• No results found

Power. When and where you need it.

N/A
N/A
Protected

Academic year: 2021

Share "Power. When and where you need it."

Copied!
7
0
0
Show more ( Page)

Full text

(1)
(2)

Power. When and where you need it.

Power Base is the only modular electrical system that

delivers seamless plug-and-play power from the closet to

the desktop. It’s also the only system backed by a solid

history of innovation and reliability.

After all, it was Haworth that pioneered the first modular

power solutions for use in systems furniture more than

30 years ago. Today, this industry-leading product line has

evolved into an integrated power delivery platform that

provides both three- and four-circuit solutions for every

workspace application, including freestanding and systems

furniture, moveable walls, access floors, and ceilings.

(3)

Zone Distribution Boxes provide the transition from a building’s electrical system to Power Base AI’s modular power distribution system. Available in three configurations — with one 8-wire port, two 8-wire ports, or three 8-wire ports — to easily accommodate a range of power densities.

Power Base Voice & Data Zone Distribution Box

Jumpers connect Zone Distribution Boxes, Service Modules, Splitters, and Infeeds for Haworth furniture and walls. Available in lengths from 5 to 50 feet, Jumpers provide plug-and-play connection between all of the system components.

Splitters are small connector blocks that connect up to four Jumpers and allow the branching of power anywhere in the system. Splitters also enable lean and agile layouts that keep first costs low while maintaining flexibility.

Service Modules provide in-floor power and voice/data access and are available in quad and dual receptacle configurations. All Power Base AI Service Modules offer Haworth’s patented snap-in receptacles, which allow quick change of circuit assignments and minimize the number of components in inventory.

Power Base AI

Part of the Power Base family of solutions, Power Base AI is designed specifically for architectural applications. Unlike other electrical systems rated for underfloor or ceiling use, Power Base AI uses just four components, making even large and complex applications easier to plan, install, and maintain. And every component is reusable, so there’s virtually no waste, and the system can be changed or expanded at any time.

Power Base Voice & Data

Power Base Voice & Data solutions include zone box housings and service outlets

compatible with all brands of premise cabling products, allowing Haworth to

integrate with any existing IT standard.

Haworth can also provide a Haworth cabling solution using the Power Base Voice

& Data Pre-Terminated Zone system, which offers a range of multi-port zone boxes

and pre-terminated, pre-tested cabling, as well as data closet components. It’s a

zone-based, plug-and-play cabling system that installs fast and reconfigures even

faster. Here are a few more Pre-Terminated Zone advantages:

• Arrives factory pre-tested and pre-terminated, limiting on-site labor and accelerating installation.

• Offers 100% reusability and virtually no waste. • Exceeds TIA/EIA and ISO standards.

1 2 3 4

(4)

Power Base

The original Power Base system is used in Haworth’s furniture and moveable walls. Power Base is an

unsurpassed solution when you need quick circuit access, flexibility, durability, ease of management,

and dedicated circuitry. Unlike other off-the-shelf systems, Power Base is designed

and manufactured by Haworth, for Haworth. That’s why, as part of Haworth’s overall commitment

to sustainability, Power Base is PVC free.

Flexible Connectors tie PDAs together. They are included with all powered panels. These plug-and-play connectors are keyed and color coded to distinguish the various circuit options and prevent wiring errors.

Receptacles with programmable circuit assignments are a Haworth innovation. They are designed for maximum flexibility, and they minimize the investment in spare parts inventory.

Infeeds can deliver power via a floor box, underfloor or ceiling system, or power tap in a wall or column. Haworth’s systems can be connected to building power through traditional fixed wire and conduit, but are most adaptable when connected through floor- or ceiling-based Power Base AI.

Power Distribution Assemblies (PDAs) are the heart of Power Base. Built into Haworth walls, panels, and tables, or quickly retrofitted in the field, these proven electrical components have a 25-year track record. And, all Haworth PDAs are non-handed for unrestricted component placement.

(5)

Choosing a 3- or 4-Circuit Design

Haworth’s Power Base is available in both 3- or 4-circuit

configurations, making it easier to adapt to specific user

needs and building electrical systems. To assure safety,

Power Base connectors are color coded, labeled, and

keyed to prevent connection between incompatible

circuit configurations.

It’s important to understand the advantages and

disadvantages of each circuit configuration before

choosing either 3-circuit or 4-circuit. The guide on the

facing page is meant to help you make an informed

decision based on your application.

3-Circuit/Separate Neutrals

This option provides 3 circuits, each with its own neutral.

Here’s what to consider:

• Aligns with the 3 phase national power grid and most North American buildings.

• Is compatible with the following building power configurations: › 3 phase (208Y/120V)

› Three wire single phase (120/240V) › Single phase (120V)

• Offers the most adaptability to special power needs such as: › multiple power sources

› facility energy control

› isolation of high harmonic loading

• Features receptacles with patented on-site circuit access programmability (available only on Power Base for furniture). • Offers receptacles in common ground or isolated

ground configurations.

4-Circuit/2+2

This option provides 4 circuits, two circuits share neutral #1, two

circuits share neutral #2. Here’s what to consider:

• Provides more circuits (4 vs. 3) for each homerun from the electrical closet, which can reduce the installed cost per circuit. • Is compatible with the following building power configurations:

› 3 phase (208Y/120V)

› Three wire single phase (120/240V)

• Is sometimes less adaptable to special power needs such as multiple power source or facility energy control.

› Special power needs are typically planned in sets of two circuits › In some cases, 10 gauge shared neutral may not fully isolate circuits

• Modular receptacles have fixed circuit access. • Offers receptacles in common ground or isolated

ground configurations.

4-Circuit/3+1

This option provides 4 circuits, three circuits share neutral #1, circuit

#4 has a separate neutral. Here’s what to consider:

• Provides more circuits (4 vs. 3) for each homerun from the electrical closet, which can reduce the installed cost per circuit.

• Is compatible with the following building power configurations: › 3 phase (208Y/120V)

• Is sometimes less adaptable to special power needs such as multiple power source or facility energy control.

› Special power needs are typically planned only using circuit #4 › In some cases, 10 gauge shared neutral may not fully isolate circuits

• Modular receptacles have fixed circuit access.

Hot 1 Neutral 1 Hot 2 Neutral 2 Hot 3 Neutral 3 Ground Isolated Ground Hot 1 Hot 2 Neutral 1 Ground Isolated Ground Hot 3 Hot 4 Neutral 2 Hot 1 Hot 2 Hot 3 Neutral 1 Ground Isolated Ground Hot 4 Neutral 2

(6)

Haworth and Power Base Make It Easy

Haworth and Haworth dealers provide layout and planning services for Power Base products. As part of the planning

process, we work with you to determine the combination of Power Base components that deliver the most function

per dollar. And if the solution includes Power Base AI, we provide a “future-proof,” zone-based layout flexible enough

to adapt to any space plan. We also make sure the electrical plan is aligned with the voice/data plan to avoid any

interference issues.

Haworth Power Base Advantages

• More sustainable—The Power Base system’s inherent reconfigurability maximizes lifecycle and minimizes waste. • Universal application—All Power Base products are

available in 3-circuit/separate neutral (3-3-2) or 4-circuit/ shared neutral (2+2, 3+1) configurations.

• Oversized shared neutral—On all Power Base 4-circuit systems, a 10 gauge shared neutral provides protection from high currents due to non-linear loads.

• Foolproof connection—All Power Base connectors are color coded and polarity keyed to prevent connection of electrically incompatible components.

• Flexible circuit assignment—Power Base for furniture offers Haworth’s exclusive programmable receptacles on 3-circuit systems and patented snap-in receptacles on 4-circuit systems for quick, easy change of circuit assignments. Power Base AI floor-mounted Service Modules also offer snap-in receptacles, offering an advantage over competitive systems in which circuit assignments can only be changed by replacing the entire floor module.

• Easier to expand and reconfigure—Unlike competitive systems, every Power Base cable and connector contains all eight wires, allowing for easy reconfiguration or expansion at any point in the system.

• Ready to install—Power Base components arrive pre-wired and pre-tested. No field wiring required, except for connection to building wiring.

• Furniture/architectural integration—Power Base for furniture seamlessly connects with Power Base AI in the floor or ceiling.

• Large capacity in a streamlined package—The Power Base AI 3-port Zone Distribution Box is only 11” x 11” x 21/8”, but can deliver 4800 VA in a 4-circuit configuration or 3600 VA in a 3-circuit configuration.

• Floor Modules built for heavy traffic—Power Base AI low profile and standard height Service Modules are equipped with steel covers that can withstand a 1000 lb point load and significantly exceed UL strength

• Built-in daisy chain capability—Power Base AI Service Modules include multiple modular connectors, allowing power to pass through and be routed to subsequent Service Modules.

• Underfloor air compatible—Power Base AI components are UL 183 listed for use in “air handling spaces other than plenums” per NEC Article 604. Such spaces include air handling spaces under access floors and above dropped ceilings.

• Connects to non-Haworth systems—While Power Base AI offers the most value when used with Haworth furniture and wall systems, Haworth offers Jumpers that allow field-wired transitions to non-Haworth systems.

In addition, the detailed layout drawing helps to minimize construction schedules and reduce costs by ensuring

that installation contractors know exactly what to do when they arrive on site. When the project is finished, the

Haworth plan becomes an “as built” drawing for your facilities team that shows how all components are laid out and

interconnected.

(7)

For more information call 800.344.2600 or 616.393.3000. Download additional copies at haworth.com.

This brochure is printed on FSC certified U2®:XG™, manufactured with electricity in the form of renewable energy (wind, hydro, biogas) and contains a minimum of 30% post-consumer recovered fiber. FSC is the global benchmark for responsible forest management.

Haworth is a registered trademark of Haworth, Inc.

References

Related documents

WinReporter ® offers a set of 58 predefined reports that will help the network administrator in his audit and monitoring tasks: hardware upgrades, software

Similarly, inequality solutions are required to determine the monotonicity and concavity of functions by the use of derivative (Sandor 1997).. E-mail address:

If you do not wish to use the EasyMed simplified application process, or cannot because your case does not qualify, then obtain the current state-specific life insurance

For example, if an agreement between the new commercial enterprise and the immigrant investor states that the investor can receive some portion of the capital investment

Composing a TOSCA Service Template for a “SugarCRM” Application using Vnomic’s Service Designer, www.vnomic.com. The SugarCRM application include

• Latvian companies are generally (65%) optimistic about business prospects in the single market, and the share of pessimists ( 10%) is slightly below average; a majority

To enable entering a parking space of a certain width from a lane of a certain width, the necessary space for turning curves of cars, the column grid of the garage, and the angle

Philips visibility solutions do more than reveal how your patients are doing now, they help prepare your care team and your organization for an evolving era of clinical mobility

Rated as “the strongest Employment Law team in West Wales” by the Legal 500, our specialist team of qualified solicitors works tirelessly for local businesses:.. • Sorting

Orienteering Australia does have a major role in the management of national teams and squads at junior and elite level, and in coordinating the National Orienteering League, which

• DC Grounded metallic parts for impulse suppression. Start-up operation of the RCU 86010149 is possible in an RET system supporting AISG 1.1 or supporting 3GPP/AISG 2.0

The MEP must provide the registry manager with the required metering information for each metering installation the MEP is responsible for, and update the registry metering records

The research began with the examination of the prevalent and  persisting issue of sexual harassment within college campus communities, and how to present  college students with

Khutsong and the Merafong Region are linked with the mining history of Gauteng, thus the area is able to provide for the current study a look at the lived experience and impact

A Time Zone is assigned to inputs, outputs, or access levels to determine when an input shall automatically arm/disarm, when an output shall automatically open/secure, or when

Significantly desirable economic heterosis across the environments was found in 44 crosses for days to 75% flowering, 9 crosses for number of ear bearing tillers, 30 crosses for

[r]

Take to the road with peace of mind knowing you have the best protection available – the motorcycle insurance program from Aviva Elite. Be it cruisers or touring, you can count

MyKochfertiliser.com.au is a simple and secure way to do business online – making it easy for you to do such things.. as manage your contracts, track your orders and keep on top of

• Automatic Voltage Regulation or AVR allows each generator to produce clean power.. The AVR is an electronic regulation system which stabilizes the voltage output from

The research also shows that when people are required to choose the total cost of the loan - rather than the monthly repayment amount - the repayment period they request is an

Available in 3 simplex (triplex) and 4 simplex (quad) single circuit and multi-circuit configurations, link multiple units together from one power infeed, in no particular