EM

(2)

DORMA EM

Hold-open magnets

DORMA’s new range of EM hold-open magnets provides the perfect complement to a technically and aesthetically advanced range of fire and smoke door products. These new market-orientated developments are character-ised by their ease of fixing

and functional elegance. And thanks to comprehen-sive quality assurance, they also offer maximum reliability and service life.

Certified to ISO 9001

Data and features 500 G 500 U 500 A

A modular system for

fire and smoke doors

Setting new standards

for hold-open magnets

... for the trade

2 Cost-effective modular

system offering the advantages of maximum flexibility with minimal stocking levels.

2 A further component in

the DORMA range for single-source supply.

... for the installer

2 Quick and easy to fix.

2 Sophisticated accessories

suitable for a wide range of applications.

... for the specifier/ architect

2 Uniform appearance

common to all models.

2 Modular system for

applica tion flexibility.

... for the user

2 Unobtrusive.

2 Concealed cable run.

2 Optimum holding force

with minimum power consumption. Plus points ... Fixing Surface-mounted 2 – 2 Flush-mounted – 2 – Floor-mounted1) 2 2 Holding force 400 N 2 2 2 Anti-remanence pin 2 2 2 Test pushbutton – – 2

Polarity reversal protection 2 2 2

Operating voltage 24 V AC/DC 2 2 2

Power consumption in W 1.5

On-load factor in % 100 (rated for continuous service)

Class of protection IP 402) Ambient temperature in °C 0 – 50 Weight in kg 0.41 0.42 0.46 Dimensions Width 85 85 85 in mm Length 85 85 85 Depth 32 35 35

Hold-open devices tested

to EN 1155 2 2 2

-mark for building

products 2 2 2

2 yes – no

1) Floor angle bracket required (accessory)

2) EM 500 A in conjunction with floor angle bracket:

Class of protection IP 43

DORMA MAG DORMA MAW DORMA MAT

DORMA EM 500 G DORMA EM 500 U DORMA EM 500 A

81 Ø 47 7 5 7 5 20 Ø 50 39 Ø 4,5 35 Ø 42 10 32 Ø 42 10 66 85 66 85 60 44 44 55 55 Ø 47 7 5 Ø 4,5 60 ° 60° 52 Ø 42 35 10 20 Hold-open magnets Armature plates Buffer zone

(3)

Electro-magnets of the series DORMA EM 500 for 24v AC/DC are tested and third-party verified by the Verband der Sachversicherer (VdS) e.V., Cologne (Association of Property Insurers), and have been approved by the German Institute for Building Techno logy (DIBt), Berlin,

for use in combination with the DORMA RMZ smoke detector

and other reputable smoke detector systems, (e.g. with DORMA RMZ: approval certificate No. Z-6.5-1890). In Germany, inspection and approval of the holdo-pen system is additionally required.

F

Approval certification The statutory regulations which apply in many coun-tries allow fire and smoke doors to be held open for a limited period of time by electro-magnetic hold-open devices which, in the event of a fire, are de-energised to release the door so as to enable auto matic closing. Such systems consist of a hold-open device, fire/smoke detection and alarm system,

power supply and release device, and generally have to be approved by an accredited institute or building authority (in Germany: the German Institute for Building Technology, Berlin). Electro-magnets are devices which hold open fire and smoke doors.

In the event of a fire, the hold-open magnet is

de-energised by the release device responding to a signal from the fire detector. The automatic closing action is provided by door closers which, in Germany, must correspond to DIN EN 1154 and be third-party verified. It must also be possible to manually release the hold-open device. According to the guidelines for hold-open systems applicable to

Germany, a manual release pushbutton is necessary when employing electro-magnets in such applicati-ons. The pushbutton employed must be red, carry the wording “Close door”, be located in the immediate vicinity of the door, and must not be hidden when the door is in its hold-open position. HT EM RMZ 230 V AC ±10 % MAG RM RM MAG MAG HT EM EM 230 V AC ±1 0% G-SR-EMR EM = Electro-magnet

HT = Manual release pushbutton

MAG = Armature plate

RM = Smoke detector (ceiling-mounted)

RMZ = Smoke detector (lintel-mounted)

(4)

DORMA EM

Modular system

overview

52 33 55 84 65 87 113 94 116 MAG MAW MAT EM 500 G EM 500 U EM 500 A Specification text EM 500 G

Hold-open magnet with pole reversal protection for wall or floor mounting*

Holding force 400 N 24v AC/DC

Generally approved by DIBt-Berlin for use in hold-open systems.

(System acceptance inspec-tion may be necessary.) Requisite accessories: Armature plate

Make: DORMA EM 500 G

EM 500 U

Hold-open magnet with pole reversal protection for flush fixing

Holding force 400 N 24v AC/DC

Generally approved by DIBt-Berlin for use in hold-open systems.

(System acceptance inspec-tion may be necessary.) Requisite accessories: Armature plate

Make: DORMA EM 500 U

EM 500 A

Hold-open magnet with pole reversal protection and integral test pushbutton, for wall or floor mounting* Holding force 400 N 24v AC/DC

Generally approved by DIBt-Berlin for use in hold-open systems.

(System acceptance inspec-tion may be necessary.) Requisite accessories: Armature plate

Make: DORMA EM 500 A

(5)

DORMA EM

Accessories

64 26 29 37 44 108 84 22 85 85 UP AP 82 82

Floor angle bracket

74 68 39 36 66 35 35 32 32 32 35 EM 500 A EM 500 G

For installation of hold-open magnets EM 500 G and EM 500 A as floor-mounted units.

A DORMA EM 500 B hold-open magnet for floor mounting comprises an EM 500 G or EM 500 A hold-open magnet and an

associated floor angle bracket. Specification text: see Page 4 Adapter frame 54 61 EM 500 G EM 500 A

The frame can be combined with the individual hold-open magnets of the series EM 500 G/U/A.

Separate manual release switch

HT - UP HT - AP

18 51

For releasing the hold-open device by hand.

When employing electro-mag nets in hold-open systems for fire and smoke doors, a manual switch may have to be provided in accordance with local or

national regulations (e.g. the guidelines of the German Institute for Building Technology (DIBt), Berlin, for German applications).

Close

door

(6)

92,5 54,5 70 55 6 ø 4,5 ø 50 175 / 325 / 475 125 / 275 / 425 150 / 300 / 450 18 5 5 ø 55 ø 4,5 55 44 55 44

DORMA EM

Hold-open magnets

Special models EM 500 H for floor, ceiling and wall mounting, with integral test pushbutton

EM + RMZ + 2xRM

Specification text:

24v DC hold-open magnet with pole reversal protection and integral test pushbutton for floor, ceiling and wall mounting.

Holding force 490 N. Generally approved by the DIBt-Berlin for use in hold-open systems (in Germany). (System acceptance inspec-tion may be necessary.)

Size: Y 150/175 mm Y 300/325 mm Y 450/475 mm Requisite accessories: Armature plate Make: DORMA EM 500 H HT 121 kΩ RMZ N PE L 230 V AC B 10 A EM 18 kΩ 18 kΩ 2 x 121 kΩ 2 x 121 kΩ RM RM Recommended cabling: I - (St) Y 2 x 2 x 0.6 RS-AM (Optional)

(7)

Note:

A hold-open magnet for floor mount ing comprises an electro-magnet of the type EM 500 G or EM 500 A and the floor angle bracket.

y = Hold open magnet separate

X = Armature plate separate

#

= Accessory

Colour XX

white 11

stainless steel finish 12

Separate manual release switch

HT-AP

35901532

HT-UP

35901531

MAG MAW MAT MAG I Floor Adapter

angle frame bracket xx X 69020110 xX 69020111 xX 69020112 xX 69021113 69011540 690xx541 EM 500 G X X X 24 V AC/DC y 690xx511 y y y

#

#

EM 500 U X X X 24 V AC/DC y 690xx521 y y y

#

EM 500 A X X X 24 V AC/DC y 690xx531 y y y

#

#

EM 500 H 150/175 mm X 24 V DC y 69015005 y

300/325 mm X y 69015006 y

X y 69015007 y

(8)

WN 050 917 51532, 07/09, RTS 85, F, x. XX. xx/09 ·

Sous réserve de modifications techniques

40 21226 29067 5 Door Control Automatic Glass fittings and Accessories Security Time and Access (STA)

Movable Walls

www.dorma.com

Door Control Division worldwide Central Europe DORMA GmbH + Co. KG DORMA Platz 1 D-58256 Ennepetal Phone +49 2333 793-0 Fax +49 2333 793-495 Australasia

DORMA Door Controls Pty. Ltd. 52, Abbott Road Hallam/Victoria 3803 Australia Phone +61 3 8795 0666 Fax +61 3 8795 0280 China/Hong Kong DORMA Door Controls (Suzhou) Co. Ltd. No. 9, Hong Feng Road Suzhou Singapore Industrial Park Suzhou, 215021

P.R. of China

Phone +86 512 67612481

Fax +86 512 67614582

DORMA Door Controls Pte. Ltd. Room 701, Technology Plaza 651 King’s Road North Point Hong Kong Phone +852 25034632 Fax +852 28875370 Emerging Markets DORMA GmbH + Co. KG DORMA Platz 1 D-58256 Ennepetal Phone +49 2333 793-0 Fax +49 2333 793-495

DORMA Door Controls (Pty.) Ltd. Kings Court 4A Mineral Crescent ZA-2000 Crown/Gauteng South Africa Phone +27 11 8300280 Fax +27 11 8300291 Far East

DORMA Far East Pte. Ltd. No. 31 Gul Lane Singapore 629425 Phone +65 6268 7633

Fax +65 6265 7995

France

DORMA France S.A.S. Zone Europarc Immeuble Mega 42 42, Rue Eugène Dupuis F-94046 Créteil Cedex Phone +33 1 41942400

Fax +33 1 41942401

Gulf

DORMA Gulf Door Controls FZE Jebel Ali Free Zone South Plot No. S 20135 Road No. SW 301 G P.O. Box 17268

Dubai – United Arab Emirates Phone +971 4 8020400

Fax +971 4 8869100 / 8869101

North America

DORMA Architectural Hardware DORMA Drive, Drawer AC Reamstown, PA 17567-0411 Phone +1 800 5238483

Fax +1 800 2749724

Scanbalt

DORMA Danmark A/S Sindalvej 6–8 DK-2610 Rødovre Phone +45 44 543000

Fax +45 44 543001

South America

DORMA Sistemas de Controles para Portas Ltda.

Av. Piracema, 1400 Centro Empresarial Tambore CEP 06400-933 Barueri/ São Paulo, Brasil Phone +55 11 46899280 Fax +55 11 46899215 South-East Europe DORMA AUSTRIA GmbH Pebering Strass 22 A-5301 Eugendorf Phone +43 6225 284880 Fax +43 6225 28491 South Europe DORMA Italiana S.r.l. Via. Canova 44/46 I-20035 Lissone (MI) Phone +39 039 244031

Fax +39 039 24403310

DORMA Ibérica, S.A. Camino San Martin de la Vega, 4 E-28500 Arganda del Rey (Madrid) Phone +34 91 8757850 Fax +34 91 8757881 UK/Ireland DORMA UK Ltd. Wilbury Way Hitchin GB-Hertfordshire SG4 0AB Great Britain Phone +44 1462 477600 Fax +44 1462 477601

DORMA • Türtechnik • International • Stand 16.06.2010

40 2122 6 31398 5 WN 0 51 364 51532, 07/10, EM, GB, x. DD. xx/10 ·

References

Related documents

For fire-protection systems related to doors in fire-rated walls and partitions and to doors in smoke partitions, comply with requirements in Division 8 Section

The extract was found to have median lethal dose (LD50) of 3807.89 mg/kg body weight orally and the aqueous methanol leaves extract at doses 250 and 1000 mg/kg produced

Most affected by financial crisis was the year of 2009, when it is notice a decrease of gross premium written in all regions, with an exception in case of Asia, where in the

Elective courses eligible for inclusion in this certificate program include courses related to Developmental Disabilities or to systems that service individuals with DD and their

Release normally open fire doors Release normally open fire doors Public Address system announcements Public Address system announcements Others as required Others as required AC

their intrinsic characteristics, hPSCs have been envisioned as an optimal cell source for the generation of complex tissue structures like the organ parenchyma and the vascular

Without state elections in 2020 and in a year when COVID-19 health restrictions cancelled many fundraising events, public contractors so far have disclosed their fewest

UNION CHECK VALVE BALL VALVE GATE VALVE UNION GAUGE UNION CHECK VALVE TO SIZE TANK PROPERLY – MATCH DRAWDOWN OF TANK TO CAPACITY OF PUMP. FUSE BOX OR SWITCH MAIN