesign/
"Design Standards" at the following web site: For Design Standards Modifications click on
APPLICABLE DESIGN STANDARDS MODIFICATIONS: 01/01/13 AS AMENDED BY CONTRACT DOCUMENTS.
BRIDGE CONSTRUCTION DATED 2013,
AND STANDARD SPECIFICATIONS FOR ROAD AND DESIGN STANDARDS DATED 2012/2013, FLORIDA DEPARTMENT OF TRANSPORTATION, GOVERNING STANDARDS AND SPECIFICATIONS:
ATKINS PROJECT MANAGER: ANDY LUCYSHYN, P.E., PTOE OOCEA PROJECT MANAGER: GLENN PRESSIMONE, P.E.
100% SUBMITTAL
NOT FOR CONSTRUCTION
CONTRACT #: 000851
JOSEPH BERENIS, P.E. MARCO PENA
NORANNE B. DOWNS, P.E. TERESA S. JACOBS SCOTT BATTERSON WALTER A. KETCHAM, JR.
INTERIM EXECUTIVE DIRECTOR BOARD MEMBER
MEMBER, FDOT SECRETARY SECRETARY/TREASURER VICE CHAIRMAN CHAIRMAN
1. COORDINATION WITH POWER COMPANIES IS ONGOING. NOTES TO REVIEWER: FO-93 FO-90 - FO-92 FO-89 FO-86 - FO-88 FO-85 FO-84 FO-81 - FO-83 FO-79 - FO-80 FO-78 FO-74 - FO-77 FO-73 FO-72 FO-71 FO-70 FO-69 FO-68 FO-67 FO-66 FO-65 FO-64 FO-61 - FO-63 F0-60 FO-59 FO-58 FO-57 FO-56 FO-55 FO-54 FO-53 FO-52 FO-51 FO-50 FO-49 FO-48 FO-47 FO-46 FO-44 - FO-45 FO-43 FO-42 FO-35 - FO-41 FO-34 FO-31 - FO-33 FO-30 FO-11 - FO-29 FO-9 - FO-10 FO-8 FO-5 - FO-7 FO-3 - FO-4 FO-2 FO-1
REPORT OF SPT BORINGS FOR DEVICE STRUCTURES STRUCTURE DETAILS ACCESS WALKWAY DETAILS DMS PANEL CONNECTION DETAILS
TRUSS DETAILS DMS TRUSS FRAMING DMS
BOX TRUSS SIGN STRUCTURE GENERAL NOTES TMS POLE STRUCTURE DETAILS
POWER SERVICE DETAILS CROSS SECTION DMS
ITS DEVICE GROUNDING DETAILS
DCS AND 3 LINE DMS DEVICE CO-LOCATION DETAIL 3-LINE DMS BACKWALL DETAIL SHEET
DCS ANTENNA ON DMS TRUSS DETAIL SHEET POLE DATA SHEET
TMS INSTALLATION (12-SIDED STEEL POLE) DMS CABINET DETAIL
TMS CABINET DETAIL DCS CABINET DETAIL
PROPOSED DCS COVERAGE AREA DETAIL PROPOSED DCS SIGN STRUCTURE MOUNTING WIRING DIAGRAMS
DCS RF READER MODULE CABINET WIRING DETAIL TMS TVSS WIRING DETAIL
ENVIRONMENTAL CABINET MONITOR CONNECTION DIAGRAM ETHERNET SWITCH DETAIL
CONCRETE PULL BOX MOW PAD DETAILS CONCRETE PAD DETAIL FOR SLOPES FIBER OPTIC MANHOLE STUBOUT DETAIL FIBER OPTIC MANHOLE GROUNDING DETAILS FIBER OPTIC MANHOLE DETAIL 4' X 6.5' X 6.5' FIBER OPTIC MANHOLE DETAIL 4' X 4' X 4' FIBER OPTIC MANHOLE COVER DETAIL
FIBERGLASS EXPANSION JOINT DETAIL BRIDGE HANGER DETAIL
TYPICAL BRIDGE APPROACH DETAIL DIRECTIONAL BORE DETAIL TRENCHING DETAILS ROUTE MARKER DETAILS
TYPICAL MAINLINE AND RAMP SECTIONS FON SPLICING DETAILS
LINK LOSS BUDGET FIBER ALLOCATION CHART
FIBER OPTIC CABLE ROUTING SUMMARY SR 429 PLAN SHEETS
PROJECT LAYOUT LEGEND
GENERAL NOTES
TABULATION OF QUANTITIES SUMMARY OF PAY ITEMS KEY SHEET
SUMMARY OF PAY ITEMS
FO-2
DESCRIPTION UNIT QUANTITY
FINAL
SUMMARY OF PAY ITEMS
ITEM NO.
PLAN
631-100 FIBER OPTIC CABLE INVENTORY EA
631-101 FIBER OPTIC SPLICE HOUSING INVENTORY EA
633-121-2 FIBER OPTIC CABLE (SINGLE MODE, 12 FIBER) (F&I) LF
633-121-4 FIBER OPTIC CABLE (SINGLE MODE, 72 FIBER) (F&I) LF
633-141-3 F.O. SPLICE ENCLOSURE (72 SPLICE) (F&I) EA
633-141-4 FIBER OPTIC FUSION SPLICE EA
635-1-11 PULL BOX (F&I) EA
635-1-15 SMALL FIBER OPTIC PULL BOX (F&I) EA
638-001-0211 F.O.C.,2-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF
638-001-0911 F.O.C.,9-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF
638-260-0011 F.O.C., 6" SPLIT BSP SLEEVE (TRENCH OR PLOW) LF
638-361-0911 F.O.C., 6" PVC CASING W/ 9-1" HDPE/SDR 11 (TRENCH) LF
638-461-0914 F.O.C., 6" BRFG BULLET-RESISTIVE FIBERGLASS OUTER DUCT LF
W/ 9-1" HDPE/SDR 11, INSTALL ON BRIDGE
639-1-22 ELECTRICAL POWER SERVICE ASSEMBLY (F&I) EA
639-3-11 ELECTRICAL SERVICE DISCONNECT (F&I) (POLE) EA
641-2-12 CONCRETE POLE (F&I) (12' TYPE P-I I SERVICE POLE) EA
663-74-142 DCS FIELD EQUIPMENT 2 LANES (F&I) EA
663-74-143 DCS FIELD EQUIPMENT 3 LANES (F&I) EA
664-1-140 TMS - POLE MOUNTED (F&I) EA
664-3-141 TMS - POLE MOUNTED (40' POLE) (F&I) EA
668-13 TYPE 170 CABINET (POLE MOUNTED) (F&I) EA
683-101 GIGABIT ETHERNET FIELD SWITCH (F&I) EA
683-103 HARDENED TERMINAL SERVER (F&I) EA
683-105 FIBER OPTIC PATCH PANEL - 12 PORT (F&I) EA
683-110 CUT-TO-LENGTH FIBER OPTIC JUMPER (F&I) EA
685-101 UNINTERRUPTIBLE POWER SUPPLY (F&I) EA
685-101A REMOTE POWER MANAGER (F&I) EA
685-103 CABINET / ENVIRONMENTAL MONITOR (F&I) EA
700-22-240 OVERHEAD TRUSS SPAN SIGN, (F&I) 151-200' EA
700-89-13F DMS (FULL COLOR) (LED) (WALK-IN) (F&I) EA
700-89-13F-SP FULL COLOR DMS (LED) (3 LINE) (SPARE PARTS) EA
715-2-115 CONDUIT 2" SCHEDULE 40 PVC (UNDERGROUND) (F&I) LF
783-8-1 TRAFFIC MONITORING STATION COMPOSITE CABLE (F&I) LF
4210-11 4'X4'X4' CONCRETE MANHOLE (F&I) EA
4210-12 4'X6.5'X6.5' CONCRETE MANHOLE (F&I) EA
LF CONDUCTORS (F&I) (INSULATED) #6 AWG
715-1-113
EA 678-1-111
REDUCTION ASSEMBLY
TRAFFIC CONTROLLER ACCESSORIES, F&I, POWER
664-3-140 TMS - POLE MOUNTED (30' POLE) (F&I) EA
22 5 7 455 491 1299 5 2 2 1 4 1 3 3 3 3 3 6 3 3 3 9298 3395 505 24 2 2 2 296 283 18758 3 1 2 2 2 844 52334
SR 429
429-203
PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 12:40:47 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\ITS_A03_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
FO-3
TABULATION OF QUANTITIES
ITEM NO. PAY SHEET REF. FINAL PLANFINAL PLAN FINAL
PLAN DESCRIPTION SHEET NUMBERS UNIT FINAL PLAN FINAL PLAN FINAL
PLAN PLAN PLAN FINAL
FINAL PLAN FINAL
PLAN FINAL PLAN FINAL
TOTAL GRAND SHEET
THIS TOTAL
FO-11 FO-12 FO-13 FO-14 FO-15 FO-16 FO-17 FO-18 FO-19 FO-20
TABULATION OF QUANTITIES
631-100 FIBER OPTIC CABLE INVENTORY EA 2 2
631-101 FIBER OPTIC SPLICE HOUSING INVENTORY EA 2 2
633-121-2 FIBER OPTIC CABLE (SINGLE MODE, 12 FIBER) (F&I) LF
633-121-4 FIBER OPTIC CABLE (SINGLE MODE, 72 FIBER) (F&I) LF
633-141-3 F.O. SPLICE ENCLOSURE (72 SPLICE) (F&I) EA 4 4
633-141-4 FIBER OPTIC FUSION SPLICE EA 292 292
635-1-11 PULL BOX (F&I) EA 7 2 9
635-1-15 SMALL FIBER OPTIC PULL BOX (F&I) EA 4 4
638-001-0211 F.O.C.,2-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF 258 258
638-001-0911 F.O.C.,9-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF 276 1362 565 1244 1401 1402 1401 1393 1394 1401 11838
638-260-0011 F.O.C., 6" SPLIT BSP SLEEVE (TRENCH OR PLOW) LF 20 20 30 20 10 20 20 140
638-361-0911 F.O.C., 6" PVC CASING W/ 9-1" HDPE/SDR 11 (TRENCH) LF 116 37 153
638-461-0914 F.O.C., 6" BRFG BULLET-RESISTIVE FIBERGLASS OUTER DUCT LF 716 111 827
W/ 9-1" HDPE/SDR 11, INSTALL ON BRIDGE
639-1-22 ELECTRICAL POWER SERVICE ASSEMBLY (F&I) EA 1 1
639-3-11 ELECTRICAL SERVICE DISCONNECT (F&I) (POLE) EA 2 2
641-2-12 CONCRETE POLE (F&I) (12' TYPE P-I I SERVICE POLE) EA 3 3
663-74-142 DCS FIELD EQUIPMENT 2 LANES (F&I) EA 2 2
663-74-143 DCS FIELD EQUIPMENT 3 LANES (F&I) EA
664-1-140 TMS - POLE MOUNTED (F&I) EA 2
664-3-141 TMS - POLE MOUNTED (40' POLE) (F&I) EA
668-13 TYPE 170 CABINET (POLE MOUNTED) (F&I) EA 2 2
683-101 GIGABIT ETHERNET FIELD SWITCH (F&I) EA
2
683-103 HARDENED TERMINAL SERVER (F&I) EA 2 2
683-105 FIBER OPTIC PATCH PANEL - 12 PORT (F&I) EA 2 2
683-110 CUT-TO-LENGTH FIBER OPTIC JUMPER (F&I) EA 4 4
685-101 UNINTERRUPTIBLE POWER SUPPLY (F&I) EA 2 2
685-101A REMOTE POWER MANAGER (F&I) EA 2 2
685-103 CABINET / ENVIRONMENTAL MONITOR (F&I) EA 2 2
700-22-240 OVERHEAD TRUSS SPAN SIGN, (F&I) 151-200' EA 1 1
700-89-13F DMS (FULL COLOR) (LED) (WALK-IN) (F&I) EA 2 2
700-89-13F-SP FULL COLOR DMS (LED) (3 LINE) (SPARE PARTS) EA 2 2
715-2-115 CONDUIT 2" SCHEDULE 40 PVC (UNDERGROUND) (F&I) LF 432 363 795
783-8-1 TRAFFIC MONITORING STATION COMPOSITE CABLE (F&I) LF 18 363 381
4210-11 4'X4'X4' CONCRETE MANHOLE (F&I) EA 3 1 1 1 2 2 10
4210-12 4'X6.5'X6.5' CONCRETE MANHOLE (F&I) EA
1684 LF
CONDUCTORS (F&I) (INSULATED) #6 AWG
715-1-113 1684
EA 678-1-111
REDUCTION ASSEMBLY
TRAFFIC CONTROLLER ACCESSORIES, F&I, POWER
2
664-3-140 TMS - POLE MOUNTED (30' POLE) (F&I) EA
2 2 2 2 2
SR 429
429-203
PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 12:40:47 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\ITS_A03_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
FO-4
TABULATION OF QUANTITIES
TABULATION OF QUANTITIES
ITEM NO. PAY SHEET REF. FINAL PLANFINAL PLAN FINAL
PLAN DESCRIPTION SHEET NUMBERS UNIT FINAL PLAN FINAL PLAN FINAL
PLAN PLAN PLAN FINAL
FINAL PLAN FINAL
PLAN FINAL PLAN FINAL
TOTAL GRAND SHEET
THIS TOTAL
FO-21 FO-22 FO-23 FO-24 FO-25 FO-26 FO-27 FO-28 FO-29
631-100 FIBER OPTIC CABLE INVENTORY EA
631-101 FIBER OPTIC SPLICE HOUSING INVENTORY EA
633-121-2 FIBER OPTIC CABLE (SINGLE MODE, 12 FIBER) (F&I) LF
633-121-4 FIBER OPTIC CABLE (SINGLE MODE, 72 FIBER) (F&I) LF
633-141-3 F.O. SPLICE ENCLOSURE (72 SPLICE) (F&I) EA 1
633-141-4 FIBER OPTIC FUSION SPLICE EA 2
635-1-11 PULL BOX (F&I) EA 4 1 1 5
635-1-15 SMALL FIBER OPTIC PULL BOX (F&I) EA 1 2
638-001-0211 F.O.C.,2-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF 25
638-001-0911 F.O.C.,9-1" HDPE/SDR 11 (TRENCH OR PLOW) (F&I) LF 1402 1098 1398 1391 228
638-260-0011 F.O.C., 6" SPLIT BSP SLEEVE (TRENCH OR PLOW) LF 20 245 20
638-361-0911 F.O.C., 6" PVC CASING W/ 9-1" HDPE/SDR 11 (TRENCH) LF 140 36 162
638-461-0914 F.O.C., 6" BRFG BULLET-RESISTIVE FIBERGLASS OUTER DUCT LF 156 316
W/ 9-1" HDPE/SDR 11, INSTALL ON BRIDGE
639-1-22 ELECTRICAL POWER SERVICE ASSEMBLY (F&I) EA 1
639-3-11 ELECTRICAL SERVICE DISCONNECT (F&I) (POLE) EA 1
641-2-12 CONCRETE POLE (F&I) (12' TYPE P-I I SERVICE POLE) EA 1 1
663-74-142 DCS FIELD EQUIPMENT 2 LANES (F&I) EA
663-74-143 DCS FIELD EQUIPMENT 3 LANES (F&I) EA 1
664-1-140 TMS - POLE MOUNTED (F&I) EA 2
664-3-141 TMS - POLE MOUNTED (40' POLE) (F&I) EA 1
668-13 TYPE 170 CABINET (POLE MOUNTED) (F&I) EA 1
1 1 1 2 1 1 1 468 685 706 522 124 2 4 3 3 2 1 1
683-101 GIGABIT ETHERNET FIELD SWITCH (F&I) EA
683-103 HARDENED TERMINAL SERVER (F&I) EA
683-105 FIBER OPTIC PATCH PANEL - 12 PORT (F&I) EA
683-110 CUT-TO-LENGTH FIBER OPTIC JUMPER (F&I) EA
685-101 UNINTERRUPTIBLE POWER SUPPLY (F&I) EA
685-101A REMOTE POWER MANAGER (F&I) EA
685-103 CABINET / ENVIRONMENTAL MONITOR (F&I) EA
700-22-240 OVERHEAD TRUSS SPAN SIGN, (F&I) 151-200' EA
700-89-13F DMS (FULL COLOR) (LED) (WALK-IN) (F&I) EA
700-89-13F-SP FULL COLOR DMS (LED) (3 LINE) (SPARE PARTS) EA
715-2-115 CONDUIT 2" SCHEDULE 40 PVC (UNDERGROUND) (F&I) LF
783-8-1 TRAFFIC MONITORING STATION COMPOSITE CABLE (F&I) LF
4210-11 4'X4'X4' CONCRETE MANHOLE (F&I) EA
4210-12 4'X6.5'X6.5' CONCRETE MANHOLE (F&I) EA
LF CONDUCTORS (F&I) (INSULATED) #6 AWG
715-1-113
EA 678-1-111
REDUCTION ASSEMBLY
TRAFFIC CONTROLLER ACCESSORIES, F&I, POWER 1
1218 2 30 1402 219 657 2055 2118 1566 13 2 1 3 25 6919 315 338 472 2 1 1 2 1 1 1 1 1 1 2 1 1 1 7614 2600 124 14 2 22 5 7 455 491 1299 5 2 2 1 4 1 3 3 3 3 3 6 3 3 3 9298 3395 505 24 2 2 2 296 283 18758 3 1 2 2
664-3-140 TMS - POLE MOUNTED (30' POLE) (F&I) EA 2
1 844 52334
SR 429
429-203
PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 12:40:46 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\ITS_A03_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
GENERAL NOTES (1)
17. 16. 15. 14. 13. 12. 11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. GENERAL NOTES:
FO-5
30. 29. 28. 27. 26. 25. 24. 23. 22. 21. 20. 19. 18. 30.DURING ALL LANE CLOSURE OPERATIONS AND DURING ALL NIGHT OPERATIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A LAW ENFORCEMENT OFFICER E.
MANUAL SPECIFIED IN THE MUTCD
FOR ADDITIONAL SIGN INFORMATION, INCLUDING SIZES, REFER TO STANDARD HIGHWAY SIGNS D.
DURING ALL PHASES OF CONSTRUCTION.
LANE WIDTH SHALL NOT BE LESS THAN 11 FEET. LANES SHALL BE PROPERLY DELINEATED C.
SERIES.
TRAFFIC SHALL BE MAINTAINED IN ACCORDANCE WITH FDOT DESIGN STANDARDS, INDEX 600 B.
SHALL BE INCLUDED IN PAY ITEM 102-1 MAINTENANCE OF TRAFFIC (LUMP SUM)
OF CONSTRUCTION ACTIVITIES. ALL COSTS ASSOCIATED WITH THE MAINTENANCE OF TRAFFIC AUTHORITY, THE TRAFFIC CONTROL PLAN MUST BE IN PLACE PRIOR TO THE COMMENCEMENT PROFESSIONAL ENGINEER, REGISTERED IN THE STATE OF FLORIDA. ONCE APPROVED BY THE CONTRACTOR MUST PROVIDE A TRAFFIC CONTROL PLAN WHICH IS SGNED AND SEALED BY A WHICH CONSISTS OF UNMODIFIED FDOT DESIGN STANDARDS (600 SERIES); OTHERWISE THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN TO THE AUTHORITY FOR APPROVAL A.
MAINTENANCE OF TRAFFIC: ALLOTTED.
INFRASTRUCTURE NOT ON OOCEA FACILITIES. NO ADDITIONAL TIME OR MONEY WILL BE THE CONTRACTOR SHALL ACQUIRE ALL PERMITS BY OTHER AGENCIES FOR INSTALLATION OF NECESSARY.
THE CONTRACTOR SHALL AVOID AND/OR PROTECT ALL TREES AND ROOTS BY HAND DIGGING AS ALL SYMBOLS FOR ROADWAY LIGHTING ARE SHOWN FOR REFERENCE ONLY.
CONTRACTOR FOR LOCATION OF MANHOLE TIE-INS.
CONTRACTOR REGARDING LOCATIONS OF PULL BOXES AND COORDINATE WITH FIBER OPTIC THE CONTRACTOR SHALL REFERENCE SIGNING & MARKING PLANS AND COORDINATE WITH S&PM PLACED WITHIN EXISTING RIGHT-OF-WAY.
ACCOMMODATE LOCAL CONDITIONS AND EXISTING UTILITY LOCATIONS. CONDUIT SHALL BE CONTROLLER BOXES ARE DIAGRAMMATIC ONLY AND MAY BE SHIFTED BY THE ENGINEER TO THE LOCATION OF THE CONDUCTORS, CONDUITS, JUNCTION BOXES, SERVICE POINTS, AND ALL ELECTRICAL EQUIPMENT SHALL BE WEATHERPROOF.
FIBER SPLICING AND PORT ASSIGNMENTS.
INCLUDE A RECORD OF THE COLOR DESIGNATIONS OF ALL HDPE CONDUIT USED, AS WELL AS SERVICES, CONDUITS, STRUCTURES, AND FIELD COMPONENTS. THE AS-BUILT PLANS SHALL CONTAIN ACCURATELY DIMENSIONED LOCATIONS FOR FIBER OPTIC CABLE, PULL BOXES, POWER AS-BUILT PLANS WITH ALL CHANGES MARKED IN RED TO THE ENGINEER. THE AS-BUILTS SHALL UPON FINAL ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL FORWARD A COMPLETE SET OF THIS PLAN SET.
ALL OF THE GENERAL NOTES FOR THE CONTRACT CONSTRUCTION DOCUMENT SET WILL APPLY TO CONTRACTOR SHALL REVIEW SPECIFICATION 631 FOR OTHER FON PRESERVATION DETAILS. FIBER OPTIC NETWORK SHALL BE PERFORMED ON ONE SIDE OF THE ROAD AT A TIME. THE THE OOCEA FIBER OPTIC NETWORK. ANY CONSTRUCTION ACTIVITIES WITHIN TEN FEET OF THE CONSTRUCTION. AT NO TIME SHALL THERE BE ANY LOSS OF COMMUNICATIONS OR DATA ALONG THE CONTRACTOR SHALL MAINTAIN THE EXISTING FIBER OPTIC NETWORK WITHIN THE LIMITS OF OHMS OR LESS IS ACHIEVED AT NO ADDITIONAL COST TO THE AUTHORITY.
GROUND ELECTRODE OR A GROUND ARRAY SHALL BE INSTALLED UNTIL MEASURED RESISTANCE OF 5 OBTAINED WITH THE INITIAL 20 LINEAR FEET OF GROUNDING ELECTRODE, THEN ADDITIONAL OHMS OR LESS. ALL CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. IF 5 OHMS IS NOT 720 AND 721, WITH A MINIMUM LENGTH OF 20 LINEAR FEET AND A MEASURED RESISTANCE 5 DMS CABINET. INSTALLATION SHALL BE IN ACCORDANCE WITH OOCEA SPECIFICATIONS 620A, A GROUNDING ELECTRODE IS REQUIRED PER EACH POLE, DMS SIGN STRUCTURE, DMS BOX, AND ADDITIONAL PAYMENT WILL BE ALLOWED.
THE POLE LOCATIONS RE-ESTABLISHED BY A FLORIDA REGISTERED LAND SURVEYOR. NO AND/OR PAINTED MARKS ARE OBLITERATED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO HAVE FLORIDA REGISTERED LAND SURVEYOR. IF, DURING THE CONSTRUCTION PROCESS, THE STAKES THE CONTRACTOR SHALL ESTABLISH, STAKE AND PAINT POLE LOCATIONS WITH THE USE OF A
ISSUE.
TROUBLE TICKET. IF ALARMS REMAIN, ADVISE CEI IMMEDIATELY AND WORK TO RESOLVE THE ARE CLEAR. IF ALL ALARMS ARE CLEAR, ADVISE THE TECHNICIAN IT IS OK TO CLEAR THE COMPLETED. BE SURE TO ASK THE TECHNICIAN IF ALL ALARMS ASSOCIATED WITH THE TICKET NUMBER RECEIVED EARLIER AND ADVISE THE CENTURYLINK TECHNICIAN THAT WORK HAS BEEN ONCE WORK IS COMPLETE, CALL BACK IN AND REFERENCE THE REMEDY TROUBLE TICKET G.
ASK THE CENTURYLINK TECHNICIAN FOR A REMEDY TROUBLE TICKET NUMBER. F.
AND ENDING OF YOUR WORK.
ADVISE THE CENTURYLINK TECHNICIAN OF THE ESTIMATED TIME FRAME OF THE BEGINNING E.
HEADQUARTERS).
ANTICIPATE AN ALARM FOR IDENTIFY BY THE NEAREST MAINLINE PLAZA OR ON/OFF RAMP OR IDENTIFY THE AREA IN WHICH YOU ARE GOING TO BE WORKING AND WHICH SITES YOU D.
PROVIDE YOUR NAME AND CONTACT INFORMATION (INCLUDING PHONE NUMBER). C.
EXPRESSWAY AUTHORITY" (OOCEA).
IDENTIFY YOURSELF AS A CONTRACTOR WORKING FOR THE "ORLANDO ORANGE COUNTY B.
THEN OPTION 1, THEN OPTION 1.
CALL CENTURYLINK ANS TO OPEN A NEW TICKET. THE PHONE NUMBER IS 407-621-3802, A.
WORK PERFORMED IN ANY MANHOLE LOCATED ON THE FIBER OPTIC NETWORK (FON)-NO EXCEPTIONS. FON UTILITY WORK PROCEDURE: AN ANS TICKET MUST BE OPENED WITH CENTURYLINK FOR ALL
SPECIFICALLY EXEMPT IN THE PLANS. COST SHALL BE INCIDENTAL TO OTHER CONSTRUCTION. CONDITION EQUAL TO OR BETTER THAN EXISTING PRE-CONSTRUCTION CONDITION UNLESS AUTHORITY PROPERTY AFFECTED BY THE CONSTRUCTION WORK SHALL BE RESTORED TO A J.
PERFORMING ANY WORK WITHIN 2,000 FEET OF A TOLL PLAZA.
CONTRACTOR SHALL COORDINATE WITH TOLL PLAZA MANAGERS 72 HOURS PRIOR TO I.
THE CONTRACTOR'S OPERATIONS.
CONTRACTOR, I.E. CATASTROPHIC EVENTS, AND ACCIDENTS NOT NOT RELATED OR CAUSED BY TO OPEN TRAFFIC LANES/RAMPS IF SUCH CAUSE IS BEYOND THE CONTROL OF THE
CONSTRUCTION AND/OR HIS DESIGNEE, LANE RENTAL FEES WILL NOT BE CHARGED FOR FAILURE THE CONTRACTOR BY THE AUTHORITY. AT THE DISCRETION OF THE DIRECTOR OF
SHALL HAVE THE RIGHT TO APPLY AS PAYMENT ON SUCH FEES ANY MONEY THAT IS DUE TO LANE/RAMP IS OPEN TO A TRAFFIC FLOW AS RECORDED BY THE AUTHORITY. THE AUTHORITY LANE RENTAL FEES WILL BE ASSESSED AND WILL CONTINUE TO ACCRUE UNTIL SUBJECT H.
MINUTE THAT ANY LANE/RAMP IS NOT OPEN TO TRAFFIC.
ASSESSED TO THE CONTRACTOR IN THE AMOUNT OF $1,000 PER LANE/RAMP FOR EACH OCCUR OUTSIDE THE PERMITTED LANE CLOSURE HOURS, A LANE RENTAL FEE WILL BE AND TRAVEL LANES ARE REOPENED TO TRAFFIC. FOR MAINLINE AND RAMP CLOSURES THAT INSTALLED BY THE CONTRACTOR FOR LANE CLOSURES ARE REMOVED FROM THE CLEAR ZONE THE CONTRACTOR SHALL PLAN OPERATIONS SUCH THAT ALL EQUIPMENT AND MATERIALS OPEN TO TRAFFIC DURING THE TIMES OUTSIDE OF THE PERMITTED LANE CLOSURE HOURS. DELAY COSTS TO THE CONTRACTOR WILL RESULT IF ALL TRAVEL LANES AND RAMPS ARE NOT G.
TRAFFIC AND SHALL BE COMPLETELY COVERED SO AS NOT TO BE READABLE.
OPERATION, UNUSED MOT SIGNS MAY SIGNS MAY REMAIN IN PLACE, BUT SHALL NOT FACE THEIR USE FOR THE DESIGNED TRAFFIC CONTROL OPERATION. DURING RESTRICTED HOURS OF AND/OR WARNING DEVICES TO THE APPROPRIATE STORAGE FACILITY UPON COMPLETION OF IT IS THE CONTRACTOR'S RESPONSIBILITY TO REMOVE ALL UNUSED BARRICADES, SIGNS, F.
SHALL BE CONSIDERED INCIDENTAL TO THE COST OF THE POLE ASSEMBLY, PULL BOX, ETC. HAUL ALL EXCESS EXCAVATION AND WASTE MATERIALS OFF-SITE. REMOVAL OF THESE MATERIALS ASSEMBLY, PULL BOX, ETC. ALL DISTURBED AREAS SHALL BE SODDED. THE CONTRACTOR SHALL RESETTING) IS CONSIDERED INCIDENTAL, AND IS TO BE INCLUDED IN THE COST OF POLE BOXES, ETC. (I.E. GRADING, SODDING, CLEARING AND GRUBBING, GUARDRAIL OR FENCE ALL MISCELLANEOUS WORK NECESSARY IN THE SHOULDER AREA TO CONSTRUCT POLES, PULL CONTRACTOR.
ALL APPLICABLE PROVISIONS OF EXISTING UTILITY EASEMENTS WILL BE ADHERED TO BY THE N.E.S.C. FOR CABLE USED.
MANUFACTURES REQUIREMENTS. ALL BENDS SHALL NOT BE LESS THAN RECOMMENDED BY N.E.C. OR AND NOT TO JACKET AND MEET MANUFACTURERS REQUIREMENTS. USE PULLING COMPOUND PER PULLING INSTRUCTIONS FOR POWER CONDUCTORS: CONNECT PULLING DEVICES TO COPPER WIRE SHALL BE PROPERLY GROUNDED AND BONDED PER N.E.C. REQUIREMENTS.
D.O.T. STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. ALL COMPONENTS NATIONAL ELECTRICAL CODE, NATIONAL ELECTRIC SAFETY CODE, AND THE STATE OF FLORIDA ALL ELECTRICAL WORK SHALL MEET ALL REQUIREMENTS OF THE LATEST EDITIONS OF THE SAFEGUARD EXISTING UTILITIES DURING FIBER/EQUIPMENT INSTALLATIONS.
CONTRACTOR SHALL MAKE SURE THAT ALL NECESSARY PROTECTIVE MEASURES ARE TAKEN TO BACKFILLING AROUND POLE SHALL CONFORM TO SECTION 125 OF THE STANDARD SPECIFICATIONS. THE CONTRACTOR SHALL HAND DIG THE FIRST 4' AT EACH POLE INSTALLATION LOCATION. RESTORED TO ORIGINAL PRE-WORK CONDITIONS.
RESPECT TO MAINTAINING THE POWER FEED AND ROUNDING CIRCUITRY. ALL FEATURES SHALL BE SAFETY MEASURES WHEN WORKING IN OR AROUND THESE AREAS. CAUTION SHALL BE TAKEN IN FOR ALL OVERHEAD SIGN STRUCTURES, THE CONTRACTOR SHALL EXERCISE ALL APPROPRIATE ALL CONCRETE GUTTERS SHALL BE MAINTAINED OR RESTORED TO PRE-WORK CONDITIONS. THE WORK CORRIDOR SHALL BE RESTORED TO PRE-WORK CONDITIONS.
APPROXIMATE.
LOCATION OF ALL PROPOSED EQUIPMENT TO BE INSTALLED SHALL BE CONSIDERED TO BE ETC. ABOVE FIBER OPTIC CABLES (AT&T, MCI WORLD COM, OOCEA FIBER OPTIC ETC). THE VIBRATORY ROLLERS SHALL NOT BE ALLOWED FOR COMPACTION OPERATIONS OF PAVEMENT, SOILS, UNLESS APPROVED BY THE AUTHORITY. NO U-TURNS SHALL BE PERMITTED IN THE MEDIAN. PROJECT BY EXISTING RAMPS. NO ACCESS WILL BE ALLOWED THROUGH THE RIGHT-OF-WAY FENCE SITE OF WORK AT NO ADDITIONAL COST TO THE AUTHORITY. CONTRACTOR SHALL ACCESS THE AUTHORITY SYSTEM IN TRANSPORTING WORKERS, EQUIPMENT OR MATERIALS TO AND FROM THE THE CONTRACTOR IS RESPONSIBLE FOR PAYING OF ALL TOLLS INCURRED FROM USING THE OF SUNSHINE STATE ONE-CALL OF FLORIDA, INC.
BEGINNING ANY EXCAVATION OR DEMOLITION. NOT ALL UTILITY AGENCIES/OWNERS ARE MEMBERS INC., AT 1-800-432-4770, NOT LESS THAN 2 OR MORE THAN 5 BUSINESS DAYS BEFORE
FLORIDA STATUTE 556 REQUIRES CONTRACTORS TO CALL SUNSHINE STATE ONE-CALL OF FLORIDA, HAND DIGGING SHALL BE USED AROUND ALL KNOWN AND LOCATED UTILITIES.
AROUND AREAS OF OVERHEAD ELECTRICAL/TRANSMISSION LINES OR UNDERGROUND UTILITIES. THE CONTRACTOR SHALL EXERCISE ALL APPROPRIATE SAFETY MEASURES WHEN WORKING IN OR THE PROJECT AREA.
CONTRACTOR SHALL COORDINATE HIS ACTIVITIES WITH ALL OTHER CONTRACTORS OPERATING IN AT THE CONTRACTOR'S EXPENSE.
LANDSCAPE MATERIAL DAMAGED DURING THE CONSTRUCTION PROCESS SHALL BE REPLACED IN KIND CAUTION THROUGH LANDSCAPING LIMITS DURING ALL PHASES OF CONSTRUCTION ACTIVITY. ANY IN ORDER TO MINIMIZE IMPACT TO LANDSCAPING MATERIAL, THE CONTRACTOR SHALL EXERCISE ANY FURTHER WORK ACTIVITY.
IN THESE PLANS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY AND PRIOR TO PHYSICAL CONDITIONS PREVENT THE APPLICATION OR THE PROGRESSION OF ANY WORK SPECIFIED THESE PLANS REFLECT CONDITIONS KNOWN DURING PLAN DEVELOPMENT. IN THE EVENT ACTUAL PRIOR TO BEGINNING CONSTRUCTION.
THE CONTRACTOR SHALL NOTIFY THE ORLANDO-ORANGE COUNTY EXPRESSWAY AUTHORITY 48 HOURS
SR 429
429-203
PROJECT NO. ROAD NO.
USER: lyfe6246 4/11/2014 5:39:41 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\CADD\its\ITS_A01_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
GENERAL NOTES (2)
9. 8. 7. 6. 5. 4. 3. 2. 1. CONDUIT: 33. 32. 31.GENERAL NOTES (CONTINUED):
10. 11. 12. 13. 14. 15. PULL BOXES: 1. 2. 3. DMS: 1. 2. 3. 4. 5. 6.
FIBER OPTIC CABLE:
1. 2. 3. 4. TMS: 1. 2.
PAY ITEM NOTES:
1. 2. 3. 4. 5. 6. 7.
FO-6
CABLE OUTER TENSILE RATING SHALL BE USED ON ALL PULLS.
EYE DURING CABLE PULLING. "BASKET GRIP" OR "CHINESE FINGER" TYPE ATTACHMENTS TO THE CENTRAL STRENGTH MEMBER AND ARAMID YARN SHALL BE ATTACHED DIRECTLY TO THE PULLING CHARACTERISTICS OF THE CABLES ARE NOT DEGRADED AT THE TIME OF INSTALLATION. THE BY THE CABLE MANUFACTURER AND SHALL BE SUCH THAT THE OPTICAL AND MECHANICAL THE FIBER OPTIC CABLE INSTALLATION TECHNIQUES AND PROCEDURES SHALL BE AS SPECIFIED THE SIGNAL.
STRUCTURES, AND CONNECTED TO THE DMS BOX, SHALL BE 1-2" FOR THE POWER AND 1-2" FOR THE GALVANIZED RIGID STEEL CONDUITS TO BE LOCATED ON EACH OF THE OVERHEAD SIGN LOCATION OF DMS EQUIPMENT.
CONTRACTOR TO COORDINATE WITH LIGHTING AND SIGNING CONTRACTOR REGARDING FINAL THE FIBER OPTIC LOCATE WIRE IS NOT BE RUN INTO THE CABINET OR DMS HOUSING. TO THE EXISTING "AUX" CIRCUIT OUTLET AS SHOWN IN THE BLOCK DIAGRAMS.
CONTRACTOR SHALL POWER THE DCS EQUIPMENT FROM A CONTRACTOR FURNISHED UPS CONNECTED DCS EQUIPMENT IS NOT TO UTILIZE THE GFCI RECEPTACLE FOR POWERING EQUIPMENT. THE REGISTERED LAND SURVEYOR. NO ADDITIONAL PAYMENT WILL BE ALLOWED.
CONTRACTOR'S RESPONSIBILITY TO HAVE THE DMS LOCATIONS RE-ESTABLISHED BY A FLORIDA CONSTRUCTION PROCESS, THE STAKES AND/OR PAINTED MARKS ARE OBLITERATED, IT IS THE LOCATIONS WITH THE USE OF A FLORIDA REGISTERED LAND SURVEYOR. IF, DURING THE
MONUMENTS HAVE BEEN OBLITERATED THE CONTRACTOR SHALL ESTABLISH, STAKE AND PAINT DMS IN AREAS WHERE DIMENSIONS ARE NOT PROVIDED ON THE PLANS OR WHERE THE EXISTING LIGHTING AND OTHER OOCEA CONDUIT PRIOR TO INSTALLATION OF DMS STRUCTURE FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATIONS OF EXISTING ROADWAY ANY MANHOLE INSTALLED WITHIN PAVEMENT SHALL HAVE STUBOUTS.
OHMS OR LESS IS ACHIEVED.
ELECTRODE OR A GROUNDING ARRAY SHALL BE INSTALLED UNTIL MEASURED RESISTANCE OF 25 THE INITIAL 20 LINEAR FEET OF GROUNDING ELECTRODE, THEN ADDITIONAL GROUNDING A MEASURED RESISTANCE OF 25 OHMS OR LESS. IF 25 OHMS OR LESS IS NOT OBTAINED WITH ELECTRODE IN ACCORDANCE WITH FDOT STANDARD SPECIFICATIONS SECTION 620 AND SHALL MEET EACH FIBER OPTIC PULL BOX SHALL INCLUDE A MINIMUM OF 20 LINEAR FEET OF GROUNDING MAXIMUM PULL BOX SPACING FOR POWER SERVICE SUPPLY TO BE 500'.
PULL BOXES SHALL HAVE "OOCEA POWER" STAMPED ON THE COVER.
ALL FIBER OPTIC PULL BOXES SHALL HAVE "OOCEA" STAMPED ON THE COVER AND ALL POWER THE COST OF BRFG.
ALL HARDWARE AND BRACKETS ASSOCIATED WITH BRIDGE-MOUNTED BRFG SHALL BE INCIDENTAL TO PROJECT.
ROADWAY PLANS, DRAINAGE PLANS, STRUCTURE PLANS AND OTHER PLAN COMPONENTS OF THIS HORIZONTAL AND VERTICAL LOCATION AS SHOWN IN THE ROADWAY CROSS SECTIONS OF THE THE BACKBONE FIBER OPTIC CONDUIT NETWORK SHALL BE MAINTAINED AT A CONSTANT UNDERGROUND.
BORED FOR THE FIRST CONDUIT ONLY. SUBSEQUENT CONDUIT RUNS WILL BE PAID FOR AS MULTIPLE CONDUIT RUNS IN THE SAME TRENCH SHALL BE JACK AND BORED OR DIRECTIONAL TO VERIFY POSSIBLE UTILITY CONFLICT.
SECTION 2-4 OF THE FDOT SPECIFICATIONS. THE CONTRACTOR SHALL HAND DIG THE FIRST 4' EXAMINE JOB SITE CONDITIONS BEFORE SUBMITTING BID PROPOSALS IN ACCORDANCE WITH INSTALLED BY JACKING OR TRENCHING. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IT SHOULD BE NOTED THAT NO TEST BORINGS WERE MADE WHERE CONDUIT RUNS ARE TO BE SHALL NOT OPEN ANY AREA THAT CANNOT BE BACKFILLED IN THE SAME DAY/NIGHT OPERATION. END OF EACH WORKING DAY OR WHENEVER THE WORK ZONE BECOMES INACTIVE. THE CONTRACTOR ALL CONDUIT TRENCHES SHALL BE BACKFILLED COMPLETELY TO PROVIDE SAFE CROSSING BY THE DUST, DIRT OR MOISTURE.
ALL NEW UNDERGROUND CONDUIT SHALL BE SEALED AT BOTH ENDS TO PREVENT THE ENTRY OF
9. 8.
10. 4.
WILL NOT BE PERMITTED.
MANHOLES. SPLICING THE TONE WIRE FOR THE TMS, DCS OR DMS TO THE BACKBONE TONE WIRE FOR THE 9-1" BACKBONE FON CONDUIT SHALL BE SPLICED CONTINUOUS IN THE FIBER OPTIC COILED IN THE FIBER OPTIC PULL BOX OR CABINET AT THE DEVICE LOCATION. THE TONE WIRE TO THE GROUNDING SYSTEM IN THE FIBER OPTIC MANHOLE AND 2 FEET OF TONE WIRE SHALL BE THE TONE WIRE FOR THE TMS, DCS AND DMS FIBER OPTIC CONDUIT RUNS SHALL BE CONNECTED IN ACCORDANCE WITH N.E.C. IDENTIFY ALL CIRCUITS AND EQUIPMENT WITH "LAMICOID TAGS". DRAINAGE OR OTHER UTILITIES PER THESE PLANS.
MINIMUM REQUIRED CONDUIT BURY DEPTHS SHALL BE MAINTAINED WHERE CONFLICTS OCCUR WITH USE.
ALL EMPTY POWER CONDUITS SHALL BE CAPPED AND FURNISHED WITH A PULL STRING FOR FUTURE ALL HDPE CONDUIT CONNECTIONS SHALL BE JOINED WITH ELECTROFUSION COUPLE.
SLACK INSIDE FOMH BEFORE ENTERING THE EXISTING FIBER OPTIC BACKBONE.
REQUIRED FOR CONDUIT ENTRY INTO THE MANHOLES. LEAVE MINIMUM OF 100 FEET OF CABLE TO THE BLUE 1" CONDUITS LOCATED INSIDE THE 4" STUBOUT. A 4" DUCT ORGANIZER IS
THE BLUE HDPE CONDUIT ENTERING A PROPOSED FIBER OPTIC MANHOLE (FOMH) SHOULD CONNECT CONDUIT RUN SHALL NOT EXCEED 270° OF BENDS BETWEEN MANHOLES OR JUNCTION BOXES. FIBER ROUTE AND AT ANY TURNS IN THE CONDUIT RUN.
INDICATING F.O. CABLE BURIED BELOW SHALL BE INSTALLED AT EACH MANHOLE ALONG THE TAPE CONTINUOUSLY RUN IN THE TRENCH 18" BELOW GRADE. IN ADDITION, RAISED MARKERS ALL FIBER OPTIC CONDUIT SHALL HAVE AN "OOCEA FIBER OPTIC CABLE BURIED BELOW" WARNING HORIZONTAL AND VERTICAL LOCATION.
THE BACKBONE FIBER OPTIC CONDUIT NETWORK SHALL BE MAINTAINED AT A CONSTANT EXCEED 4000'.
NOT EXCEED 1500'. SPACING BETWEEN FOMH INSTALLED IN AN UNPAVED SHOULDER SHALL NOT THE SPACING BETWEEN FIBER OPTIC MANHOLES (FOMH) INSTALLED IN A PAVED SHOULDER SHALL FIBER OPTIC MANHOLE SPACING:
ONE ANOTHER FOR CLARITY ONLY.
CABINET EQUIPMENT IS NOT TO BE STACKED. THE WIRING DIAGRAMS SHOW BLOCKS ON TOP OF AUTHORITY.
OUTSIDE OF NORMAL BUSINESS HOURS (7AM-6PM MONDAY-FRIDAY) UNLESS APPROVED BY THE ALL WORK INVOLVING THE SPLICING OR TESTING OF LIVE FIBERS IS TO BE PERFORMED I.
CENTURYLINK SHALL VERIFY THAT ALL ROUTER ALARMS HAVE CLEARED.
INSTRUCTED IN THE FON UTILITY WORK PROCEDURE. IN ADDITION TO THIS PROCEDURE, AND CONTACT CENTURY LINK TO CLOSE TICKET AFTER THE WORK IS COMPLETE, AS CURRENTLY THE CONTRACTOR SHALL OPEN A TICKET WITH CENTURYLINK PRIOR TO BEGINNING ANY WORK, H.
OR "HOT CUTS", ARE TAKING PLACE.
AN AUTHORITY REPRESENTATIVE SHALL BE PRESENT ON-SITE WHEN SPLICING LIVE FIBER, G.
POSSESSION OF THE MOST RECENT PLAN UPDATES BEFORE BEGINNING ANY WORK. THE CONTRACTOR SHALL VERIFY WITH EITHER THE GEC OR THE CEI THAT THEY ARE IN F.
ESCALATION CONTACT BEFORE BEGINNING WORK.
A PRIMARY AND BACKUP EMERGENCY CONTACT SHALL BE PROVIDED AS WELL AS AN E.
PROPOSED SPLICING DATE.
A PRE-SPLICE MEETING SHALL BE HELD AT LEAST ONE (1) WEEK IN ADVANCE OF THE D.
PAY ITEMS.
TO BEGINNING WORK. PAYMENT FOR THIS WORK SHALL BE INCIDENTAL TO FIBER OPTIC SPLICING ADVANCE OF THE PRE-SPLICING MEETING. THIS MOP MUST BE REVIEWED AND APPROVED PRIOR SHALL PROVIDE A HIGH LEVEL OF METHOD OF PROCEDURE (MOP) AT LEAST ONE (1) WEEK IN FOR ALL WORK INVOLVING THE DISRUPTION OF LIVE NETWORK TRAFFIC, THE CONTRACTOR C.
BE DOCUMENTED IN WRITING.
INDICATED ON THE PLANS OR WITHOUT PRIOR APPROVAL. ANY PATCH PANEL CHANGES SHALL NO CONTRACTOR SHALL BE PERMITTED TO MOVE ANY PATCH PANEL CONNECTIONS UNLESS B.
PRIOR APPROVAL FROM THE AUTHORITY.
NO CONTRACTOR SHALL BE PERMITTED TO ENTER THE MAINLINE OR RAMP PLAZAS WITHOUT A.
FON UTILITY WORK GUIDELINES:
TRANSFORMERS ARE TO INCLUDE WINDING TAPS (4-2% 2+,2-)
APPROPRIATE LUGS FOR 120, 240 AND 480 SERVICES PER THE POWER SERVICE DETAILS. NO. 678-1-111. ALL TRANSFORMERS SHALL BE RATED FOR OUTDOOR USE AND HAVE THE TMS SENSORS SHALL BE MOUNTED PER MANUFACTURER'S USER GUIDE.
BE INCLUDED IN THIS ITEM, THIS INCLUDES THE 4' CANTILEVER ARM AS SHOWN IN THE PLANS. INSTALLATION. ALL REQUIRED EQUIPMENT NOT PAID FOR BY A SEPARATE PAY ITEM NO. SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLETING A FULL FUNCTIONAL PAY ITEM. THE WIRING DIAGRAMS ARE CONSIDERED THE MINIMUM REQUIRED EQUIPMENT AND DOES REQUIRED TO COMPLETE A FULLY FUNCTIONAL TMS INSTALLATION SHALL BE INCIDENTAL TO THIS NECESSARY TO COMPLETE A FULLY FUNCTIONAL TMS INSTALLATION. ANY NEMA ENCLOSURE 664-1-XXX SHALL INCLUDE ALL ADDITIONAL COMPONENTS, CABLING, AND ACCESSORIES BY A SEPARATE PAY ITEM NO. SHALL BE INCLUDED IN THIS ITEM.
OF COMPLETING A FULLY FUNCTIONAL INSTALLATION. ALL REQUIRED EQUIPMENT NOT PAID FOR MINIMUM REQUIRED EQUIPMENT AN DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLETE A FULLY FUNCTIONAL INSTALLATION. THE WIRING DIAGRAMS ARE CONSIDERED THE NO. 663-74-IXX. SHALL INCLUDE ALL ADDITIONAL COMPONENTS AND ACCESSORIES NECESSARY STANDARDS. THE PLATE SHALL BE RIVETED TO THE METER ENCLOSURE.
OUTSIDE FRONT BY A NON-FERROUS METAL OR PLASTIC PLATE PER DUKE ENERGY OR OUC 639-1-22. EACH POWER SERVICE METER ENCLOSURE SHALL BE CORRECTLY IDENTIFIED ON THE CONSIDERED INCIDENTAL TO THE COST OF THIS PAY ITEM.
FUNCTIONAL INSTALLATION (I.E. CIRCUIT BREAKERS, PHOTO CELLS, ETC.) SHALL BE
THE CONTRACTOR OF THE RESPONSIBILTY TO MEET ALL LOCAL REQUIREMENTS FOR A FULLY IN THESE PLANS SHOULD BE CONSIDERED THE MINIMUM REQUIREMENTS AND DOES NOT RELIEVE INSTALLATION PER THE LATEST OUC AND DUKE ENERGY STANDARDS. THE POWER SERVICE DETAILS THE REQUIRED DISCONNECTS AND OTHER COMPONENETS NECESSARY FOR AN ACCEPTABLE
NO. 639-X-XX . SHALL INCLUDE AND PAY FOR RESPONSIBILITY OF THE CONTRACTOR TO VERIFY CONDUIT BANK IS BURIED UNDER PAVEMENT.
SPECIFICATIONS. TONE WIRE SHALL BE ENCLOSED IN 1" HDPE CONDUIT ONLY WHEN FIBER OPTIC REQUIREMENTS OF HDPE CONDUIT CONTAINED IN SECTION 638 OF THE TECHNICAL
SHALL BE CONNECTED TO FIBER OPTIC MANHOLES ON BOTH ENDS AND SHALL MEET ALL MATERIAL INSTALLING AN ADDITIONAL 1" HDPE CONDUIT AS A DUCT FOR THE TONE WIRE. HDPE CONDUIT 638-461-0914 & NO. 4230-1. PAYMENT FOR THESE ITEMS SHALL INCLUDE FURNISHING AND NO. 638-001-0211, NO. 638-001-0911, NO. 638-260-0011, NO. 638-361-0911, NO.
REQUIREMENTS.
638-461-0914 & NO. 4230-1. SEE SECTION 638 OF THE TECHNICAL SPECIFICATIONS FOR NO. 638-001-0211, NO. 638-001-0911, NO. 638-260-0011, NO. 638-361-0911, NO.
SPECIFICATIONS FOR REQUIREMENTS.
NO. 635-1-11, NO. 635-1-15 AND NO. 635-1-16. SEE SECTION 635 OF THE TECHNICAL FOR REQUIREMENTS.
NO. 633-121-2 AND NO. 633-121-4. SEE SECTION 633 OF THE TECHNICAL SPECIFICATIONS NO. 603A-100. SEE SECTION 603A OF THE TECHNICAL SPECIFICATIONS FOR REQUIREMENTS CHANNELS TO AVOID INTERFERENCE.
WHEN MOUNTING MORE THAN ONE SENSOR PER LOCATION, ENSURE THAT THEY ARE ON DIFFERENT APPLICABLE).
SHALL INCLUDE ALL LANES IN THE DIRECTION, THROUGH LANES AND RAMP LANES (IF
EACH TMS SENSOR SHALL READ ONE DIRECTION OF TRAVEL AS INDICATED IN THE PLANS. THIS BOX AS FIBER OPTIC CABLE.
UNDER NO CIRCUMSTANCES SHALL ENERGIZED CABLE BE PLACED IN THE SAME CONDUIT OR PULL FIBERS AND ALL FIBER SPLICING.
CONTRACTOR SHALL COORDINATE WITH OOCEA REPRESENTATIVE PRIOR TO DISCONNECTING ANY MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY STANDARDS.
ALL FIBER OPTIC CABLE INSTALLATION PROCEDURES SHALL BE IN ACCORDANCE WITH THE
SR 429
429-203
PROJECT NO. ROAD NO.
USER: lyfe6246 4/11/2014 5:39:45 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\CADD\its\ITS_A02_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
GENERAL NOTES (3)
PAY ITEM NOTES (CONTINUED):
UTILITY NOTES: 1. 2. 3. 4. 2. 1.
FIBER CABLE AND CONNECTION DISTRIBUTION: 3. 2. 1. POWER CONNECTIONS:
FO-7
13. 14. 15. 16. 17. 18.FIBER CABLE IN BLUE CONDUIT FOR FEEDER CABLE - 2-1" BLUE AND ORANGE HDPE CONDUITS W/ 1-12 STRAND FEEDER DROP CABLE
FIBER CABLE IN BLUE CONDUIT FOR FEEDER TRUNK CABLE. ORANGE CONDUIT FOR BACKBONE TRUNK CABLE AND 72-STRAND - 9-1" HDPE CONDUITS WITH 72-STRAND FIBER CABLE IN BACKBONE CABLE
PAY ITEM NUMBER 639-1-12 AND 639-1-22.
EQUIPMENT AND LABOR TO BE SUPPLIED FOR A COMPLETE CONNECTION AND IS TO BE PAID UNDER EXISTING OR NEW BREAKER PANEL WITH THE APPROPRIATE CIRCUIT BREAKER. ALL MATERIALS, CONNECTING TO THE PROPOSED POWER SOURCE. CONNECTIONS MUST BE MADE THROUGH AN CONTRACTOR'S ELECTRICIAN TO PRE-EXAMINE EACH SITE TO DETERMINE THE FEASIBILITY OF CONNECTIONS TO EXISTING POWER METERS TO BE ACCOMPLISHED PER STATE AND LOCAL CODES. FINAL CONNECTION BY DUKE ENERGY PERSONNEL.
SERVICE WIRE COILED INSIDE. CONTACT DUKE ENERGY NEW CONSTRUCTION AT 866-372-4663 FOR THAT EXISTS OR CONTRACTOR INSTALLS AND SET A PULL BOX WITH APPROX. 10' OF ELECTRICAL DUKE ENERGY SERVICE: CONTRACTOR TO RUN UNDERGROUND CONDUIT TO THE BASE OF PEDESTAL THE EVENT A PROPOSED POWER SOURCE IS NOT READILY AVAILABLE.
POSSIBLE TO ENSURE ALL POWER SOURCES CAN BE INSTALLED AS SHOWN IN THE PLANS OR IN THAT THE CONTRACTOR CONTACT EACH RESPECTIVE POWER COMPANY CONTACT PERSON AS SOON AS POWER SUPPLY LOCATIONS HAVE BEEN COORDINATED WITH DUKE ENERGY. IT IS RECOMMENDED
AND STAKE UNDERGROUND UTILITIES PRIOR TO EXCAVATING.
CONTRACTOR SHALL STAKE ALL POLE LOCATIONS AND REQUEST UTILITY COMPANIES TO LOCATE BE APPROVED BY THE ENGINEER.
SHALL VERIFY DEPTH BY POT HOLING PRIOR TO SHOOTING THE BORE. ANY OTHER METHOD MUST BE INCLUDED IN THE COST OF THE CONDUIT. WHEN BORING UNDER PAVEMENT, THE CONTRACTOR AND HORIZONTALLY (VVH) FOR ALL CONDUIT INSTALLATIONS. THE COST FOR THE VVH'S SHALL THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING UNDERGROUND UTILITIES VERTICALLY OTHERS AS DIRECTED BY THE ENGINEER.
TO LOCATE AND STAKE THEIR UNDERGROUND FACILITIES. UTILITIES ARE TO BE ADJUSTED BY EXCAVATING THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANY OWNER(S) AND REQUEST THEM SHOWN AS NOTICE TO THE CONTRACTOR THAT UNDERGROUND UTILITIES EXIST. BEFORE BASED ON THE INFORMATION FURNISHED TO THE ENGINEER BY THE UTILITY OWNER(S) AND ARE THE LOCATION OF EXISTING UTILITIES, AS SHOWN ON THESE PLANS, ARE APPROXIMATE AND PRIMARY HIGH VOLTAGE COMPONENTS.
EXTREME CAUTION SHALL BE EXERCISED AT ALL TIMES IN PERFORMANCE OF WORK AROUND THE CONDUCTORS AT INSTALLATION SITE, OR TAKE OTHER SAFETY PRECAUTIONS AS NECESSARY. COMPANY, AT ITS OPTION, SHALL ASSIST THE OCOEE CONTRACTOR. COVER UP ENERGIZED INSTALLATION THAT IS WITHIN 10 FEET OF ENERGIZED ELECTRICAL CONDUCTORS. THE POWER THE CONTRACTOR SHALL NOTIFY THE POWER COMPANY AT LEAST 48 HOURS PRIOR TO ANY REQUIREMENTS. THE CONTRACTOR SHALL INCLUDE STUBOUTS IN ALL INSTALLED MANHOLES. NO. 4210-11 AND 4210-12. SEE SECTION 636 OF THE TECHNICAL SPECIFICATION FOR WORK.
PAD LOCATION ARE AT THE FINAL GRADE & COMPACTION PRIOR TO DUKE ENERGY DOING THEIR ALSO, THE CONTRACTOR IS RESPONSIBLE FOR MAKING SURE THE CABLE ROUTE AND TRANSFORMER OF 36 INCHES FOR THE 2" CONDUIT (WITH PULL STRINGS) FOR SECONDARY SERVICE FEEDER. TRANSFORMER AND METER. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A MINIMUM COVER CONNECTION OF THE ELECTRICAL SERVICE. DUKE ENERGY WILL PROVIDE THE PAD MOUNTED CONTINUOUS FOR THE ITS DEVICES. CONTRACTOR TO INCLUDE ALL FEES FOR INSPECTION OF NO. 17504. THIS LOAD CENTER SHALL NOT INCLUDE A PHOTOCELL SINCE THE POWER SHALL BE MISCELLANEOUS HARDWARE FOR A COMPLETE INSTALLATION AS PER PLANS AND STANDARD INDEX FROM POWER COMPANY POINT OF SERVICE TO DMS POWER SERVICE, PULL BOX AND OTHER PROTECTION ON THE OUTSIDE OF THE ENCLOSURE, BREAKERS, CONDUIT AND FEEDER CONDUCTORS METER BASE, SERVICE POLE INSULATORS, WEATHER HEADS, FUSES, PANEL BOARD, LIGHTNING NO. 715-7-11. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE CONCRETE SERVICE POLE, NO. 715-2-334. THE 1-2" RGS SURFACE MOUNTED CONDUIT WILL HAVE 4 RUNS PER DMS. ETC. TO ITS ORIGINAL CONDITION.
THE LINEAR FOOT PRICE FOR CONDUIT SHALL ALSO INCLUDE RESTORING CUT PAVEMENT, SOD, & AND BACK FILL AS INDICATED IN THE PLANS, SPECIFICATIONS, AND THE "DESIGN STANDARDS". NO. 715-2-115. SHALL INCLUDE CONDUIT ELBOWS; SWEEPS, CONNECTING HARDWARE, TRENCHING SHALL BE MADE BASED ON LINEAR FEET OF SINGLE CONDUCTOR.
IN THE PLANS, SPECIFICATIONS, AND THE "ROADWAY AND TRAFFIC DESIGN STANDARDS" PAYMENT NO. 715-1-114, NO. 715-1-115, NO. 715-1-116. SHALL INCLUDE CONDUCTORS AS INDICATED
TERMINAL SERVICE, FIBER OPTIC JUMPER CABLES AS NECESSARY.
SPECIFICATIONS, THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ETHERNET SWITCHES, AND 6' X 6' CONCRETE PAD (F & I) AS SHOWN HEREIN. PER SECTION 4.4 AND 4.5 OF THE DMS DEVICES INCLUDING TRANSIENT VOLTAGE SURGE SUPPRESSION, BREAKER PANELS, WIRING, AND A CONDUITS U-CHANNELS FOR MOUNTING ELECTRICAL EQUIPMENT, ELECTRICAL SUPPRESSION INCLUDE A POLE MOUNTED MAINTENANCE CABINET, STEP-DOWN TRANSFORMER, GALVANIZED PAY ITEM 700-89-13F, ELECTRICAL POWERED SIGN (CHANGEABLE - LED). THE PAY ITEM IS TO TO BE FURNISHED & INSTALLED AS DESCRIBED IN THE SPECIFICATIONS AND PAID FOR UNDER NO. 700-89-13F. THE DYNAMIC MESSAGE SIGN SYSTEMS (LED) (3 LINE) FOR THIS PROJECT ARE
SR 429
429-203
PROJECT NO. ROAD NO.
USER: lyfe6246 4/11/2014 5:39:48 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\CADD\its\ITS_A02a_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
6" BLACK STEEL PIPE (BSP) E/W 8-1" HDPE CONDUITS
1-6" BULLET RESISTIVE FIBERGLASS (BRFG)
CONDUIT ATTACHED TO BRIDGE E/W HDPE 8-1" CONDUITS
6" PVC, SCHEDULE 40 E/W 8-1" HDPE
6" SPLIT BLACK STEEL PIPE (BSP) E/W HDPE CONDUITS EXISTING FIBER OPTIC MANHOLE
EXISTING BLACK STEEL PIPE (BSP) PULL BOX (13"x24"x12"D)
FIBER OPTIC PULL BOX (17"x30"x12"D)
LEGEND
2-1" HDPE CONDUITS (FEEDER) EXISTING PULL BOX (13"x24"x12"D)
EXISTING FIBER OPTIC PULL BOX (17"x30"x12"D)
LOWERING SYSTEM ON STEEL POLE W/ FOUNDATION EXISTING POLE MOUNTED CABINET & CAMERA W/
LOWERING SYSTEM ON STEEL POLE W/ NEW FOUNDATION RELOCATED POLE MOUNTED CABINET & CAMERA W/
(OPENING 36", BASE 44"x24" DEEP) EXISTING FIBER OPTIC ROUND PULL BOX
(OPENING 36", BASE 44"x24" DEEP) PROPOSED FIBER OPTIC ROUND PULL BOX
FIBER OPTIC MANHOLE (4'x4'x4')
FIBER OPTIC MANHOLE (4'x6.5'x6.5') BOND WIRE CONNECTING ALL ITEMS.
SHEETS) AND INSULATED GREEN STRANDED CU AND GROUND WIRE SIZES SHOWN ON DETAIL INSULATED CONDUCTORS INSIDE (CONDUCTOR WITH AWG THWN STRANDED COPPER CIRCUIT 2" SCHEDULE 40 P.V.C UNDERGROUND CONDUIT PROPOSED UNDERGROUND SPARE POWER
WITH PULL STRING.
2" SCHEDULE 40 PVC UNDERGROUND CONDUIT PROPOSED UNDERGROUND SPARE CONDUIT
EXISTING CONCRETE PEDESTAL FOR POWER SERVICE. HDPE CONDUIT - SDR 11.
PROPOSED 2-1" FIBER OPTIC 1-4" SCHEDULE 40 PVC WITH
DIRECTION OF TRAVEL)
(# INDICATES NUMBER OF LANES READ, ARROW POINTS IN DATA COLLECTION SENSOR ANTENNA SITE
FIBER OPTIC MANHOLE WITH STUBOUT (4'x4'x4')
FIBER OPTIC MANHOLE WITH STUBOUT (4'x6.5'x6.5') PROPOSED POINT OF ELECTRICAL SERVICE
PAVEMENT MARKING PLAN SET. AS PART OF THE SIGNING AND SIGNING AND MARKING CONTRACTOR SIGN PANELS TO BE INSTALLED BY OVERHEAD SIGN TRUSS AND STATIC
PROPOSED TMS
BE PLACED OVER EACH LANE DETECTED) PROPOSED TMS DETECTION ZONES (SYMBOL SHOULD
GENERAL NOTES
AND LEGEND
9-1" HDPE CONDUITS (BACKBONE)EXISTING 9-1" HDPE CONDUITS
FO-8
X
HAVE DMS LOGO.
BOOKLET) PULL BOX COVER SHALL (SEE INDEX 17700 DESIGN STANDARDS PROPOSED PULL BOX
CABINET TO BE SIZED BY CONTRACTOR. ANCILLARY ELECTRICAL EQUIPMENT. POLE MOUNTED CABINET AND
FOR POWER SERVICE.
PROPOSED CONCRETE PEDESTAL
TMS = TRAFFIC MONITORING STATION SDR = SIZE DIMENSION RATIO E/W = EQUIPPED WITH
PVC = POLYVINYL CHLORIDE OUTER DUCT FOPB = FIBER OPTIC PULL BOX FOMH = FIBER OPTIC MANHOLE FO = FIBER OPTIC
DMS = DYNAMIC MESSAGE SIGN DCS = DATA COLLECTION SENSOR
COND. 2 = CONDITION 2 CROSSING (SEE FIBER OPTIC TRENCHING DETAILS) COND. 1 = CONDITION 1 CROSSING (SEE FIBER OPTIC TRENCHING DETAILS) BSP = BLACK STEEL PIPE POLYETHYLENE CONDUIT
BRFG = BULLET RESISTIVE FIBERGLASS OUTER DUCT ABBREVIATIONS
SR 429
429-203
PROJECT NO. ROAD NO.
USER: lyfe6246 4/11/2014 5:39:52 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\CADD\its\ITS_A04_V04.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
N
PROJECT LAYOUT
£ SB SR 429
£ NB SR 429
500Feet
0 100¡ CONST. SR 429 (WEKIVA PKWY)
STA. 212+81.09
¡ CONST. SR 429 (WEKIVA PKWY)
BEGIN PROJECT SECTION 429-203
END PROJECT SECTION 429-202
FO-11
FO-12
FO
-
1
3
FO
-
1
4
FO
-
15
FO
-
16
FO
-
17
FO
-
1
8
FO
-
1
9
FO-20
LEGEND
PROPOSED TMS SITE
PROPOSED DMS SITE
PROPOSED DCS SITE
DMS 36.1 DCS 36.1 DMS 36.1 DCS 36.1 TMS 36.1 TMS 36.1FO-9
10
20
30
210
220
2
3
0
24
0
25
0
2
6
0
270
280
320
3
3
0
34
0
35
0
3
6
0
3
7
0
380
1
2
0
1
3
0
1
4
0
15
0
1
6
0
170
180
2 2 PROJECT NO. ROAD NO.USER: MOZE6236 4/14/2014 5:45:48 PM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\playit01.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
PROJECT LAYOUT (2)
¡ CONST. SR 429 (WEKIVA PKWY)
¡ CONST. SR 429 (WEKIVA PKWY)
£ KELLY PARK RD
£ NB SR 429
£ SB SR 429
N
500Feet
0 100£ RAMP B
£ RAMP A
STA. 315+10.00
¡ CONST. SR 429 (WEKIVA PKWY)
BEGIN PROJECT SECTION 429-204A
END PROJECT SECTION 429-203
£ RAMP B-1
FO-21
FO-22
FO-23
FO-24
FO-25
FO-26
F
O
-2
7
FO-28
F
O
-2
9
LEGEND
PROPOSED TMS SITE
PROPOSED DMS SITE
PROPOSED DCS SITE
DCS 37.6 TMS 37.6FO-10
320
330
3
4
0
350
230
240
7
0
8
0
1
0
0
1
1
0
13
00
1
3
1
0
3
3
2
0
3
3
3
0
4
3
2
0
4
3
3
0
STA. 335+48.25 CONST. SR 429 (WEKIVA PKWY) 643BEGIN PROJECT SECTION 204A END CONSTRUCTION END PROJECT SECTION 203
STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 633-121-4 *638-001-0911 144 LF 3
280
290
300
310
3
4
0
350
230
240
7
0
9
0
1
0
0
1
1
0
380
13
00
180
5
2
9
0
5 30
0
5
3
1
0
23
00
23
10
PROJECT NO. ROAD NO. NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATEAndrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
SR 429 PLAN SHEET
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
1
4
+
2
0
.0
0
635-1-11 639-3-11 668-13 683-101 683-103 683-105 683-110 685-101 685-101A 685-103 700-89-13F 700-89-13F-SP 663-74-1423-#6 AWG WIRES (240 VAC) 1-2" PVC POWER CONDUIT W/
715-1-113 715-2-115
715-2-115 783-8-1
(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT 635-1-11 639-3-11 668-13 683-101 683-103 683-105 683-110 685-101 685-101A 685-103 700-89-13F 663-74-142 700-89-13F-SP
3-#6 AWG WIRES (480 VAC) 1-2" PVC POWER CONDUIT W/
715-1-113 715-2-115 STA 114+02, 64' LT
HUB CABINET
PROPOSED POLE MOUNTED
715-2-115 783-8-1
(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT
635-1-11 715-1-113 715-2-115 1 EA 1 EA 1 EA 1 EA 2 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 2 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 54 LF 18 LF 1 EA 1 EA 13 LF 65 LF 8 LF 8 LF 1 EA 1 EA 1 EA 1 EA 72 LF 18 LF 10 LF 10 LF 641-2-12 641-2-12 STA 114+02, 58' LT PROPOSED DMS & DCS MM 36.1
INSET 1 - PROPOSED DMS & DCS MM 36.1
STA 313+99, 61' RT PROPOSED DMS & DCS MM 36.1
INSET 2 - PROPOSED DMS & DCS MM 36.1
700-22-240
STA 314+00, 67' RT HUB CABINET PROPOSED POLE MOUNTED
EPB 429-36.1-SB 1 EA ITSPB 429-36.1-NB 635-1-11 EPB 429-36.1-NB ITSPB 429-36.1-SB
FO-11
1 EA 678-1-111 STA 314+11, 67' RT DISCONNECT & POLE ELECTRICAL SERVICE STEP DOWN TRANSFORMER 5-#6 AWG WIRES (480 VAC)1-2" PVC POWER CONDUIT W/
STA 214+20, 100' LT DISCONNECT & POLE ELECTRICAL SERVICE STEP DOWN TRANSFORMER
1 EA 678-1-111
311
312
313
314
111
112
1
1
3
1
1
4
208
209
210
211
212
213
214
2 2 L.A. R/W LINE 633-121-2 638-001-0211¡ CONST. SR 429 (WEKIVA PKWY)
635-1-11
L.A. R/W LINE
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 633-121-2 638-001-0211 631-100 631-101 633-121-4 633-141-3 633-141-4 631-100 631-101 633-121-4 633-141-4 £ SB SR 429 £ NB SR 429 633-121-2 638-001-0211 633-121-2 638-001-0211 (ORANGE CONDUIT)
SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND 638-001-0911
633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 715-1-113 715-2-115 715-1-113 715-2-115 SEE INSET 2 715-1-113 715-2-115 SERVICE ASSEMBLY
CONC. POLE W/ ELECTRICAL LOAD CENTER 'A'
635-1-11 639-1-22 641-2-12
635-1-15 635-1-15
UTILIZE ORANGE CONDUIT SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND
UTILIZE ORANGE CONDUIT SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND
UTILIZE ORANGE CONDUIT SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND
3-#6 AWG WIRES (480 VAC) 1-2" PVC POWER CONDUIT W/ SEE INSET 1 1 EA 1 EA 2 EA 13 LF 1 EA 135 LF 27 LF 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 109 LF 860 LF 172 LF 137 LF 139 LF 1 EA 1 EA 2 EA 11 LF 166 LF 498 LF 108 LF * * * * * * * * 638-001-0211 (ORANGE CONDUIT)
SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND 8 LF * 633-121-2 638-001-0211 (ORANGE CONDUIT)
SM FIBER CABLE FEEDER DROP 2-1" UG HDPE W/1-12 STRAND 9 LF * 633-121-2 633-121-2 * 633-121-2 * 635-1-15 1 EA 633-121-2 * 633-121-2 * 635-1-15 1 EA 633-121-2 * 146 EA 146 EA 9-1" HDPE CONDUITS EXISTING 6" BSP W/ 633-141-3
STA. 210+48.28, 32' RT.
¡ CONST. SR 429 (WEKIVA PKWY)
STA. 310+48.28=
BEGIN £ NB SR 429
STA. 210+48.28, 32' LT.
¡ CONST. SR 429 (WEKIVA PKWY)
PC STA. 110+48.28=
BEGIN £ SB SR 429
STA. 212+81.09
¡ CONST. SR 429 (WEKIVA PKWY)
BEGIN PROJECT SECTION 429-203
END PROJECT SECTION 429-202
STA 114+11, 125' LT EPB 429-36.1-SB EPB 429-36.1-SB 635-1-11 W/ 12 SM FOC SLACK FOPB 429-36.1-SB W/ 12 SM FOC SLACK FOPB 429-36.1-SB W/ 12 SM FOC SLACK FOPB 429-36.1-NB W/ 12 SM FOC SLACK FOPB 429-36.1-NB BY OTHERS SB 429 FOMH MM 36.1-NB BY OTHERS SB 429 FOMH MM 36.1-SB
5-#6 AWG WIRES (480 VAC) 1-2" PVC POWER CONDUIT W/
5-#6 AWG WIRES (480 VAC) 1-2" PVC POWER CONDUIT W/
PROJECT NO. ROAD NO.
USER: moze6236 5/28/2014 10:00:25 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit01.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
SR 429 PLAN SHEET
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
2
1
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
1
4
+
2
0
.0
0
664-1-140 664-3-140 715-2-115 783-8-1(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT
664-1-140 664-3-140
(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT
715-2-115 783-8-1 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 13 LF 13 LF 13 LF 13 LF
INSET 1 - PROPOSED TMS MM 36.1
} SB SR 429 STA 116+11, 55' LT NEMA CABINET W/ POLE MOUNTED PROPOSED TMS MM 36.1 } NB SR 429 STA 316+08, 55' RT NEMA CABINET W/ POLE MOUNTED PROPOSED TMS MM 36.1INSET 2 - PROPOSED TMS MM 36.1
635-1-11 635-1-11 ITSPB 429-36.1-NB ITSPB 429-36.1-SBFO-12
315
316
317
318
319
320
321
1
1
5
1
1
6
1
1
7
1
1
8
1
1
9
1
2
0
1
2
1
215
216
217
218
219
220
221
W O O D W O O D W O O D W O O D W O O D SEE INSET 1 SEE INSET 2¡ CONST. SR 429 (WEKIVA PKWY)
£ NB SR 429 £ SB SR 429 715-2-115 L.A. R/W LINE L.A. R/W LINE 783-8-1
(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT 715-2-115
783-8-1
(UTILIZE ORANGE CONDUIT) W/ TMS COMPOSITE CABLE
1-2" PVC COMPOSITE CABLE CONDUIT
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 168 LF 168 LF 682 LF 169 LF 169 LF 680 LF * * 638-260-0011 COND.2 6" BSP SPLIT 10 LF 638-260-0011 COND.2 6" BSP SPLIT 10 LF PROJECT NO. ROAD NO. NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
SR 429 PLAN SHEET
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
2
1
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
2
8
+
0
0
.0
0
FO-13
NOTES:
BRIDGES. SEE BRIDGE PLANS FOR FURTHER DETAIL.
CASING BETWEEN THE OUTSIDE TWO BEAMS OF EACH OF THE
CONTRACTOR SHALL INSTALL THE BRIDGE MOUNTED BRFG
1.
3
2
1
3
2
2
3
2
3
324
325
3
2
6
3
2
7
3
2
8
121
1
2
2
1
2
3
1
2
4
1
2
5
1
2
6
1
2
7
2
2
1
2
2
2
2
2
3
224
225
2
2
6
2
2
7
2
2
8
POND 203-1
4210-11 £ SB SR 429¡ CONST. SR 429 (WEKIVA PKWY)
L.A. R/W LINE L.A. R/W LINE
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
£ NB SR 429
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
633-121-4 STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" BRFG E/W 9-1"
638-461-0914 633-121-4
STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" PVC E/W 9-1"
638-361-0911
633-121-4 STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" PVC E/W 9-1"
638-361-0911 633-121-4
STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" PVC E/W 9-1"
638-361-0911
633-121-4 STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" BRFG E/W 9-1"
638-461-0914
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 4210-11 633-121-4 633-121-4 633-121-4 308 LF 1 EA 1 EA 1 EA 38 LF 340 LF 126 LF 39 LF 376 LF 39 LF 131 LF * * * * * * * * * * * 638-260-0011 COND.2 6" BSP SPLIT 10 LF 638-260-0011 COND.2 6" BSP SPLIT 10 LF 4210-11
STA 326+37.50
END BRIDGE NB
STA 124+50.00
BEGIN BRIDGE SB
STA 322+62.50
BEGIN BRIDGE NB
STA. 322+25, 40' RT } NB SR 429 FOMH MM 36.2-NB STA. 124+12, 40' LT } SB SR 429 FOMH MM 36.3-SB STA. 326+74, 40' RT } NB SR 429 FOMH MM 36.3-NB SEE NOTE 1 SEE NOTE 1 SEE NOTE 1 SEE NOTE 1 SEE NOTE 1 PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 10:00:48 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit03.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
SR 429 PLAN SHEET
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
2
8
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
3
5
+
0
0
.0
0
FO-14
3
2
8
3
2
9
3
3
0
331
332
3
3
3
3
3
4
3
3
5
1
2
8
1
2
9
1
3
0
1
3
1
132
133
134
2
2
8
2
2
9
2
3
0
231
232
2
3
3
2
3
4
2
3
5
FLOODPLAIN COMPENSATION
POND 203-2
¡ CONST. SR 429 (WEKIVA PKWY) £ SB SR 429
£ NB SR 429
L.A. R/W LINE
633-121-4 STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" BRFG E/W 9-1"
638-461-0914 633-121-4 STRAND SM FIBER CABLE HDPE CONDUIT W/2-72 6" PVC E/W 9-1"
638-361-0911
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 4210-11 633-121-4 1 EA 37 LF 111 LF 535 LF 709 LF * * * * * 638-260-0011 COND.2 6" BSP SPLIT 10 LF 638-260-0011 COND.2 6" BSP SPLIT 10 LF 638-260-0011 COND.2 6" BSP SPLIT 10 LF
STA 129+00.00
END BRIDGE SB
STA. 129+38, 40' LT } SB SR 429 FOMH MM 36.4-SB PROJECT NO. ROAD NO. NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATEAndrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
3
5
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
4
2
+
0
0
.0
0
SR 429 PLAN SHEET
FO-15
PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 10:01:10 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit05.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
3
3
6
337
338
339
3
4
0
3
4
1
3
4
2
1
3
5
1
3
6
1
3
7
1
3
8
1
3
9
1
4
0
1
4
1
2
3
5
2
3
6
237
238
2
3
9
2
4
0
2
4
1
2
4
2
W O O DPO
ND
2
0
3
-
2
£ NB SR 429 ¡CONST.SR 429(WEKIVAPKWY) L.A.R/W LINE £ SB SR 429 638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 4210-11 633-121-4 698 LF 595 LF 108 LF 1 EA * * * * 638-260-0011 COND.2 6" BSP SPLIT 10 LF 638-260-0011 COND.2 6" BSP SPLIT 10 LF STA. 341+00, 41' RT } NB SR 429 FOMH MM 36.6-NB
N
SR 429 PLAN SHEET
M
A
T
C
H
L
I
N
E
S
T
A
.
2
4
2
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
4
9
+
0
0
.0
0
50Feet
0 10FO-16
PROJECT NO. ROAD NO.USER: moze6236 5/28/2014 10:01:22 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit06.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
35
343
344
345
3
4
6
3
4
7
3
4
8
3
4
9
1
4
2
1
4
3
1
4
4
1
4
5
1
4
6
147
148
242
243
244
245
246
247
248
249
W O O D M ET A L M ET A LPO
ND
2
0
3
-
2
¡ CONST. SR 429 (WEKIVA PKWY) £ SB SR 429
£ NB SR 429 L.A. R/W LINE
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 638-001-0911
633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 4210-11 633-121-4 701 LF 701 LF 1 EA * * *
COMP POND
FLOODPLAIN
COMP POND
FLOODPLAIN
STA. 141+80, 41' LT } SB SR 429 FOMH MM 36.6-SB3
5
0
3
5
1
3
5
2
3
5
3
3
5
4
3
5
5
3
5
6
149
150
151
152
153
154
1
5
5
249
250
251
252
253
254
2
5
5
2
5
6
¡CONST.SR 429(WEKIVAPKWY) L.A.R/W LINE £ SB SR 429 £ NB SR 429 638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72
638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 4210-11 633-121-4 4210-11 633-121-4 671 LF 34 LF 586 LF 110 LF 1 EA 1 EA * * * * * * STA. 155+40, 41' LT } SB SR 429 FOMH MM 36.9-SB STA. 355+00, 41' RT } NB SR 429 FOMH MM 36.9-NB PROJECT NO. ROAD NO.
USER: moze6236 5/28/2014 10:01:33 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit07.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.
429-203
SR 429
N
50F
e
e
t
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
4
9
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
5
6
+
0
0
.0
0
SR 429 PLAN SHEET
FO-17
N
50Feet
0 10M
A
T
C
H
L
I
N
E
S
T
A
.
2
5
6
+
0
0
.0
0
M
A
T
C
H
L
I
N
E
S
T
A
.
2
6
3
+
0
0
.0
0
SR 429 PLAN SHEET
FO-18
356
357
358
359
3
6
0
3
6
1
3
6
2
3
6
3
1
5
6
1
5
7
158
159
1
6
0
1
6
1
1
6
2
2
5
6
2
5
7
2
5
8
259
260
2
6
1
2
6
2
2
6
3
PO
ND
2
0
3
-
4
¡CONST.SR 429(WEKIVAPKWY) L.A.R/W LINE L.A.R/W LINE £ SB SR 429 £ NB SR 429 638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72638-001-0911 633-121-4 STRAND SM FIBER CABLE 9-1" UG HDPE W/2-72 709 LF 684 LF * * 638-260-0011 COND.2 6" BSP SPLIT 10 LF PROJECT NO. ROAD NO.
USER: moze6236 5/28/2014 10:01:45 AM T:\PROJECTS\OOCEA\Wekiva_203_BSA\ITS\203'\planit08.dgn
NO. SHEET DESCRIPTION BY DATE REVISIONS DESCRIPTION BY DATE
Andrew J. Lucyshyn, P.E. No. 54624 Certificate of Authorization No. 24 482 S. Keller Road, Orlando, FL 32810
EXPRESSWAY AUTHORITY
ORLANDO-ORANGE COUNTY
ROAD NO. PROJECT NO.